Safetran
|
Model 332Strech-OPKS
|
|
Pad Mount DMS Sign Cabinet
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Safetran
|
Model 334-OPKS
|
5/5/03
|
|
Detection Systems
Microloop Probes
Non-Invasive Vehicle Detectors Probes
|
|
Comment:
|
|
|
|
|
Red LED indicator Audible locator Auto volume adjustment for ambient noise levels EN4 – EZ Communicator Navigator 4 Wire system 3 – 9” x 15” Face Plate T – 9”x15” R10-3e High Intensity Sheeting Pushbutton Sign N – No Braille on Face Plate 1 – Custom Message (Recorded at Factory w/ electronic copy sent to City) PY – Yellow back and front housing
|
|
|
Comment:
|
|
|
|
|
Yellow body with sound on actuation NO LED Flash X = B for Black or Y for Yellow
|
Pre-empt Detectors
|
|
Comment:
|
|
|
|
|
Two Direction Single Channel
|
Advance Radar Detectors
|
|
Comment:
|
|
|
|
|
Include the SDLC Cabinet Interface Module Two SDLC Cabinet Interface Modules are required for more than 4 sensors
|
Presence Radar Detectors
|
|
Comment:
|
|
|
|
|
Include the SDLC Interface Module Two SDLC Cabinet Interface Modules are required for more than 4 sensors
|
Vehicle Detectors
|
|
Comment:
|
|
|
|
|
It shall have TS2 status output available
|
Video Detection Systems
Grounding Equipment
RJ-45 Data Protector
|
|
Comment:
|
|
|
|
|
Use with IP High Definition CCTV Cameras
|
Ground Rod
|
|
Comment:
|
|
|
|
|
½” x 10’-0” long at poles and controller cabinet ½” x 8’-0” long at service boxes Copper clad steel core UL listed
|
Ground Rod Clamp
|
|
Comment:
|
|
|
|
|
Hex head set screw Copper alloy Long bearing surface UL listed
|
Junction and Service Boxes
Type 1 Junction Box
|
|
Comment:
|
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 1 Piece cover to be ¾” min thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
Type 2 Junction Box
|
|
Comment:
|
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 1 Piece cover to be 2” thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
Type 1 Service Box
|
|
Comment:
|
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 1 Piece cover to be 3” thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
Type 2 Service Box
|
|
Comment:
|
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 2 Piece cover to be 3” thick underlapping Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
LED Units
Red Ball LED
|
|
Comment:
|
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Yellow Ball LED
|
|
Comment:
|
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Green Ball LED
|
|
Comment:
|
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Countdown Pedestrian LED
|
|
Comment:
|
|
|
|
|
16” X 18” Orange Hand/White Man Incandescent look Filled/Overlay Style 9” Numerals
|
Red LED Arrow
|
|
Comment:
|
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Yellow LED Arrow
|
|
Comment:
|
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Green LED Arrow
|
|
Comment:
|
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Bi-Modal Green/Yellow LED Arrow
|
|
Comment:
|
|
|
|
|
Clear Lens, pixilated arrow
|
Loop Sealants
|
|
Comment:
|
|
|
|
|
Crafco sealant may only be used on loops sawed into the final surface of the pavement.
|
Miscellaneous Controller Equipment
170 Controller
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
| Quixote Traffic Corp purchased US Traffic
|
IDC / US Traffic Corp / Quixote Traffic Corp
|
170E
|
5/503
|
|
|
|
Safetran
|
170E
|
5/5/03
|
|
|
|
Comment:
|
|
|
|
|
USED ONLY FOR MAINTENANCE
|
2070 Controller
|
|
Comment:
|
|
|
|
|
USED ONLY FOR MAINTENANCE
|
Rack Mount Controller
|
|
Comment:
|
|
|
|
|
with Data Key Modules: · 1 – 3B front panel · 1 – 2A field panel · 1 – 4A power supply · 1 - CPU module · Removable power cord Meets CalTrans Transportation Electrical Equipment Specifications August 2002 as revised October 27, 2003 ASC/2070 Firmware shall be provided with the controller
|
Bus Interface Unit (BIU)
|
|
Comment:
|
|
|
|
|
½ width design - Only used with Hybrid Cabinet
|
AC Isolator
Conflict Monitor
|
|
Comment:
|
|
|
|
|
Not used with Hybrid Cabinet. See “Malfunction Management Unit” below
|
DC Isolator
|
|
Comment:
|
|
|
|
|
Model 242 Not used with Hybrid Cabinet. See “Detector Test Switch Module” below.
|
K1 Control Relay
|
|
Comment:
|
|
|
|
|
Only used with Hybrid Cabinet
|
Flash Transfer Relay
Flasher Unit
Malfunction Management Unit (MMU)
|
|
Comment:
|
|
|
|
|
Only used in Hybrid traffic signal cabinet in place of the conflict monitor
|
Power Distribution Surge Protection Unit
|
|
Comment:
|
|
|
|
|
Room for 8 transformer spaced outlets (minimum) 15 amp breaker Rack mounted NEMA 5-15
|
Power Supply
|
|
Comment:
|
|
|
|
|
High efficiency power saving w/ solid state transfer relay
|
Power Distribution Assembly (PDA)
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
McCain
|
PDA#2 M63186
|
7/14/10
|
|
|
|
SafeTran
|
|
|
|
Pre-empt Phase Selectors / Discriminator Module
|
|
Comment:
|
|
|
|
|
With Ethernet Ports
|
Switchpack / Load Switch
Surge Protector (Traffic Signal Cabinet)
Utility Power Surge Protector (Secondary Service Enclosure)
|
|
Comment:
|
|
|
|
|
Note: NEMA-4 weather tight housing Output contacts Replaceable cartridge overcurrent fuse protection Replaceable modules Event timer
|
Mounting Brackets
Video Detection Camera Mounting Bracket for Luminaire Arm
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
Comments
|
|
|
Pelco Products, Inc.
|
SH-0502-10 w/ SE-4049 SH-0509-10 w/SE4049 Econolite
|
10/4/02
|
|
Narrow hub plate substituted for SE-4071 universal hub plate
|
|
|
Pelco Products, Inc.
|
EM-1109 EM-2200
|
10/31/05
|
|
The EM-1109 is for mounting on top of the luminaire arm The Em-2200 is a J-hook designed to mount below the luminaire arm
|
Video Detection Camera Mounting Bracket Side of Pole Mount
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Pelco
|
EM-2000
|
10/31/05
|
|
Video Detection Camera Mounting Bracket for Mast Arm
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Pelco Products, Inc.
|
AstroBrac AS-0175-5-62
|
10/4/02
|
|
Combined Video Detection Camera /Signal Head Mounting Bracket for Mast Arm
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Pelco Products, Inc.
|
AstroBrac AB-0608-74-L (4 Section)
|
|
|
Radar Detector Mounting Bracket
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Pelco Products, Inc.
|
AstroBrac SP-5772-PNC
|
7/24/12
|
|
|
|
Comment:
|
|
|
|
|
12 = Tube Length 84 = Cable Length P = Paint NC = No Coating
|
RWIS Sensor Mounting Bracket for Mast Arm
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Pelco Products, Inc.
|
AstroBrac AB-0164-12-84
|
1/28/11
|
|
|
|
Comment:
|
|
|
|
|
With 4-hole mounting plate 12 = Tube Length 84 = Cable Length (RWIS Manufacturer provides the PVC enclosure that mounts to the Tee pipe nipple)
|
Combined Radar Detector / RWIS Sensor Mounting Bracket for Mast Arm
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Pelco Products, Inc.
|
AstroBrac AB-0164-23-84 (SPECIAL) and SH0515
|
1/28/11
|
|
|
|
Comment:
|
|
|
|
|
With 4-hole mounting plate 23 = Tube Length 84 = Cable Length “SPECIAL” indicates the tube is threaded on each end The SH0515 mounting bracket for the radar unit needs to be drilled for a 5 hole configuration. An additional SH0515 mounting bracket is attached to the other threaded end for the RWIS unit. Only one Tee pipe nipple is required (RWIS Manufacturer provides the PVC enclosure that mounts to the Tee pipe nipple)
|
Mast Arm Signal Head Bracket
|
|
Comment:
|
|
|
|
|
Cable mount bracket assembly L=cable length (62”, 84”, or 96”) PNC=Process No Color
|
Side Mount Signal Head and Pedestrian Signal Head Bracket
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Auto/Eagle
|
UKS-1452X
|
5/5/03
|
|
|
|
Component Products, Inc.
|
TSP880-X
|
5/5/03
|
|
|
|
Gades
|
UKS1452X / PDM-405
|
5/5/03
|
|
|
|
Comment:
|
|
|
|
|
Yellow polycarbonate X=Y for Yellow X= B for Black
|
Mini Pre-empt Detector Bracket
|
|
Comment:
|
|
|
|
|
Cable mount L = Cable Length (45”, 62” or 84”) PNC = Process No Color
|
Poles
Aluminum Pedestal Poles
|
|
Comment:
|
|
|
|
|
See "Anchor Bolts" for part number information Pole tube is schedule 40 Include base collar with every pole Set screws required in base collar Include 2 7/8” OD x 7/8” ID galvanized flat washers Include anchor bolts
|
Galvanized Steel Signal Poles
|
|
Comment:
|
|
|
|
|
See "Anchor Bolts" for part number information Shall meet 1994 AASHTO or 2013 AASHTO Criteria as specified in the bid plans, documents and details
|
|
|
Comment:
|
|
|
|
|
Hot dip galvanized finished smooth.
|
|
|
Comment:
|
|
|
|
|
ABS Plastic. Square base with 3.5” diameter hole. Two-piece cover – natural aluminum
|
Power Backup Systems
CNG Generators
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Alpha Technologies
|
AlphaGen CE-3x2-50-48 NG with Cold Weather Starting Kit With PCC-3x Polymer Concrete Pre-Cast Pad Includes Alpha supplied battery
DO NOT PROVIDE WITH TRANSFORMER AND FUSE
|
6/17/03
|
|
|
|
Comment:
|
|
|
|
|
48V DC output voltage 96 amp max DC output current 10.5 Hp single OHV engine 13.5 VDC Ignition Charger Voltage 6 amp max Ignition Charger Current 2800 to 3600 RPM variable speed 80 CuFt/hr Natural Gas, 1000 BTU/CuFt 0.5 – 2 PSI Gas Inlet Pressure
|
UPS Systems
|
|
Comment:
|
|
|
|
|
Ethernet port capabilities See Battery requirements below. Use ONLY the specified batteries as listed for each UPS system as listed in the table below.
|
Power Transfer Switches
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Gen/Tran Corporation
|
TS300230PL
|
10/5/05
|
|
|
|
Comment:
|
|
|
|
|
Double Pole 30 Amp manual transfer switch Aluminum housing and #2 key Pilot light indicator
|
Batteries
Batteries for UPS
Batteries for CNG Generator
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
Comments
|
|
|
Alpha
|
Model 195 GXL
|
1/18/12
|
|
Gel Top AGM Terminal Battery (4 Year Full Replacement Warranty)
|
Secondary Service Pedestals
Aluminum Electrical Service Enclosure
|
|
Comment:
|
|
|
|
|
0.125” Aluminum, 30 amp breaker Corbin #2 lock on door No photocell or lighting relays Ringless Meter Socket with Horn By-Pass
|
Battery Backup / Electrical Service Enclosure
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
| USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Myers Custom Products, Inc.
|
Cabinet – MET2-PB-M030-AC-EMI Drawing No. F518506
|
8/23/05
|
|
| USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Pacific Utility Products
|
Cabinet – USP29-57-BBS
|
7/9/10
|
|
| USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Traffic Signal Controls
|
Cabinet – 2116UPME1401
|
9/3/09
|
|
|
|
Comment:
|
|
|
|
|
0.125” aluminum Manual transfer switch behind police door For use with external portable generator See below for External Generator Receptacle data 20Amp breaker for CCTV Camera Disconnect
|
Battery Backup to CNG Electrical Service Enclosure
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
| USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Myers Custom Products, Inc.
|
Cabinet – MET2-PB-M030-DC-EMI Drawing No. F518507
|
8/23/05
|
|
| USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Pacific Utility Products
|
Cabinet – USP29-57-BBS
|
7/9/10
|
|
| USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Traffic Signal Controls
|
Cabinet-2116UPME1401
|
9/3/09
|
|
|
|
Comment:
|
|
|
|
|
0.125” aluminum For use with permanent CNG generator and gas service line 20Amp breaker for CCTV Camera Disconnect
|
CNG External Generator Receptacle
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
Hubbell
|
HBL2710SW including HBL2715 flanged receptacle
|
4/2/12
|
|
|
|
Reliance Controls
|
PK30 Power Inlet Kit, including L1430F flanged receptacle
|
4/2/12
|
|
|
|
Comment:
|
|
|
|
|
Twist Lock Recessed Male, 30 Amp 120/240 Volt, 4 prong including ground with outdoor hinged cover
|
Signal Heads
Signal Head Louvers
|
|
Comment:
|
|
|
|
|
Geometrically programmed louver with black visor X = 7, 8, 9, 11, 12, 15, 23.5 or 42 degrees depending on the cut-off angle desired. The maximum number of louvers comes with the 7 degree cut-off UC = Universal Clips P02 = Black
|
Vehicular Signal Heads
|
|
Comment:
|
|
|
|
|
Yellow Polycarbonate Body (Standard) Black Polycarbonate Body (Special) Black Polycarbonate Doors and Visors Visors to be Tunnel Type LED retrofit 12” Sections
|
Countdown Pedestrian Signal Heads
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
McCain Traffic Supply
|
M31466 – Yellow housing M31655 – Black housing
|
12/30/04
|
|
|
|
Siemens
|
SG7-S-Z10COYBB010 – Yellow housing SG7-S-Z10COBBB010 – Black housing
|
9/20/11
|
|
|
|
Comment:
|
|
|
|
|
Yellow polycarbonate body (Standard) Black polycarbonate body (Special) Black Aluminum Door / No Z-Crate Visor Port hole mount
|
Wire Connectors
Wire Connectors for Loop Lead-In
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
King Innovation/Dryconn
|
KB – Aqua/Blue Waterproof Connector 62310 – Card of 3 62325 – Bag of 15 62335 – Bag of 50 62340 – 250
|
10/14/03
|
|
|
|
Comment:
|
|
|
|
|
Wire Range: Min. #14 / Max. #6 Copper Silicone Sealant Filled Watertight/raintight
|
Wire Connectors for Multi-Conductor Signal Cable
| Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
|
King Innovation/Dryconn
|
King 6 Blue Waterproof Connector 10600 – Card of 2 10666 – Bag of 10
|
10/14/03
|
|
|
|
Comment:
|
|
|
|
|
Wire Range: Min. #22 / Max. #8 Copper Silicone Sealant Filled Direct Burial
|
|