Approved Materials - Specialty Items

From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation Jump to search
Return to Approved Materials
Side arrow 80x66.png


GeekNotesIcon.png Note: This document is provided as a benefit to contractors and suppliers who are bidding projects for the City of Overland Park. Only products identified on this list will be approved for installation on City construction projects. This list shall not be used as a substitute for catalog cuts or material approval. All material approvals shall be submitted on the approved City of Overland Park Contract Project Submittal form. The form is available at City Hall by contacting Bruce Wacker at (913) 895-6027. Failure to comply will be cause for rejection of materials until proper submittals are received. This list is updated periodically. The contractor or supplier shall contact the City of Overland Park to make sure that they have the most current list prior to bidding a project. Failure to do so shall not constitute a legitimate claim for change orders. Before accessing any links, the City recommends that the user delete browsing history to insure the latest catalog cut information is displayed correctly.

Permanent Signing Speciality Items

GeekNotesIcon.png Note: All materials listed on this Specialty Items page are not standard and shall require variance or special permission by the City to incorporate into projects.
The following items should be listed on the Contractor Submittal for Street Lighting form.

LED Sign Borders

91st St and Glenwood

Notes Manufacturer Catalog Number Approval Date Photos
TraffiCalm Controller & 30W Solar Panel
M75-SA300-BSC3
36" Stop Sign Flasher Ring
M75-R3636-WR01
7/23/21 Cable Connection
LED Border
Controller
Solar Panel

Streetlighting Speciality Items

GeekNotesIcon.png Note: All materials listed on this Specialty Items page are not standard and shall require variance or special permission by the City to incorporate into projects.
The following items should be listed on the Contractor Submittal for Street Lighting form.

Bollards

Downtown Streetscape

Notes Manufacturer Catalog Number Approval Date Photos
KIM Lighting VRB1-20L4KUV-BL 4/9/20 Bollard

Bracket Arms

Residential Side Mount Streetlight Adapter Arm for Small Cell Pole

Notes Manufacturer Catalog Number Approval Date Photos
Sentry SAL-WSB-PB 3/26/19
Comment:
Used only on small cell poles in areas with residential post top luminaires - Black

Slip Fitter Arm at Indian Creek Recreation Center Parking Lot

Notes Manufacturer Catalog Number Approval Date Photos
Valmont 1HT90H24 3/21/16

Decorative Light Bases

Indian Creek Park Recreation Center Parking Lot

Notes Manufacturer Catalog Number Approval Date Photos
Valmont CH22AC-DBL 3/21/16

Light Fixtures

Specialty luminaires shall have stickers denoting pertinant information on the luminaire housing when feasible as described below. Specialty luminaires shall have a specialty label based on LED class, light distribution type, and kelvin on fixture housing. Sticker label shall read:

XTY

ZK

Where X = LED Class (A, B, C, D, E); Y = Light Distribution Type (2, 3, 4, 5); and Z = Kelvin, in thousands (3, 4, 5). Some possible examples of these combinations are shown below.

Luminaire Housing Sticker Designs.jpg
Possible Specialty Luminaire Sticker Combinations

Myron Scafe, Jack Sanders, and Westgate Parking Lots

Notes Manufacturer Catalog Number Approval Date Photos
American Electric Lighting Autobahn ATB2

Class A:
Standard Gray Finish:
None currently installed.
Special Black Finish:
None currently installed.

IES File: ATB2_80B_LED_E70_XXXXX_R#.ies

Class B:
Standard Gray Finish, Type 3 Distribution, 4,000 Kelvin:
ATB2-60BLEDE70-MVOLT-R3-IL-NL-P7-SH-RFD310023
Installed at Sanders (MR-1883) and Scafe (MR-1882).
Standard Gray Finish, Type 4 Distribution, 4,000 Kelvin:
ATB2-60BLEDE70-MVOLT-R4-IL-NL-P7-SH-RFD310024
Installed at Sanders (MR-1883) and Scafe (MR-1882).
Special Black Finish:
None currently installed.

IES File: ATB2_60B_LED_E70_XXXXX_R#.ies

Class C:
Standard Gray Finish, Type 4 Distribution, 4,000 Kelvin:
ATB2-40BLEDE70-MVOLT-R4-IL-P7-SH-RFD328772
Proposed at City parking lot east of Marty and north of 80th St (SL-2550).
Special Black Finish:
None currently installed.

IES File: ATB2_40B_LED_E70_XXXXX_R#.ies

Autobahn ATB0
Class D:
Standard Gray Finish:

None currently installed.
Special Black Finish:
None currently installed.

IES File: ATB0_30B_LED_E70_XXXXX_R#.ies

Class E:
Standard Gray Finish:

None currently installed.
Special Black Finish, Type 3 Distribution, 4,000 Kelvin:
ATB0-20BLEDE70-MVOLT-R3-IL-P7-SH-RFD223679-RFWD6463
Installed at Westgate (MR-1762).

IES File: ATB0_20B_LED_E70_XXXXX_R#.ies
Approved as part of project MR-1882 and MR-1883 plans in 2020. Top View

Bottom View
Side View
Back View
Bird Guard
Driver Compartment
Wiring Compartment
Wiring Terminal
Level Bubble
Housing Latch

Comment:
10 Year Warranty.
CCT = 4,000K.
Light distribution optic type = Varies.
7 Pin twistlock photocell receptacle with shorting cap.
For design purposes, correct photometric file is listed for each fixture. Download the file from the manufacturer's web page.
Shall have specialty label based on LED class, light distribution type, and kelvin on fixture housing. Sticker label shall read:
XTY
ZK
Where X = LED Class (A, B, C, D, E); Y = Light Distribution Type (2, 3, 4, 5); and Z = Kelvin, in thousands (3, 4, 5).

City Hall, Deanna Rose Farmstead, Fire Training Center, Soccer Complex, Blue Valley Maintenance, St. Andrews, and Tomahawk Ridge Parking Lots

Notes Manufacturer Catalog Number Approval Date Photos
Classes were approximated to typical streetlight LEDs based on lumen output. NLS Lighting NV Series

Class C:
Various Color Finishes, Type 4 Distribution, 5,000 Kelvin:
NV1-T4-32L-1-50k

IES File: NV-1-T4-32L-1-50K.IES

Class D:
Black Finish, Type 4 Distribution, 5,000 Kelvin:
Soccer Complex Short Poles
NV1-T4-16L-1-50k

IES File: NV-1-T4-16L-1-50K.IES
Approved as part of PB-2068 project in 2022.
Comment:
CCT = 5,000K.
Light distribution optic type = Varies.
For design purposes, correct photometric file is listed for each fixture. Download the file from the manufacturer's web page.
Shall have specialty label based on LED class, light distribution type, and kelvin on fixture housing. Sticker label shall read:
XTY
ZK
Where X = LED Class (A, B, C, D, E); Y = Light Distribution Type (2, 3, 4, 5); and Z = Kelvin, in thousands (3, 4, 5).

Deanna Rose Farmstead East Lot, Jack Sanders, and St. Andrews Tennis Courts

Notes Manufacturer Catalog Number Approval Date Photos
Classes were approximated to typical streetlight LEDs based on lumen output. NLS Lighting NV Series

Class C:
Various Color Finishes, Type 2 Distribution, 4,000 Kelvin:
NV1-T2-32L-1-40k

IES File: NV-1-T2-32L-1-40K.IES

Various Color Finishes, Type 5 Distribution, 4,000 Kelvin:
NV1-T5-32L-1-40k

IES File: NV-1-T5-32L-1-40K.IES
Approved as part of PB-2068 project in 2022.
Comment:
CCT = 4,000K.
Light distribution optic type = Varies.
For design purposes, correct photometric file is listed for each fixture. Download the file from the manufacturer's web page.
Shall have specialty label based on LED class, light distribution type, and kelvin on fixture housing. Sticker label shall read:
XTY
ZK
Where X = LED Class (A, B, C, D, E); Y = Light Distribution Type (2, 3, 4, 5); and Z = Kelvin, in thousands (3, 4, 5).

Dennis Garrett

Notes Manufacturer Catalog Number Approval Date Photos
Leotek GreenCobra GCL1

Class A:
Standard Gray Finish:
GCL1-80J-MV-40K-5-GY-220-PCR7-CR-RWG-BBL-OPWL-LSSP2-LLPC

IES File: GCL1-80J-MV-40K-5-XX-220 S.ies

Class B
Standard Gray Finish:
GCL1-80J-MV-40K-4-GY-190-PCR7-CR-RWG-BBL-OPWL-LSSP2-LLPC

IES File: GCL1-80J-MV-40K-4-XX-190 S.ies

GreenCobra Midsize GCM1
Class C Type 2:
Standard Gray Finish:

GCM1-60J-MV-40K-2R-GY-125-PCR7-CR-RWG-BBL-OPWL-LSSP2-LLPC

IES File: GCM1-60J-MV-40K-2R-XX-125 S.ies

Class C Type 4:
Standard Gray Finish:

GCM1-60J-MV-40K-4-GY-125-PCR7-CR-RWG-BBL-OPWL-LSSP2-LLPC

IES File: GCM1-60J-MV-40K-4-XX-125 S.ies

Class D:
Standard Gray Finish:

GCM1-60J-MV-40K-4-GY-105-PCR7-CR-RWG-BBL-OPWL-LSSP2-LLPC

IES File: GCM1-60J-MV-40K-4-XX-105 S.ies
Approved as part of PB-2068 project in 2022.
Comment:
CCT = 4,000K.
Light distribution optic type = Varies.
For design purposes, correct photometric file is listed for each fixture. Download the file from the manufacturer's web page.
Needs a photocell on top as there is no cabinet controlling the lights with a photocell.
Shall have specialty label based on LED class, light distribution type, and kelvin on fixture housing. Sticker label shall read:
XTY
ZK
Where X = LED Class (A, B, C, D, E); Y = Light Distribution Type (2, 3, 4, 5); and Z = Kelvin, in thousands (3, 4, 5).

Antioch & I-435 Bridge Decorative Fixture

Notes Manufacturer Catalog Number Approval Date Photos
Bega 8189P-Blk-120 w/ GE 12870 Fluorescent lamp
Shop Drawing
7/21/04
Comment:
120 Volt, Black, Fluorescent lamp

110th Street & Lamar Roundabout Decorative Fixture

Notes Manufacturer Catalog Number Approval Date Photos
Type III Distribution, LED, Black.
7 Pin twistlock photocell receptacle with shorting cap.
Approximately Class B lumen output.
Acuity Lithonia RSX1 3/21/2022
These are for replacement
of existing heads only.
This fixture is no longer approved.

Type II Distribution, 400W MH, Black
Gardco Lighting Gullwing #G18-1-2XL-400-MH-240-BLP 4/26/02
Comment:
Shall have specialty label based on LED class, light distribution type, and kelvin on fixture housing. Sticker label shall read:
XTY
ZK
Where X = LED Class (A, B, C, D, E); Y = Light Distribution Type (2, 3, 4, 5); and Z = Kelvin, in thousands (3, 4, 5).

110th & Lamar Roundabout Landscape Fixture

Notes Manufacturer Catalog Number Approval Date Photos
Hydrel 4710A-175M-120-SP-ISSDLA-BZ 4/26/02
Comment:
175W MH, Bronze

Wall Packs

Notes Manufacturer Catalog Number Approval Date Photos
Installed at:
Locations TBD along US-69 ETL Project
Discontinued prior to any installs.
Holophane W4GLED 30C1000 40K T3M MVOLT SPD PR7 AO SHU 3/21/2023
Installed at:
Antioch & I-435 Bicycle Tunnel
Indian Creek Bicycle Trail under I-435
These are for replacement of existing Liton heads only.
Liton WLP32-120W 6/27/2023 Side
Comment:
Adjustable Output is approved.
For use in tunnels and bridge underpasses.
Trail lighting separate from an adjacent roadway will be designed with adjustable output codes to adjust the average maintained illuminance between 1.0 footcandle and 3.7 footcandle and a 3:1 average:minimum uniformity.

Soffit Lights

Notes Manufacturer Catalog Number Approval Date Photos
Installed at:
Locations TBD along US-69 ETL Project
Holophane PPSQL2-P20-40K-MVOLT-GL-T5R-SSM-AO
PPSQL2-P80-40K-MVOLT-GL-T5R-SSM-AO
9/22/2023
Comment:
Adjustable Output is approved.
For use in tunnels and bridge underpasses.
Trail lighting separate from an adjacent roadway will be designed with adjustable output codes to adjust the average maintained illuminance between 1.0 footcandle and 3.7 footcandle and a 3:1 average:minimum uniformity.

133rd & Lamar; 132nd Street & US-69 Overpass; Vineyards and Mills Farm Roundabouts

Notes Manufacturer Catalog Number Approval Date Photos
These are for replacement
of existing heads only.
This fixture is no longer approved.
Architectural Area Lighting PRMSH3150HPS-Mogul-240MT-BLK-06A-1814 Sleeve 8/28/06
Comment:
Promenade – Black
Mogul base lamp and reflector system

Photometric curve
PRM3-H2-150HPS.IES

Matt Ross Community Center Parking Lot Fixture

Notes Manufacturer Catalog Number Approval Date Photos
Wide Lite/
Genlyte Company
Optra Area Luminaire
Symmetric Distribution:
OPP-250-S-QV-SR-SA
Asymmetric Distribution:
OPP-250-A-QV-SR-SA
3/16/06
Comment:
250W MH
Segmented reflector with vertical lamp
Multi-tap ballast
Satin Aluminum finish
Arm mount to round pole

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Downtown OP

Notes Manufacturer Catalog Number Approval Date Photos
Sentry SGO-150HPS-240V-MT-III-BK (No Finial)
IES File: SGO-150HPS-III
5/5/03

95th St & Nall Ave;
71st St & Metcalf Ave;
75th St & Metcalf Ave;
87th St & Metcalf Ave

Notes Manufacturer Catalog Number Approval Date Photos Comments
This fixture is no
longer being manufactured.
KIM Lighting KIM Era Lantern
1A/LET26SCH3/400HPS240/**
HA33L-TM1/HF2/HAF2

This has to be a tenon mount
because of the fluted signal pole shaft
1/26/09 Single Top Mounted, Single Curved Arm,
400W HPS, 240V, Type III Distribution
TM!= Tenon Mount Ribbon Arm
HF2/ HAF2 = Two Finials
** = Custom Color
RAL 6012 (Hunter Green)
BL (Black FED-STD-595 #27038)

79th St & Metcalf Ave

Notes Manufacturer Catalog Number Approval Date Photos
This fixture is no
longer being manufactured.
KIM Lighting KIM Era Lantern
1A/LET26SCH3/250HPS240/**/BF
HA33L/**/HAF2

This does not require a tenon because
the pole is not fluted.
2/26/13
Comment:
Single Top Mounted
Single Curved Arm
250W HPS, 240V, Type III Distribution
HAF2 - Finial on the top arm stud
** - Custom Color
RAL 8019 Dark Bronze

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

159th Street Bridge Over US-69 Highway

Notes Manufacturer Catalog Number Approval Date Photos
This fixture is no
longer being manufactured.
KIM Lighting KIM Era Lantern
FM/LEB26SCH3/400HPS240/**/TF
Should accommodate 4.5” top pole O.D. w/ 0.188” wall
12/13/10
Comment:
Post Top Flush Mounted
Single Curved Arm
Top Finial
400W HPS, 240V, Type III Distribution
** BL (Black FED-STD-595 #27038)

127th Street (Metcalf Ave to Nall Ave)

Notes Manufacturer Catalog Number Approval Date Photos
This fixture is no
longer being manufactured.
KIM Lighting KIM Era Lantern
2B/LET26SCH3/250HPS240/**/BF
Twin Bracket Arms @ 180 degrees
2B/HA33L/HAF2
12/13/10
Comment:
Twin Top Mounted
Single Curved Arm
Bottom Finial
250W HPS, 240V, Type III Distribution
Ribbon Arm w/ top finial
** BL (Black FED-STD-595 #27038)

95th St & Quivira, 95th St & Oak Park East, and 95th St & Nieman Rd Intersections on Joint Use Signal Poles

Notes Manufacturer Catalog Number Approval Date Photos
KIM Lighting KIM Warp 9 HPS – Single w/2” slipfitter for Type A or B arm
1A/WP9LM3/400HPS240/CC/HSF/TB
8/2/09
Comment:
400W HPS, 240V
Type III Distribution
CC - Custom Color (RAL 6012 Hunter Green)

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Quivira Road: 95th St. to 99th St.

Notes Manufacturer Catalog Number Approval Date Photos
KIM Lighting KIM Warp 9 HPS – Twin Std Arms
2B/WP9LM3/400HPS240/CC/TB
KIM Warp 9 HPS – Single Std Arm
1A/WP9LM3/250HPS240/CC/TB
8/2/09
Comment:
250W or 400W HPS, 240V
Type III Distribution
CC - Custom Color (RAL 6012 Hunter Green)

Outdoor Electrical Connections

Outdoor Receptacle Covers

Notes Manufacturer Catalog Number Approval Date Photos
ABB CKMUV 11/1/2021 Front
Side
Open
Comment:
NEMA 3R
While-In-Use
Metal
Large enough to fit two electrical extension cords while the cover is fully closed

Outdoor Receptacles

Notes Manufacturer Catalog Number Approval Date Photos
Hubbell GFTW20W 11/1/2021
Leviton GFWT2 11/1/2021
Comment:
GFCI
Commercial grade
Designed for wet and damp locations
Tamper-Resistant
LED status indicator

Photocell

System Photocell Receptacle

Notes Manufacturer Catalog Number Approval Date Photos
Acuity DUR103 11/9/2022 Top View

Side View
Bottom View

Comment:
Used on external disconnects for city buildings.

Poles

Special Light Poles for City Parking Lots

Notes Manufacturer Catalog Number Approval Date Photos
Valmont Dwg No. A42365 – Revision 3 - 05/31/23 7/27/2020
Comment:
Pole height is 31'
Designed for mounting lots of IT equipment
Field drilled 2" max dia holes shall be a minimum of 12" above and 90 degrees from the hand hole
Nylon hand hole screws
Poles installed at Sanders, Scafe, and Fire Station 41

Special Light Poles for Indian Creek Recreation Center Parking Lot

Notes Manufacturer Catalog Number Approval Date Photos
Valmont R-290845806T4-P9-DBL 3/21/2016

110th Street & Roundabout Square Pole

Notes Manufacturer Catalog Number Approval Date Photos
Gardco Lighting #SSS 30-5-11-BLP 4/26/02
Comment:
5” square, straight, steel - Black

Matt Ross Community Center Parking Lot Pole

Notes Manufacturer Catalog Number Approval Date Photos
KW Industries RSP18-4.0-11-NA-DM10-BC 3/21/06
Comment:
Round Steel
Satin Aluminum finish
Arm mount option

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Decorative Poles for Downtown OP and 132nd Street Bridge over US-69 Highway

Notes Manufacturer Catalog Number Approval Date Photos
Hapco Dwg No. C19043 – 8/3/10 8/5/10 Base
Handhole
Bolt Cover
Comment:
Nylon hand hole screws

Special Pole for 159th Street Bridge over US-69 Highway

Notes Manufacturer Catalog Number Approval Date Photos
Hapco Dwg No. SKKP110211B -1 11/2/11 11/11/11
Valmont Dwg No. LH30800 – 10/17/11 11/1/11
Comment:
Shaft Length is 29’-3” or 39’-3” as specified
Color: Black FED-STD-595 #27038 or Hunter Green # RAL 6012

Special Pole for Era Lantern Bolt Pattern 127th St (Metcalf to Nall)

Notes Manufacturer Catalog Number Approval Date Photos
Hapco OP301-LANTERN
Dwg No. SKKP110211A-001 –Single
Dwg No. SKKP110211A-002 – Twin
OP401-LANTERN
Dwg No. SKKP012011A-001 –Single
Dwg No. SKKP012011A-002 – Twin
Pole Cap & Finial – F0004
11/11/11
Valmont OP301-LANTERN
OP401-LANTERN
11/2/11
Comment:
Shaft Length is 29’-3” or 39’-3” as specified
Pole Cap & Finial
Color: Black FED-STD-595 #27038 or Hunter Green # RAL 6012

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Special Pole for Warp9 Bolt Pattern Quivira Rd (99th to 95th)

Notes Manufacturer Catalog Number Approval Date Photos
Hapco OP301-WARP
Dwg No. SKKP110211C-001 – Single
Dwg No. SKKP110211C-002 – Twin
OP401-WARP
Dwg No SKKP013111A-001 – Single
Dwg No SKKP013111A-002 – Twin
11/11/11
Valmont OP301-WARP
OP401-WARP
11/2/11
Comment:
Shaft Length is 29’-3” or 39’-3” as specified
Color: Black FED-STD-595 #27038 or Hunter Green # RAL 6012

Screw-In Foundations

Screw-In Foundations for Downtown OP Pole

Notes Manufacturer Catalog Number Approval Date Photos
AB Chance T112-03631701
Dwg No. SA11203631701 Rev A
8/5/10
Comment:
Used with Hapco Decorative Pole

Traffic Signal Speciality Items

GeekNotesIcon.png Note: All materials listed on this Specialty Items page are not standard and shall require variance or special permission by the City to incorporate into projects.
The following items should be listed on the Contractor Submittal for Traffic Signals form.

Decorative Signal Poles

Mast Arm Poles

Notes Manufacturer Catalog Number Approval Date Photos Comments
95th St & Nall Ave Valmont Pole: Tapered, 16-Sharp Fluted w/ 2.875” OD x 4” L Tenon
Mast Arm: Smooth Round Tapered
Pole Cap: Standard
Finish/Color: F-306-GG
Metcalf Corridor,
Excluding Downtown Form Based Code Extents
Valmont Pole: Tapered, 16-Sharp Fluted w/ 2.875” OD x 4” L Tenon
Mast Arm: Smooth Round Tapered
Pole Cap: Metro Series
Finish/Color: F-306-B
Metcalf Corridor,
Within Downtown Form Based Code Extents (Inclusive)
Valmont Pole: Tapered, 16-Sharp Fluted w/ 2.875” OD x 4” L Tenon
Mast Arm: Smooth Round Tapered
Pole Cap: Metro Series
Finish/Color: F-306 / RAL 8019 Medium Bronze
Oak Park Mall
Signals along 95th St and Quivira;
95th & Nieman
Valmont Standard pole and mast arm
Pole Cap: Spear Series
Finish/Color: F-306-GG
Comment:
Color Codes:
GG = RAL 6012 OP Green
B = Fed-Std-595 #27038 Black

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Pedestal Poles

Notes Manufacturer Catalog Number Approval Date Photos Comments
83rd St & Metcalf Ave Valmont Pole: Straight, Round, Smooth
Pole Cap: Metro Series
Color: Fed-Std-595 #27038 Black
95th St & Nall Ave Valmont Pole: Straight, 16-Flat Fluted Color: RAL 6012 OP Green
Metcalf Corridor,
Excluding Downtown Form Based Code Extents
Valmont Pole: Straight, 16-Flat Fluted
Pole Cap: Metro Series
Finish/Color: Fed-Std-595 #27038 Black
Finish: Powder Coat
Metcalf Corridor,
Within Downtown Form Based Code Extents (Inclusive)
Valmont Pole: Straight, 16-Flat Fluted
Pole Cap: Metro Series
Color: RAL 8019 Medium Bronze
Finish: Powder Coat
Oak Park Mall Signals
along 95th St and Quivira;
95th & Nieman
Valmont 4 ½” dia straight pole
Pole Cap: Spear Series
Color: RAL 6012 OP Green
Finish: Powder Coat
Comment:
Color Codes:
GG = RAL 6012 OP Green
B = Fed-Std-595 #27038 Black
Round and Fluted Poles are Spun Aluminum

Decorative Bases for Mast Arm Poles

Notes Manufacturer Catalog Number Approval Date Photos Comments
Oak Park Mall Signals
along 95th St and Quivira;
95th & Nieman
Valmont Contour Series
CN20AC, CN27AC & CN34AC
Color: RAL 6012 OP Green
Finish: Powder Coat
95th St & Nall Ave Valmont Washington Series
WA25AB, WA30AB & WA36AB
Color: RAL 6012 OP Green
Finish: Powder Coat
Metcalf Corridor,
Excluding Downtown Form Based Code Extents
Valmont Sterling Series
|ST24AB, ST25AB & ST31AB
Color: Fed-Std-595 #27038 Black
Finish: Powder Coat
Metcalf Corridor,
Within Downtown Form Based Code Extents (Inclusive)
Valmont Sterling Series
|ST24AB, ST25AB & ST31AB
Color: RAL 8019 Medium Bronze
Finish: Powder Coat
Metcalf Corridor,
Within Downtown Form Based Code Extents (Inclusive)
83rd St, 81st St HAWK/PHB
Valmont Huntington Series
Color: Fed-Std-595 #27038 Black
Finish: Powder Coat

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Decorative Bases for Pedestrian Poles

Notes Manufacturer Catalog Number Approval Date Photos Comments
Oak Park Mall Signals along
95th St and Quivira;
95th & Nieman
Valmont Contour Series
CN18AC
Color: RAL 6012 OP Green
Finish: Powder Coat
95th & Nall Valmont Washington Series
WA18AB
Color: RAL 6012 OP Green
Finish: Powder Coat
Metcalf Corridor,
Excluding Downtown Form Based Code Extents
Valmont Sterling Series
ST18AB
Color: Fed-Std-595 #27038 Black
Finish: Powder Coat
Metcalf Corridor,
Within Downtown Form Based Code Extents (Inclusive)
Valmont Sterling Series
ST18AB
Color: RAL 8019 Medium Bronze
Finish: Powder Coat
Metcalf Corridor,
Within Downtown Form Based Code Extents (Inclusive)
83rd St, 81st St HAWK/PHB
Valmont Huntington Series
Color: Fed-Std-595 #27038 Black
Finish: Powder Coat
Round, Non-tapered
There are non-public model numbers including increased pole wall thicknesses. Have manufacturer provide model number based on loading.
Comment:
Recommend using Valmont's integrated decorative base and pole rather than trying to add a decorative base over a standard pedestal pole. This improves ease of access to wires in base.

Pedestrian Pushbutton Pole

Pedestrian Pushbutton Pole and Foundation

Notes Manufacturer Catalog Number Approval Date Photos
Maintenance Only AB Chance Screw-in-Foundation:
T1121363 / Dwg No. SA1121363
Ped Button Post:
T1121364 / Dwg No. SA1121364
10/21/11
Comment:
Hot dip galvanized finished smooth.

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Pole Base Cover

Notes Manufacturer Catalog Number Approval Date Photos
Lithonia RSS FBC 3-5IN RND JMA 1751 DNA 1/7/13
Comment:
ABS Plastic. Square base with 3.5” diameter hole.
Two-piece cover – natural aluminum


Solar Traffic Signal Equipment

Batteries

Notes Manufacturer Catalog Number Approval Date Photos
Concorde Battery Corp
Sun Xtender
Sun Xtender Series 3/25/22
Comment:
Size depends on the specific job requirements

Confimirmation Light

Notes Manufacturer Catalog Number Approval Date Photos
Tomar Electronics 801 Mini I Strobe 3/25/22

Control Unit

Notes Manufacturer Catalog Number Approval Date Photos
Solar Traffic Controls DPC-2000 3/25/22

DC LED Kits

Notes Manufacturer Catalog Number Approval Date Photos
Solar Traffic Controls 12" Amber: 8412A2385 3/25/22

Solar Cabinet Enclosure

Notes Manufacturer Catalog Number Approval Date Photos
Solar Traffic Controls 2B Enclosure 3/25/22

Solar Panel

Notes Manufacturer Catalog Number Approval Date Photos
Ameresco Solar 60W Solar Panel: Model- 60J 3/25/22
Comment:
Wattage and Size depends on the specific job requirements

Smart Relay

Notes Manufacturer Catalog Number Approval Date Photos
IDEC Corp xxxxx 3/25/22

Strobeswitch

Notes Manufacturer Catalog Number Approval Date Photos
Tomar Electronics 1790-1014 3/25/22

Biking Speciality Items

GeekNotesIcon.png Note: All materials listed on this Specialty Items page are not standard and shall require variance or special permission by the City to incorporate into projects.
The following items should be listed on the Contractor Submittal for Permanent Signing form.

Bike Racks - OP Decorative

Downtown OP

Notes Manufacturer Catalog Number Approval Date Photos
Dero 1004374-A Ground Mount

1004373-A Surface Mount

10/10/2022 Hitch

Installed

Comment:
In-ground mount has held up better than the surface mount.

EV Charging Speciality Items

GeekNotesIcon.png Note: All materials listed on this Specialty Items page are not standard and shall require variance or special permission by the City to incorporate into projects.
The following items should be listed on the Contractor Submittal for Streetlighting form.

Electrical Meter Control Center

Electrical Meter Control Center

Notes Manufacturer Catalog Number Approval Date Photos
Approved for use at:

Scheels Soccer Complex
Deanna Rose Children's Farmstead
Arboretum & Botanical Gardens

Milbank CP3B54C1ERAOSP1 9/20/2022
Comment:
None.