Difference between revisions of "Approved Materials - Traffic Signals"

From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation Jump to search
Line 2,506: Line 2,506:


== Mounting Brackets ==
== Mounting Brackets ==
=== Radar Detector Mounting Bracket ===
 
=== Mast Arm Signal Head Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,516: Line 2,517:
|-
|-
|
|
|[https://www.pelcoinc.com/ Pelco Inc.]
|[https://www.pelcoinc.com/ Pelco]
|[[media:TRF PQL TS CAT Pelco RadarDetectorMountingBracket.pdf|SP-5987-TT-LL-SS-PXX]]
|[[media:TRF PQL TS CAT Pelco VehicleHeadMastArmSignalBracket.pdf|AG-0125-1-LL-SS-PXX (1-Section)<br>AG-0125-3-LL-SS-PXX (3-Section)<br>AG-0125-4-LL-SS-PXX (4-Section)]]<br><br>[[media:TRF PQL TS CAT Pelco HAWKSignalMastArmBracket.pdf|AG-0168-LL-SS-PXX (HAWK)]]
|[[media:TRF PQL PS MEM Pelco RadarDetectorMountingBracket.pdf|8/6/19]]
|[[media:TRF PQL TS MEM Pelco VehicleHeadMastArmSignalBracket.pdf|4/19/19]]<br><br><br><br><br><br><br>[[media:TRF PQL TS MEM Pelco HAWKSignalMastArmBracket.pdf|4/19/19]]
|[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket Hinge.JPG|Open Hinge View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket TopView.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket SideView.JPG|Side View]]
|[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket Hinge.JPG|Open Hinge View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket TopView.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket SideView.JPG|Side View]]
|-
|-
|A Division<br>of Olson<br>Aluminum<br>Castings
|A Division<br>of Olson<br>Aluminum<br>Castings
|[http://www.skybracket.com/ Sky Bracket]
|[http://www.skybracket.com/ Sky Bracket]
|[[media:TRF PQL TS CAT SkyBracket RadarDetectorMountingBracket.pdf|Bracket: SS-SBLL-RCM-XX]]<br>[[media:TRF PQL TS CAT SkyBracket RadarDetectorMountingAdaptor.pdf|Burle Style Adapter Plate: SB-PLT]]  
|[[media:TRF PQL TS CAT SkyBracket SignalHeadMountingBracket.pdf|SS-SBLL-18 (1-Section)<br>SS-SBLL-46 (3-Section)<br>SS-SBLL-60 (4-Section)]]<br><br>[[media:TRF PQL TS CAT SkyBracket HAWKMastArmBracket.pdf|SS-SBLL_HPB-18 (HAWK)]]
|[[media:TRF PQL TS MEM SkyBracket RadarDetectorMountingBracket.pdf|1/11/19]]
|[[media:TRF PQL TS MEM SkyBracket MastArmMountingBracket.pdf|1/11/19]]<br><br><br><br>[[media:TRF PQL TS MEM SkyBracket HAWKMastArmBracket.pdf|1/11/19]]
|Showing previously approved cable mounting system.<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketBack.JPG|Back View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket End.JPG|Mounting End]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket TubeCrossSection.JPG|Tube Section]]
|Shown with previously approved cable mounting system.<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketBack.JPG|Back View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket LowerArmTube.JPG|Lower Arm]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket Upper ArmTube.JPG|Upper Arm]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket TubeCrossSection.JPG|Tube Section]]
|-
|}
{{PQLNote|Stainless steel banding/cable and hardware<br><u>For Pelco:</u><br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>62" – for mast arm diameters ranging from 2” to 7”<br>84" – for mast arm diameters ranging from 7.1” to 10.5”<br>96" – for mast arm diameters ranging from 10.6” to 12.4”<br>110" – for mast arm diameters ranging from 12.5” to 14.6”<br>120" – for mast arm diameters ranging from 14.7” to 16.2”<br>132" – for mast arm diameters ranging from 16.3” to 18.2”<br>Color (XX) shall be as follows:<br>NC - No Color<br>33 - Glossy Black<br>71 - RAL6012 Green<br>39 - RAL8019 Dark Bronze<br><u>For Sky Bracket:</u><br>Required band length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>29” – for mast arm diameters ranging from 2” to 7”<br>42” – for mast arm diameters ranging from 8” to 11”<br>59” – for mast arm diameters ranging from 12” to 17”<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}
 
=== Mini Pre-empt Detector Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|
|[http://www.wavetronix.com/en Wavetronix]
|[https://www.pelcoinc.com/ Pelco Products, Inc.]
|[[media:TRF PQL TS CAT Wavetronixr RadarDetectorMountingBracket.pdf|WX-SS-611]]
|[[media:TRF PQL TS CAT Pelco EVPDetectorMountingBracket.pdf|Astro Brac AB-0155-L-SS-PNC]]
|[[media:TRF PQL TS MEM Wavetronixr RadarDetectorMountingBracket.pdf|4/29/16]]
|[[media:TRF PQL TS MEM Pelco EVPDetectorMountingBracket.pdf|1/11/19]]
|[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Connection.JPG|Connection Segments]]
|
|}
|}
{{PQLNote|Stainless steel banding/cable and hardware<br><u>For Pelco:</u><br>Tube Length (TT) to be determined per plans<br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>62" – for mast arm diameters ranging from 2” to 7”<br>84" – for mast arm diameters ranging from 7.1” to 10.5”<br>96" – for mast arm diameters ranging from 10.6” to 12.4”<br>110" – for mast arm diameters ranging from 12.5” to 14.6”<br>120" – for mast arm diameters ranging from 14.7” to 16.2”<br>132" – for mast arm diameters ranging from 16.3” to 18.2”<br>Color (XX) shall be as follows:<br>NC - No Color<br>33 - Glossy Black<br>71 - RAL6012 Green<br>39 - RAL8019 Dark Bronze<br><u>For SkyBracket:</u><br>Required banding length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>29” – for mast arm diameters ranging from 2” to 7”<br>42” – for mast arm diameters ranging from 8” to 11”<br>59” – for mast arm diameters ranging from 12” to 17”<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}
{{PQLNote|Stainless Steel banding mount<br>L &#x003D; Banding Length (29” or 42”)<br>PNC &#x003D; Process No Color}}


=== Mast Arm Signal Head Bracket ===
=== Radar Detector Mounting Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,545: Line 2,558:
|-
|-
|
|
|[https://www.pelcoinc.com/ Pelco]
|[https://www.pelcoinc.com/ Pelco Inc.]
|[[media:TRF PQL TS CAT Pelco VehicleHeadMastArmSignalBracket.pdf|AG-0125-1-LL-SS-PXX (1-Section)<br>AG-0125-3-LL-SS-PXX (3-Section)<br>AG-0125-4-LL-SS-PXX (4-Section)]]<br><br>[[media:TRF PQL TS CAT Pelco HAWKSignalMastArmBracket.pdf|AG-0168-LL-SS-PXX (HAWK)]]
|[[media:TRF PQL TS CAT Pelco RadarDetectorMountingBracket.pdf|SP-5987-TT-LL-SS-PXX]]
|[[media:TRF PQL TS MEM Pelco VehicleHeadMastArmSignalBracket.pdf|4/19/19]]<br><br><br><br><br><br><br>[[media:TRF PQL TS MEM Pelco HAWKSignalMastArmBracket.pdf|4/19/19]]
|[[media:TRF PQL PS MEM Pelco RadarDetectorMountingBracket.pdf|8/6/19]]
|[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket Hinge.JPG|Open Hinge View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket TopView.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket SideView.JPG|Side View]]
|[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket Hinge.JPG|Open Hinge View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket TopView.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Pelco MastArmMountingBracket SideView.JPG|Side View]]
|-
|-
|A Division<br>of Olson<br>Aluminum<br>Castings
|A Division<br>of Olson<br>Aluminum<br>Castings
|[http://www.skybracket.com/ Sky Bracket]
|[http://www.skybracket.com/ Sky Bracket]
|[[media:TRF PQL TS CAT SkyBracket SignalHeadMountingBracket.pdf|SS-SBLL-18 (1-Section)<br>SS-SBLL-46 (3-Section)<br>SS-SBLL-60 (4-Section)]]<br><br>[[media:TRF PQL TS CAT SkyBracket HAWKMastArmBracket.pdf|SS-SBLL_HPB-18 (HAWK)]]
|[[media:TRF PQL TS CAT SkyBracket RadarDetectorMountingBracket.pdf|Bracket: SS-SBLL-RCM-XX]]<br>[[media:TRF PQL TS CAT SkyBracket RadarDetectorMountingAdaptor.pdf|Burle Style Adapter Plate: SB-PLT]]  
|[[media:TRF PQL TS MEM SkyBracket MastArmMountingBracket.pdf|1/11/19]]<br><br><br><br>[[media:TRF PQL TS MEM SkyBracket HAWKMastArmBracket.pdf|1/11/19]]
|[[media:TRF PQL TS MEM SkyBracket RadarDetectorMountingBracket.pdf|1/11/19]]
|Shown with previously approved cable mounting system.<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketBack.JPG|Back View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket LowerArmTube.JPG|Lower Arm]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket Upper ArmTube.JPG|Upper Arm]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket TubeCrossSection.JPG|Tube Section]]
|Showing previously approved cable mounting system.<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketBack.JPG|Back View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket End.JPG|Mounting End]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket TubeCrossSection.JPG|Tube Section]]
|-
|-
|
|[http://www.wavetronix.com/en Wavetronix]
|[[media:TRF PQL TS CAT Wavetronixr RadarDetectorMountingBracket.pdf|WX-SS-611]]
|[[media:TRF PQL TS MEM Wavetronixr RadarDetectorMountingBracket.pdf|4/29/16]]
|[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Connection.JPG|Connection Segments]]
|}
|}
{{PQLNote|Stainless steel banding/cable and hardware<br><u>For Pelco:</u><br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>62" – for mast arm diameters ranging from 2” to 7”<br>84" – for mast arm diameters ranging from 7.1” to 10.5”<br>96" – for mast arm diameters ranging from 10.6” to 12.4”<br>110" – for mast arm diameters ranging from 12.5” to 14.6”<br>120" – for mast arm diameters ranging from 14.7” to 16.2”<br>132" – for mast arm diameters ranging from 16.3” to 18.2”<br>Color (XX) shall be as follows:<br>NC - No Color<br>33 - Glossy Black<br>71 - RAL6012 Green<br>39 - RAL8019 Dark Bronze<br><u>For Sky Bracket:</u><br>Required band length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>29” – for mast arm diameters ranging from 2” to 7”<br>42” – for mast arm diameters ranging from 8” to 11”<br>59” – for mast arm diameters ranging from 12” to 17”<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}
{{PQLNote|Stainless steel banding/cable and hardware<br><u>For Pelco:</u><br>Tube Length (TT) to be determined per plans<br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>62" – for mast arm diameters ranging from 2” to 7”<br>84" – for mast arm diameters ranging from 7.1” to 10.5”<br>96" – for mast arm diameters ranging from 10.6” to 12.4”<br>110" – for mast arm diameters ranging from 12.5” to 14.6”<br>120" – for mast arm diameters ranging from 14.7” to 16.2”<br>132" – for mast arm diameters ranging from 16.3” to 18.2”<br>Color (XX) shall be as follows:<br>NC - No Color<br>33 - Glossy Black<br>71 - RAL6012 Green<br>39 - RAL8019 Dark Bronze<br><u>For SkyBracket:</u><br>Required banding length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>29” – for mast arm diameters ranging from 2” to 7”<br>42” – for mast arm diameters ranging from 8” to 11”<br>59” – for mast arm diameters ranging from 12” to 17”<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}


=== Side Mount Signal Head and Pedestrian Signal Head Bracket ===
=== Side Mount Signal Head and Pedestrian Signal Head Bracket ===
Line 2,588: Line 2,606:
{{PQLNote|Yellow polycarbonate<br>X&#x003D;Y for Yellow<br>X&#x003D; B for Black}}
{{PQLNote|Yellow polycarbonate<br>X&#x003D;Y for Yellow<br>X&#x003D; B for Black}}


=== Mini Pre-empt Detector Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|
|[https://www.pelcoinc.com/ Pelco Products, Inc.]
|[[media:TRF PQL TS CAT Pelco EVPDetectorMountingBracket.pdf|Astro Brac AB-0155-L-SS-PNC]]
|[[media:TRF PQL TS MEM Pelco EVPDetectorMountingBracket.pdf|1/11/19]]
|
|}
{{PQLNote|Stainless Steel banding mount<br>L &#x003D; Banding Length (29” or 42”)<br>PNC &#x003D; Process No Color}}
{{PQLReturn}}
{{PQLReturn}}



Revision as of 09:40, 13 November 2019

Return to Approved Materials
Side arrow 80x66.png

Contractor Submittal Forms

GeekNotesIcon.png Note: This document is provided as a benefit to contractors and suppliers who are bidding projects for the City of Overland Park. Only products identified on this list will be approved for installation on City construction projects. This list shall not be used as a substitute for catalog cuts or material approval. All material approvals shall be submitted on the approved City of Overland Park Contract Project Submittal form. The form is available at City Hall by contacting Bruce Wacker at (913) 895-6027. Failure to comply will be cause for rejection of materials until proper submittals are received. This list is updated periodically. The contractor or supplier shall contact the City of Overland Park to make sure that they have the most current list prior to bidding a project. Failure to do so shall not constitute a legitimate claim for change orders. Before accessing any links, the City recommends that the user delete browsing history to insure the latest catalog cut information is displayed correctly.


Anchor Bolts

Anchor Bolts For Signal Mast Arm Poles

Notes Manufacturer Catalog Number Approval Date Photos
JH Botts Anchor Bolt Detail
1 1/2" x 54" x 6":
6 UNC 2A x 10" (54" + 6") GALV 20"
1 3/4" x 84" x 6":
5 UNC 2A x 10" (84" + 6") GALV 20"
2" x 84" x 6":
4 1/2 UNC 2A x 10" (84" + 6") GALV 20"
1/21/15
Millerbernd Use Column for "Part No. Bolt w/2 Nuts & 2 Flat Washers"
1 1/2" x 54" x 6": 460A579-12DNFW
1 3/4" x 84" x 6": 460A579-4DNFW
2" x 84" x 6": 460A579-5DNFW
7/30/15
Madden Bolt Corp fabricates for Union Metal Union Metal 1 1/2" x 54" x 6": 311657
1 3/4" x 84" x 6": 311658
2" x 84" x 6": 311659
7/5/16
Comment:
ASTM F1554 GR55
Threads shall be rolled

Anchor Bolts For Pedestal Signal Poles

Notes Manufacturer Catalog Number Approval Date Photos
Component Products, Inc Anchor Bolts: CPI-AB-18 4/24/14
Gades Sales Anchor Bolts: PB-5518-GLV 4/24/14
Pelco Products, Inc. Anchor Bolts: PB-5518-GLV 4/23/14
Comment:
ASTM A36, Gr 50
Threads shall be rolled
18" Length

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Backplates (Vehicular)

Standard Vehicular Backplates

Notes Manufacturer Catalog Number Approval Date Photos
Gades Sales / Neodesha Plastics BP481PO – 1 section
BP483PO – 3 section
BP484PO – 4 section
BP485PO – 5 section
5/5/03
Mid American Signal For Econolite Signal Heads
MI-1003-L2 – 3 section
For McCain Signal Heads
MI-1003-N – 3 section
5/5/03
Mobotrex / Eagle For Mobotrex / Eagle Signal Heads
BPD501ANFXX0N0-00 – 1 section
BPD503ANFXX0N0-00 – 3 section
BPD504ANFXX0N0-00 – 4 section
Where XX = 02 for AstroBracket and 05 for SkyBracket
BPD503TNF050N0-00 – HAWK
3/25/19
Pelco Products, Inc. For Econolite Signal Heads
BK-1001-L3 – 1 section
BK-1003-L3 – 3 section
BK-1004-L3 – 4 section
BK-1005-L3 – 5 section

BK-2032-L3 - HAWK

For McCain Signal Heads
BK-1001-N – 1 section
BK-1003-N – 3 section
BK-1004-N – 4 section
BK-1005-N – 5 section

BK-2032-N - HAWK
5/5/03
Comment:
0.125” thick
12” Signal Head Sections

Flexible Vehicular Backplates

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use Only Pelco Products Inc. Universal AeroFlex Options
Standard
BK-8000-3-PNC - 3 Section
BK-8000-4-PNC - 4 Section
With Fluorescent Border
BK-8000-3-RT2-PNC - 3 Section
BK-8000-4-RT2-PNC - 4 Section


Eagle DuraSig-Specific Poly AeroFlex Options
Standard
BK-8100-3-EagleSG-PNC - 3 Section
BK-8100-4-EagleSG-PNC - 4 Section
With Fluorescent Border
BK-8100-3-EagleSG-RT2-PNC - 3 Section
BK-8100-4-EagleSG-RT2-PNC - 4 Section


McCain Specific Poly AeroFlex Options
Standard
BK-8100-3-McCain-PNC - 3 Section
BK-8100-4-McCain-PNC - 4 Section
With Fluorescent Border
BK-8100-3-McCain-RT2-PNC - 3 Section
BK-8100-4-McCain-RT2-PNC - 4 Section

8/2/19 Front View
Back View
Connection
Comment:
Universal backplates will fit McCain 12" Poly, Econolite 12" Poly, TCT/Peek 12" Poly

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Cable

CNG Monitoring Cable/Illuminated Street Name Sign Cable

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 8103/3C14B7119-1 5/5/03
Falcon Fine Wire 980314X19-1-00 4/24/08
Comment:
1-3c#14 IMSA 19-1

CNG Power Cable 1-3c #2AWG

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 302
UL File # E197262
5/20/16 Cable
Label
E File No.
Coleman Cable Inc. 41112 MTW Cable 11/5/12 Cable
Southwire #2 AWG stranded copper
Service Wire Co XLP-USE-2-STR-BLK
Comment:
600 Volt Copper soft drawn stranded copper #2 AWG

Electrical Service Cable

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Diital Cable 304
UL file # E197262
5/20/16 Mfg Label
AWG Label
Cable
Alan Wire 04USE11 – 500’
UL file #E319493
1/30/12 Cable
E-File
Label
Member of The Marmon Group of Companies Cerro Wire & Cable Co, Inc. 1201-4401-Black
1201-4402 - White
1201-1105 - Green

UL file # E11098
5/5/03
Draka Cableteq Product Number 388932 7/8/09
Encore Wire LTD UL file # E174428 8/1/03 Cable
E-File
Kris Tech Wire Co, Inc. 0407-RHW/USE-BK
UL file # E207249
11/24/03 Cable
Label
Service Wire Co USEVW4BK
UL file # E105667
5/7/02 Cable
Label
Southwire Co 113472 – Black
476565 – White
952663 - Green

UL file # E32071
5/5/03
Comment:
No. 4 AWG USE Copper
Single cable, not three cables twisted on the reel

Emergency Vehicle Pre-emption (EVP) Detector Cable

Notes Manufacturer Catalog Number Approval Date Photos
Belden 580461 11/7/05 Cable
Global Traffic Technologies Model 138 3/24/08 Cable

Induction Loop Cable 1c#14

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 8450 6/29/09
Belden 580206 6/17/03
Supplier Clifford of Vermont 1C14B19LOOP 5/5/03
Falcon Fine Wire 14-1 IMSA 51-5 4/20/01
James Monroe Wire and Cable Corporation IMSA 51-5 9/1/99
Kris-Tech 1419-THHN-TUBE-PVC-BLACK 2/1/01
Comment:
IMSA Type 51-5 Tube Loop Detector Cable
PVC/nylon Insulated cable
PVC Tube
600 Volt


Multi-conductor 7c#14 and 2c#14

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable / Clifford of Vermont 7c – 8107 / 7C14B7I19-1
2c – 8102 / 2C14B7I19-1
5/5/03 2 Condctor Cable
7 Conductor Cable
Mylar Wrap
Label
Belden 7c – 601205
2c – 601457
2/1/01
Coleman Cable Inc. 7c – 559107
2c - 559102
1/10/12
Falcon Fine Wire 7c – 980714X19-1-00
2c – 980214X19-1-00
5/23/05
James Monroe Wire and Cable Corporation 7c – IMSA 19-1
2c – IMSA 19-1
9/1/99
Comment:
IMSA 19-1
600 Volt
Stranded Copper
#14 AWG


Micro loop Home Run

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies bought out 3M Global Traffic Technologies Model Canoga 30003 5/20/03

Non-Invasive Micro Loop Home Run Cable

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies bought out 3M Global Traffic Technologies Model Canoga 30003 2/18/08

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Radar Detector Home Run Cable

Notes Manufacturer Catalog Number Approval Date Photos
Allied Wire & Cable 091102WGP12 1/10/11
Falcon Fine Wire 532P2218HD-08
2 pair 22 AWG communication wires
1 pair 18 AWG power wires
11/13/14 Separated Cable
Bundled Cable
"Matrix Advance" Label
Label showing wire guage
Orion Wire / Wavetronix WX-SS-H705 1/10/11
Comment:
2 pair 22 AWG communication wires (blue, blue/white, orange, orange/white)
1 pair 20 AWG power wires (red and black)
1 drain cable, unless otherwise shown


Radar Detector Harness Cable

Notes Manufacturer Catalog Number Approval Date Photos
Orion Wire / Wavetronix WX-SS-H704-100 1/10/11
Comment:
100’ harness to be spliced to home run cable at pole base
Cable harness to be supplied with the detector.


Shielded Detector Lead-in 2c#14

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 8780 6/29/09 Cable
Belden 601765 2/1/01 Cable
This is actually a Belden Cable Clifford of Vermont 1P14T19I50-2 5/5/03
Falcon Fine Wire 98021450-2 5/5/06 Cable
General Cable C2550 5/5/03
James Monroe Wire and Cable Corporation JM43465 9/1/99
Comment:
IMSA Type 50-2 Loop Lead-in Cable
Polyethylene Insulated
600 Volt
Stranded Copper
#14 AWG

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

#10 AWG System Ground Wire and Tracer Wire

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable Green - 410GN
Red - 410RD

UL File # E208489
5/20/16 Ground Cable
Mfg Label
AWG Label
Tracer Cable
Cerowire Wire & Cable Co., Inc. Red – 112-3803
Green – 112-3805
UL file # E15119
5/5/03
Encore Wire LTD UL file # E123774 8/1/03
Purchased by Southwire Co. Essex Group, Inc. Product Number 070101
UL File # E14656
2/1/01
Senator / Southwire 22-97-57
UL file # E23919
5/5/03
Service Wire UL file # E105667 5/7/02
Comment:
Stranded copper #10 AWG THHN/THWN-2
600 volt
Tracer wire shall have Red insulation
Ground wire shall have Green insulation

#6 AWG Equipment Ground Wire

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable BC06S 5/20/16 Bare Copper Cable
Cerro Wire & Cable Co, Inc. Product Number
050-2200 or 050-2215
5/5/03
Encore Wire LTD Bare No. 6 AWG 8/1/03
Southwire Bare No. 6 AWG 5/5/03
Service Wire Co BSOS6 5/5/03
Comment:
Bare copper soft drawn solid copper #6 AWG


Video Detection Cable

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Exclusive Falcon Fine Wire 970316TS-00-1MP 1/30/12 Cable
Jacket
Econolite Exclusive Isotec X339313-00 (for Econolite Solo Terra Systems) 4/25/08 Cable
Comment:
16 AWG/3c

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Conduit and Fittings

HDPE Signal Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Dura-Line 1” – HDP100RSDR013SWBLKWHTNEMPT
1 ½” – HDP150RSDR013SWBLKWHTNEMPT
2” – HDP200RSDR013SWBLKWHTNEMPT
3” – HDP300RSDR013SWBLKWHTNEMPT
4” – HDP400RSDR013SWBLKWHTNEMPT
1/09/17
Comment:
Include "City Traffic" in the product line code
SDR 13.5 Black with 3 longitudinal white stripes
Smooth wall
UV Stabilized

HDPE Service Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Dura-Line 2” – 2SDR135BLK/RED
3” – 3SDR135BLK/RED
3/8/13
Comment:
SDR 13.5 Black with three longitudinal red stripes
Smooth wall
UV Stabilized

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

HDPE Couplings

Notes Manufacturer Catalog Number Approval Date Photos
American Polywater Bonduit Conduit Adhesive
Use with standard Sch 40 PVC Couplings
10/11/10 Cartridge
Equipment
Nozzle
Cabletec HDPE to HDPE Coupling:
1" - AS 1.315
1-1/2" - AS 1.900
2" - AS 2.375
3" - AS 3.500
4" - AS 4.500

HDPE to PVC Coupling:
1" - ASP 1.315
1-1/2" - ASP 1.900
2" - ASP 2.375
3" - ASP 3.500
4" - ASP 4.500
8/2/01




12/22/17
Dura-Line HDPE to HDPE Coupling or HDPE to PVC Coupling:
ShurLock Couplings
1" - 20000118
1 ½” – 20000122
2" - 20000123 (1-400761)
3" - 20000173
4" - 20000245
7/11/14 Side View
Label View
End View
Georg Fischer/Central Plastics Company HDPE to HDPE Electrofusion Couplings
1 ½” - 5760028
2” - 5760030
3” - 10000358
4” - 10000360
5/5/06

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Schedule 40 PVC Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Cantex 1” – A52BA12
1 ½” – A52BE12
2” – A52CA12
3” – A52DA12
4” – A52EA12
5/5/03
Heritage Plastics 1” – 511010 (10’ length)
1" - 511020 (20’ length)
1 ½” – 511510 (10’ length)
1 ½” - 511520 (20’ length)
2” – 512010 (10’ length)
2" - 512020 (20’ length)
3” – 513010 (10’ length)
3" - 513020 (20’ length)
4” – 514010 (10’ length)
4" - 515020 (20’ length)
7/24/12
IPEX / Scepter 1” – 032410 – 10’or 032411 – 20’
1 ½” – 032415 – 10’or 032416 – 20’
2” – 032420 – 10’ or 032421 – 20’
3” – 032430 – 10’ or 032431 – 20’
4” – 032440 – 10’ or 032441 – 20’
12/22/05
Prime Conduit 1” – 49008-010 (10’ length)
1” – 49008-020 (20’ length)
1 ½” – 49010-010 (10’ length)
1 ½” – 49010-020 (20’ length)
2” – 49011-010(10’ length)
2” – 40911-020 (20’ length)
3” – 49013-010 (10’ length)
3” – 49013-020 (20’ length)
4” – 49015-010 (10’ length)
4” – 49015-020 (20’ length)
5/26/09
Rocky Mountain Colby Pipe 1" – 504010010U (10' length)
1" – 504010020U (20' length)
1 1/2" – 504015010 (10' length)
1 1/2" – 504015020U (20' length)
2” – 504020010U (10’ length)
2" – 504020020U (20’ length)
3” – 504030010U (10’ length)
3" – 504030020U (20' length)
4” – 504040010U (10’ length)
4" – 504040020U (20’ length)
4/7/09
Comment:
Schedule 40

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Schedule 80 PVC Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Cantex 1” – A53BA12
1 ½” – A53BE12
2” – A53CA12
3" – A53DA12
4" – A53EA12
1/29/19
Heritage Plastics 1” – 9304 (10’ length)
1" – 9504 (20’ length)
1 ½” – 9306 (10’ length)
1 ½” – 9506 (20’ length)
2” – 9308 (10’ length)
2" – 9508 (20’ length)
3” – 9312 (10’ length)
3" – 9512 (20’ length)
4” – 9316 (10’ length)
4" – 9516(20’ length)
1/29/19
IPEX / Scepter 1” – 032510 (10’length)
1” – 032511 (20’ length)
1 ½” – 032515 (10' length)
1 ½” – 032516 (20' length)
2” – 032520 (10’length)
2" – 032521 (20’ length)
3” – 032530 (10’ length)
3" - 032531 (20’ length)
4” – 032540 (10’ length)
4" – 032541 (20’ length)
1/29/19
Prime Conduit 1” – 49408-010 (10’ length)
1” – 49408-020 (20’ length)
1 1/2" – 49410-010 (10' length)
1 1/2" – 49410-020 (20' length)
2” – 49411-010 (10’ length)
2” – 40911-020 (20’ length)
3” – 49413-010 (10’ length)
3” – 49413-020 (20’ length)
4" – 49415-010 (10' length)
4" – 49415-020 (20' length)
1/29/19
Rocky Mountain Colby Pipe 1" – 508010010U (10' length)
1" – 508010020U (20' length)
1 1/2" – 508015010 (10' length)
1 1/2" – 508015020U (20' length)
2” – 508020010U (10’ length)
2" – 508020020U (20’ length)
3” – 508030010U (10’ length)
3" – 508030020U (20' length)
4” – 508040010U (10’ length)
4" – 508040020U (20’ length)
1/29/19
Comment:
Schedule 80 PVC shall only be used in above ground applications or exposed on the underside of bridge decks.

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Schedule 40 PVC Fittings

Notes Manufacturer Catalog Number Approval Date Photos
Allied Tube & Conduit Standard Couplings:
 1” – 59603
 1 ½” – 59605
 2” – 59606
 3" – 59608
 4" – 59610

90º Elbows 36” Radius for Power:
(Plain End) / (Bell End)

 2” – 59730 / NA
90º Elbows: (Plain End / Belled End)
 1” – 59590 / 802754
 1 ½” – 59592 / 802756
 2” – 59593 / 807757
 3” – 59595 / 802759
 4" – 59597 / 802762
45º Elbows:(Plain End / Belled End)
 1” – 59577 / 802768
 1 ½” – 59579 / 802770
 2” – 59580 / 802771
 3” – 59582 / 802773
 4” – 59584 / 802775
30º Elbows: (Plain End / Belled End)
 1” – 59563 / 802780
 1 ½” – 59565 / 802782
 2” – 59566 / 802783
 3" – 59568 / 802785
 4” – 59570 / 802787

9/3/14
Cantex Standard Couplings:
1” – 6141625
1 ½” – 6141627
2” – 6141628
3” – 6141630
4” - 6141632

90º Elbows 36” Radius for Power:
(Plain End) / (Belled End)

2” – 5133848 / 5233848
90º Elbows: (Plain End / Belled End)
1” – 5133825 / 5233825
1 ½” – 5133827 / 5233827
2” – 5133828 / 5233828
3” – 5133830 / 5233830
4” – 5133832 / 5233832
45º Elbows: (Plain End / Belled End)
1” – 5133765 / 5233765
1 ½” – 5133767 / 5233767
2” – 5133768 / 5233768
3” – 5133770 / 5233770
4” – 5133772 / 5233772
30º Elbows: (Plain End / Belled End)
1” – 5133745 / 5233745
1 ½” – 5133747 / 5233747
2” – 5133748 / 5233748
3” – 5133750 / 5233750
4” – 5133775 / 5233776

5/5/03
Heritage Plastics Standard Couplings:
1” – 610002
1 ½” – 610004
2” – 610005
3” – 610007
4” – 610009

90º Elbows 36” Radius for Power:
(Plain End) / Belled End)

2” – 611353 / 611140
90º Elbows: (Plain End / Belled End)
1” – 611002 / 611058
1 ½” – 611004 /611060
2” – 611005 / 611061
3” – 611007 / 611063
4” – 611009 / 611065
45º Elbows: (Plain End / Belled End)
1” – 611016 / 611071
1 ½” – 611018 / 611073
2” – 611019 / 611074
3” – 611021 / 611076
4” – 611023 / 611078
30º Elbows: (Plain End / Belled End)
1” – 611030 / 611085
1 ½” – 611032 / 611087
2” – 611033 / 611088
3” – 611035 / 611090
4” – 611037 / 611092

7/24/12
IPEX / Scepter Standard Couplings:
1” – EC20 / 077003
1 ½” – EC30 / 077005
2” – EC35 / 077006
3” – EC45 / 077008
4” – EC55 / 077010

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

2” – 068765 / 068054
90º Elbows: (Plain End / Belled End)
1” – EE2090 / EE2090B
1 ½” – EE3090 / EE3090B
2” – EE3590 / EE3590B
3” – EE4590 / EE4590B
4” – EE5590 / EE5590B
45º Elbows: (Plain End / Belled End)
1” – EE2045 / EE2045B
1 ½” – EE3045 / EE3045B
2” – EE3545 / EE3545B
3” – EE4545 / EE4545B
4” – EE5545 / EE5545B
30º Elbows: (Plain End / Belled End)
1” – EE2030 / NA
1 ½” – EE3030 / NA
2” – EE3530 / NA
3” – EE4530 / NA
4” – EE5530 / NA
22.5º Elbows: (Plain End / Belled End)
1” – NA / NA
1 ½” – EE1522 / NA
2” – EE2022 / NA
3” – EE3022 / NA
4” – EE4022 / NA

12/22/05
Formerly Carlon Prime Conduit Standard Couplings:
1” – CP100
1 ½” – CP150
2” – CP200
3” – CP300
4” – CP400

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

2” – UA9FJ / UA9FJB
90º Elbows: (Plain End / Belled End)
1” – UA9AF / UA9AFB
1 ½” – UA9AH / UA9AHB
2” – UA9AJ / UA9AJB
3” – UA9AL / UA9ALB
4” – UA9AN / UA9ANB
45º Elbows: (Plain End / Belled End)
1” – UA7AF / UA7AFB
1 ½” – UA7AH / UA7AHB
2” – UA7AJ / UA7AJB
3” – UA7AL / UA7ALB
4” – UA7AN / UA7ANB
30º Elbows: (Plain End / Belled End)
1” – UA6AF / UA6AFB
1 ½” – UA6AH / UA6AHB
2” – UA6AJ / UA6AJB
3” – UA6AL / UA6ALB
4” – UA6AN / UA6ANB

5/26/09

Schedule 80 PVC Fittings

Notes Manufacturer Catalog Number Approval Date Photos
Allied Tube & Conduit Standard Couplings:
 1” – 59603
 1 ½” – 59605
 2” – 59606
 3" – 59608
 4" – 59610

90º Elbows 36” Radius for Power:
(Plain End / Bell End)

 2” – 597394 / 926011
90º Elbows: (Plain End / Belled End)
 1” – 59014 / 924949
 1 ½” – 59016 / NA
 2” – 59017 / 924970
 3” – 59019 / 924993
 4” – 59021 / 925006
45º Elbows:(Plain End / Belled End)
 1” – 59002 / NA
 1 ½” – 59004 / 903486
 2” – 59005 / 924967
 3” – 59007 / 924990
 4" – 59009 / 925006
30º Elbows: (Plain End / Belled End)
 1” – 59066 / NA
 1 ½” – 59068 / NA
 2” – 59069 / NA
 3" – 59071 / NA
 4” – 59072 / NA

1/29/19
Cantex Standard Couplings:
 1” – 6141625
 1 ½" – 6141627
 2” – 6141628
 3" – 6141630
 4" – 6141632

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

 2” – 5121021 / 5121047
90º Elbows: (Plain End / Belled End)
 1” – 5121055 / NA
 1 ½” – 5121057 / 5221057
 2” – 5121058 / 5221058
 3” – 5121060 / 5221060
 4” – 5121061 / 5221061
45º Elbows:(Plain End / Belled End)
 1” – 5121005 / NA
 1 ½” – 5121007 / 5221007
 2” – 5121008 / 5221008
 3” – 5121010 / 5221010
 4” – 5121011 / 5221011
30º Elbows: (Plain End / Belled End)
 1” – 5121002 / NA
 1 ½” – 5121850 / NA
 2” – 5121108 / NA
 3" – 5121110 / NA
 4” – 5121111 / NA
22.5º Elbows: (Plain End / Belled End)
 1” – NA / NA
 1 ½” – 5136649 / NA
 2” – 5136659 / 5221052
 3" – 5136679 / 5236679
 4” – 5121868 / 5221868

1/29/19
Heritage Plastics Standard Couplings:
 1” – 59603
 1 ½" – 59605
 2” – 59606
 3” – 59608
 4" – 59610

90º Elbows 36” Radius for Power:
(Plain End) / (Belled End)

 2” – 597394 / 926011
90º Elbows: (Plain End) / (Belled End)
 1” – 59014 / 924949
 1 ½" – 59016 / NA
 2” – 59017 / 924970
 3" - 59019 / 924993
 4" – 59021 / 925006
45º Elbows: (Plain End) / (Belled End)
 1” – 59002 / NA
 1 ½" – 59004 / 903486
 2” – 59005 / 924967
 3” – 59007 / 924990
 4" – 59021 / 925003
30º Elbows: (Plain End) / (Belled End)
 1” – 59066 / NA
 1 ½" – 59068 / NA
 2” – 59069 / NA
 3” – 59071 / NA
 4" – 59072 / NA

1/29/19
IPEX / Scepter Standard Couplings:
 1” – EC20
 1 ½” – ED30
 2” – EC35
 3” – EC45
 4" – ED55

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

 2” – 068775 / NA
90º Elbows: (Plain End / Belled End)
 1” – 80EE2090 / NA
 1 ½” – 80EE3090 / NA
 2” – 80EE3590 / NA
 3” – 80EE4590 / NA
4" - 80EE5590 / NA
45º Elbows: (Plain End / Belled End)
 1” – 80EE2045 / NA
1 ½” – 80EE3045 / NA
 2” – 80EE3545 / NA
 3” – 80EE4545 / NA
4" – 80EE5545 / NA
30º Elbows: (Plain End / Belled End)
 1” – 80EE2030 / NA
1 ½” – 80EE3030 / NA
 2” – 80EE3530 / NA
 3” – 80EE4530 / NA
4" – 80EE5530 / NA

1/29/19
Prime Conduit Standard Couplings:
 1” – CP100
 1 ½” – CP150
 2” – CP200
 3" – CP300
 4” – CP400

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

 2” – UB9FJ / UB9FJB
90º Elbows: (Plain End / Belled End)
 1” – UB9AF / UB9AFB
 1 ½” – UB9AH / UB9AHB
 2” – UB9AJ / UB9AJB
 3” – UB9AL / UB9ALB
 4” – UB9AN / UB9ANB
45º Elbows: (Plain End / Belled End)
 1” – UB7AF / UB7AFB
 1 ½” – UB7AH / UB7AHB
 2” – UB7AJ / UB7AJB
 3” – UB7AL / UB7ALB
 4” – UB7AN / UB7ANB
30º Elbows: (Plain End / Belled End)
 1” – UB6AF / UB6AFB
 1 ½” – UB6AH / UB6AHB
 2” – UB6AJ / UB6AJB
 3” – UB6AL / UB6ALB
 4” – UB6AN / UB6ANB
22.5º Elbows: (Plain End / Belled End)
 1” – UB5AF / UB5AFB
 1 ½” – UB5AH / UB5AHB
 2” – UB5AJ / UB5AJB
 3” – UB5AL / UB5ALB
 4” – UB5AN / UB5ANB

1/29/19
Comment:
To be used with Schedule 80 PVC conduit

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

RMC Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Allied Tube & Conduit 1” – 278895
1 ½” – 278911
2” – 278929
3” – 278945
4” – 278960
5/5/03
Sawhill Tubular Division Steelduct
1” – 662535-19345-1
1 ½” – 662535-19347-5
2” – 662535-19349-9
3” – 662535-19351-2
4” – 662535-19353-6
4/11/00
Western Tube & Conduit Corp 1” – WTR3
1 ½” – WTR5
2” – WTR6
3” – WTR8
4” – WTR91
5/5/03
Wheatland Tube 1” – 05440
1 ½” – 05442
2” – 05443
3” – 05445
4” – 05447
5/5/03
Comment:
Galvanized Rigid Conduit
Used only for extension of existing RMC conduit



Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

RMC Fittings

Notes Manufacturer Catalog Number Approval Date Photos
Conduit Pipe Products Coupling Part Numbers
1 ½” – 00135
2” – 00136
3” – 00138
4” – 00140
90º Elbow Part Numbers
1 ½” – 00165
2” – 00166
3” – 00168
4” – 00170
45º Elbow Part Numbers
1 ½” – 00185
2” – 00186
3” – 00188
4” – 00190
5/5/03
Picoma Industries Couplings, 90º Elbow and 45º Elbow in sizes:
1 ½”, 2”, 3”, 4”
5/5/03
Sawhill Tubular Division Steelduct (Right and Left Threaded)
Coupling Part Numbers
4”x4” – 20997
4/10/01
Sawhill Tubular Division 90º Elbow Part Numbers
3” – 21276
4” – 21279
45º Elbow Part Numbers
3” – 21271
4” – 21273
4/11/00
Shamrock Conduit Products Coupling Part Numbers
1 ½” – 9001
2” – 0319
3” – 0321
4” – 0323
90º Elbow Part Numbers
1 ½” – 7746
2” – 7747
3” – 7749
4” – 7751
45º Elbow Part Numbers
1 ½” – 7654
2” – 7655
3” – 7657
4” – 7659
5/5/03
Comment:
Galvanized Rigid Conduit fittings
Used only for extension of existing RMC conduit

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

RMC Bushings

Notes Manufacturer Catalog Number Approval Date Photos
Arlington Industries 1 ½” – 454
2” – 455
3” – 457
4” – 459
1/11/02
Bridgeport 1 ½” – 385
2” – 386
3” – 388
4” – 390
5/5/03
Lazy-lug 1” – GLL-3C-B
1 ½” – GLL-5C-B
2” – GLL-6C-B
3” – GLL-8C-B
4” – GLL-10C-B
5/5/03
OZ-Gedney 1” – IBC-100L-4AC
1 ½” – IBC-150L-4AC
2” – IBC-200L-4AC
3” – IBC-300L-4AC
4” – IBC-400L-4AC
7/2/03
Regal Manufacturing 1 ½” – 8225
2” – 8226
3” – 8228
4” – 8230
5/5/03
Steel City / Thomas & Betts 1 ½” – BG-805
2” – BG-806
3” – BG-808
4” – BH-810
5/5/03
Comment:
Copper lug with insulated throat constructed of malleable iron.
Threaded type

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Bridge Expansion Couplings

Notes Manufacturer Catalog Number Approval Date Photos
Allied Tube & Conduit 1" - 789648
1 ½” - 789650
2" - 789651
3" - 789653
4" - 789655
5/2/14
Cantex 1” – 5144033
1 ½” – 5144035
2” – 5144036
3” – 5144038
4” – 5144040
5/5/03
IPEX / Scepter 1” – EJ20
1 ½” – EJ30
2” – EJ35
3” – EJ45
4” – EJ55
9/26/13
Prime Conduit 1” – EC2PC100
1 ½” – EC2PC150
2” – EC2PC200
3” – EC2PC300
4” – EC2PC400
9/26/13

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Controller Cabinet

ATC Single Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
For HAWK Signals Only McCain 352i 11/15/18 Front View
Comment:
Inlcudes the following:
24 channel input assembly
16 channel output assembly
Single two-door cabinet
8" cabinet riser
Corbin Locks
MOV's for field outputs
Rear mounted field output terminals and field input terminal panels
Rear facing panel terminals for pedestrian and EVP
One shelf

332 Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
McCain Model 332 / M35378 10/12/11

332 Single Input File Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use
Only/or as Specified
McCain Model OP332SI w/ slide out battery drawer UPS Battery Drawer 6 10/12/11

333 Double Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
McCain Model 333JP-OPKS 6/16/10
Comment:
These should be fabricated to “Overland Park Special” configurations

Hybrid Double Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use Only Safetran Model 333SD Hybrid-OPKS
STCAB2663-L w/Rev C – Std Brushed Alum.

8” Base Adapter Riser:
Drawing No. 025557D333-00 w/Rev C
10/6/11 Front View
Back View
Field Terminal Panel
Output Loadbay
Power Panel Front
Power Panel Back
Detector Interface Panel
Cabinet Fans
Comment:
Reliance Controls Corp (30 A, 4-prong) External Generator Receptacle if specified

Hybrid Single Stretch Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use Only Safetran Model 332 Stretch-OPKS
8" Base Adapter Riser
Comment:
Reliance Controls Corp (30 A, 4-prong) External Generator Receptacle if specified

334 Pad Mount DMS Sign Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
Safetran Model 334-OPKS 5/5/03

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Detection Systems

Microloop Probes

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies bought out 3M Global Traffic Technologies
/ 3M / Canoga
Model 701 w/40004
Micro loop Cable
2/18/08

Non-Invasive Vehicle Detectors Probes

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies bought out 3M Global Traffic Technologies
/ 3M
Model 702 Probes and Carriers
Model 702 Installation Kit
Canoga C800 Interface
Scotchcast 3832 Splice Kit
2/18/08

Pedestrian Pushbuttons ADA Audible

Notes Manufacturer Catalog Number Approval Date Photos
Polara Engineering, Inc. iNavigator 3-Wire APS
iN33TN1-X Push Button Station w/ 9”x15” frame

Accessories
iN-EXT-LL-PC-X Straight Mounting Extender
iN-EXTANG-LL-PC-X Angled Mounting Extender
iN-EXTHTRED-PC-X Curved Mounting Extender
iNPBF2S-4.5-PC-X Dual Mounting Bracket
iN-90DEGADPTR-PC-X 90-Degree Adaptor
Station Front View
Station Cover Removed
For Maintenance Use
Only/or as Specified
Polara Engineering, Inc. EZ Communicator Navigator 4-Wire APS
9”x15” frame – EN43TN1-PY (std pole)
PHCU4W - Included Power Unit
NPA4X2-y (adapter for pedestal pole)
800H-84 - Sign Option
Optional Sound Baffle: ENAV-SB
Optional Frame Extender: 6" - PBFE-06 or 12" PBFE-12
1/23/13 Front View
Button
Back View
Comment:
Red LED indicator
Audible locator
Auto volume adjustment for ambient noise levels
Custom Message (Recorded at Factory w/ electronic copy sent to City)
LL = Length of Extension: 06 for 6" or 12 for 12"
X = Color: B for Black or Y for Yellow.

For standard signal poles, the color of the frame, bracket, and adapter, if used, shall be powder coated yellow. The extender shall remain galvanized with no color.
For decorative signal poles, the color of the extender, frame, bracket, and adapter, if used, shall be powder coated black.

Pedestrian Pushbuttons

Notes Manufacturer Catalog Number Approval Date Photos
Polara Engineering, Inc. Bulldog Series
Push Button Assembly: BDSP-010-X

Pole Mount Adaptor: BDPM3-X

Accessories For Maintenance Use Only/or as Specified
Push Button Frame 2C with 9"x15" Plate Adapter: PBF2C-9x15-X
Straight Mounting Extender: iN-EXT-LL-PC-X
Angled Mounting Extender: iN-EXTANG-LL-PC-X
Curved Mounting Extender: iN-EXTHTRED-PC-X
Dual Mounting Bracket: iNPBF2S-4.5-PC-X
90-Degree Adaptor: iN-90DEGADPTR-PC-X
1/26/15
Comment:
Yellow body with sound on actuation
NO LED Flash
LL = Length of Extension: 06 for 6" or 12 for 12"
X = Color: B for Black or Y for Yellow.

For standard signal poles, the color of the frame, bracket, and adapter, if used, shall be powder coated yellow. The extender shall remain galvanized with no color.
For decorative signal poles, the color of the extender, frame, bracket, and adapter, if used, shall be powder coated black.

Emergency Vehicle Pre-empt (EVP) Detectors

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies Model 721 2/218/08 Side View
Cable Terminal
Comment:
Two Direction Single Channel

Pre-formed Detector Loop

Notes Manufacturer Catalog Number Approval Date Photos
Never-Fail Loop Systems Model A – in or under asphalt
Model C – in concrete or bridge decks
6/6/00
Patriot Detection Model CG16MM 9/1/15
Reno Rectangular Loop: Model PLH-XX-YY
Quadrupole Loop: Model PLH-XX-YY-ZZ
7/7/16

Advance Radar Detectors

Notes Manufacturer Catalog Number Approval Date Photos
Wavetronix Model WX-SS-200V SmartSensor Advance Unit
SDLC Cabinet Interface Device
4 Terminal Ports: 102-0416 (WX-CLK-650)
6 Terminal Ports: 102-0451 (WX-CLK-656)
1/10/11 SDLC Module Wire Plug
4-Terminal Port SDLC Module
SDLC Module Front View
SDLC Module Back View
SDLC Module Side View
6-Terminal Port SDLC Module
SDLC Module Front View
SDLC Module Back View
Comment:
Include the SDLC Cabinet Interface Module
Select appropriate SDLC Cabinet Interface Module for 4 or 6 sensors

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Presence Radar Detectors

Notes Manufacturer Catalog Number Approval Date Photos
Wavetronix Model WX-SS-225 SmartSensor Matrix Presence Unit
SDLC Cabinet Interface Device
4 Terminal Ports: 102-0416 (WX-CLK-650)
6 Terminal Ports: 102-0451 (WX-CLK-656)
5/30/13 Sensor Front View
Sensor Back View
Sensor Top View
Sensor Bottom View
Sensor Cable Ports
SDLC Module Wire Plug
4-Terminal Port SDLC Module
SDLC Module Front View
SDLC Module Back View
SDLC Module Side View
6-Terminal Port SDLC Module
SDLC Module Front View
SDLC Module Back View
Comment:
Include the SDLC Interface Module
Select appropriate SDLC Cabinet Interface Module for 4 or 6 sensors

Vehicle Detectors (Loops)

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies
bought out 3M
Global Traffic Technologies
/ 3M / Canoga
Model C922 – Two Channel
Model C924 – Four Channel
2/18/08
Reno Model C-1200-SS Series – Two Channel
Model E-1200-SS Series – Four Channel
2/10/12
Comment:
It shall have TS2 status output available

Video Detection Systems

Notes Manufacturer Catalog Number Approval Date Photos Comments
Used for Maintenance Replacements Only Econolite/Autoscope Encore MVP Image Sensor: AENCORENP
Interface Panel: ATIP1
Access Point: ATAPE
Interface Cable Kit: ASTCBL10
SDLC Cable Harness: 33550G5
9/11/13 Easy-Lock Harting Connector
On-Board Ethernet Port
SDLC Cable Harness for TS-2 Comm to ASC/3 – Rack Mount Controller
Used for Maintenance Replacements Only Econolite/Autoscope Terra Rack Vision AIS Image Sensor: AIS4HCRZOOMU0S
Camera Interface Panel: AIPx
Coaxial Jumper Cable: RG59
Processor Card: ARVTERRA1E
SDLC Cable Harness: 33550G5
5/17/07 Easy-Lock Harting Connector
x = number of cameras to be connected to the interface panel (1 to 6)
On-Board Ethernet Port
Used for Maintenance Replacements Only ITS PLUS3, Inc. Advanced VIVDS Camera: ITSP-PM120C

Dual Channel VIVDS Card w/ Ethernet: ITSP-V200E
4 Way Coax Surge Suppression Panel: ITSP-SSP-4
SDLC Module: ITSP-SDLC
Siamese Coax/Power Cable: ITS-Cable

1/27/17 Camera Front
Detection Card

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Grounding Equipment

RJ-45 Data Protector

Notes Manufacturer Catalog Number Approval Date Photos
Atlantic Scientific was purchased
by Cooper/Crouse Hinds
Cooper/Crouse Hinds Zonebarrier-24585 7/11/12
Protection Technology Group / Transector Model: TSJ-GbE PoE
Part Number: 1101-994
2/11/14 Top View
Side View
Comment:
Use with IP High Definition CCTV Cameras

Ground Rod

Notes Manufacturer Catalog Number Approval Date Photos
Erico Inc. 5/8” x 8’-0” Cat. No. 615880
5/8” x 10’-0” Cat. No. 615800
2/27/02
Galvan Industries 5/8" x 8'-0" Cat. No. 6258
5/8" x 10'-0: Cat. No. 6260
12/20/13
Hubbell 5/8" x 8’-0” Cat. No. C615880
5/8” x 10’-0” Cat No. C635800
4/24/12
Thomas & Betts 5/8” x 8’-0” Cat. No. 6258
5/8” x 10’-0” Cat No. 6260
5/5/03
Comment:
5/8” x 10’-0” long at poles and controller cabinet
5/8” x 8’-0” long at service boxes
Copper clad steel core
UL listed

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Ground Rod Clamp

Notes Manufacturer Catalog Number Approval Date Photos
Burndy GRC58 – 5/8” 2/27/02 Clamp
Erico Inc. HDC58 – 5/8” 12/1/05
Galvan Industries SRC – 5/8” 12/20/13
Thomas & Betts JAB58H - 5/8" 5/5/03
Comment:
Hex head set screw
Copper alloy
Long bearing surface
UL listed

Junction and Service Boxes

Type 1 Junction Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001423TA – Assembly
A6001422T – Cover only
A6001423 – Box only
1/11/01
Highline Product Number Nomenclature
PHB121212 – Box only
CHC1212HS – Cover only
PHA121212HS2 – Assembly
3/3/11 Side View
Top View
Bottom View
Martin Enterprises 121212PCC – Box only
1212PCC – Cover only
121212PC – Assembly
10/17/11 Side View
Top View
Cover
Bolt Hole
New Basis Cover Label
PCB121212-00000 – Box only
PCC1212PC1-90005 – Cover only
PCA121212-00030 - Assembly
8/8/03 Side View
Top View
Cover
Bolt Hole
Carson H Series boxes were
purchased by Oldcastle
Oldcastle Part Numbers
12122001 – Box only
12124010 – Synertech Cover only
12121610 – Assembly
80002033 hex head bolts if separate
6/5/14 Cover
Quazite was purchased
by Hubbell Power Systems
Quazite PC1212BA12 – Box only
PC1212HA0046 – Cover only
PC1212Z50346 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
1 Piece cover to be ¾” min thick
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Type 2 Junction Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001429TA - Assembly
A6001428T – Cover only
A6001429 – Box only
7/30/01 Side View
Top View
Bottom View
Highline Product Number Nomenclature
PHB111812 – Box only
CHC1118SS – Cover only
PHA111812SS2 - Assembly
3/3/11 Side View
Top View
Cover
Bottom View
Martin Enterprises 111812PCB – Box only
1118PCC – Cover only
111812PC – Assembly
10/17/11
New Basis Cover Label
PCB111812-00000 – Box only
PCC11181P1-90019 – Cover only
PCA111812-00030 - Assembly
8/8/03 Side View
Top View
Cover
Carson H Series boxes were
purchased by Oldcastle
Oldcastle Part Numbers
11182001 – Box only
11184611 – Cover only
11181613 – Assembly
80002033 hex head bolts if separate
8/29/13 Side View
End view
Cover
Quazite was purchased
by Hubbell Power Systems
Quazite PG1118BA12 – Box only
PG1118HA0046 – Cover only
PG1118Z50946 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
1 Piece cover to be 2” thick
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Type 1 Service Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001974TAPCX24 - Assembly
A6001975T – Cover only
A6001974PCX24 – Box only
7/30/01 End View
Top View
Bottom View
Channell Commercial Corp BULKU243624F061010 - Assembly
BULKUA2436E061010 - Cover only
BULKUA2436240 - Box only
8/5/16 Cover Ground Wire
Highline Product Number Nomenclature
PHB243624 – Box only
CHC2436HS – Cover only
PHA243624HS2 – Assembly
3/3/11 Side View
End View
Bolt Hole
Martin Enterprises 243624PCB – Box only
2436PCC – Cover only
243624PC - Assembly
10/17/11 Side View
End View
Cover
Bolt Hole
New Basis Cover Label
PCB24362400000 – Box only
PCC2436P1-00030 – Cover only
PCA243624-00030 – Assembly
2/26/02
Carson H Series boxes were
purchased by Oldcastle
Oldcastle Part Numbers
24362214 – Box only
24364613 – Cover only
24361616 – Assembly
80002029 hex head bolts if separate
8/29/13 Side View
End View
Cover
Bolt Hole
Quazite was purchased
by Hubbell Power Systems
Quazite PG2436BA24 – Box only
PG2436HA0046 – Cover only
PG2436Z50246 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
1 Piece cover to be 3” thick
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Type 2 Service Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001430TAPCX24 – Assembly
A6001470T (2 pc. Req.) – Cover only
A6001430PCX24 – Box only
7/30/01 Side View
End View
Channell Commercial Corp BULKU304824F081010 - Assembly
BULKUA3048E081010 - Cover Only
BULKUA3048240 - Box only
8/5/16 Cover Ground Wire
Highline Product Number Nomenclature
PHB304824 – Box only
CHC3048HS-2PC – Cover only
PHA304824HS4 – Assembly
3/3/11
Martin Enterprises 304824PCB – Box only
3048PCC – Cover only
304824PC - Assembly
10/17/11
New Basis Cover Label
PCB30482400000 – Box only
PCC3048P2-90039 – Cover only
PCA304824-00062 – Assembly
2/26/02 Side View
Carson H Series boxes were
purchased by Oldcastle
Oldcastle Part Numbers
30482021 – Box only
30484611 – Cover only
30481618 – Assembly
80002029 hex head bolts if separate
8/29/13 Side View
End View
Top View
Cover
Bolt Hole
Quazite was purchased
by Hubbell Power Systems
Quazite PG3048BA24 – Box only
PG3048HS0046 – Cover only
PG3048Z52546 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
2 Piece cover to be 3” thick underlapping
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

LED Units

Red LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 432-1314-001XOD 4/30/10 Front View
Back View
GE GTX Series: DR6-RTAAN-VLA 12/8/16
Leotek TSL-12RA-IL6-A1-P3 4/3/18 Front View
Back View
Label
Comment:
Tinted lens
Incandescent look

Yellow LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 431-3334-901XOD 4/30/10
GE GTX Series: DR6-YTAAN-VLA 12/8/16
Leotek TSL-12YA-IL6-A1-P3 4/3/18 Front View
Back View
Label
Comment:
Tinted lens
Incandescent look

Green LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 432-2324-001XOD 4/30/10 Front View
Wiring
GE GTX Series: DR6-GTAAN-VLA 12/8/16
Leotek TSL-12GA-IL6-A1-P3 4/3/18 Front View
Back View
Label
Comment:
Tinted lens
Incandescent look

Bi-Modal Green/Yellow LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 430-6370-001 4/30/10
GE DR6-ECA6-21A 12/8/16
Leotek TSL-12BM-LD-A1 4/3/18 Front View
Back View
Label
Comment:
Clear Lens, pixilated arrow

Red Ball LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight DuraLED 433-1210-003XL 4/30/10
GE GTX City Series: DR6-RTFB-VLA 12/8/16
Leotek TSL-12R-LX-IL6-A1-P3 4/3/18 Front View
Back View
Label
Comment:
Tinted lens
Incandescent look

Yellow Ball LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight DuraLED 433-3230-901XL 4/30/10
GE GTX City Series: DR6-YTFB-VLA 12/8/16
Leotek TSL-12Y-LX-IL6-A1-P3 4/3/18 Front View
Back View
Label
Comment:
Tinted lens
Incandescent look

Green Ball LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight DuraLED 433-2220-001XL 4/30/10
GE GTX City Series: DR6-GTFB-VLA 12/8/16
Leotek TSL-12G-LX-IL6-A1-P3 4/3/18 Front View
Back View
Label
Comment:
Tinted lens
Incandescent look

Countdown Pedestrian LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 430-6479-001X 4/30/10
GE GTX City Series: PS7-CFF1-VLA 12/8/16 Front View
Back View
Gasket
Countdown View
Leotek TSL-PED-16-SPC-V1 4/3/18 Front View
Label
Back View
Comment:
16” X 18” Orange Hand/White Man
Incandescent look
Filled/Overlay Style
9” Numerals

Loop Sealants

Notes Manufacturer Catalog Number Approval Date Photos
3M 5000 5/5/03
Purchased by Royal Adhesives & Sealants
Under acquisition by HB Fuller
Chemque Q-Seal 290S - Grey or Black 10/23/03
Crafco Inc RoadSaver 221, Part No. 34221 5/5/03
Ruscoe Highway Products Permanent Sealer 974 – Gray or Black 7/3/13

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Miscellaneous Controller Equipment

ATC Cabinet Specific Equipment

ATC Controller

Notes Manufacturer Catalog Number Approval Date Photos
McCain ATC eX 2070 PN: M46541 10/16/18
Comment:
Used only in ATC Cabinet
With Data Key
Firmware shall be provided with the controller

ATC Cabinet Power Supply

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc PS-2216-24-HV 10/16/18
Comment:
Used only in ATC Cabinet.

Auxiliary Display Unit (ADU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. ADU 10/16/18
Comment:
Used only in ATC Cabinet

Cabinet Monitor Unit (CMU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. CMUip-2212-HV 10/16/18
Comment:
Used only in ATC traffic signal cabinet in place of the conflict monitor

Flasher

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. 2202-HV 10/16/18
Comment:
Used only in ATC Cabinet.
Part is also used for the High Density Switch Pack / Load Switch in ATC Cabinet

High Density Flash Transfer Relay

Notes Manufacturer Catalog Number Approval Date Photos
Struthers-Dunn 21XBXHL-48VDC 10/16/18
Comment:
Used only in ATC Cabinet.

High Density Switch Pack / Load Switch

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. 2202-HV 10/16/18
Comment:
Used only in ATC Cabinet.
Part is also used for the Flasher in ATC Cabinet

Serial Interface Unit (SIU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. SIU-2218 10/16/18
Comment:
Only used in ATC Cabinet

General Cabinet Equipment

1C CPU Module

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Model 2070-1C 2/15/17
Comment:
For use in upgrading existing ATC 2070 controllers only

AC Isolator

Notes Manufacturer Catalog Number Approval Date Photos
GDI Communications ACIM252 5/5/03
PDC / Power Distribution & Control ACI-88 Model 252 5/5/03
Comment:
Model 252

Conflict Monitor

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design, Inc. 2018 KCLip – (Std 332 Cabinet) with
Datakey programming and Ethernet port
2/19/09 Front View
Side View
Comment:
Not used with Hybrid Cabinet. See “Malfunction Management Unit” below
Not used with ATC Cabinet. See “Conflict Management Unit” below

Controller

Notes Manufacturer Catalog Number Approval Date Photos
For Hybrid and 332 Cabinets Safetran/Econolite Control Products, Inc. Model Cobalt-C 2/26/16 Front View
Back View
Comment:
With Data Key
Firmware shall be provided with the controller

DC Isolator

Notes Manufacturer Catalog Number Approval Date Photos
GDI Communications DIM242 5/5/03
PDC / Power Distribution & Control DCI-82 Model 242 5/5/03 Front View
Side View
Comment:
Model 242
Not used with Hybrid Cabinet. See “Detector Test Switch Module” below.

Flash Transfer Relay

Notes Manufacturer Catalog Number Approval Date Photos
CII was acquired by Tyco Electronics CII Technologies / MidTex MidTex 136-62T3A1 5/5/03
Magnecraft W21ACPX-2 5/5/03
Reno A&E TR-200 11/3/05
Comment:
Model 430
Not used with ATC Cabinet. See “High Density Flash Transfer Relay” below

Flasher Unit

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design, Inc. EDI 204 5/5/03
GDI Communications FL204 5/5/03
PDC / Power Distribution & Control SSF-88 5/5/03
Reno A&E FL-200 11/3/05
TSC / Traffic Sensor Corp TSC 204 5/5/03
Comment:
Model 204
Not used with ATC Cabinet. See “High Density Switch Pack” below

Power Distribution Assembly (PDA)

Notes Manufacturer Catalog Number Approval Date Photos
McCain PDA#2 M63186 7/14/10
SafeTran

Power Distribution Surge Protection Unit

Notes Manufacturer Catalog Number Approval Date Photos
MTL Instruments Group
is the umbrella company
Cooper/Crouse-Hinds/
Atlantic Scientific
RP35326 10/28/2008 Front View
Back View
Top View
Indicator Lights
Geist Manufacturing, Inc. SPX084-10 11/4/05
Comment:
Room for 8 transformer spaced outlets (minimum)
15 amp breaker
Rack mounted
NEMA 5-15

Power Supply

Notes Manufacturer Catalog Number Approval Date Photos
EDI Model 206L 7/9/10
Comment:
High efficiency power saving w/ solid state transfer relay

Pre-empt Phase Selectors / Discriminator Module

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies Model 762 – Two Channel
Model 764 – Four Channel
Model 768 Auxiliary Interface Panel (If specified)
4/19/11 764 Phase Selector
Comment:
With Ethernet Ports

Switchpack / Load Switch

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design, Inc. EDI 200 5/5/03
GDI Communications LS200 5/5/03
PDC / Power Distribution & Control SSS-88 5/5/03
Reno A&E LS-200 11/3/05 Front View

Side View
Back View
End View
Label

TSC / Traffic Sensor Corp TSC200 5/5/03
Comment:
Model 200
Not used with ATC Cabinet. See “High Density Switch Pack” above

Surge Protector (Traffic Signal Cabinet)

Notes Manufacturer Catalog Number Approval Date Photos
Edco/Emerson Network Power SHA-1250 w/ SHA-1250-BASE-A 8/5/10
Hesco/RLS HE1750 10/16/18
Comment:
For Hybrid, 332 and ATC Cabinets

Utility Power Surge Protector (Secondary Service Enclosure)

Notes Manufacturer Catalog Number Approval Date Photos
Partners with Pentair Engineered
Electrical & Fastening Systems
Erico / Critec TDX-100S120240 11/26/14 Top View
Pull Out Drawer
Top Inside View
Replacement Module
Comment:
Note: NEMA-4 weather tight housing
Output contacts
Replaceable cartridge overcurrent fuse protection
Replaceable modules
Event timer

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Hybrid Cabinet Specific Equipment

Bus Interface Unit (BIU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. BIU-700H 10/17/18
Econolite 160-1003-505 10/6/11 Front View
Side View
Comment:
½ width design - Only used with Hybrid Cabinet

Malfunction Management Unit (MMU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. MMU2-16-LE(ip) 1/10/13 Front View
Back View
Comment:
Only used in Hybrid traffic signal cabinet in place of the conflict monitor

K1 Control Relay

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Dwg No. 54408 Rev U 4/6/15
Tyco Electronics /
Potter & Brumfield
KRPA-14AGP-120 2/10/11 Side View
Comment:
Only used with Hybrid Cabinet

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Mounting Brackets

Mast Arm Signal Head Bracket

Notes Manufacturer Catalog Number Approval Date Photos
Pelco AG-0125-1-LL-SS-PXX (1-Section)
AG-0125-3-LL-SS-PXX (3-Section)
AG-0125-4-LL-SS-PXX (4-Section)


AG-0168-LL-SS-PXX (HAWK)
4/19/19






4/19/19
Open Hinge View
Top View
Side View
A Division
of Olson
Aluminum
Castings
Sky Bracket SS-SBLL-18 (1-Section)
SS-SBLL-46 (3-Section)
SS-SBLL-60 (4-Section)


SS-SBLL_HPB-18 (HAWK)
1/11/19



1/11/19
Shown with previously approved cable mounting system.
Front View
Side View
Back View
Lower Arm
Upper Arm
Tube Section
Comment:
Stainless steel banding/cable and hardware
For Pelco:
Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
62" – for mast arm diameters ranging from 2” to 7”
84" – for mast arm diameters ranging from 7.1” to 10.5”
96" – for mast arm diameters ranging from 10.6” to 12.4”
110" – for mast arm diameters ranging from 12.5” to 14.6”
120" – for mast arm diameters ranging from 14.7” to 16.2”
132" – for mast arm diameters ranging from 16.3” to 18.2”
Color (XX) shall be as follows:
NC - No Color
33 - Glossy Black
71 - RAL6012 Green
39 - RAL8019 Dark Bronze
For Sky Bracket:
Required band length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
29” – for mast arm diameters ranging from 2” to 7”
42” – for mast arm diameters ranging from 8” to 11”
59” – for mast arm diameters ranging from 12” to 17”
If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat

Mini Pre-empt Detector Bracket

Notes Manufacturer Catalog Number Approval Date Photos
Pelco Products, Inc. Astro Brac AB-0155-L-SS-PNC 1/11/19
Comment:
Stainless Steel banding mount
L = Banding Length (29” or 42”)
PNC = Process No Color

Radar Detector Mounting Bracket

Notes Manufacturer Catalog Number Approval Date Photos
Pelco Inc. SP-5987-TT-LL-SS-PXX 8/6/19 Open Hinge View
Top View
Side View
A Division
of Olson
Aluminum
Castings
Sky Bracket Bracket: SS-SBLL-RCM-XX
Burle Style Adapter Plate: SB-PLT
1/11/19 Showing previously approved cable mounting system.
Front View
Side View
Back View
Mounting End
Tube Section
Wavetronix WX-SS-611 4/29/16 Top View
Side View
Connection Segments
Comment:
Stainless steel banding/cable and hardware
For Pelco:
Tube Length (TT) to be determined per plans
Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
62" – for mast arm diameters ranging from 2” to 7”
84" – for mast arm diameters ranging from 7.1” to 10.5”
96" – for mast arm diameters ranging from 10.6” to 12.4”
110" – for mast arm diameters ranging from 12.5” to 14.6”
120" – for mast arm diameters ranging from 14.7” to 16.2”
132" – for mast arm diameters ranging from 16.3” to 18.2”
Color (XX) shall be as follows:
NC - No Color
33 - Glossy Black
71 - RAL6012 Green
39 - RAL8019 Dark Bronze
For SkyBracket:
Required banding length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
29” – for mast arm diameters ranging from 2” to 7”
42” – for mast arm diameters ranging from 8” to 11”
59” – for mast arm diameters ranging from 12” to 17”
If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat

Side Mount Signal Head and Pedestrian Signal Head Bracket

Notes Manufacturer Catalog Number Approval Date Photos
Auto/Eagle UKS-1452X 5/5/03
Component Products, Inc. TSP880-X 5/5/03
Gades UKS1452X / PDM-405 5/5/03
Comment:
Yellow polycarbonate
X=Y for Yellow
X= B for Black

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Poles

Aluminum Pedestal Poles

Notes Manufacturer Catalog Number Approval Date Photos
Component Products, Inc Square Pedestal Base: CPI-BAS-1-P

Pole Cap: CPI-APC-1
9’ Pedestal Pole: CPI-AP-9-40
13’ Pedestal Pole: CPI-AP-13-40
14’ Pedestal Pole: CPI-AP-14-40

Base Collar: CPI-RBC-1

4/24/14 Base
Gades Sales Square Pedestal Base: PB-5335-1S-GL-PNC

Pole Cap: PB-5402-PNC
9’ Pedestal Pole: PB5100-9-PNC
13’ Pedestal Pole: PB5100-13-PNC
14’ Pedestal Pole: PB5100-14-PNC

Base Collar: PB-5325-PNC

4/24/14 Side View
Bottom View
Threaded Opening
Cover
Pelco Products, Inc. Square Pedestal Base: PB-5335-1S-GL-PNC

Pole Cap: PB-5402-PNC
9’ Pedestal Pole: PB-5100-9-PNC
13’ Pedestal Pole: PB-5100-13-PNC
14’ Pedestal Pole: PB-5100-14-PNC

Base Collar: PB-5325-PNC

4/23/14 Base
Base & Collar
Comment:
See "Anchor Bolts" for part number information
Pole tube is schedule 40
Include base collar with every pole
Set screws required in base collar
Include 2 7/8” OD x 7/8” ID galvanized flat washers
Include anchor bolts

Galvanized Steel Signal Poles

Notes Manufacturer Catalog Number Approval Date Photos
Millerbernd Manufacturing Company 1994 AASHTO: 780B661
2013 AASHTO: 780B1885 Rev C
Identification Label: Single Arm  : Double Arm
8/10/10
11/10/14
Union Metal 1994 AASHTO: 50915-B1 Rev 9
2013 AASHTO: 50915-B19 Rev 5
10/27/04
8/31/15
Valmont 1994 AASHTO: DB00175 Rev E
2013 AASHTO: DB01086 Rev F
1/26/12
7/28/14
Comment:
See "Anchor Bolts" for part number information
Shall meet 2013 AASHTO Criteria unless otherwise specified in the bid plans, documents and details

Pedestrian Pushbutton Pole and Foundation

Notes Manufacturer Catalog Number Approval Date Photos
Frey Manufacturing Corp. Pedestrian Pushbutton Pole with Pole Cap:
CP6ACT4840TCSS / Dwg No. 8.1.0 Rev. 1
Pedestrian Pushbutton Pole Cap:
TCSS Top Cap with Set Screws for 4" Pipe / Dwg No. 8.4.1 Rev. 1
11/30/17 Pedestrian Pole
Breakaway Base
Breakaway Base Angle
Pedestal Door
Pole Cap
Bolts
Comment:
Frey Mfg pole requires approved Two-Part Epoxy.

Power Backup Systems

CNG Generators

Notes Manufacturer Catalog Number Approval Date Photos
Alpha Technologies AlphaGen CE-3x2-50-48 NG with Cold Weather Starting Kit
With PCC-3x Polymer Concrete Pre-Cast Pad
Includes Alpha supplied battery

DO NOT PROVIDE WITH TRANSFORMER AND FUSE
6/17/03
Comment:
48V DC output voltage
96 amp max DC output current
10.5 Hp single OHV engine
13.5 VDC Ignition Charger Voltage
6 amp max Ignition Charger Current
2800 to 3600 RPM variable speed
80 CuFt/hr Natural Gas, 1000 BTU/CuFt
0.5 – 2 PSI Gas Inlet Pressure

UPS Systems

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance
Use Only
Alpha Novus FXM-1100 – Part No. 017-230-23 (48-volt system)
with Automatic Transfer Switch and AC receptacle P/N 02016827
11/10/11
For Maintenance
Use Only
Blue Earth Energy Power Solutions 170 UPStealth
1000 Watt Capacity: Inverter-170-01
1500 Watt Capacity: Inverter-170-01-HD

Power Interface Module: NKKS732
2/10/15 Inverter Front View
Inverter Back View
Power Interface Module
Cables
Clary Stand Alone Battery Backup /UPS Unit
SP 1250-LX-R – Uninterruptible Traffic System with Integrated PIM and Programmable Display
SPO-09A2 – SNMP Adapter with cables manual and software
SPD-302C – Bypass Switch with GFCI and Generator Plug
SP-19N1 – Battery Cable
72-volt system
9/26/13 UPS Front View
UPS Contacts
Bypass Switch
Bypass Switch Label
Clary Combined Battery and CNG Backup Unit
SP 1250-LX-R-48 – Uninterruptible Traffic System with Integrated PIM and Programmable Display
SPO-09A2 – SNMP Adapter with cables manual and software
SPD-302C – Bypass Switch
100-16136 – 48 VDC Battery Generator Interface Box
104-16163-60 – 48 Volt Dual String Battery Cable
48-volt system
4/12/10 UPS Front View
UPS Contacts
Bypass Switch
Generator Interface Box
Comment:
Ethernet port capabilities
See Battery requirements below.
Use ONLY the specified batteries as listed for each UPS system as listed in the table below.

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Power Transfer Switches

Notes Manufacturer Catalog Number Approval Date Photos
Formerly Gen-Tran Corporation Generac 6377 10/5/05 Front View
Bottom View
Reliance Controls C30A2L 7/19/16
Comment:
Double Pole 30 Amp manual transfer switch
NEMA 3R Aluminum housing with No. 2 keyed lock
Pilot light indicator
4-prong L14-30R Generator Outlet

Batteries

Batteries for UPS

Notes Manufacturer Catalog Number Approval Date Photos Comments
For Maintenance
Use Only
Alpha Model 165 GXL – Part No. 1810015 (set of four batteries)
48-volt system (Stand alone or combined BBS/CNG)
1/18/12 Gel Top Terminal Battery (4 Year Full Replacement Warranty)
For Maintenance
Use Only
Blue Earth Energy Power Solutions Living-Hinge Battery Panel
300 Watt: Battery-300-01
500 Watt: Battery-500-01
500 Watt Shelf Mount: Battery-500-N-01

Wall Charging Adapter
2/10/15 Battery Front
Indicator Light
Fits between rack and outside cabinet wall, except for shelf mount unit
Clary OP72C-41 – Batteries (set of six)
72-volt system (Stand alone BBS)
OP96C-41 – Batteries (set of eight)
48-volt system (Combined BBS/CNG)
10/7/11 Battery
Battery String
Absorbed Glass Mat (AGM)
Valve Regulated , Lead Acid (VRLA)

Batteries for CNG Generator

Notes Manufacturer Catalog Number Approval Date Photos Comments
Alpha Model 195 GXL 1/18/12 Gel Top AGM Terminal Battery (4 Year Full Replacement Warranty)

Rebar Support Products

Support Spacers

Notes Manufacturer Catalog Number Approval Date Photos
Pieresearch Drill Shaft Wheels:
6QLHD
Technical Drawing
Support Boots:
#5 - #14 Bars: 3PB
Technical Drawing
7/12/19
Rebar Support Products Drill Shaft Wheels:
DP300
Support Boots:
#3 - #8 Bars: BB38
#8 - #11 Bars: BB811
7/12/19

Secondary Service Pedestals

Aluminum Electrical Service Enclosure

Notes Manufacturer Catalog Number Approval Date Photos
Myers Custom Products, Inc. MEA-IIVLM-TSR 4/19/19
Purchased by
Myers Custom Products, Inc
Pacific Utility Products USP2R-100-112C-OPK-TS-AL 2/17/12 Front View
Interior View
Meter Socket
Lock
Breaker
Bottom View
Comment:
0.125” Aluminum, 30 amp breaker
Corbin #2 lock on door
No photocell or lighting relays
Ringless Meter Socket with Horn By-Pass

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Battery Backup / Electrical Service Enclosure

Notes Manufacturer Catalog Number Approval Date Photos
USED ONLY FOR MAINTENANCE REPLACEMENTS Myers Custom Products, Inc. Cabinet – MET2-PB-M030-AC-EMI
Drawing No. F518506
8/23/05
USED ONLY FOR MAINTENANCE REPLACEMENTS Pacific Utility Products Cabinet – USP29-57-BBS 7/9/10
USED ONLY FOR MAINTENANCE REPLACEMENTS Traffic Signal Controls Cabinet – 2116UPME1401 9/3/09
Comment:
0.125” aluminum
Manual transfer switch behind police door
For use with external portable generator
See below for External Generator Receptacle data
20Amp breaker for CCTV Camera Disconnect

Battery Backup to CNG Electrical Service Enclosure

Notes Manufacturer Catalog Number Approval Date Photos
USED ONLY FOR MAINTENANCE REPLACEMENTS Myers Custom Products, Inc. Cabinet – MET2-PB-M030-DC-EMI
Drawing No. F518507
8/23/05
USED ONLY FOR MAINTENANCE REPLACEMENTS Pacific Utility Products Cabinet – USP29-57-BBS 7/9/10
USED ONLY FOR MAINTENANCE REPLACEMENTS Traffic Signal Controls Cabinet-2116UPME1401 9/3/09
Comment:
0.125” aluminum
For use with permanent CNG generator and gas service line
20Amp breaker for CCTV Camera Disconnect

CNG External Generator Receptacle

Notes Manufacturer Catalog Number Approval Date Photos
Hubbell HBL2710SW including HBL2715 flanged receptacle 4/2/12
Reliance Controls PK30 Power Inlet Kit, including L1430F flanged receptacle 4/2/12
Comment:
Twist Lock Recessed Male, 30 Amp 120/240 Volt, 4 prong including ground with outdoor hinged cover

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Signal Heads

Signal Head Louvers

Notes Manufacturer Catalog Number Approval Date Photos
Pelco GL-1010-X-UC-P02 11/14/14
Comment:
Geometrically programmed louver with black visor
X = 7, 8, 9, 11, 12, 15, 23.5 or 42 degrees depending on the cut-off angle desired.
The maximum number of louvers comes with the 7 degree cut-off
UC = Universal Clips
P02 = Black

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Vehicular Signal Heads

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Control Products, Inc. Yellow Body:
TP31VJC2P0H0 for 3 Section
TP41VJC2P0H0 for 4 Section
TP11VJC2P0H0 for 1 Section

Black Body:
TP31VJF2P0H0 for 3 Section
TP41VJF2P0H0 for 4 Section
TP11VJF2P0H0 for 1 Section
5/9/03 Front View
Back View
Open Front View
Wiring Terminals
Latch
McCain Traffic Supply Yellow Body:
M22167-P for 1 Section
M22436-P for 3 Section
M31084-P for 4 Section

Black Body:
M22168-P for 1 Section
M22435-P for 3 Section
M30883-P for 4 Section


M19271 Black Poly Visors
5/14/13 Open Front View
Wiring Terminal
Side View
Latch
Label
Mobotrex / Eagle Signal Yellow Body
SA103A1111YBB for 3 Section
SA104A1111YBB for 4 Section
SA101A1111YBB for 1 Section
SA1031T3T1111YBB - HAWK

Black Body:
SA103A1111BBB for 3 Section
SA104A1111BBB for 4 Section
SA101A1111BBB for 1 Section
SA1031T3T1111BBB - HAWK
5/5/03
Peek Traffic Yellow Body
PSS81S001FO for 1 Section
PSS83S003FO for 3 Section
PSS84S004FO for 4 Section


Black Body
PSS81E001FO for 1 Section
PSS83E003FO for 3 Section
PSS84E004FO for 4 Section
5/5/03
Comment:
Yellow Polycarbonate Body (Standard)
Black Polycarbonate Body (Special)
Black Polycarbonate Doors and Visors
Visors to be Tunnel Type
LED retrofit
12” Sections

Countdown Pedestrian Signal Heads

Notes Manufacturer Catalog Number Approval Date Photos
McCain Traffic Supply M31466 – Yellow housing
M31655 – Black housing
12/30/04
Siemens SG7-S-Z10COYB010 – Yellow housing
SG7-S-Z10COBB010 – Black housing
9/20/11 Top View
Inside View
Latch
Comment:
Yellow polycarbonate body (Standard)
Black polycarbonate body (Special)
Black Aluminum Door / No Z-Crate Visor
Port hole mount

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Wire Connectors

Wire Connectors for Loop Lead-In

Notes Manufacturer Catalog Number Approval Date Photos
King Innovation/Dryconn For 2 #14 AWG
Aqua/Orange Waterproof Connector
62110 - Card of 6
62125 - Bag of 25
62135 - Bag of 100
62150 - Bag of 500

For 2, 3, 4 or 5 #14 AWG
Auqua/Red Waterproof Connector
62210 - Card of 5
62225 - Bag of 20
62235 - Bag of 100
62250 - Box of 500

For 4, 5 or 6 #14 AWG
Aqua/Blue Waterproof Connector
62310 – Card of 3
62325 – Bag of 15
62335 – Bag of 50
62340 – Bag of 250
10/14/03 Aqua/Blue
Comment:
Wire Range: Min. #14 AWG / Max. #6 AWG Copper
Silicone Sealant Filled
Watertight/raintight

Wire Connectors for Multi-Conductor Signal Cable

Notes Manufacturer Catalog Number Approval Date Photos
King Innovation/Dryconn For 2, 3, 4 or 5 #14 AWG
King 4 Yellow: 10444 - Bag of 10
For 2, 3, 4 or 5 #14 AWG
King 5 Red: 10555 - Bag of 10
For 2, 3, 4 or 5 #14 AWG
King 6 Blue: 10670 - Box of 100
For 4, 5 or 6 #14
King 9 Dark Blue: 10975 - Box of 75
10/14/03 King 6 Blue
Comment:
Wire Range: Min. #22 AWG / Max. #8 AWG Copper
Silicone Sealant Filled
Direct Burial

Wire Connectors for Radar Detector Cable

Notes Manufacturer Catalog Number Approval Date Photos
3M Scotchlok Butt Connector:
UAL(BX) 100/box, 10 boxes/case
6/14/17 Top View
Side View
Comment:
Wire Range: Min. #24 AWG / #19 AWG Max. Copper

Epoxy

Two-Part Epoxy for Concrete

Notes Manufacturer Catalog Number Approval Date Photos
HILTI HIT-RE 500-V3 12/4/2017
ITW Commercial Construction Red Head Concrete Anchoring Solutions - A7+ 12/4/2017
Powers PE1000+ 12/4/2017
Simpson Strong-Tie SET-XP 12/4/2017
Comment:
Shall be classified as a concrete anchor for use in cracked or uncracked concrete.
Shall be dispensed with a dual-chamber cartridge with a static mixing nozzel which attaches to the cartridge.

Rivet Nuts

Rivet Nuts and Installation Tools for Pushbutton Poles

Notes Manufacturer Catalog Number Approval Date Photos
During pedestrian pushbutton pole ordering request appropriate number of rivet nuts and installation tool. Frey Manufacturing Corp. Rivet Nut/Insert Nut: Part Number IN1/4
Installation Tool: Part Number WT1/4
TBD Revit Nut with Tool and Bolt
Fastenal Rivet Nut 1/4-20 .165-.260 12/4/2017
AVK Industrial Products Threaded Insert ARS4T-420-500 12/4/2017
Expendable Tool H.W. Eckhardt Corporation AAT916-420 TBD
Comment:
Size 1/4-20 and Yellow Zinc Plated.
Drill 25/64" holes.
Other tools for rivet nut insertion available.
1/4"-20 x 1-1/2" phillips drive flat head stainless steel machine screw recommended for pushbutton attachment.

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png