From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation
Jump to search
Return to Complete Preapproved Materials Page
|
Note: This document is provided as a benefit to contractors and suppliers who are bidding projects for the City of Overland Park. Only products identified on this list will be approved for installation on City construction projects. This list shall not be used as a substitute for catalog cuts or material approval. All material approvals shall be submitted on the approved City of Overland Park Contract Project Submittal form. The form is available at City Hall by contacting Bruce Wacker at (913) 895-6027. Failure to comply will be cause for rejection of materials until proper submittals are received. This list is updated periodically. The contractor or supplier shall contact the City of Overland Park to make sure that they have the most current list prior to bidding a project. Failure to do so shall not constitute a legitimate claim for change orders. Before accessing any links, the City recommends that the user delete browsing history to insure the latest catalog cut information is displayed correctly.
|
Contractor Submittal Form
Anchor Bolts
Signal Mast Arm Poles
Pedestal Signal Poles
Backplates (Vehicular)
|
Comment:
|
|
|
|
0.125” thick 12” Signal Head Sections
|
Cable
Video Detection Cable
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
Econolite Exclusive
|
Falcon Fine Wire
|
970316TS-00-1MP
|
1/30/12
|
Cable Jacket
|
Econolite Exclusive
|
Isotec
|
X339313-00 (for Econolite Solo Terra Systems)
|
4/25/08
|
Cable
|
CCTV Camera Data Cable
|
Comment:
|
|
|
|
Outdoor Rated Category 6, Shielded Twisted, 4 pair, 23 AWG, 600 MHz with drain wire and waterblock tape. Requires an RJ-45 Plug in Data Protector (see Grounding Equipment)
|
CCTV Camera Communication Cable
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
USED ONLY FOR MAINTENANCE ON PELCO CCTV DOME CAMERA SYSTEMS
|
Belden
|
8281F 75 Ohm (for CCTV Cameras) with 75 Ohm Connectors
|
2/1/01
|
|
CCTV Camera Pan-Tilt-Zoom Cable
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
USED ONLY FOR MAINTENANCE ON PELCO CCTV DOME CAMERA SYSTEMS
|
Belden
|
9843
|
6/17/03
|
|
CCTV Camera Power Cable
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
USED ONLY FOR MAINTENANCE ON PELCO CCTV DOME CAMERA SYSTEMS
|
Advanced Digital Cable / Clifford of Vermont
|
8103/3C14B7119-1
|
5/5/03
|
|
Falcon Fine Wire
|
980314X19-1-00
|
4/24/08
|
|
Southwire
|
#14 AWG stranded copper
|
7/15/08
|
|
|
Comment:
|
|
|
|
1-3c#14 IMSA 19-1
|
CNG Monitoring Cable/Illuminated Street Name Sign Cable
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Advanced Digital Cable / Clifford of Vermont
|
8103/3C14B7119-1
|
5/5/03
|
|
|
Falcon Fine Wire
|
980314X19-1-00
|
4/24/08
|
|
|
Comment:
|
|
|
|
1-3c#14 IMSA 19-1
|
CNG Power Cable 1-3c #2AWG
|
Comment:
|
|
|
|
600 Volt Copper soft drawn stranded copper #2 AWG
|
Induction Loop Cable 1c#14
|
Comment:
|
|
|
|
IMSA Type 51-5 Tube Loop Detector Cable PVC/nylon Insulated cable PVC Tube 600 Volt
|
Multi-conductor 7c#14 and 2c#14
|
Comment:
|
|
|
|
IMSA 19-1 600 Volt Stranded Copper #14 AWG
|
Micro loop Home Run
Non-Invasive Micro Loop Home Run Cable
Emergency Vehicle Pre-emption (EVP) Detector Cable
Radar Detector Home Run Cable
|
Comment:
|
|
|
|
2 pair 22 AWG communication wires (blue, blue/white, orange, orange/white) 1 pair 20 AWG power wires (red and black) 1 drain cable, unless otherwise shown
|
Radar Detector Harness Cable
|
Comment:
|
|
|
|
100’ harness to be spliced to home run cable at pole base using 3M ScotchLok insulation displacement connectors
|
Shielded Detector Lead-in 2c#14
|
Comment:
|
|
|
|
IMSA Type 50-2 Loop Lead-in Cable Polyethylene Insulated 600 Volt Stranded Copper #14 AWG
|
#10 AWG System Ground Wire and Tracer Wire
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Cerowire Wire & Cable Co., Inc.
|
Red – 112-3803 Green – 112-3805 UL file # E15119
|
5/5/03
|
|
|
Encore Wire LTD
|
UL file # E123774
|
8/1/03
|
|
Purchased by Southwire Co.
|
Essex Group, Inc.
|
Product Number 070101 UL File # E14656
|
2/1/01
|
|
|
Senator / Southwire
|
22-97-57 UL file # E23919
|
5/5/03
|
|
|
Service Wire
|
UL file # E105667
|
5/7/02
|
|
|
United Copper Industries
|
Red – 325372 (500’ reel) Green – 325379 (500’ reel)
Red – 325574 (2,500’ reel) Green – 325580 (2,500’ reel)
UL file # E194031-A
|
5/26/09
|
|
|
Comment:
|
|
|
|
Stranded copper #10 AWG THHN 600 volt Tracer wire shall have Red insulation Ground wire shall have Green insulation
|
#6 AWG Equipment Ground Wire
|
Comment:
|
|
|
|
Bare copper soft drawn solid copper #6 AWG
|
Electrical Service Cable
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
Member of The Marmon Group of Companies
|
Aetna Insulated Wire Co.
|
UL file # E63541
|
2/21/05
|
|
|
Alan Wire
|
Product Number 04USE11 – 500’ UL file #E319493
|
1/30/12
|
|
Member of The Marmon Group of Companies
|
Cerro Wire & Cable Co, Inc.
|
UL file # E11098
|
5/5/03
|
|
|
Draka Cableteq
|
Product Number 388932
|
7/8/09
|
|
|
Encore Wire LTD
|
UL file # E174428
|
8/1/03
|
|
|
Kris Tech Wire Co, Inc.
|
0407-RHW/USE-BK UL file # E207249
|
11/24/03
|
|
|
Senator / Southwire Co
|
11-32-72 UL file # E32071
|
5/5/03
|
|
|
Service Wire Co
|
UL file # E105667
|
5/7/02
|
|
|
Comment:
|
|
|
|
No. 4 AWG USE Copper Black insulation Single cable, not three cables twisted on the reel
|
Conduit and Fittings
HDPE Signal Conduit
|
Comment:
|
|
|
|
SDR 13.5 for all diameters Red with 3 longitudinal white stripes Smooth outside wall UV Stabilized
|
HDPE Service Conduit
|
Comment:
|
|
|
|
SDR 13.5 Black with red stripes Smooth outside wall UV Stabilized
|
HDPE Couplings
PVC Conduit
PVC Fittings
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Allied Tube & Conduit
|
Standard Couplings: 1” – 59603 1 ½” – 59605 2” – 59606 3" – 59608 4" – 59610
90º Elbows 36” Radius for Power: (Plain End) / (Bell End) 2” – 59730 / NA
90º Elbows: (Plain End / Belled End) 1” – 59590 / 802754 1 ½” – 59592 / 802756 2” – 59593 / 807757 3” – 59595 / 802759 4" – 59597 / 802762
45º Elbows:(Plain End / Belled End) 1” – 59577 / 802768 1 ½” – 59579 / 802770 2” – 59580 / 802771 3” – 59582 / 802773 4” – 59584 / 802775
30º Elbows: (Plain End / Belled End) 1” – 59563 / 802780 1 ½” – 59565 / 802782 2” – 59566 / 802783 3" – 59568 / 802785 4” – 59570 / 802787
|
9/3/14
|
|
|
Cantex
|
Standard Couplings: 1” – 6141625 1 ½” – 6141627 2” – 6141628 3” – 6141630 4” - 6141632
90º Elbows 36” Radius for Power: (Plain End) / (Belled End) 2” – 5133848 / 5233848
90º Elbows: (Plain End / Belled End) 1” – 5133825 / 5233825 1 ½” – 5133827 / 5233827 2” – 5133828 / 5233828 3” – 5133830 / 5233830 4” – 5133832 / 5233832
45º Elbows: (Plain End / Belled End) 1” – 5133765 / 5233765 1 ½” – 5133767 / 5233767 2” – 5133768 / 5233768 3” – 5133770 / 5233770 4” – 5133772 / 5233772
30º Elbows: (Plain End / Belled End) 1” – 5133745 / 5233745 1 ½” – 5133747 / 5233747 2” – 5133748 / 5233748 3” – 5133750 / 5233750 4” – 5133775 / 5233776
|
5/5/03
|
|
|
Heritage Plastics
|
Standard Couplings: 1” – 610002 1 ½” – 610004 2” – 610005 3” – 610007 4” – 610009
90º Elbows 36” Radius for Power: (Plain End) / Belled End) 2” – 611353 / 611140
90º Elbows: (Plain End / Belled End) 1” – 611002 / 611058 1 ½” – 611004 /611060 2” – 611005 / 611061 3” – 611007 / 611063 4” – 611009 / 611065
45º Elbows: (Plain End / Belled End) 1” – 611016 / 611071 1 ½” – 611018 / 611073 2” – 611019 / 611074 3” – 611021 / 611076 4” – 611023 / 611078
30º Elbows: (Plain End / Belled End) 1” – 611030 / 611085 1 ½” – 611032 / 611087 2” – 611033 / 611088 3” – 611035 / 611090 4” – 611037 / 611092
|
7/24/12
|
|
|
IPEX / Scepter
|
Standard Couplings: 1” – EC20 / 077003 1 ½” – EC30 / 077005 2” – EC35 / 077006 3” – EC45 / 077008 4” – EC55 / 077010
90º Elbows 36” Radius for Power: (Plain End / Belled End) 2” – 068765 / 068054
90º Elbows: (Plain End / Belled End) 1” – EE2090 / EE2090B 1 ½” – EE3090 / EE3090B 2” – EE3590 / EE3590B 3” – EE4590 / EE4590B 4” – EE5590 / EE5590B
45º Elbows: (Plain End / Belled End) 1” – EE2045 / EE2045B 1 ½” – EE3045 / EE3045B 2” – EE3545 / EE3545B 3” – EE4545 / EE4545B 4” – EE5545 / EE5545B
30º Elbows: (Plain End / Belled End) 1” – EE2030 / NA 1 ½” – EE3030 / NA 2” – EE3530 / NA 3” – EE4530 / NA 4” – EE5530 / NA
22.5º Elbows: (Plain End / Belled End) 1” – NA / NA 1 ½” – EE1522 / NA 2” – EE2022 / NA 3” – EE3022 / NA 4” – EE4022 / NA
|
12/22/05
|
|
|
Plastic Trends / Royal Pipe Systems
|
Standard Couplings: 1” – E010100 1 ½” – E010150 2” – E010200 3” – E010300 4” – E010400
90º Elbows 36” Radius for Power: (Plain End / Belled End) 2” – E07520036 / E07920036 90º Elbows: (Plain End / Belled End) 1” – E018100 / E021100 1 ½” – E081850 / E 021150 2” – E018200 / E021200 3” – E018300 / E021300 4” – E018400 / E021400
45º Elbows: (Plain End / Belled End) 1” – E019100 / E022100 1 ½” – E0191500 / E022150 2” – E019200 / E022200 3” – E019300 / E022300 4” – E019400 / E022400
30º Elbows: (Plain End / Belled End) 1” – E020100 / E072100 1 ½” – E020150 / E072150 2” – E020200 / E072200 3” – E020300 / E072300 4” – E020400 / E072400
|
1/8/10
|
|
Formerly Carlon
|
Prime Conduit
|
Standard Couplings: 1” – CP100 1 ½” – CP150 2” – CP200 3” – CP300 4” – CP400
90º Elbows 36” Radius for Power: (Plain End / Belled End) 2” – UA9FJ / UA9FJB 90º Elbows: (Plain End / Belled End) 1” – UA9AF / UA9AFB 1 ½” – UA9AH / UA9AHB 2” – UA9AJ / UA9AJB 3” – UA9AL / UA9ALB 4” – UA9AN / UA9ANB
45º Elbows: (Plain End / Belled End) 1” – UA7AF / UA7AFB 1 ½” – UA7AH / UA7AHB 2” – UA7AJ / UA7AJB 3” – UA7AL / UA7ALB 4” – UA7AN / UA7ANB
30º Elbows: (Plain End / Belled End) 1” – UA6AF / UA6AFB 1 ½” – UA6AH / UA6AHB 2” – UA6AJ / UA6AJB 3” – UA6AL / UA6ALB 4” – UA6AN / UA6ANB
|
5/26/09
|
|
RMC Conduit
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Allied Tube & Conduit
|
1” – 278895 1 ½” – 278911 2” – 278929 3” – 278945 4” – 278960
|
5/5/03
|
|
|
Sawhill Tubular Division
|
Steelduct 1” – 662535-19345-1 1 ½” – 662535-19347-5 2” – 662535-19349-9 3” – 662535-19351-2 4” – 662535-19353-6
|
4/11/00
|
|
|
Western Tube & Conduit Corp
|
1” – WTR3 1 ½” – WTR5 2” – WTR6 3” – WTR8 4” – WTR91
|
5/5/03
|
|
|
Wheatland Tube
|
1” – 05440 1 ½” – 05442 2” – 05443 3” – 05445 4” – 05447
|
5/5/03
|
|
|
Comment:
|
|
|
|
Galvanized Rigid Conduit Used only for extension of existing RMC conduit
|
RMC Fittings
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Conduit Pipe Products
|
Coupling Part Numbers 1 ½” – 00135 2” – 00136 3” – 00138 4” – 00140 90º Elbow Part Numbers 1 ½” – 00165 2” – 00166 3” – 00168 4” – 00170 45º Elbow Part Numbers 1 ½” – 00185 2” – 00186 3” – 00188 4” – 00190
|
5/5/03
|
|
|
Picoma Industries
|
Couplings, 90º Elbow and 45º Elbow in sizes: 1 ½”, 2”, 3”, 4”
|
5/5/03
|
|
|
Sawhill Tubular Division
|
Steelduct (Right and Left Threaded) Coupling Part Numbers 4”x4” – 20997
|
4/10/01
|
|
|
Sawhill Tubular Division
|
90º Elbow Part Numbers 3” – 21276 4” – 21279 45º Elbow Part Numbers 3” – 21271 4” – 21273
|
4/11/00
|
|
|
Shamrock Conduit Products
|
Coupling Part Numbers 1 ½” – 9001 2” – 0319 3” – 0321 4” – 0323 90º Elbow Part Numbers 1 ½” – 7746 2” – 7747 3” – 7749 4” – 7751 45º Elbow Part Numbers 1 ½” – 7654 2” – 7655 3” – 7657 4” – 7659
|
5/5/03
|
|
|
Comment:
|
|
|
|
Galvanized Rigid Conduit fittings Used only for extension of existing RMC conduit
|
RMC Bushings
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Arlington Industries
|
1 ½” – 454 2” – 455 3” – 457 4” – 459
|
1/11/02
|
|
|
Bridgeport
|
1 ½” – 385 2” – 386 3” – 388 4” – 390
|
5/5/03
|
|
|
Lazy-lug
|
1” – GLL-3C-B 1 ½” – GLL-5C-B 2” – GLL-6C-B 3” – GLL-8C-B 4” – GLL-10C-B
|
5/5/03
|
|
|
OZ-Gedney
|
1” – IBC-100L-4AC 1 ½” – IBC-150L-4AC 2” – IBC-200L-4AC 3” – IBC-300L-4AC 4” – IBC-400L-4AC
|
7/2/03
|
|
|
Regal Manufacturing
|
1 ½” – 8225 2” – 8226 3” – 8228 4” – 8230
|
5/5/03
|
|
|
Steel City / Thomas & Betts
|
1 ½” – BG-805 2” – BG-806 3” – BG-808 4” – BH-810
|
5/5/03
|
|
|
Comment:
|
|
|
|
Copper lug with insulated throat constructed of malleable iron. Threaded type
|
Bridge Expansion Couplings
Controller Cabinet
Pole Mount Traffic Signal Cabinet
Pad Mount Traffic Signal Cabinet
Single Input File Pad Mount Traffic Signal Cabinet
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
For Maintenance Use Only/or as Specified
|
McCain
|
Model OP332SI w/ slide out battery drawer UPS Battery Drawer 6
|
10/12/11
|
|
Double Pad Mount Traffic Signal Cabinet
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
For Maintenance Use Only/or as Specified
|
McCain
|
Model 333JP-OPKS
|
6/16/10
|
|
Safetran
|
Model 333SD-OPKS
|
6/16/10
|
|
|
Comment:
|
|
|
|
These should be fabricated to “Overland Park Special” configurations
|
Hybrid Double Pad Mount Traffic Signal Cabinet
|
Comment:
|
|
|
|
Reliance Controls Corp (30 A, 4-prong) External Generator Receptacle if specified
|
Hybrid Stretch Cabinet
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Safetran
|
Model 332Strech-OPKS
|
|
Pad Mount DMS Sign Cabinet
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Safetran
|
Model 334-OPKS
|
5/5/03
|
|
Detection Systems
Microloop Probes
Non-Invasive Vehicle Detectors Probes
Pedestrian Pushbuttons ADA Audible
|
Comment:
|
|
|
|
Red LED indicator Audible locator Auto volume adjustment for ambient noise levels EN4 – EZ Communicator Navigator 4 Wire system 3 – 9” x 15” Face Plate T – 9”x15” R10-3e High Intensity Sheeting Pushbutton Sign N – No Braille on Face Plate 1 – Custom Message (Recorded at Factory w/ electronic copy sent to City) PY – Yellow back and front housing
|
Pedestrian Pushbuttons
|
Comment:
|
|
|
|
Yellow body with sound on actuation NO LED Flash X = B for Black or Y for Yellow
|
Pre-empt Detectors
|
Comment:
|
|
|
|
Two Direction Single Channel
|
Pre-formed Loop Detectors
Advance Radar Detectors
|
Comment:
|
|
|
|
Include the SDLC Cabinet Interface Module Two SDLC Cabinet Interface Modules are required for more than 4 sensors
|
Presence Radar Detectors
|
Comment:
|
|
|
|
Include the SDLC Interface Module Two SDLC Cabinet Interface Modules are required for more than 4 sensors
|
Vehicle Detectors
|
Comment:
|
|
|
|
It shall have TS2 status output available
|
Video Detection Systems
Grounding Equipment
RJ-45 Data Protector
|
Comment:
|
|
|
|
Use with IP High Definition CCTV Cameras
|
Ground Rod
|
Comment:
|
|
|
|
½” x 10’-0” long at poles and controller cabinet ½” x 8’-0” long at service boxes Copper clad steel core UL listed
|
Ground Rod Clamp
|
Comment:
|
|
|
|
Hex head set screw Copper alloy Long bearing surface UL listed
|
Junction and Service Boxes
Type 1 Junction Box
|
Comment:
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 1 Piece cover to be ¾” min thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
Type 2 Junction Box
|
Comment:
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 1 Piece cover to be 2” thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
Type 1 Service Box
|
Comment:
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 1 Piece cover to be 3” thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
Type 2 Service Box
|
Comment:
|
|
|
|
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load) Logo to read “Traffic Signal” 2 Piece cover to be 3” thick underlapping Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers
|
LED Units
Red Ball LED
|
Comment:
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Yellow Ball LED
|
Comment:
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Green Ball LED
|
Comment:
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Countdown Pedestrian LED
|
Comment:
|
|
|
|
16” X 18” Orange Hand/White Man Incandescent look Filled/Overlay Style 9” Numerals
|
Red LED Arrow
|
Comment:
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Yellow LED Arrow
|
Comment:
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Green LED Arrow
|
Comment:
|
|
|
|
Tinted or clear lens is acceptable Incandescent look
|
Bi-Modal Green/Yellow LED Arrow
|
Comment:
|
|
|
|
Clear Lens, pixilated arrow
|
Loop Sealants
|
Comment:
|
|
|
|
Crafco sealant may only be used on loops sawed into the final surface of the pavement.
|
Miscellaneous Controller Equipment
170 Controller
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
Quixote Traffic Corp purchased US Traffic
|
IDC / US Traffic Corp / Quixote Traffic Corp
|
170E
|
5/503
|
|
|
Safetran
|
170E
|
5/5/03
|
|
|
Comment:
|
|
|
|
USED ONLY FOR MAINTENANCE
|
2070 Controller
|
Comment:
|
|
|
|
USED ONLY FOR MAINTENANCE
|
Rack Mount Controller
|
Comment:
|
|
|
|
with Data Key Modules: · 1 – 3B front panel · 1 – 2A field panel · 1 – 4A power supply · 1 - CPU module · Removable power cord Meets CalTrans Transportation Electrical Equipment Specifications August 2002 as revised October 27, 2003 ASC/2070 Firmware shall be provided with the controller
|
Bus Interface Unit (BIU)
|
Comment:
|
|
|
|
½ width design - Only used with Hybrid Cabinet
|
AC Isolator
Conflict Monitor
|
Comment:
|
|
|
|
Not used with Hybrid Cabinet. See “Malfunction Management Unit” below
|
DC Isolator
|
Comment:
|
|
|
|
Model 242 Not used with Hybrid Cabinet. See “Detector Test Switch Module” below.
|
K1 Control Relay
|
Comment:
|
|
|
|
Only used with Hybrid Cabinet
|
Flash Transfer Relay
Flasher Unit
Malfunction Management Unit (MMU)
|
Comment:
|
|
|
|
Only used in Hybrid traffic signal cabinet in place of the conflict monitor
|
Power Distribution Surge Protection Unit
|
Comment:
|
|
|
|
Room for 8 transformer spaced outlets (minimum) 15 amp breaker Rack mounted NEMA 5-15
|
Power Supply
|
Comment:
|
|
|
|
High efficiency power saving w/ solid state transfer relay
|
Power Distribution Assembly (PDA)
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
McCain
|
PDA#2 M63186
|
7/14/10
|
|
|
SafeTran
|
|
|
|
Pre-empt Phase Selectors / Discriminator Module
|
Comment:
|
|
|
|
With Ethernet Ports
|
Switchpack / Load Switch
Surge Protector (Traffic Signal Cabinet)
Utility Power Surge Protector (Secondary Service Enclosure)
|
Comment:
|
|
|
|
Note: NEMA-4 weather tight housing Output contacts Replaceable cartridge overcurrent fuse protection Replaceable modules Event timer
|
Mounting Brackets
Video Detection Camera Mounting Bracket for Luminaire Arm
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
Comments
|
|
Pelco Products, Inc.
|
SH-0502-10 w/ SE-4049 SH-0509-10 w/SE4049 Econolite
|
10/4/02
|
|
Narrow hub plate substituted for SE-4071 universal hub plate
|
|
Pelco Products, Inc.
|
EM-1109 EM-2200
|
10/31/05
|
|
The EM-1109 is for mounting on top of the luminaire arm The Em-2200 is a J-hook designed to mount below the luminaire arm
|
Video Detection Camera Mounting Bracket Side of Pole Mount
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Pelco
|
EM-2000
|
10/31/05
|
|
Video Detection Camera Mounting Bracket for Mast Arm
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Pelco Products, Inc.
|
AstroBrac AS-0175-5-62
|
10/4/02
|
|
Combined Video Detection Camera /Signal Head Mounting Bracket for Mast Arm
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Pelco Products, Inc.
|
AstroBrac AB-0608-74-L (4 Section)
|
|
|
Radar Detector Mounting Bracket
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Pelco Products, Inc.
|
AstroBrac SP-5772-PNC
|
7/24/12
|
|
|
Comment:
|
|
|
|
12 = Tube Length 84 = Cable Length P = Paint NC = No Coating
|
RWIS Sensor Mounting Bracket for Mast Arm
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Pelco Products, Inc.
|
AstroBrac AB-0164-12-84
|
1/28/11
|
|
|
Comment:
|
|
|
|
With 4-hole mounting plate 12 = Tube Length 84 = Cable Length (RWIS Manufacturer provides the PVC enclosure that mounts to the Tee pipe nipple)
|
Combined Radar Detector / RWIS Sensor Mounting Bracket for Mast Arm
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Pelco Products, Inc.
|
AstroBrac AB-0164-23-84 (SPECIAL) and SH0515
|
1/28/11
|
|
|
Comment:
|
|
|
|
With 4-hole mounting plate 23 = Tube Length 84 = Cable Length “SPECIAL” indicates the tube is threaded on each end The SH0515 mounting bracket for the radar unit needs to be drilled for a 5 hole configuration. An additional SH0515 mounting bracket is attached to the other threaded end for the RWIS unit. Only one Tee pipe nipple is required (RWIS Manufacturer provides the PVC enclosure that mounts to the Tee pipe nipple)
|
Mast Arm Signal Head Bracket
|
Comment:
|
|
|
|
Cable mount bracket assembly L=cable length (62”, 84”, or 96”) PNC=Process No Color
|
Side Mount Signal Head and Pedestrian Signal Head Bracket
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Auto/Eagle
|
UKS-1452X
|
5/5/03
|
|
|
Component Products, Inc.
|
TSP880-X
|
5/5/03
|
|
|
Gades
|
UKS1452X / PDM-405
|
5/5/03
|
|
|
Comment:
|
|
|
|
Yellow polycarbonate X=Y for Yellow X= B for Black
|
Mini Pre-empt Detector Bracket
|
Comment:
|
|
|
|
Cable mount L = Cable Length (45”, 62” or 84”) PNC = Process No Color
|
Poles
Aluminum Pedestal Poles
|
Comment:
|
|
|
|
See "Anchor Bolts" for part number information Pole tube is schedule 40 Include base collar with every pole Set screws required in base collar Include 2 7/8” OD x 7/8” ID galvanized flat washers Include anchor bolts
|
Galvanized Steel Signal Poles
|
Comment:
|
|
|
|
See "Anchor Bolts" for part number information Shall meet 1994 AASHTO or 2013 AASHTO Criteria as specified in the bid plans, documents and details
|
Pedestrian Pushbutton Pole and Foundation
|
Comment:
|
|
|
|
Hot dip galvanized finished smooth.
|
Pedestrian Push Button Pole Base Cover
|
Comment:
|
|
|
|
ABS Plastic. Square base with 3.5” diameter hole. Two-piece cover – natural aluminum
|
Power Backup Systems
CNG Generators
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Alpha Technologies
|
AlphaGen CE-3x2-50-48 NG with Cold Weather Starting Kit With PCC-3x Polymer Concrete Pre-Cast Pad Includes Alpha supplied battery
DO NOT PROVIDE WITH TRANSFORMER AND FUSE
|
6/17/03
|
|
|
Comment:
|
|
|
|
48V DC output voltage 96 amp max DC output current 10.5 Hp single OHV engine 13.5 VDC Ignition Charger Voltage 6 amp max Ignition Charger Current 2800 to 3600 RPM variable speed 80 CuFt/hr Natural Gas, 1000 BTU/CuFt 0.5 – 2 PSI Gas Inlet Pressure
|
UPS Systems
|
Comment:
|
|
|
|
Ethernet port capabilities See Battery requirements below. Use ONLY the specified batteries as listed for each UPS system as listed in the table below.
|
Power Transfer Switches
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Gen/Tran Corporation
|
TS300230PL
|
10/5/05
|
|
|
Comment:
|
|
|
|
Double Pole 30 Amp manual transfer switch Aluminum housing and #2 key Pilot light indicator
|
Batteries
Batteries for UPS
Batteries for CNG Generator
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
Comments
|
|
Alpha
|
Model 195 GXL
|
1/18/12
|
|
Gel Top AGM Terminal Battery (4 Year Full Replacement Warranty)
|
Secondary Service Pedestals
Aluminum Electrical Service Enclosure
|
Comment:
|
|
|
|
0.125” Aluminum, 30 amp breaker Corbin #2 lock on door No photocell or lighting relays Ringless Meter Socket with Horn By-Pass
|
Battery Backup / Electrical Service Enclosure
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Myers Custom Products, Inc.
|
Cabinet – MET2-PB-M030-AC-EMI Drawing No. F518506
|
8/23/05
|
|
USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Pacific Utility Products
|
Cabinet – USP29-57-BBS
|
7/9/10
|
|
USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Traffic Signal Controls
|
Cabinet – 2116UPME1401
|
9/3/09
|
|
|
Comment:
|
|
|
|
0.125” aluminum Manual transfer switch behind police door For use with external portable generator See below for External Generator Receptacle data 20Amp breaker for CCTV Camera Disconnect
|
Battery Backup to CNG Electrical Service Enclosure
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Myers Custom Products, Inc.
|
Cabinet – MET2-PB-M030-DC-EMI Drawing No. F518507
|
8/23/05
|
|
USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Pacific Utility Products
|
Cabinet – USP29-57-BBS
|
7/9/10
|
|
USED ONLY FOR MAINTENANCE REPLACEMENTS
|
Traffic Signal Controls
|
Cabinet-2116UPME1401
|
9/3/09
|
|
|
Comment:
|
|
|
|
0.125” aluminum For use with permanent CNG generator and gas service line 20Amp breaker for CCTV Camera Disconnect
|
CNG External Generator Receptacle
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
Hubbell
|
HBL2710SW including HBL2715 flanged receptacle
|
4/2/12
|
|
|
Reliance Controls
|
PK30 Power Inlet Kit, including L1430F flanged receptacle
|
4/2/12
|
|
|
Comment:
|
|
|
|
Twist Lock Recessed Male, 30 Amp 120/240 Volt, 4 prong including ground with outdoor hinged cover
|
Signal Heads
Signal Head Louvers
|
Comment:
|
|
|
|
Geometrically programmed louver with black visor X = 7, 8, 9, 11, 12, 15, 23.5 or 42 degrees depending on the cut-off angle desired. The maximum number of louvers comes with the 7 degree cut-off UC = Universal Clips P02 = Black
|
Vehicular Signal Heads
|
Comment:
|
|
|
|
Yellow Polycarbonate Body (Standard) Black Polycarbonate Body (Special) Black Polycarbonate Doors and Visors Visors to be Tunnel Type LED retrofit 12” Sections
|
Countdown Pedestrian Signal Heads
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
McCain Traffic Supply
|
M31466 – Yellow housing M31655 – Black housing
|
12/30/04
|
|
|
Siemens
|
SG7-S-Z10COYBB010 – Yellow housing SG7-S-Z10COBBB010 – Black housing
|
9/20/11
|
|
|
Comment:
|
|
|
|
Yellow polycarbonate body (Standard) Black polycarbonate body (Special) Black Aluminum Door / No Z-Crate Visor Port hole mount
|
Wire Connectors
Wire Connectors for Loop Lead-In
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
King Innovation/Dryconn
|
KB – Aqua/Blue Waterproof Connector 62310 – Card of 3 62325 – Bag of 15 62335 – Bag of 50 62340 – 250
|
10/14/03
|
|
|
Comment:
|
|
|
|
Wire Range: Min. #14 / Max. #6 Copper Silicone Sealant Filled Watertight/raintight
|
Wire Connectors for Multi-Conductor Signal Cable
Notes
|
Manufacturer
|
Catalog Number
|
Approval Date
|
Photos
|
|
King Innovation/Dryconn
|
King 6 Blue Waterproof Connector 10600 – Card of 2 10666 – Bag of 10
|
10/14/03
|
|
|
Comment:
|
|
|
|
Wire Range: Min. #22 / Max. #8 Copper Silicone Sealant Filled Direct Burial
|
|