Difference between revisions of "Approved Materials - Storm Drainage"
Jump to navigation
Jump to search
Zach Matteo (talk | contribs) |
Zach Matteo (talk | contribs) |
||
Line 55: | Line 55: | ||
| align="center" colspan="6"|''Castings from overseas shall have the coupon as required in AASHTO M-306 for testing.'' | | align="center" colspan="6"|''Castings from overseas shall have the coupon as required in AASHTO M-306 for testing.'' | ||
|- | |- | ||
| | | East Jordan Iron Works||1502 A and Z||Heavy Duty | ||
|1502 A and Z||Heavy Duty | |||
|align="center"|4/11/2006||||[[Media:AML ManholeCover EJI1502.pdf|1502]] | |align="center"|4/11/2006||||[[Media:AML ManholeCover EJI1502.pdf|1502]] | ||
|- | |- | ||
||1501 A and Z||Medium Duty | | NACIP||N-207P||Heavy Duty | ||
|align="center"|4/11/2006||||[[Media:AML ManholeCover NACIP207.PDF|N-207P]] | |||
|- | |||
| GCI Castings||SM 2206 OP||Heavy Duty | |||
|align="center"|4/28/2006||||[[Media:AML ManholeCover GCI2206.pdf|SM 2206 OP]] | |||
|- | |||
| Deeter||1320||Heavy Duty | |||
|align="center"|4/28/2006||||[[Media:AML ManholeCover Deeter1320.pdf|1320]] | |||
|- | |||
| Clay and Bailey||2007-01-6032/2007-01-6050||Heavy Duty | |||
|align="center"|5/30/2007||||[[Media:AML ManholeCover ClayandBailey2007pdf.pdf|2007]] | |||
|- | |||
| Sigma||MH-207OP-35||Heavy Duty | |||
|align="center"|2/17/2010||||[[Media:AML ManholeCover 207OP-35.pdf|207OP-35]] | |||
|- | |||
| East Jordan Iron Works||1501 A and Z||Medium Duty | |||
|align="center"|4/11/2006|| ||[[Media:AML ManholeCover EJI1501.pdf|1501]] | |align="center"|4/11/2006|| ||[[Media:AML ManholeCover EJI1501.pdf|1501]] | ||
|- | |- | ||
| NACIP||N-220P||Medium Duty | |||
| | |align="center"|4/11/2006||||[[Media:AML ManholeCover NACIP220.pdf|N-220P]] | ||
| | |- | ||
|align="center"| | | GCI Castings||SM 2100 OP||Medium Duty | ||
|align="center"|4/28/2006||||[[Media:AML ManholeCover GCI2100.pdf|SM 2100 OP]] | |||
|- | |||
| Deeter||2016||Medium Duty | |||
|align="center"|4/28/2006||||[[Media:AML ManholeCover Deeter2016.pdf|2016]] | |||
|- | |- | ||
||2020-01-6032/2020-01-6050||Medium Duty | | Clay and Bailey||2020-01-6032/2020-01-6050||Medium Duty | ||
|align="center"|4/12/2007||||[[Media:AML ManholeCover ClayandBailey2020.pdf|2020]] | |align="center"|4/12/2007||||[[Media:AML ManholeCover ClayandBailey2020.pdf|2020]] | ||
|- | |- | ||
| Sigma||MH-202OP-35||Medium Duty | |||
||MH-202OP-35||Medium Duty | |||
|align="center"|2/17/2010||||[[Media:AML ManholeCover 202OP-35.pdf|202OP-35]] | |align="center"|2/17/2010||||[[Media:AML ManholeCover 202OP-35.pdf|202OP-35]] | ||
|- | |- |
Revision as of 12:39, 7 April 2017
Return to Preapproved Materials
Inlet Frames
Applicable Specification:
Overland Park Standard Details |
Manufacturer | Product Name or Number | Approval Date | Comment | Catalog Cut Links |
Shawnee Steel & Welding Inc. | Curb Inlet 10” Throat | 12/15/2005 | Curb Inlet 10” Frame | |
Shawnee Steel & Welding Inc. | Area Inlet 10” Throat | 1/4/2006 | Area Inlet 10” Frame |
Manhole Steps
Applicable Specification:
Overland Park Standard Details (Precast Manhole Detail) Overland Park Construction Specifications - Chapter 33 |
Manufacturer | Product Name or Number | Approval Date | Comment | Catalog Cut Links |
American Step | ML-13 | 3/27/2017 | ML-13 | |
American Step | ML-10 | 3/27/2017 | ML-10 | |
MA Industries | PS1-PF | 3/27/2017 | PS1-PF | |
MA Industries | PS2-PF | 3/27/2017 | PS2-PF |
Manhole Rings & Lids
Applicable Specification:
Overland Park Standard Details (Manhole Casting Detail) Overland Park Construction Specifications - Chapter 33 |
Manufacturer | Product Name or Number | Type | Approval Date | Comment | Catalog Cut Links |
Castings from overseas shall have the coupon as required in AASHTO M-306 for testing. | |||||
East Jordan Iron Works | 1502 A and Z | Heavy Duty | 4/11/2006 | 1502 | |
NACIP | N-207P | Heavy Duty | 4/11/2006 | N-207P | |
GCI Castings | SM 2206 OP | Heavy Duty | 4/28/2006 | SM 2206 OP | |
Deeter | 1320 | Heavy Duty | 4/28/2006 | 1320 | |
Clay and Bailey | 2007-01-6032/2007-01-6050 | Heavy Duty | 5/30/2007 | 2007 | |
Sigma | MH-207OP-35 | Heavy Duty | 2/17/2010 | 207OP-35 | |
East Jordan Iron Works | 1501 A and Z | Medium Duty | 4/11/2006 | 1501 | |
NACIP | N-220P | Medium Duty | 4/11/2006 | N-220P | |
GCI Castings | SM 2100 OP | Medium Duty | 4/28/2006 | SM 2100 OP | |
Deeter | 2016 | Medium Duty | 4/28/2006 | 2016 | |
Clay and Bailey | 2020-01-6032/2020-01-6050 | Medium Duty | 4/12/2007 | 2020 | |
Sigma | MH-202OP-35 | Medium Duty | 2/17/2010 | 202OP-35 |
Sealants - Manhole
Applicable Specification:
Johnson County Wastewater Standard Details |
Manufacturer | Product Name or Number | Approval Date | Comment | Catalog Cut Links |
Hamilton Kent | No. 2 (two ¾” beads) | 12/15/2005 | Kent Seal | |
Hamilton Kent | No. 2 (one 1” bead) | 12/15/2005 | Kent Seal | |
NPC | Bidco – C56 Butyl | 12/15/2005 | C56 Butyl | |
Press-Seal Gasket Corp. | Pro-Stik | 12/15/2005 | Pro-Stik |
Sealants - Pipe/RCBs
Manufacturer | Product Name or Number | Approval Date | Comment | Catalog Cut Links |
Blackhawk | Mastic | 12/15/2005 | ||
Mar-Mac Manufacturing | Mac-Wrap | 12/15/2005 | Mac-Wrap |
Class III Concrete Pipe
Applicable Specification:
Overland Park Municipal Code 15.10 |
Manufacturer | Gaskets | Joint Design | Pipe Size | Approval Date | Catalog Cut Links |
Pre-Tech | TecSeal 135 | 15”-36” | 22-Jun-05 | ||
Hamilton Kent | |||||
Pre-Tech | TecSeal 185 | 42”–48” | 22-Jun-05 | ||
Hamilton Kent | |||||
Pre-Tech | TecSeal 185 | 54”–60” | 28-Jul-06 | ||
Hamilton Kent | |||||
Pre-Tech | Hamilton Kent | 72” | 26-Mar-09 | ||
Hydro-Conduit | CSR Delta Pipe Products | R-4 | 12”-96” | 2-May-05 | 560-101 |
(O-ring for R-4 joint design) | |||||
Hydro-Conduit | CSR Delta 15” PF ¾ DS 49.75 | Offset | *15”–60” | 2-May-05 | B100-CE-84 |
(offset joint gasket) | |||||
Cretex1 | Hamilton Kent | P3 | 30” | 22-May-01 | |
(Tylox SuperSeal single offset for P3 & P4) | |||||
Cretex2 | Hamilton Kent | P3 | 42” | 22-May-01 | 42-P3 |
(Tylox SuperSeal single offset for P3 & P4) | |||||
Cretex3 | Hamilton Kent | P4 | 12”-36” | 22-May-01 | 12-36 |
(Tylox SuperSeal single offset for P3 & P4) | |||||
Cretex | Pipe Gasket & Supply | CX4 | 12”-78” | 22-May-01 | |
(O-ring for CX3 & CX4) | |||||
Press-Seal Gasket Corp | |||||
(O-ring for CX3 & CX4) | |||||
Cretex | Pipe Gasket & Supply | CX4 | 12”-120” | 22-May-01 | |
(O-ring for CX3 & CX4) | |||||
Press-Seal Gasket Corp | |||||
(O-ring for CX3 & CX4) | |||||
Cretex | Pipe Gasket & Supply | CX3 | 42” | 22-May-01 | 42-CX3 |
(O-ring for CX3 & CX4) | |||||
Press-Seal Gasket Corp | |||||
(O-ring for CX3 & CX4) | |||||
Cretex | Pipe Gasket & Supply | CX3 | 48”-60” | 22-May-01 | |
(O-ring for CX3 & CX4) | |||||
Press-Seal Gasket Corp | |||||
(O-ring for CX3 & CX4) |
Note: *15" is Class IV |
Underdrains
Applicable Specification:
Overland Park Construction Specifications - Chapter 34 KDOT 822 and 1907 with modifications |
Manufacturer | Product Name or Number | Type | Approval Date | Comment | Catalog Cut Links |
Contech | A-2000 | H | 3/29/2017 | A-2000 | |
ADS | N-12 | T | 3/29/2017 | N-12 | |
ADS | T (Alt.) | 12/15/2005 | ** |