Approved Materials - Fiber Optics

From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation Jump to search
Return to Approved Materials
Side arrow 80x66.png

Contractor Submittal Forms

GeekNotesIcon.png Note: This document is provided as a benefit to contractors and suppliers who are bidding projects for the City of Overland Park. Only products identified on this list will be approved for installation on City construction projects. This list shall not be used as a substitute for catalog cuts or material approval. All material approvals shall be submitted on the approved City of Overland Park Contract Project Submittal form. The form is available at City Hall by contacting Bruce Wacker at (913) 895-6027. Failure to comply will be cause for rejection of materials until proper submittals are received. This list is updated periodically. The contractor or supplier shall contact the City of Overland Park to make sure that they have the most current list prior to bidding a project. Failure to do so shall not constitute a legitimate claim for change orders. Before accessing any links, the City recommends that the user delete browsing history to insure the latest catalog cut information is displayed correctly.


Cables

Ethernet Cable

Notes Manufacturer Catalog Number Approval Date Photos
Quiktron is a subsidiary
of Legrand
Legrand/Quiktron 541-110-006 (ft) 7/28/15

Fiber Optic Patch Cable

Notes Manufacturer Catalog Number Approval Date Photos
ICC ICFOJ3M302 7/15/08 Patch Cable
Major Custom Cables FXDSLCST-XM 8/7/09
Quiktron is a subsidiary
of Legrand
Legrand/Quiktron L1-0203B3JY20002M Q-Series LC-ST 7/28/15 Patch Cable
LC Connector
ST Connector
Comment:
ST-LC connectors, 6' duplex, single mode
Connection from ITS Termination Drop Cable to Ethernet Switch

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Fiber Optic Plenum Cable

Notes Manufacturer Catalog Number Approval Date Photos
Belden Tight-Bufferred Aluminum Interlocked Armor Plenum Cable Nomenclature
FISD096AK - 96-Ct
FISD072AK - 72-Ct
FISD024A9 - 24-Ct
FISD012A9 - 12-Ct
11/17/21
Corning Cable Systems Tight-Buffered Interlocking Armored Plenum Cable (36 - 144 Fiber) Nomenclature
096E88-T3131-A3 - 96-Ct
072E88-T3131-A3 - 72-Ct
Tight-Buffered Interlocking Armored Plenum Cable (2 - 24 Fiber) Nomenclature
024E88-33131-A3 - 24-Ct
012E88-33131-A3 - 12-Ct
6/1/20
Comment:
Single Mode Fiber

Fiber Optic Riser Cable

Notes Manufacturer Catalog Number Approval Date Photos
Belden Tight-Buffered Aluminum Interlocked Armor Riser Cable Nomenclature
FISD144FK - 144-Ct
FISD096FK - 96-Ct
FISD072FK - 72-Ct
FISD048FK - 48-Ct
FISD036FJ - 36-Ct
FISD024F9 - 24-Ct
FISD012F9 - 12-Ct
11/17/21
Corning Cable systems MIC Tight-Buffered, Interlocking Armored Riser Cable (36 - 144 Fiber) Nomenclature
144E81-T3131-A1 - 144-Ct
096E81-T3131-A1 - 96-Ct
072E81-T3131-A1 - 72-Ct
048E81-T3131-A1 - 48-Ct
036E81-T3131-A1 - 36-Ct

MIC Tight-Buffered, Interlocking Armored Riser Cable (2 - 24 Fiber) Nomenclature
024E81-33131-A1 - 24-Ct
012E81-33131-A1 - 12-Ct
6/1/20
Comment:
Single Mode Fiber

Loose Tube Fiber Optic Cable

Notes Manufacturer Catalog Number Approval Date Photos
Belden FSSL1446D – 144 Ct
FSSL0966D – 96 Ct
FSSL0726D – 72 Ct
FSSL0486D – 48 Ct
FSSL0366D – 36 Ct
FSSL0246D – 24 Ct
FSSL0126D – 12 Ct
12/29/22
Corning Cable Systems ALTOS All-Dielectric Gel-Free Cables Nomenclature
144ZUC-T4101D20 – 144 Count
096ZUC-T4101D20 – 96 Count
ALTOS All-Dielectric Gel-Free Cables w/ FastAccess Technology Nomenclature
072ZUC-T4F22D20 – 72 Count
048ZUC-T4F22D20 – 48 Count
036ZUC-T4F22D20 – 36 Count
024ZUC-T4F22D20 – 24 Count
012ZUC-T4F22D20 – 12 Count
2/25/2020
Comment:
Single Mode Fiber
Single Jacket, Single Armored Loose Tube Cable

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

#10 AWG System Tracer Wire

Notes Manufacturer Catalog Number Approval Date Photos
Cerowire Wire & Cable Co., Inc. 112-3801-03-X 5/5/03
Encore Wire LTD UL file # E123774 8/1/03
Republic Wire UL File E167613 5/8/23 Label Name
Label Cable Type
Label UL File
Southwire Red 5/5/03
Comment:
Red Insulation
Stranded copper #10 AWG THHN/THWN-2
600 volt

Closet Connector Housing

Notes Manufacturer Catalog Number Approval Date Photos
Corning Fiber Closet Connector Housing
CCH-01U
Cassette Pigtails
6-CT Cassette Pigtail: CCH-CS06-6C-P00RE
12-CT Dual Cassette Pigtail: CCH-CS12-59-P00RE
5/19/22
Comment:
Other equipment within the same family can also be used

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Conduit and Couplings

HDPE Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Blue Diamond Industries 3" - BDI314OR
2" - BDI214OR
3/9/23 3" Cond Line Code
2" Cond Line Code
End View
Dura-Line 3” – 3SDR135ORG
2” – 2SDR135ORG
3/28/13


Comment:
SDR13.5 all sizes
Orange color
Smooth solid wall
UV Stabilized

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

HDPE Couplings

Notes Manufacturer Catalog Number Approval Date Photos
American Polywater Bonduit Conduit Adhesive
Use with standard Sch 40 PVC Couplings
10/11/10

7/10/14
Cartridge
Equipment
Nozzle
Cabletec HDPE to HDPE Coupling
2” – AS 2.375
3” – AS 3.500
8/2/01 Coupling
Dura-Line HDPE to HDPE Coupling or HDPE to PVC Coupling
ShurLock II Couplings
2" - 20000123
3" - 20000173
7/10/14 Side View
Label
End View
Georg Fischer Central Plastics HDPE to HDPE Electrofusion Couplings
2” IPS 5760030
3” IPS 10000358
5/5/06 Side View
Top View

Expansion Couplings

Notes Manufacturer Catalog Number Approval Date Photos
Allied Tube & Conduit 1" - 789648
1 ½” - 789650
2" - 789651
3" - 789653
4" - 789655
5/2/14
Cantex 1” – 5144033
1 ½” – 5144035
2” – 5144036
3” – 5144038
4” – 5144040
5/5/03
Heritage Plastics 1” – 610276
1 ½” – 610278
2” – 610279
3” – 610281
4” – 610283
9/26/13
IPEX Electrical Inc. Size / Part Number / Product Code
1” / EJ20 / 077383
1 ½” / EJ30 / 077385
2” / EJ35 / 077386
3” / EJ45 / 077388
4” / EJ55 / 077390
9/26/13
Prime Conduit
Purchased Carlon
Prime Conduit 1” – EC2PC100
1 ½” – EC2PC150
2” – EC2PC200
3” – EC2PC300
4” – EC2PC400
9/26/13
Formerly Plastic Trends
Royal Pipe Systems
Royal Building Products 1” – E016100
1 ½” – E016150
2” – E016200
3” – E016300
4” – E016400
9/26/13
Thomas & Betts
Purchased Carlon
Thomas & Betts 1” – E945F
1 ½” – E945H
2” – E945J
3” – E945L
4” – E945N
5/26/09

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Repair Couplings

Notes Manufacturer Catalog Number Approval Date Photos
Conduit Repair Systems, Inc. Schedule 40 Split Conduit
P2F - 2"
P3F - 3"

Schedule 40 Split Couplings (Joining split conduit to split conduit)
RC2F - 2"
RC3F - 3"

Split Adapter Couplings (Joining Split Conduit to Standard Conduit)
C2F - 2"
C3F - 3"

Schedule 40 Split 45° Sweeps
S2F24H45 - 2" Horizontal 24" Radius
S2F24V45 - 2" Vertical 24" Radius
S3F24H45 - 3" Horizontal 24" Radius
S3F24V45 - 3" Vertical 24" Radius
S2F36H45 - 2" Horizontal 36" Radius
S2F36V45 - 2" Vertical 36" Radius
S3F36H45 - 3" Horizontal 36" Radius
S3F36V45 - 3" Vertical 36" Radius

Schedule 40 Split 90° Sweeps
S2F24H90 - 2" Horizontal 24" Radius
S2F24V90 - 2" Vertical 24" Radius
S3F24H90 - 3" Horizontal 24" Radius
S3F24V90 - 3" Vertical 24" Radius
S2F36H90 - 2" Horizontal 36" Radius
S2F36V90 - 2" Vertical 36" Radius
S3F36H90 - 3" Horizontal 36" Radius
S3F36V90 - 3" Vertical 36" Radius
7/17/23 Split Adapter Coupling
Split Adapter Coupling Center Stop
Split Adapter Coupling End View
Glued Split Adapter Coupling
Split Adapter Coupling Label
JCM Industries JCM 101 Series Universal Clamp Couplings
2”: 101-0238-X
3”: 101-0350-X
5/23/16 Label
Back View
Gasket
Iso View
Comment:
X = For JCM Repair Coupling: Width of the Clamp: 6", 7", 12", 15"
Used to repair damaged fiber optic conduit only at City discretion when it is not feasible to remove fiber cable and fusion splice conduit
Conduit Repair Systems, Inc. Split Adapter Coupling shall be used with Approved Adhesive (See Approved List under HDPE Couplings)

Locating Materials

Tracer Cable

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable Red - 410RD
UL File # E208489
5/20/16 Cable
Cerro Wire & Cable Co, Inc. Red – 112-380103
UL file # E15119
5/5/03
Encore Wire LTD UL file # E123774 8/1/03
Southwire UL file # E14656 8/21/03
United Copper Industries UL file # E194031-A 5/26/09 Cable
Jacket Label
Comment:
Stranded copper
THHN/THWN #10 AWG
Red Jacket Insulation

Ground Rods

Notes Manufacturer Catalog Number Approval Date Photos
Erico Inc. 615880 2/27/02
Galvan Industries 6258 12/20/13
Hubbell C615880 4/24/12
Thomas & Betts 6258 5/5/03
Comment:
5/8” x 8’-0” long
Copper clad steel core
UL listed

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Ground Rod Clamp

Notes Manufacturer Catalog Number Approval Date Photos
Burndy GRC58 – 5/8” 2/27/02 Clamp
Erico Inc. HDC58 – 5/8” 12/1/05
Galvan Industries SRC – 5/8” 12/20/13
Thomas & Betts JAB58H – 5/8” 5/5/03
Comment:
Hex head set screw
Copper alloy
Long bearing surface
UL listed

Service Boxes

Type 1 Fiber Optic Service Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001974PCX24 - Box only
A6001975T - Cover only
A6001974TAPCX24 - Assembly
7/30/01 End View
Top View
Bottom View
Channell Commercial Corp BULKU243624F061011 - Assembly
BULKUA2436E061011 - Cover only
BULKUA2436240 - Box only
8/5/16 Cover Ground Wire
J&H APC243624 - Assembly 5/2/2024 Side View 1
Side View 2
Top View
Angle
New Basis Cover Label
PCB24362400000 – Box only
PCC2436P1-90042 – Cover only
PCA243624-00078 - Assembly
2/26/02
Oldcastle 24362214 - Body Only
24364609 - Lid Only
24361614 - Unit
8/29/13
Quazite was purchased
by Hubbell Power Systems
Quazite PG2436BA24 – Box only
PG2436HA0021 – Cover only
PG2436Z50221 - Assembly
Cover Codes
5/05/03 Side View
End View
Top View
Bolt Hole
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Cover Logo to read “Fiber Optics”
1 piece Cover to be 3” thick
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Type 2 Fiber Optic Service Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001430PCX24 - Box only
A6001470T (2 pc. Req.) - Cover only
A6001430TAPCX24 - Assembly
7/30/01 Side View
End View
Channell Commercial Corp BULKU304824F081011 - Assembly
BULKUA3048E081011 - Cover only
BULKUA3048240 - Box only
8/5/16 Cover Ground Wire
J&H APC304836 - Assembly 5/2/2024 Side View 1
Side View 2
Top View
Angle
New Basis Cover Label
PCB304824-00000 – Box only
PCC3048P2-90038 – Cover only
PCA304824-00158 - Assembly
2/26/02 Side View
Oldcastle 30482021 - Body Only
30484607 - Lid Only
8/29/13
Quazite was purchased
Hubbell Power Systems
Quazite PG3048BA24 – Box only
PG3048HS0021 – Cover only
PG3048Z52521 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Cover Logo to read “Fiber Optics”
2 Piece cover to be 3” thick underlapping
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Splice Enclosures

Notes Manufacturer Catalog Number Approval Date Photos
Corning Cable Systems Splicing from Signal Cabinet:
SCF-6C22-01-F
Trunk Line Splicing:
SCF-8C28-01-F
7/26/05 Cover
End View
Cable Tray
Tyco Electronics Corporation Spicing from Signal Cabinet:
FOSC 450-B6-6-12-1B0V
Trunk Line Splicing:
FOSC 450-D6-6-72-1D0V
10/12/05
Comment:
Bell Type Enclosures

Termination Drop Cable Assemblies

Notes Manufacturer Catalog Number Approval Date Photos
Corning Corning OptiTip
Integrated Panel Housing:
SPH-12OTR-126TH
Cable Harness:
00M112EB4D1EXXXF-P
5/11/20 Panel Housing
Cable Harness
Cable Harness Connector
Connection
Comment:
12 CT Cable
XXX = Cable Harness Length, must be in 10' or 25' increments

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Terminal Servers

Notes Manufacturer Catalog Number Approval Date Photos
Comtrol Network Enabling Devices DeviceMaster RTS 1-Port
Part Number 99435-0
9/1/05 Top View
Back View
Ethernet Port
Serial Port
Power Cable Port
Comment:
Single Port
Supply with 6’ CAT 5e Network Patch Cable


Return to Approved Materials