Difference between revisions of "Approved Materials - Traffic Signals"

From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation Jump to search
(441 intermediate revisions by 4 users not shown)
Line 1: Line 1:
[[Preapproved Materials|<font size="4">Return to Complete Preapproved Materials Page</font>]]
{{Return to AML}}
[http://ppm.opkansas.org/wiki/index.php/Contractor_Submittal_Forms '''Contractor Submittal Forms''']
{{PQLDisclaimer}}


{{PQLDisclaimer}}


<u>{{PQL-CSF|TRF-PQL-TS-CSF.docx}}</u>
<div class="noautonum">__TOC__</div>
<div class="noautonum">__TOC__</div>
== Anchor Bolts ==
== Anchor Bolts ==
Line 17: Line 17:
|
|
|[http://www.jhbotts.com/ JH Botts]
|[http://www.jhbotts.com/ JH Botts]
|[[media:TRF PQL TS CAT JHBotts AnchorBoltsMastArmPoles.pdf|Anchor Bolt Detail<br>1 1/2" x 54" x 6":<br>4 1/2 UNC 2A x 10" (84" + 6") GALV 20"<br>1 3/4" x 84" x 6":<br>5 UNC 2A x 10" (84" + 6") GALV 20"<br>2" x 84" x 6":<br>4 1/2 UNC 2A x 10" (84" + 6") GALV 20"]]
|[[Media:TRF PQL TS CAT JHBotts AnchorBoltsMastArmPoles.pdf|Anchor Bolt Detail<br>1 1/2" x 54" x 6":<br>6 UNC 2A x 10" (54" + 6") GALV 20"<br>1 3/4" x 84" x 6":<br>5 UNC 2A x 10" (84" + 6") GALV 20"<br>2" x 84" x 6":<br>4 1/2 UNC 2A x 10" (84" + 6") GALV 20"]]
|[[media:TRF PQL TS MEM JHBotts AnchorBoltsMastArmPoles.pdf|1/21/15]]
|[[Media:TRF PQL TS MEM JHBotts AnchorBoltsMastArmPoles.pdf|1/21/15]]
|
|
|-
|-
|
|
|[http://www.millerberndmfg.com/ Millerbernd]
|[http://www.millerberndmfg.com/ Millerbernd]
|Use Column for "Part No. Bolt w/2 Nuts & 2 Flat Washers"<br>[[media:TRF PQL TS CAT Millerbernd AnchorBoltsMastArmPole Combined.pdf|1 1/2" x 54" x 6": 460A579-12DNFW<br>1 3/4" x 84" x 6": 460A579-4DNFW<br>2" x 84" x 6": 460A579-5DNFW]]
|Use Column for "Part No. Bolt w/2 Nuts & 2 Flat Washers"<br>[[Media:TRF PQL TS CAT Millerbernd AnchorBoltsMastArmPole Combined.pdf|1 1/2" x 54" x 6": 460A579-12DNFW<br>1 3/4" x 84" x 6": 460A579-4DNFW<br>2" x 84" x 6": 460A579-5DNFW]]
|[[media:TRF PQL TS MEM Millerbernd AnchorBoltsMastArmPoles.pdf|7/30/15]]
|[[Media:TRF PQL TS MEM Millerbernd AnchorBoltsMastArmPoles.pdf|7/30/15]]
|
|
|-
|-
|Madden Bolt Corp fabricates for Union Metal
|Madden Bolt Corp fabricates for Union Metal
|[http://www.unionmetal.com/products/trafficcontrol.asp Union Metal]
|[http://www.unionmetal.com/products/trafficcontrol.asp Union Metal]
|[[media:TRF PQL TS CAT UnionMetal AnchorBoltsMastArmPoles.pdf|1 1/2" x 54" x 6": 311657<br>1 3/4" x 84" x 6": 311658<br>2" x 84" x 6": 311659]]
|[[Media:TRF PQL TS CAT UnionMetal AnchorBoltsMastArmPoles.pdf|1 1/2" x 54" x 6": 311657<br>1 3/4" x 84" x 6": 311658<br>2" x 84" x 6": 311659]]
|[[media:TRF PQL TS MEM UnionMetal AnchorBoltsMastArmPoles.pdf|7/5/16]]
|[[Media:TRF PQL TS MEM UnionMetal AnchorBoltsMastArmPoles.pdf|7/5/16]]
|
|
|-
|-
Line 47: Line 47:
|
|
|[http://componentproducts.com/ Component Products, Inc]
|[http://componentproducts.com/ Component Products, Inc]
|[[media:TRF PQL TS CAT ComponentProducts PedestalPoleAnchorBolt.pdf|Anchor Bolts: CPI-AB-18]]
|[[Media:TRF PQL TS CAT ComponentProducts PedestalPoleAnchorBolt.pdf|CPI-AB-18]]
|[[media:TRF PQL TS MEM ComponentProducts PedestalPoleAnchorBolt.pdf|4/24/14]]
|[[Media:TRF PQL TS MEM ComponentProducts PedestalPoleAnchorBolt.pdf|4/24/14]]
|
|
|-
|-
|
|
|[http://www.gadestraffic.com/ Gades Sales]
|[http://www.gadestraffic.com/ Gades Sales]
|[[media:TRF PQL TS CAT GadesSales PedestalPoleAnchorBolts.pdf|Anchor Bolts: PB-5518-GLV]]
|[[Media:TRF PQL TS CAT GadesSales PedestalPoleAnchorBolts.pdf|PB-5518-GLV]]
|[[media:TRF PQL TS MEM GadesSales PedestalPoleAnchorBolts.pdf|4/24/14]]
|[[Media:TRF PQL TS MEM GadesSales PedestalPoleAnchorBolts.pdf|4/24/14]]
|
|-
|
|[https://www.jhbotts.com/ JH Botts]
|[[Media:TRF PQL TS CAT JHBotts AnchorBoltsMastArmPoles.pdf|.750"-10 UNC 2A x 6" (17" + 3") GALV 20"]]
|[[Media:TRF PQL TS MEM JHBotts AnchorBoltsMastArmPoles.pdf|1/21/15]]
|
|
|-
|-
|
|
|[http://www.pelcoinc.com/ Pelco Products, Inc.]
|[http://www.pelcoinc.com/ Pelco Products, Inc.]
|[[media:TRF PQL TS CAT Pelco PedestalPoleAnchorBolts.pdf|Anchor Bolts: PB-5518-GLV]]
|[[Media:TRF PQL TS CAT Pelco PedestalPoleAnchorBolts.pdf|PB-5518-GLV]]
|[[media:TRF PQL TS MEM PelcoProducts PedestalPoleAnchorBolts.pdf|4/23/14]]
|[[Media:TRF PQL TS MEM PelcoProducts PedestalPoleAnchorBolts.pdf|4/23/14]]
|
|
|}
|}
{{PQLNote|ASTM F1554 GR36 A<br>Threads shall be rolled<br>18" Length}}
{{PQLNote|ASTM A36, Gr 50 or Gr 55<br>Threads shall be rolled<br>17" - 18" Length}}


{{PQLReturn}}
{{PQLReturn}}


== Backplates (Vehicular) ==
== Backplates (Vehicular) ==
=== Standard Vehicular Backplates ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 78: Line 85:
|
|
|[https://www.gadestraffic.com/ Gades Sales / Neodesha Plastics]
|[https://www.gadestraffic.com/ Gades Sales / Neodesha Plastics]
|[[media:TRF PQL TS CAT Gades Backplates.pdf|BP481PO – 1 section<br>BP483PO – 3 section<br>BP484PO – 4 section<br>BP485PO – 5 section]]
|[[Media:TRF PQL TS CAT Gades Backplates.pdf|BP481PO – 1 section<br>BP483PO – 3 section<br>BP484PO – 4 section<br>BP485PO – 5 section]]
|[[media:TRF PQL TS MEM Gades Backplates.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Gades Backplates.pdf|5/5/03]]
|
|
|-
|-
|
|
|[https://www.midamsignal.com/ Mid American Signal]
|[https://www.midamsignal.com/ Mid American Signal]
|<u>For Econolite Signal Heads</u><br>[[media:TRF PQL TS CAT MidAmericaSignal Backplates.pdf|MI-1003-L2 – 3 section]]<br><u>For McCain Signal Heads</u><br>[[media:TRF PQL TS CAT MidAmericaSignal Backplates.pdf|MI-1003-N – 3 section]]
|<u>For Econolite or North American Signal Heads</u><br>[[Media:TRF PQL TS CAT MidAmericaSignal Backplates.pdf|MI-1003-L2 – 3 section]]<br><u>For McCain Signal Heads</u><br>[[Media:TRF PQL TS CAT MidAmericaSignal Backplates.pdf|MI-1003-N – 3 section]]
|[[media:TRF PQL TS MEM MidAmericaSignal Backplates.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM MidAmericaSignal Backplates.pdf|5/5/03]]
|
|-
|
|[https://www.mobotrexmanufacturing.com/products/ Mobotrex / Eagle]
|<u>For Mobotrex / Eagle Signal Heads</u><br>[[Media:TRF PQL TS CAT MobotrexEagle Backplates.pdf|BVD501ANFXX0N0-00 – 1 section<br>BVD503ANFXX0N0-00 – 3 section<br>BVD504ANFXX0N0-00 – 4 section<br>Where XX = 02 for AstroBracket and 05 for SkyBracket<br>BVD503TNF050N0-00 – HAWK]]
|[[Media:TRF PQL TS MEM MobotrexEagle Backplates.pdf|3/25/19]]
|
|
|-
|-
|
|
|[http://www.pelcoinc.com/ Pelco Products, Inc.]
|[http://www.pelcoinc.com/ Pelco Products, Inc.]
|<u>For Econolite Signal Heads</u><br>[[media:TRF PQL TS CAT Pelco Backplates.pdf|BK-1001-L3 – 1 section<br>BK-1003-L3 – 3 section<br>BK-1004-L3 – 4 section<br>BK-1005-L3 – 5 section]]<br>[[media:TRF PQL TS CAT Pelco HAWKBackplates.pdf|BK-2032-L3 - HAWK]]<br><br><u>For McCain Signal Heads</u><br>[[media:TRF PQL TS CAT Pelco Backplates.pdf|BK-1001-N – 1 section<br>BK-1003-N – 3 section<br>BK-1004-N – 4 section<br>BK-1005-N – 5 section ]]<br>[[media:TRF PQL TS CAT Pelco HAWKBackplates.pdf|BK-2032-N - HAWK]]
|<u>For Econolite or North American Signal Heads</u><br>[[Media:TRF PQL TS CAT Pelco Backplates.pdf|BK-1001-L3 – 1 section<br>BK-1003-L3 – 3 section<br>BK-1004-L3 – 4 section<br>BK-1005-L3 – 5 section]]<br>[[Media:TRF PQL TS CAT Pelco HAWKBackplates.pdf|BK-2032-L3 - HAWK]]<br><br><u>For McCain Signal Heads</u><br>[[Media:TRF PQL TS CAT Pelco Backplates.pdf|BK-1001-N – 1 section<br>BK-1003-N – 3 section<br>BK-1004-N – 4 section<br>BK-1005-N – 5 section]] <br>[[Media:TRF PQL TS CAT Pelco HAWKBackplates.pdf|BK-2032-N - HAWK]]
|[[media:TRF PQL TS MEM Pelco Backplates.pdf|5/5/03]]  
|[[Media:TRF PQL TS MEM Pelco Backplates.pdf|5/5/03]]
|
|
|-
|}
|}
{{PQLNote|0.125” thick<br>12” Signal Head Sections}}
{{PQLNote|0.125” thick<br>12” Signal Head Sections}}
=== Flexible Vehicular Backplates ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|<font color="red">'''For Maintenance Use Only'''</font>
|[https://www.pelcoinc.com/ Pelco Products Inc.]
|<u>Universal AeroFlex Options</u><br>[[Media:TRF PQL TS CAT Pelco UniversalFlexibleBackplate.pdf|'''Standard'''<br>BK-8000-3-PNC - 3 Section<br>BK-8000-4-PNC - 4 Section<br>'''With Fluorescent Border'''<br>BK-8000-3-RT2-PNC - 3 Section<br>BK-8000-4-RT2-PNC -  4 Section]]<br><br><u>Eagle DuraSig-Specific Poly AeroFlex Options</u><br>[[Media:TRF PQL TS CAT Pelco EagleFlexibleBackplate.pdf|'''Standard'''<br>BK-8100-3-EagleSG-PNC - 3 Section<br>BK-8100-4-EagleSG-PNC - 4 Section<br>'''With Fluorescent Border'''<br>BK-8100-3-EagleSG-RT2-PNC - 3 Section<br>BK-8100-4-EagleSG-RT2-PNC -  4 Section]]<br><br><u>McCain Specific Poly AeroFlex Options</u><br>[[Media:TRF PQL TS CAT Pelco McCainFlexibleBackplate.pdf|'''Standard'''<br>BK-8100-3-McCain-PNC - 3 Section<br>BK-8100-4-McCain-PNC - 4 Section<br>'''With Fluorescent Border'''<br>BK-8100-3-McCain-RT2-PNC - 3 Section<br>BK-8100-4-McCain-RT2-PNC -  4 Section]]<br>
|[[Media:TRF PQL TS MEM Pelco FlexibleBackplates.pdf|8/2/19]]
|[[Media:TRF PQL TS PHOT Pelco FlexibleBackplates Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Pelco FlexibleBackplates Back.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT Pelco FlexibleBackplates Connection.JPG|Connection]]
|-
|}
{{PQLNote|Universal backplates will fit McCain 12" Poly, Econolite 12" Poly, TCT/Peek 12" Poly}}


{{PQLReturn}}
{{PQLReturn}}
Line 111: Line 143:
|
|
|[https://adcable.com/products/imsa-traffic.html Advanced Digital Cable]
|[https://adcable.com/products/imsa-traffic.html Advanced Digital Cable]
|8103/3C14B7119-1
|[[Media:TRF PQL TS CAT AdvancedDigitalCable Power&MonitoringCable.pdf|8103]]
|[[media:TRF PQL TS MEM AdvancedDigitalCable Power&MonitoringCable.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM AdvancedDigitalCable Power&MonitoringCable.pdf|5/5/03]]
|
|
|-
|-
|
|
|[http://www.falconfinewire.com/ Falcon Fine Wire]
|[http://www.falconfinewire.com/ Falcon Fine Wire]
|980314X19-1-00
|[[Media:TRF PQL TS CAT FalconFineWire Power&MonitoringCable.pdf|980314X19-1]]
|[[media:TRF PQL TS MEM FalconFineWire Power&MonitoringCable.pdf|4/24/08]]
|[[Media:TRF PQL TS MEM FalconFineWire Power&MonitoringCable.pdf|4/24/08]]
|
|[[Media:TRF PQL TS PHOT FalconFineWire Power&MonitoringCable Label.JPG|Label]]<br>[[Media:TRF PQL TS PHOT FalconFineWire Power&MonitoringCable Cable.JPG|Cable]]
|}
|}
{{PQLNote|1-3c#14 IMSA 19-1}}
{{PQLNote|1-3c#14 IMSA 19-1}}
Line 134: Line 166:
|
|
|[http://adcable.com/products/industrial-wire-cable.html Advanced Digital Cable]
|[http://adcable.com/products/industrial-wire-cable.html Advanced Digital Cable]
|[[media:TRF PQL TS CAT AdvancedDigitalCable CNGPowerCable.pdf|302]]<br>UL File # E197262
|[[Media:TRF PQL TS CAT AdvancedDigitalCable CNGPowerCable.pdf|302]]<br>UL File # E197262
|[[media:TRF PQL TS MEM AdvancedDigitalCable CNGPowerCable.pdf|5/20/16]]
|[[Media:TRF PQL TS MEM AdvancedDigitalCable CNGPowerCable.pdf|5/20/16]]
|[[media:TRF PQL TS PHOT AdvancedDigitalCable CNGPowerCable.JPG|Cable]]<br>[[media:TRF PQL TS PHOT AdvancedDigitalCable CNGPowerCable Label.JPG|Label]]<br>[[media:TRF PQL TS PHOT AdvancedDigitalCable CNGPowerCable Label1.JPG|E File No.]]
|[[Media:TRF PQL TS PHOT AdvancedDigitalCable CNGPowerCable.JPG|Cable]]<br>[[Media:TRF PQL TS PHOT AdvancedDigitalCable CNGPowerCable Label.JPG|Label]]<br>[[Media:TRF PQL TS PHOT AdvancedDigitalCable CNGPowerCable Label1.JPG|E File No.]]
|-
 
|Acquired by Southwire
|[https://www.iewc.com/brands/coleman-cable Coleman  Cable Inc.]
|[[Media:TRF PQL TS CAT ColemanCable CNGPowerCable.pdf|41112 MTW  Cable]]
|[[Media:TRF PQL TS MEM ColemanCable CNGPowerCable.pdf|11/5/12]]
|[[Media:TRF PQL TS PHOT ColemanCable CNGPowerCable Cable.jpg|Cable]]
|-
|-
|
|[https://www.servicewire.com/ Service Wire Co]
|USE2BK
|5/7/02
|
|
|[https://www.ccixpress.com/webapp/wcs/stores/servlet/ProductDisplay?catalogId=10101&storeId=10051&productId=114609&langId=-1&channel=%24&bu=%24%24&customer=&parent_category_rn=10924 Coleman  Cable Inc.]
|[[media:TRF PQL TS CAT ColemanCable CNGPowerCable.pdf|41112 MTW  Cable]]
|[[media:TRF PQL TS MEM ColemanCable CNGPowerCable.pdf|11/5/12]]
|[[media:TRF PQL TS PHOT ColemanCable CNGPowerCable Cable.jpg|Cable]]
|-
|-
|
|
|[https://www.southwire.com/ Southwire]
|[https://www.southwire.com/ Southwire]
Line 150: Line 191:
|
|
|-
|-
|
|Service Wire Co
|XLP-USE-2-STR-BLK
|
|
|}
|}
{{PQLNote|600 Volt Copper soft drawn stranded copper #2 AWG}}
{{PQLNote|600 Volt Copper soft drawn stranded copper #2 AWG}}
Line 169: Line 205:
|
|
|[http://adcable.com/products/industrial-wire-cable.html Advanced Diital Cable]
|[http://adcable.com/products/industrial-wire-cable.html Advanced Diital Cable]
|[[media:TRF PQL TS CAT AdvancedDigitalCable ElectricalServiceCable.pdf|304]]<br>UL file # E197262
|[[Media:TRF PQL TS CAT AdvancedDigitalCable ElectricalServiceCable.pdf|304]]<br>UL file # E197262
|[[media:TRF PQL TS MEM AdvancedDigitalCable ElectricalServiceCable.pdf|5/20/16]]
|[[Media:TRF PQL TS MEM AdvancedDigitalCable ElectricalServiceCable.pdf|5/20/16]]
|[[media:TRF PQL TS PHOT AdvancedDigitalCable ElectricalServiceCable Label.JPG|Mfg Label]]<br>[[media:TRF PQL TS PHOT AdvancedDigitalCable ElectricalServiceCable Label1.JPG|AWG Label]]<br>[[media:TRF PQL TS PHOT AdvancedDigitalCable ElectricalServiceCable.JPG|Cable]]
|[[Media:TRF PQL TS PHOT AdvancedDigitalCable ElectricalServiceCable Label.JPG|Mfg Label]]<br>[[Media:TRF PQL TS PHOT AdvancedDigitalCable ElectricalServiceCable Label1.JPG|AWG Label]]<br>[[Media:TRF PQL TS PHOT AdvancedDigitalCable ElectricalServiceCable.JPG|Cable]]
|-
|-
|
|
|[https://www.alanwire.com/ Alan Wire]
|[https://www.alanwire.com/ Alan Wire]
|[[media:TRF PQL TS CAT AlanWire SignalServiceCable.pdf|04USE11 – 500’]]<br>UL file #E319493
|[[Media:TRF PQL TS CAT AlanWire SignalServiceCable.pdf|04USE11 – 500’]]<br>UL file #E319493
|[[media:TRF PQL TS MEM AlanWire ElectricalServiceWireCable.pdf|1/30/12]]
|[[Media:TRF PQL TS MEM AlanWire ElectricalServiceWireCable.pdf|1/30/12]]
|[[media:TRF PQL TS PHOT AlanWire SignalServiceCable Cable.JPG|Cable]]<br>[[media:TRF PQL TS PHOT AlanWire SignalServiceCable Efile.JPG|E-File]]<br>[[media:TRF PQL TS PHOT AlanWire SignalServiceCable Label.JPG|Label]]
|[[Media:TRF PQL TS PHOT AlanWire SignalServiceCable Cable.JPG|Cable]]<br>[[Media:TRF PQL TS PHOT AlanWire SignalServiceCable Efile.JPG|E-File]]<br>[[Media:TRF PQL TS PHOT AlanWire SignalServiceCable Label.JPG|Label]]
|-
|-
|Member of The Marmon Group of  Companies
|Member of The Marmon Group of  Companies
|[http://www.cerrowire.com/electrical-copper-use-2 Cerro Wire & Cable Co, Inc.]
|[https://www.cerrowire.com/ Cerro Wire & Cable Co, Inc.]
|[[media:TRF PQL TS CAT Cerro ElectricalServiceWireCable.pdf|1201-4401-Black<br>1201-4402 - White<br>1201-1105 - Green]]<br>UL file # E11098
|[[Media:TRF PQL TS CAT Cerro ElectricalServiceWireCable.pdf|1201-4401-Black<br>1201-4402 - White<br>1201-1105 - Green]]<br>UL file # E11098
|[[media:TRF PQL TS MEM Cerro ElectricalServiceWireCable.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Cerro ElectricalServiceWireCable.pdf|5/5/03]]
|
|
|-  
|-  
|
|Part of the Prysmian Group
|Draka Cableteq
|[https://na.prysmiangroup.com/ Draka]
|Product Number 388932
|[[Media:TRF PQL TS CAT Draka ElectricalServiceWireCable.pdf|388932]]
|[[media:TRF PQL TS MEM Draka ElectricalServiceWireCable.pdf|7/8/09]]
|[[Media:TRF PQL TS MEM Draka ElectricalServiceWireCable.pdf|7/8/09]]
|
|
|-  
|-  
|
|
|[http://www.encorewire.com/ Encore Wire LTD]
|[http://www.encorewire.com/ Encore Wire LTD]
|[[media:TRF PQL TS CAT Encore ElectricalServiceCable.pdf|UL file # E174428]]
|[[Media:TRF PQL TS CAT Encore ElectricalServiceCable.pdf|UL file # E174428]]
|[[media:TRF PQL TS MEM Encore ElectricalServiceCable.pdf|8/1/03]]
|[[Media:TRF PQL TS MEM Encore ElectricalServiceCable.pdf|8/1/03]]
|[[media:TRF PQL TS PHOT Encore ElectricalServiceCable Cable.jpg|Cable]]<br>[[media:TRF PQL TS PHOT Encore ElectricalServiceCable Efile.jpg|E-File]]
|[[Media:TRF PQL TS PHOT Encore ElectricalServiceCable Cable.jpg|Cable]]<br>[[Media:TRF PQL TS PHOT Encore ElectricalServiceCable Efile.jpg|E-File]]
|-  
|-  
|
|
|[http://www.kristechwire.com/ Kris Tech Wire Co, Inc.]
|[http://www.kristechwire.com/ Kris Tech Wire Co, Inc.]
|[[media:TRF PQL TS CAT Kris-TechCable ElectricalServiceCable.pdf|0407-RHW/USE-BK]]<br>UL file # E207249
|[[Media:TRF PQL TS CAT Kris-TechCable ElectricalServiceCable.pdf|0407-RHW/USE-BK]]<br>UL file # E207249
|[[media:TRF PQL TS MEM KrisTechWire ElectricalServiceWireCable.pdf|11/24/03]]
|[[Media:TRF PQL TS MEM KrisTechWire ElectricalServiceWireCable.pdf|11/24/03]]
|[[media:TRF PQL TS PHOT Kris-TechCable ElectricalServiceCable Cable.jpg|Cable]]<br>[[media:TRF PQL TS PHOT Kris-TechCable ElectricalServiceCable label.jpg|Label]]
|[[Media:TRF PQL TS PHOT Kris-TechCable ElectricalServiceCable Cable.jpg|Cable]]<br>[[Media:TRF PQL TS PHOT Kris-TechCable ElectricalServiceCable label.jpg|Label]]
|-  
|-  
|
|
|[http://www.servicewire.com/ServiceWire.htm Service Wire Co]
|[http://www.servicewire.com/ServiceWire.htm Service Wire Co]
|[[media:TRF PQL TS CAT ServiceWire ElectricalServiceCable.pdf|USEVW4BK]]<br>UL file # E105667
|[[Media:TRF PQL TS CAT ServiceWire ElectricalServiceCable.pdf|USEVW4BK]]<br>UL file # E105667
|[[media:TRF PQL TS MEM ServiceWire ElectricalServiceCable.pdf|5/7/02]]
|[[Media:TRF PQL TS MEM ServiceWire ElectricalServiceCable.pdf|5/7/02]]
|[[media:TRF PQL TS ServiceWire DistributionCable Cable.JPG|Cable]]<br>[[media:TRF PQL TS ServiceWire DistributionCable Label.JPG|Label]]
|[[Media:TRF PQL TS ServiceWire DistributionCable Cable.JPG|Cable]]<br>[[Media:TRF PQL TS ServiceWire DistributionCable Label.JPG|Label]]
|-
|-
|
|
|[http://www.southwire.com/ Southwire Co]
|[http://www.southwire.com/ Southwire Co]
|[[media:TRF PQL TS CAT Southwire ElectricalServiceCable.pdf|113472 – Black<br>476565 – White<br>952663 - Green]]<br>UL file # E32071
|[[Media:TRF PQL TS CAT Southwire ElectricalServiceCable.pdf|113472 – Black<br>476565 – White<br>952663 - Green]]<br>UL file # E32071
|[[media:TRF PQL TS MEM Southwire ElectricalServiceCable.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Southwire ElectricalServiceCable.pdf|5/5/03]]
|  
|  
|-
|-
Line 229: Line 265:
|
|
|[http://www.belden.com/products/ Belden]
|[http://www.belden.com/products/ Belden]
|[[media:TRF PQL TS CAT Belden EVPDetectorCable.pdf|580461]]
|[[Media:TRF PQL TS CAT Belden EVPDetectorCable.pdf|580461]]
|[[media:TRF PQL TS MEM Belden EVPDetectorCable.pdf|11/7/05]]
|[[Media:TRF PQL TS MEM Belden EVPDetectorCable.pdf|11/7/05]]
|[[media:TRF PQL TS PHOT Belden EVPDetectorCable.jpg|Cable]]
|[[Media:TRF PQL TS PHOT Belden EVPDetectorCable.jpg|Cable]]
|-
|-
|
|
|[http://www.gtt.com/ Global Traffic Technologies]
|[http://www.gtt.com/ Global Traffic Technologies]
|[[media:TRF PQL TS CAT GTT EVPDetectorCable.pdf|Model 138]]
|[[Media:TRF PQL TS CAT GTT EVPDetectorCable.pdf|Model 138]]
|[[media:TRF-PQL TS MEM GTT EVPDetectorCable.pdf|3/24/08]]
|[[Media:TRF-PQL TS MEM GTT EVPDetectorCable.pdf|3/24/08]]
|[[media:TRF-PQL TS PHOT GTT EVPDetectorCable.jpg|Cable]]
|[[Media:TRF-PQL TS PHOT GTT EVPDetectorCable.jpg|Cable]]
|}
|}


Line 251: Line 287:
|
|
|[http://www.advanceddigitalcable.com/detection-notification/tube-loop-detector.html?highlight=WyJpbXNhIiwiNTEtNSIsImltc2EgNTEtNSJd Advanced Digital Cable]
|[http://www.advanceddigitalcable.com/detection-notification/tube-loop-detector.html?highlight=WyJpbXNhIiwiNTEtNSIsImltc2EgNTEtNSJd Advanced Digital Cable]
|[[media:TRF PQL TS CAT AdvancedDigitalCable InductionLoopCable.pdf|8450]]
|[[Media:TRF PQL TS CAT AdvancedDigitalCable InductionLoopCable.pdf|8450]]
|[[media:TRF PQL TS MEM AdvancedDigitalCable InductionLoopCable.pdf|6/29/09]]
|[[Media:TRF PQL TS MEM AdvancedDigitalCable InductionLoopCable.pdf|6/29/09]]
|
|
|-  
|-  
|
|
|[http://www.belden.com/docs/upload/IMSA-Catalog-IMSA-Cat.pdf Belden]
|[http://www.belden.com/docs/upload/IMSA-Catalog-IMSA-Cat.pdf Belden]
|[[media:TRF PQL TS CAT Belden InductionLoopCable.pdf|580206]]
|[[Media:TRF PQL TS CAT Belden InductionLoopCable.pdf|580206]]
|6/17/03
|6/17/03
|
|
|-
|-
|Supplier
|Clifford of Vermont
|1C14B19LOOP
|[[media:TRF PQL TS MEM CliffordofVT InductionLoopCable.pdf|5/5/03]]
|
|-
|
|
|[http://www.falconfinewire.com/#!__products/vstc3=51-5-&-51-7 Falcon Fine Wire]
|[http://www.falconfinewire.com/#!__products/vstc3=51-5-&-51-7 Falcon Fine Wire]
|[[media:TRF PQL TS CAT FalconFineWire InductionLoopCable.pdf|14-1 IMSA 51-5]]
|[[Media:TRF PQL TS CAT FalconFineWire InductionLoopCable.pdf|14-1 IMSA 51-5]]
|[[media:TRF PQL TS MEM FalconFineWire InductionLoopCable.pdf|4/20/01]]
|[[Media:TRF PQL TS MEM FalconFineWire InductionLoopCable.pdf|4/20/01]]
|
|
|-
|-
|  
|  
|[http://www.jamesmonroewire.com/imsa.html James Monroe Wire and Cable Corporation]
|[http://www.jamesmonroewire.com/ James Monroe Wire and Cable Corporation]
|[[media:TRF PQL TS CAT JamesMonroeWire InductionLoopCable.pdf|IMSA 51-5]]
|[[Media:TRF PQL TS CAT JamesMonroeWire InductionLoopCable.pdf|IMSA 51-5]]
|[[media:TRF PQL TS MEM JamesMonroeWire InductionLoopCable.pdf|9/1/99]]
|[[Media:TRF PQL TS MEM JamesMonroeWire InductionLoopCable.pdf|9/1/99]]
|
|-
|
|[http://www.kristechwire.com/traffic-loop-cable.php Kris-Tech]
|1419-THHN-TUBE-PVC-BLACK
|[[media:TRF PQL TS MEM KrisTech InductionLoopCable.pdf|2/1/01]]
|
|
|}
|}
{{PQLNote|IMSA Type 51-5 Tube Loop Detector Cable<br>PVC/nylon Insulated cable<br>PVC Tube<br>600 Volt}}
{{PQLNote|IMSA Type 51-5 Tube Loop Detector Cable<br>PVC/nylon Insulated cable<br>PVC Tube<br>600 Volt}}


=== Multi-conductor 7c#14 and 2c#14 ===
=== Multi-conductor 7c#14 and 2c#14 ===
Line 299: Line 323:
|
|
|[http://www.advanceddigitalcable.com/signal/imsa-19-1-stranded.html Advanced Digital Cable / Clifford of Vermont]
|[http://www.advanceddigitalcable.com/signal/imsa-19-1-stranded.html Advanced Digital Cable / Clifford of Vermont]
|[[media:TRF PQL TS CAT AvancedDigitalCable MultiConductorSignalCable.pdf|7c – 8107 / 7C14B7I19-1<br>2c – 8102 / 2C14B7I19-1]]
|[[Media:TRF PQL TS CAT AvancedDigitalCable MultiConductorSignalCable.pdf|7c – 8107 / 7C14B7I19-1<br>2c – 8102 / 2C14B7I19-1]]
|[[media:TRF PQL TS MEM CliffardofVT MultiConductorSignalCable.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM CliffardofVT MultiConductorSignalCable.pdf|5/5/03]]
|[[media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 2Conductor.JPG|2 Condctor Cable]]<br>[[media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 7Conductor.JPG|7 Conductor Cable]]<br>[[media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 7CMylarWrap.JPG|Mylar Wrap]]<br>[[media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 7CLabel.JPG|Label]]
|[[Media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 2Conductor.JPG|2 Condctor Cable]]<br>[[Media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 7Conductor.JPG|7 Conductor Cable]]<br>[[Media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 7CMylarWrap.JPG|Mylar Wrap]]<br>[[Media:TRF PQL TS PHOT AvancedDigitalCable MultiConductorSignalCable 7CLabel.JPG|Label]]
|-
|
|[http://www.belden.com/docs/upload/IMSA-Catalog-IMSA-Cat.pdf Belden]
|[[media:TRF PQL TS CAT Belden MultiConductorSignalCable.pdf|7c – 601205]]<br>[[media:TRF PQL TS CAT Belden MultiConductorSignalCable2C.pdf|2c – 601457]]
|[[media:TRF PQL TS MEM Belden MultiConductorSignalCable.pdf|2/1/01]]
|
|-
|-
|
|Not a standard product<br>but they will produce
|[http://www.colemancable.com/Products/New-Products/New-Products-Distribution-OEM Coleman Cable Inc.]
|[https://www.belden.com/ Belden]
|[[media:TRF PQL TS CAT ColemanCable MultiConductorSignalCable.pdf|7c – 559107<br>2c - 559102]]
|[[Media:TRF PQL TS CAT Belden MultiConductorSignalCable7c.pdf|7c – 601205]]<br>[[Media:TRF PQL TS CAT Belden MultiConductorSignalCable2c.pdf|2c – 601457]]
|[[media:TRF PQL TS MEM ColemanCable MultiConductorSignalCable.pdf|1/10/12]]
|[[Media:TRF PQL TS MEM Belden MultiConductorSignalCable.pdf|2/1/01]]
|
|[[Media:TRF PQL TS PHOT Belden MultiConductorSignalCable7c Label.JPG|Label]]<br>[[Media:TRF PQL TS PHOT Belden MultiConductorSignalCable7c Cable.JPG|Cable]]
|-
|-
|
|
|[http://www.falconfinewire.com/#!__products/vstc3=19-1-14awg Falcon Fine Wire]
|[http://www.falconfinewire.com/#!__products/vstc3=19-1-14awg Falcon Fine Wire]
|[[media:TRF PQL TS CAT FalconFineWire MultiConductorSignalCable.pdf|7c – 980714X19-1-00<br>2c – 980214X19-1-00]]
|[[Media:TRF PQL TS CAT FalconFineWire MultiConductorSignalCable.pdf|7c – 980714X19-1-00<br>2c – 980214X19-1-00]]
|[[media:TRF PQL TS MEM FalconFineWire MultiConductorSignalCable.pdf|5/23/05]]
|[[Media:TRF PQL TS MEM FalconFineWire MultiConductorSignalCable.pdf|5/23/05]]
|
|[[Media:TRF PQL TS PHOT FalconFineWire MultiConductorSignalCable 7cLabel.jpg|7c Label]]<br>[[Media:TRF PQL TS PHOT FalconFineWire MultiConductorSignalCable 7cMylarWrap.jpg|7c Mylar Wrap]]<br>[[Media:TRF PQL TS PHOT FalconFineWire MultiConductorSignalCable 7cCable.JPG|7c Cable]]<br>[[Media:TRF PQL TS PHOT FalconFineWire MultiConductorSignalCable 2cLabel.jpg|2c Label]]<br>[[Media:TRF PQL TS PHOT FalconFineWire MultiConductorSignalCable 2cMylarWrap.jpg|2c Mylar Wrap]]<br>[[Media:TRF PQL TS PHOT FalconFineWire MultiConductorSignalCable 2cCable.jpg|2c Cable]]
|-
|-
|
|
|[http://www.jamesmonroewire.com/imsa.html James Monroe Wire and Cable Corporation]
|[http://www.jamesmonroewire.com/ James Monroe Wire and Cable Corporation]
|[[media:TRF PQL TS CAT JamesMonroeSignalCable MultiConductorSignalCable.pdf|7c – IMSA 19-1<br>2c – IMSA 19-1]]
|[[Media:TRF PQL TS CAT JamesMonroeSignalCable MultiConductorSignalCable.pdf|7c – IMSA 19-1<br>2c – IMSA 19-1]]
|[[media:TRF PQL TS MEM JamesMonroeSignalCable MultiConductorSignalCable.pdf|9/1/99]]
|[[Media:TRF PQL TS MEM JamesMonroeSignalCable MultiConductorSignalCable.pdf|9/1/99]]
|
|
|}
|}
{{PQLNote|IMSA 19-1<br>600 Volt<br>Stranded Copper<br>#14 AWG}}
{{PQLNote|IMSA 19-1<br>600 Volt<br>Stranded Copper<br>#14 AWG}}


=== Micro loop Home Run ===
=== Micro loop Home Run ===
Line 341: Line 358:
|Global Traffic Technologies bought out 3M
|Global Traffic Technologies bought out 3M
|[http://www.gtt.com/canoga-traffic-sensing/ Global Traffic Technologies]
|[http://www.gtt.com/canoga-traffic-sensing/ Global Traffic Technologies]
|[[media:TRF PQL TS CAT 3M MicroLoopDetectorLeadInCable.pdf|Model Canoga 30003]]
|[[Media:TRF PQL TS CAT 3M MicroLoopDetectorLeadInCable.pdf|Model Canoga 30003]]
|[[media:TRF PQL TS MEM 3M MicroLoopDetectorLeadInCable.pdf|5/20/03]]
|[[Media:TRF PQL TS MEM 3M MicroLoopDetectorLeadInCable.pdf|5/20/03]]
|
|
|}
|}
=== Non-Invasive Micro Loop Home Run Cable ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|Global Traffic Technologies bought out 3M
|[http://www.gtt.com/canoga-traffic-sensing Global Traffic Technologies]
|[[media:TRF PQL TS CAT 3M MicroLoopDetectorLeadInCable.pdf|Model Canoga 30003]]
|[[media:TRF PQL TS MEM GTT NonInvasiveLoopDetectorLeadInCable.pdf|2/18/08]]
|
|}
{{PQLReturn}}


=== Radar Detector Home Run Cable ===
=== Radar Detector Home Run Cable ===
Line 375: Line 375:
|[http://www.awcwire.com/ Allied Wire & Cable]
|[http://www.awcwire.com/ Allied Wire & Cable]
|091102WGP12
|091102WGP12
|[[media:TRF PQL TS MEM AlliedWire RadarDetectorCable.pdf|1/10/11]]
|[[Media:TRF PQL TS MEM AlliedWire RadarDetectorCable.pdf|1/10/11]]
|
|
|-
|-
|
|
|[http://www.falconfinewire.com/ Falcon Fine Wire]
|[http://www.falconfinewire.com/ Falcon Fine Wire]
|[[media:TRF PQL TS CAT FalconFineWire RadarDetectorHomeRunCable.pdf|532P2218HD-08]]<br>2 pair 22 AWG communication wires<br>1 pair 18 AWG power wires
|[[Media:TRF PQL TS CAT FalconFineWire RadarDetectorHomeRunCable.pdf|532P2218HD-08]]<br>2 pair 22 AWG communication wires<br>1 pair 18 AWG power wires
|[[media:TRF PQL TS MEM FalconFineWire RadarDetectorHomeRunCable.pdf|11/13/14]]
|[[Media:TRF PQL TS MEM FalconFineWire RadarDetectorHomeRunCable.pdf|11/13/14]]
|[[media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable.JPG|Separated Cable]]<br>[[media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable Stripped.JPG|Bundled Cable]]<br>[[media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable Label1.JPG|"Matrix Advance" Label]]<br>[[media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable Label2.JPG|Label showing wire guage]]
|[[Media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable.JPG|Separated Cable]]<br>[[Media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable Stripped.JPG|Bundled Cable]]<br>[[Media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable Label1.JPG|"Matrix Advance" Label]]<br>[[Media:TRF PQL TS PHOT FalconFineWire RadarDetectorHomeRunCable Label2.JPG|Label showing wire guage]]
|-
|-
|
|
|[http://www.wavetronix.com/en/support/product_lines/1/products/121 Orion Wire / Wavetronix]
|[http://www.wavetronix.com/en/support/product_lines/1/products/121 Orion Wire / Wavetronix]
|[[media:TRF PQL TS CAT Wavetronix RadarHomeRunDetectorCable.pdf|WX-SS-H705]]
|[[Media:TRF PQL TS CAT Wavetronix RadarHomeRunDetectorCable.pdf|WX-SS-H705]]
|[[media:TRF PQL TS MEM Wavetronix RadarHomeRunDetectorCable.pdf|1/10/11]]
|[[Media:TRF PQL TS MEM Wavetronix RadarHomeRunDetectorCable.pdf|1/10/11]]
|
|
|}
|}
Line 404: Line 404:
|
|
|[http://www.wavetronix.com/en/support/product_lines/1/products/121 Orion Wire / Wavetronix]
|[http://www.wavetronix.com/en/support/product_lines/1/products/121 Orion Wire / Wavetronix]
|[[media:TRF PQL TS CAT Wavetronix RadarDetectorHarnessCable.pdf|WX-SS-H704-100]]
|[[Media:TRF PQL TS CAT Wavetronix RadarDetectorHarnessCable.pdf|WX-SS-H704-100]]
|[[media:TRF PQL TS MEM Orion RadarDetectorHarnessCable.pdf|1/10/11]]
|[[Media:TRF PQL TS MEM Orion RadarDetectorHarnessCable.pdf|1/10/11]]
|
|
|}
|}
Line 422: Line 422:
|
|
|[http://www.advanceddigitalcable.com/detection-notification/imsa-50-2-loop-lead-in.html Advanced Digital Cable]
|[http://www.advanceddigitalcable.com/detection-notification/imsa-50-2-loop-lead-in.html Advanced Digital Cable]
|[[media:TRF PQL TS CAT AdvancedDigitalCable ShieldedDetectorLeadInCable.pdf|8780]]
|[[Media:TRF PQL TS CAT AdvancedDigitalCable ShieldedDetectorLeadInCable.pdf|8780]]
|[[media:TRF PQL TS MEM AdvancedDigitalCable ShieldedDetectorLeadInCable.pdf|6/29/09]]
|[[Media:TRF PQL TS MEM AdvancedDigitalCable ShieldedDetectorLeadInCable.pdf|6/29/09]]
|[[media:TRF PQL TS PHOT AdvancedDigitalCable ShieldedDetectorLeadInCable Cable.JPG|Cable]]
|[[Media:TRF PQL TS PHOT AdvancedDigitalCable ShieldedDetectorLeadInCable Cable.JPG|Cable]]
|-  
|-  
|
|
|[http://www.belden.com/products/ Belden]
|[http://www.belden.com/products/ Belden]
|[[media:TRF PQL TS CAT BeldenCable ShieldedDetectorLeadInCable.pdf|601765]]
|[[Media:TRF PQL TS CAT BeldenCable ShieldedDetectorLeadInCable.pdf|601765]]
|[[media:TRF PQL TS MEM BeldenCable ShieldedDetectorLeadInCable.pdf|2/1/01]]
|[[Media:TRF PQL TS MEM BeldenCable ShieldedDetectorLeadInCable.pdf|2/1/01]]
|[[media:TRF PQL TS PHOT BeldenCable ShieldedDetectorLeadInCable Cable.JPG|Cable]]
|[[Media:TRF PQL TS PHOT BeldenCable ShieldedDetectorLeadInCable Cable.JPG|Cable]]
|-
|-
|This is actually a Belden Cable
|Clifford of Vermont
|1P14T19I50-2
|[[media:TRF PQL TS MEM CliffordofVT ShieldedDetectorLeadInCable.pdf|5/5/03]]
|
|-
|
|
|[http://www.falconfinewire.com/#!__products/vstc1=trafficcontrol&signalcables Falcon Fine Wire]
|[http://www.falconfinewire.com/#!__products/vstc1=trafficcontrol&signalcables Falcon Fine Wire]
|[[media:TRF PQL TS CAT FalconFineWire ShieldedDetectorLeadInCable.pdf|98021450-2]]
|[[Media:TRF PQL TS CAT FalconFineWire ShieldedDetectorLeadInCable.pdf|98021450-2]]
|[[media:TRF PQL TS MEM FalconFineWire ShieldedDetectorLeadInCable.pdf|5/5/06]]
|[[Media:TRF PQL TS MEM FalconFineWire ShieldedDetectorLeadInCable.pdf|5/5/06]]
|[[media:TRF PQL TS PHOT FalconFineWire ShieldedDetectorLeadInCable Cable.JPG|Cable]]
|[[Media:TRF PQL TS PHOT FalconFineWire ShieldedDetectorLeadInCable Cable.JPG|Cable]]<br>[[Media:TRF PQL TS PHOT FalconFineWire ShieldedDetectorLeadInCable Label.JPG|Label]]<br>[[Media:TRF PQL TS PHOT FalconFineWire ShieldedDetectorLeadInCable Shield.JPG|Shield and Drain Wire]]
|-  
|-  
|
|
|General Cable
|[http://www.jamesmonroewire.com/ James Monroe Wire and Cable Corporation]
|C2550
|[[Media:TRF PQL TS CAT JamesMonroeCable ShieldedDetectorLeadInCable.pdf|JM43465]]
|[[media:TRF PQL TS MEM GeneralCable ShieldedDetectorLeadInCable.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM JamesMonroeCable ShieldedDetectorLeadInCable.pdf|9/1/99]]
|
|
|-
|}
|
|[http://www.jamesmonroewire.com/imsa.html James Monroe Wire and Cable Corporation]
|[[media:TRF PQL TS CAT JamesMonroeCable ShieldedDetectorLeadInCable.pdf|JM43465]]
|[[media:TRF PQL TS MEM JamesMonroeCable ShieldedDetectorLeadInCable.pdf|9/1/99]]
|
|}
{{PQLNote|IMSA Type 50-2 Loop Lead-in Cable<br>Polyethylene Insulated<br>600 Volt<br>Stranded Copper<br>#14 AWG}}
{{PQLNote|IMSA Type 50-2 Loop Lead-in Cable<br>Polyethylene Insulated<br>600 Volt<br>Stranded Copper<br>#14 AWG}}
{{PQLReturn}}
{{PQLReturn}}
Line 470: Line 458:
|
|
|[http://adcable.com/products/industrial-wire-cable.html Advanced Digital Cable]
|[http://adcable.com/products/industrial-wire-cable.html Advanced Digital Cable]
|[[media:TRF PQL TS CAT AdvancedDigitalCable SystemGroundCable.pdf|Green - 410GN<br>Red - 410RD]]<br>UL File # E208489
|[[Media:TRF PQL TS CAT AdvancedDigitalCable SystemGroundCable.pdf|Green - 410GN<br>Red - 410RD]]<br>UL File # E208489
|[[media:TRF PQL TS MEM AdvancedDigitalCable SystemGroundCable.pdf|5/20/16]]
|[[Media:TRF PQL TS MEM AdvancedDigitalCable SystemGroundCable.pdf|5/20/16]]
|[[media:TRF PQL TS PHOT AdvancedDigitalCable SystemGroundCable.JPG|Ground Cable]]<br>[[media:TRF PQL TS PHOT AdvancedDigitalCable SystemGroundCable Label.JPG|Mfg Label]]<br>[[media:TRF PQL TS PHOT AdvancedDigitalCable SystemGroundCable AWG Label.JPG|AWG Label]]<br>[[media:TRF PQL TS PHOT AdvancedDigitalCable TracerCable.JPG|Tracer Cable]]
|[[Media:TRF PQL TS PHOT AdvancedDigitalCable SystemGroundCable.JPG|Ground Cable]]<br>[[Media:TRF PQL TS PHOT AdvancedDigitalCable SystemGroundCable Label.JPG|Mfg Label]]<br>[[Media:TRF PQL TS PHOT AdvancedDigitalCable SystemGroundCable AWG Label.JPG|AWG Label]]<br>[[Media:TRF PQL TS PHOT AdvancedDigitalCable TracerCable.JPG|Tracer Cable]]
|-
|-
|
|
|[http://www.cerrowire.com/circuit-sized-thhn--thwn Cerowire Wire & Cable Co., Inc.]
|[http://www.cerrowire.com/circuit-sized-thhn--thwn Cerowire Wire & Cable Co., Inc.]
|[[media:TRF PQL SL CAT CerroWire Pole&BracketCable.pdf|Red – 112-3803<br>Green – 112-3805<br>UL file # E15119]]
|[[Media:TRF PQL SL CAT CerroWire Pole&BracketCable.pdf|Red – 112-3803<br>Green – 112-3805<br>UL file # E15119]]
|[[media:TRF PQL TS MEM CerroWire SystemGroundandTracerWire.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM CerroWire SystemGroundandTracerWire.pdf|5/5/03]]
|
|
|-  
|-  
|
|
|Encore Wire LTD
|[https://www.encorewire.com/ Encore Wire LTD]
|UL file # E123774
|[[Media:TRF PQL TS CAT Encore SystemGroundandTracerWire.pdf|UL file # E123774]]
|[[media:TRF PQL TS MEM Encore SystemGroundandTracerWire.pdf|8/1/03]]
|[[Media:TRF PQL TS MEM Encore SystemGroundandTracerWire.pdf|8/1/03]]
|
|
|-
|-
|Purchased by Southwire Co.
|Essex Group, Inc.
|Product Number 070101<br>UL File # E14656
|2/1/01
|
|
|-  
|[https://www.republicwire.com/products Republic Wire]
|[[media:TRF PQL TS CAT RepublicWire SystemGroundTracerCable.pdf|UL File E167613]]
|[[media:TRF PQL TS MEM RepublicWire SystemGroundTracerCable.pdf|5/8/23]]
|[[media:TRF PQL TS PHOT RepublicWire SystemGroundTracerCable Label1.JPG|Label Name]]<br>[[media:TRF PQL TS PHOT RepublicWire SystemGroundTracerCable Label2.JPG|Label Cable Type]]<br>[[media:TRF PQL TS PHOT RepublicWire SystemGroundTracerCable Label3.JPG|Label UL File]]
|-
|
|
|Senator / Southwire
|[https://www.southwire.com/ Southwire]
|22-97-57<br>UL file # E23919
|[[Media:TRF PQL TS CAT Southwire SystemGroundCable.pdf|Green - 22-97-73<br>Red - 22-97-57<br>UL file # E23919]]
|[[media:TRF PQL TS MEM Southwire SystemGroundandTracerWire.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Southwire SystemGroundandTracerWire.pdf|5/5/03]]
|
|
|-  
|-  
|
 
|Service Wire
|UL file # E105667
|5/7/02
|
|-
|
|United Copper Industries
|Red – 325372 (500’ reel)<br>Green – 325379 (500’ reel)<br><br>Red – 325574 (2,500’ reel)<br>Green – 325580 (2,500’ reel)<br><br>UL file # E194031-A
|[[media:TRF PQL TS MEM UnitedCopperIndustries SystemGroundandTracerWire.pdf|5/26/09]]
|
|}
|}
{{PQLNote|Stranded copper #10 AWG THHN<br>600 volt<br>Tracer wire shall have Red insulation<br>Ground wire shall have Green insulation}}
{{PQLNote|Stranded copper #10 AWG THHN/THWN-2<br>600 volt<br>Tracer wire shall have Red insulation<br>Ground wire shall have Green insulation}}
 


=== #6 AWG Equipment Ground Wire ===
=== #6 AWG Equipment Ground Wire ===
Line 524: Line 501:
|
|
|[http://adcable.com/products/industrial-wire-cable.html Advanced Digital Cable]
|[http://adcable.com/products/industrial-wire-cable.html Advanced Digital Cable]
|[[media:TRF PQL TS CAT AdvancedDigitalCable GroundingCable.pdf|BC06S]]
|[[Media:TRF PQL TS CAT AdvancedDigitalCable GroundingCable.pdf|BC06S]]
|[[media:TRF PQL TS MEM AdvancedDigitalCable GroundingCable.pdf|5/20/16]]
|[[Media:TRF PQL TS MEM AdvancedDigitalCable GroundingCable.pdf|5/20/16]]
|[[media:TRF PQL TS PHOT AdvancedDigitalCable GroundingCable.JPG|Bare Copper Cable]]
|[[Media:TRF PQL TS PHOT AdvancedDigitalCable GroundingCable.JPG|Bare Copper Cable]]
|-
|-
|
|
|[http://www.cerrowire.com/bare-copper Cerro Wire & Cable Co, Inc.]
|[https://www.cerrowire.com/ Cerro Wire & Cable Co, Inc.]
|[[media:TRF PQL SL CAT CerroWire GroundCable.pdf|Product Number<br>050-2200 or 050-2215]]
|[[Media:TRF PQL SL CAT CerroWire GroundCable.pdf|Product Number<br>050-2200 or 050-2215]]
|[[media:TRF PQL TS MEM Cerro EquipmentGroundWire.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Cerro EquipmentGroundWire.pdf|5/5/03]]
|
|
|-
|-
|
|
|Encore Wire LTD
|[https://www.encorewire.com/ Encore Wire LTD]
|Bare No. 6 AWG
|[[Media:TRF PQL TS CAT Encore EquipmentGroundWire.pdf|Bare No. 6 AWG]]
|[[media:TRF PQL TS MEM Encore EquipmentGroundWire.pdf|8/1/03]]
|[[Media:TRF PQL TS MEM Encore EquipmentGroundWire.pdf|8/1/03]]
|
|
|-
|-
|
|
|[http://www.southwire.com/ Southwire]
|[http://www.servicewire.com/ Service Wire Co]
|Bare No. 6 AWG
|[[Media:TRF PQL TS CAT ServiceWire GroundWire.pdf|BSOS6]]
|[[media:TRF PQL TS MEM South GroundWire.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM ServiceWire EquipmentGroundWire.pdf|5/5/03]]
|
|
|-
|-
|
|
|[http://www.servicewire.com/ Service Wire Co]
|[http://www.southwire.com/ Southwire]
|[[media:TRF PQL TS CAT ServiceWire GroundWire.pdf|BSOS6]]
|[[Media:TRF PQL TS CAT Southwire GroundWire.pdf|Bare No. 6 AWG]]
|[[media:TRF PQL TS MEM ServiceWire EquipmentGroundWire.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM South GroundWire.pdf|5/5/03]]
|
|
|}
|}
{{PQLNote|Bare copper soft drawn solid copper #6 AWG}}
{{PQLNote|Bare copper soft drawn solid copper #6 AWG}}


=== Video Detection Cable ===
=== Video Detection Cable ===
Line 568: Line 544:
|[http://www.falconfinewire.com/ Falcon Fine Wire]
|[http://www.falconfinewire.com/ Falcon Fine Wire]
|970316TS-00-1MP
|970316TS-00-1MP
|[[media:TR PQL TS MEM FalconFineWire VideoDetectionCable.pdf|1/30/12]]
|[[Media:TR PQL TS MEM FalconFineWire VideoDetectionCable.pdf|1/30/12]]
|[[media:TR PQL TS PHOT FalconFineWire VideoDetectionCable Cable.pdf|Cable]]<br>[[media:TR PQL TS PHOT FalconFineWire VideoDetectionCable Jacket.pdf|Jacket]]
|[[Media:TR PQL TS PHOT FalconFineWire VideoDetectionCable Cable.pdf|Cable]]<br>[[Media:TR PQL TS PHOT FalconFineWire VideoDetectionCable Jacket.pdf|Jacket]]
|-
|-
|Econolite Exclusive
|Econolite Exclusive
|Isotec
|Isotec
|X339313-00 (for Econolite Solo Terra Systems)
|X339313-00 (for Econolite Solo Terra Systems)
|[[media:TR PQL TS MEM Isotec VideoDetectionCable.pdf|4/25/08]]
|[[Media:TR PQL TS MEM Isotec VideoDetectionCable.pdf|4/25/08]]
|[[media:TRF PQL TS PHOT Isotec VideoDetectionCable Cable.JPG|Cable]]
|[[Media:TRF PQL TS PHOT Isotec VideoDetectionCable Cable.JPG|Cable]]
|}
|}
{{PQLNote|16 AWG/3c}}
{{PQLNote|16 AWG/3c}}
Line 589: Line 565:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|
|[https://www.bdiky.com/ Blue Diamond Industires]
|[[media:TRF PQL TS CAT BlueDiamond 1inHDPECond.pdf|1" - BDI114BK-WHS]]<br>[[media:TRF PQL TS CAT BlueDiamond 1.5inHDPECond.pdf|1 ½” - BDI164BK-WHS]]<br>[[media:TRF PQL TS CAT BlueDiamond 2inHDPECond.pdf|2" - BDI214BK-WHS]]<br>[[media:TRF PQL TS CAT BlueDiamond 3inHDPECond.pdf|3" - BDI314BK-WHS]]<br>[[media:TRF PQL TS CAT BlueDiamond 4inHDPECond.pdf|4" -BDI414BK-WHS]]
|[[media:TRF PQL TS MEM CAT BlueDiamond HDPECond.pdf|3/9/23]]
|[[media:TRF PQL TS PHOT BlueDiamond 1.5inHDPECond Label.JPG|1 ½” Cond Line Code]]<br>[[media:TRF PQL TS PHOT BlueDiamond 2inHDPECond Label.JPG|2" Cond Line Code]]<br>[[media:TRF PQL TS PHOT BlueDiamond 3inHDPECond Label.JPG|3" Cond Line Code]]<br>[[media:TRF PQL TS PHOT BlueDiamond 4inHDPECond Label.JPG|4" Cond Line Code]]<br>[[media:TRF PQL TS PHOT BlueDiamond HDPECond EndView.JPG|End View]]
|-
|-
|
|
|[http://www.duraline.com/conduit/smoothwall Dura-Line]
|[http://www.duraline.com/conduit/smoothwall Dura-Line]
|[[media:TRF PQL TS CAT DuraLine HDPESignalConduit.pdf|1” – HDP100RSDR013SWBLKWHTNEMPT<br>1 ½” – HDP150RSDR013SWBLKWHTNEMPT<br>2” – HDP200RSDR013SWBLKWHTNEMPT<br>3” – HDP300RSDR013SWBLKWHTNEMPT<br>4” – HDP400RSDR013SWBLKWHTNEMPT]]
|[[Media:TRF PQL TS CAT DuraLine HDPESignalConduit.pdf|1” – HDP100RSDR013SWBLKWHTNEMPT<br>1 ½” – HDP150RSDR013SWBLKWHTNEMPT<br>2” – HDP200RSDR013SWBLKWHTNEMPT<br>3” – HDP300RSDR013SWBLKWHTNEMPT<br>4” – HDP400RSDR013SWBLKWHTNEMPT]]
|[[media:TRF PQL TS MEM DuraLine HDPEConduit.pdf|1/09/17]]
|[[Media:TRF PQL TS MEM DuraLine HDPEConduit.pdf|1/09/17]]
|
|
|}
|}
Line 606: Line 588:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|
|[https://www.bdiky.com/ Blue Diamond Industries]
|[[media:TRF PQL TS CAT BlueDiamond 2inElecServiceHDPECond.pdf|2" - BDI214BK-RDS]]<br>[[media:TRF PQL TS CAT BlueDiamond 3inElecServiceHDPECond.pdf|3" - BDI314BK-RDS]]
|[[media:TRF PQL TS MEM BlueDiamond ElecServiceHDPECond.pdf|3/9/23]]
|
|-
|-
|
|
|[http://www.duraline.com/conduit/smoothwall Dura-Line]
|[http://www.duraline.com/conduit/smoothwall Dura-Line]
|[[media:TRF PQL TS CAT DuraLine HDPEServiceConduit.pdf|2” – 2SDR135BLK/RED<br>3” – 3SDR135BLK/RED]]
|[[Media:TRF PQL TS CAT DuraLine HDPEServiceConduit.pdf|2” – 2SDR135BLK/RED<br>3” – 3SDR135BLK/RED]]
|[[media:TRF PQL TS MEM DuraLine HDPEServiceConduit.pdf|3/8/13]]
|[[Media:TRF PQL TS MEM DuraLine HDPEServiceConduit.pdf|3/8/13]]
|
|
|}
|}
Line 627: Line 615:
|
|
|[http://www.polywater.com/index.html American Polywater]
|[http://www.polywater.com/index.html American Polywater]
|[[media:TRF PQL TS CAT AmericanPolywater Bonduit.pdf|Bonduit Conduit Adhesive]]<br>Use with standard Sch 40 PVC Couplings
|[[Media:TRF PQL TS CAT AmericanPolywater Bonduit.pdf|Bonduit Conduit Adhesive]]<br>Use with standard Sch 40 PVC Couplings
|[[media:TRF PQL TS MEM AmericanPolywater Bonduit.pdf|10/11/10]]
|[[Media:TRF PQL TS MEM AmericanPolywater Bonduit.pdf|10/11/10]]
|[[media:TRF PQL TS PHOT AmericanPolywater Bonduit.JPG|Cartridge]]<br>[[media:TRF PQL TS PHOT AmericanPolywater Bonduit Equipment.JPG|Equipment]]<br>[[media:TRF PQL TS PHOT AmericanPolywater Bonduit Nozzle.JPG|Nozzle]]
|[[Media:TRF PQL TS PHOT AmericanPolywater Bonduit.JPG|Cartridge]]<br>[[Media:TRF PQL TS PHOT AmericanPolywater Bonduit Equipment.JPG|Equipment]]<br>[[Media:TRF PQL TS PHOT AmericanPolywater Bonduit Nozzle.JPG|Nozzle]]
|-
|-
|
|
|[http://www.cable-tec.com/aluminum-couplers.html Cabletec]
|[https://www.cabletecusa.com/ Cabletec]
|HDPE to HDPE Coupling:<br>[[media:TRF PQL TS CAT Cabletec HDPEtoHDPECouplings.pdf|1" - AS 1.315<br>1-1/2" - AS 1.900<br>2" - AS 2.375<br>3" - AS 3.500<br>4" - AS 4.500]]<br>HDPE to PVC Coupling:<br>[[media:TRF PQL TS CAT Cabletec HDPEtoPVCCouplings.pdf|1" - ASP 1.315<br>1-1/2" - ASP 1.900<br>2" - ASP 2.375<br>3" - ASP 3.500<br>4" - ASP 4.500]]
|HDPE to HDPE Coupling:<br>[[Media:TRF PQL TS CAT Cabletec HDPEtoHDPECouplings.pdf|1" - AS 1.315<br>1-1/2" - AS 1.900<br>2" - AS 2.375<br>3" - AS 3.500<br>4" - AS 4.500]]<br>HDPE to PVC Coupling:<br>[[Media:TRF PQL TS CAT Cabletec HDPEtoPVCCouplings.pdf|1" - ASP 1.315<br>1-1/2" - ASP 1.900<br>2" - ASP 2.375<br>3" - ASP 3.500<br>4" - ASP 4.500]]
|[[media:TRF PQL TS MEM Cabletec HDPEtoHDPECouplings.pdf|8/2/01]]<br><br><br><br><br>[[media:TRF PQL TS MEM Cabletec HDPEtoPVCCouplings.pdf|12/22/17]]
|[[Media:TRF PQL TS MEM Cabletec HDPEtoHDPECouplings.pdf|8/2/01]]<br><br><br><br><br>[[Media:TRF PQL TS MEM Cabletec HDPEtoPVCCouplings.pdf|12/22/17]]
|
|
|-
|-
|
|
|[http://www.duraline.com/catalog/couplers/push-lock Dura-Line]
|[http://www.duraline.com/catalog/couplers/push-lock Dura-Line]
|HDPE to HDPE Coupling or HDPE to PVC Coupling:<br>[[media:TRF PQL TS CAT DuraLine ShurLockCoupling.pdf|ShurLock Couplings<br>1" - 20000118<br>1 ½” – 20000122<br>2" - 20000123<br>3" - 20000173<br>4" - 20000245]]
|HDPE to HDPE Coupling or HDPE to PVC Coupling:<br>[[Media:TRF PQL TS CAT DuraLine ShurLockCoupling.pdf|ShurLock Couplings<br>1" - 20000118<br>1 ½” – 20000122<br>2" - 20000123 (1-400761)<br>3" - 20000173<br>4" - 20000245]]
|[[media:TRF PQL TS MEM DuraLine ShurlockCoupling.pdf|7/11/14]]
|[[Media:TRF PQL TS MEM DuraLine ShurlockCoupling.pdf|7/11/14]]
|[[media:TRF PQL TS PHOT DuraLine ShurLockCoupling Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT DuraLine ShurLockCoupling Label.jpg|Label View]]<br>[[media:TRF PQL TS PHOT DuraLine ShurLockCoupling End.jpg|End View]]
|[[Media:TRF PQL TS PHOT DuraLine ShurLockCoupling Side.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT DuraLine ShurLockCoupling Label.jpg|Label View]]<br>[[Media:TRF PQL TS PHOT DuraLine ShurLockCoupling End.jpg|End View]]
|-
|-
|
|
|[http://www.centralplastics.com/en_US.html Georg Fischer/Central Plastics Company]
|[http://www.centralplastics.com/en_US.html Georg Fischer/Central Plastics Company]
|HDPE to HDPE Electrofusion Couplings<br>[[media:TRF PQL TS CAT GFCP HDPE Couplings.pdf|1 ½” - 5760028<br>2” - 5760030<br>3” - 10000358<br>4” - 10000360]]
|HDPE to HDPE Electrofusion Couplings<br>[[Media:TRF PQL TS CAT GFCP HDPE Couplings.pdf|1 ½” - 5760028<br>2” - 5760030<br>3” - 10000358<br>4” - 10000360]]
|[[media:TRF PQL TS MEM GFCP HDPE Couplings.pdf|5/5/06]]
|[[Media:TRF PQL TS MEM GFCP HDPE Couplings.pdf|5/5/06]]
|
|
|-
|-
Line 653: Line 641:
{{PQLReturn}}
{{PQLReturn}}


=== PVC Conduit ===
=== Schedule 40 PVC Conduit ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 661: Line 649:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|Part of Atkore International
|[https://www.atkore.com/About-Us/Brands/Allied-Tube-and-Conduit Allied Tube & Conduit]
|[[media:TRF PQL TS CAT AlliedTube Sch40PVCConduit.pdf|1" - 4010010 (10' length)<br>1" - 4010020 (20' length)<br>1 ½” - 4015010 (10' length)<br>1 ½” - 4015020 (20' length)<br>2" - 4020010 (10' length)<br>2" - 4020020 (20' length)<br>3" - 4030010 (10' length)<br>3" - 4030020 (20' lengths)<br>4" - 4040010 (10' length)<br>4" - 4040020 (20' length)]]
|[[media:TRF PQL TS MEM AlliedTube Sch40PVCConduit.pdf|8/30/23]]
|
|-
|-
|
|
|[http://www.cantexinc.com/Products/Schedule_40/Conduit/index.php Cantex]
|[http://www.cantexinc.com/Products/Schedule_40/Conduit/index.php Cantex]
|[[media:TRF PQL TS CAT Cantex PVCConduit.pdf|1” – A52BA12<br>1 ½” – A52BE12<br>  2” – A52CA12<br>3” – A52DA12<br>4” – A52EA12]]
|[[Media:TRF PQL TS CAT Cantex PVCConduit.pdf|1” – A52BA12<br>1 ½” – A52BE12<br>  2” – A52CA12<br>3” – A52DA12<br>4” – A52EA12]]
|[[media:TRF PQL TS MEM Cantex PVCConduit.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Cantex PVCConduit.pdf|5/5/03]]
|
|
|-
|-
|
|Part of Atkore International
|[http://www.heritageplastics.com/index.htmll Heritage Plastics]
|[http://www.heritageplastics.com/ Heritage Plastics]
|[[media:TRF PQL TS CAT HeritagePlastics PVCConduit.pdf|1” – 511010 (10’ length)<br>1" - 511020 (20’ length)<br>1 ½” – 511510 (10’ length)<br>1 ½” - 511520 (20’ length)<br>2” – 512010 (10’ length)<br>2" - 512020 (20’ length)<br>3” – 513010 (10’ length)<br>3" - 513020 (20’ length)<br>4” – 514010 (10’ length)<br>4" - 515020 (20’ length)]]
|[[Media:TRF PQL TS CAT HeritagePlastics PVCConduit.pdf|1” – 511010 (10’ length)<br>1" - 511020 (20’ length)<br>1 ½” – 511510 (10’ length)<br>1 ½” - 511520 (20’ length)<br>2” – 512010 (10’ length)<br>2" - 512020 (20’ length)<br>3” – 513010 (10’ length)<br>3" - 513020 (20’ length)<br>4” – 514010 (10’ length)<br>4" - 515020 (20’ length)]]
|[[media:TRF PQL TS MEM HeritagePlastics PVCConduit.pdf|7/24/12]]
|[[Media:TRF PQL TS MEM HeritagePlastics PVCConduit.pdf|7/24/12]]
|
|
|-
|-
|
|
|[http://www.ipexinc.com/Home.aspx?LanguageCode=en-CA IPEX / Scepter]
|[http://www.ipexinc.com/Home.aspx?LanguageCode=en-CA IPEX / Scepter]
|[[media:TRF PQL TS CAT IPEXScepter PVCConduit.pdf|1” – 032410 – 10’or 032411 – 20’<br>1 ½” – 032415 – 10’or 032416 – 20’<br>2” – 032420 – 10’ or 032421 – 20’<br>3” – 032430 – 10’ or 032431 – 20’<br>4” – 032440 – 10’ or 032441 – 20’]]
|[[Media:TRF PQL TS CAT IPEXScepter PVCConduit.pdf|1” – 032410 – 10’or 032411 – 20’<br>1 ½” – 032415 – 10’or 032416 – 20’<br>2” – 032420 – 10’ or 032421 – 20’<br>3” – 032430 – 10’ or 032431 – 20’<br>4” – 032440 – 10’ or 032441 – 20’]]
|[[media:TRF PQL TS MEM IPEXScepter PVCConduit.pdf|12/22/05]]
|[[Media:TRF PQL TS MEM IPEXScepter PVCConduit.pdf|12/22/05]]
|
|
|-
|-
|
|
|[http://www.primeconduit.com/schedule-40-80/ Prime Conduit]
|[http://www.primeconduit.com/schedule-40-80/ Prime Conduit]
|[[media:TRF PQL TS CAT PrimeConduit PVCConduit.pdf|1” – 49008-010 (10’ length)<br>1” – 49008-020 (20’ length)<br>1 ½” – 49010-010 (10’ length)<br>1 ½” – 49010-020 (20’ length)<br>2” – 49011-010(10’ length)<br>2” – 40911-020 (20’ length) <br>3” – 49013-010 (10’ length)<br>3” – 49013-020 (20’ length)<br>4” – 49015-010 (10’ length)<br>4” – 49015-020 (20’ length)]]
|[[Media:TRF PQL TS CAT PrimeConduit PVCConduit.pdf|1” – 49008-010 (10’ length)<br>1” – 49008-020 (20’ length)<br>1 ½” – 49010-010 (10’ length)<br>1 ½” – 49010-020 (20’ length)<br>2” – 49011-010(10’ length)<br>2” – 40911-020 (20’ length) <br>3” – 49013-010 (10’ length)<br>3” – 49013-020 (20’ length)<br>4” – 49015-010 (10’ length)<br>4” – 49015-020 (20’ length)]]
|[[media:TRF PQL TS MEM PrimeConduit PVCConduit.pdf|5/26/09]]
|[[Media:TRF PQL TS MEM PrimeConduit PVCConduit.pdf|5/26/09]]
|
|
|-
|-
|
|
|[https://cortekconduitsolutions.com/ Rocky Mountain Colby Pipe]
|[https://cortekconduitsolutions.com/ Rocky Mountain Colby Pipe]
|[[media:TRF PQL TS CAT RockyMtnColby PVCConduit.pdf|1" – 504010010U (10' length)<br>1" – 504010020U (20' length)<br>1 1/2" – 504015010 (10' length)<br>1 1/2" – 504015020U (20' length)<br>2” – 504020010U (10’ length)<br>2" – 504020020U (20’ length)<br>3” – 504030010U (10’ length)<br>3" – 504030020U (20' length)<br>4” – 504040010U (10’ length)<br>4" – 504040020U (20’ length)]]
|[[Media:TRF PQL TS CAT RockyMtnColby PVCConduit.pdf|1" – 504010010U (10' length)<br>1" – 504010020U (20' length)<br>1 1/2" – 504015010 (10' length)<br>1 1/2" – 504015020U (20' length)<br>2” – 504020010U (10’ length)<br>2" – 504020020U (20’ length)<br>3” – 504030010U (10’ length)<br>3" – 504030020U (20' length)<br>4” – 504040010U (10’ length)<br>4" – 504040020U (20’ length)]]
|[[media:TRF PQL TS MEM RockyMtnColby PVCConduit.pdf|4/7/09]]
|[[Media:TRF PQL TS MEM RockyMtnColby PVCConduit.pdf|4/7/09]]
|
|
|}
|}
Line 696: Line 690:
{{PQLReturn}}
{{PQLReturn}}


=== PVC Fittings ===
=== Schedule 80 PVC Conduit ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 705: Line 699:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Part of Atkore International
|[https://www.atkore.com/About-Us/Brands/Allied-Tube-and-Conduit Allied Tube & Conduit]
|[[media:TRF PQL TS CAT AlliedTube Sch80PVCConduit.pdf|1" - 8010010 (10' length)<br>1" - 8010020 (20' length)<br>1 ½” - 8015010 (10' length)<br>1 ½” - 8015020 (20' length)<br>2" - 8020010 (10' length)<br>2" - 8020020 (20' length)<br>3" - 8030010 (10' length)<br>3" - 8030020 (20' lengths)<br>4" - 8040010 (10' length)<br>4" - 8040020 (20' length)]]
|[[media:TRF PQL TS MEM AlliedTube Sch80PVCConduit.pdf|8/30/23]]
|
|
|[http://www.alliedeg.us/ Allied Tube & Conduit]
|-
|'''[[media:TRF PQL TS CAT AlliedTube&Conduit PVCCouplings.pdf|Standard Couplings]]:'''<br>&nbsp;1” – 59603<br>&nbsp;1 ½” – 59605<br>&nbsp;2” – 59606<br>&nbsp;3" – 59608<br>&nbsp;4" – 59610
|
'''90º Elbows 36” Radius for Power:<br>([[media:TRF PQL TS CAT AlliedTube&Conduit 36RSpecialPlain90Elbow.pdf|Plain End]]) / (Bell End)'''<br>&nbsp;2” – 59730 / NA<br>
|[http://www.cantexinc.com/index.php Cantex]
'''90º Elbows: ([[media:TRF PQL TS CAT AlliedTube&Conduit PlainEndElbows.pdf|Plain End]] / [[media:TRF PQL TS CAT AlliedTube&Conduit BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59590 /  802754<br>&nbsp;1 ½” – 59592 / 802756<br>&nbsp;2” – 59593 /  807757<br>&nbsp;3” – 59595 / 802759<br>&nbsp;4" – 59597 / 802762<br>
|[[Media:TRF PQL TS CAT Cantex Schedule80PVCConduit.pdf|1” – A53BA12<br>1 ½” – A53BE12<br>2” – A53CA12<br>3" – A53DA12<br>4" – A53EA12]]
'''45º Elbows:([[media:TRF PQL TS CAT AlliedTube&Conduit PlainEndElbows.pdf|Plain End]] / [[media:TRF PQL TS CAT AlliedTube&Conduit BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59577 /  802768<br>&nbsp;1 ½” – 59579 / 802770<br>&nbsp;2” – 59580 / 802771<br>&nbsp;3” – 59582 / 802773<br>&nbsp;4” – 59584 / 802775<br>
|[[Media:TRF PQL TS MEM Cantex Schedule80PVCConduit.pdf|1/29/19]]
'''30º Elbows: ([[media:TRF PQL TS CAT AlliedTube&Conduit PlainEndElbows.pdf|Plain End]] / [[media:TRF PQL TS CAT AlliedTube&Conduit BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59563 /  802780<br>&nbsp;1 ½” – 59565 / 802782<br>&nbsp;2” – 59566 /  802783<br>&nbsp;3" – 59568 / 802785<br>&nbsp;4” – 59570 / 802787<br>
|[[media:TRF PQL TS MEM AlliedTube&Conduit Sch40PVCFittings.pdf|9/3/14]]
|
|
|-
|-
|Part of Atkore International
|[http://www.heritageplastics.com/index.html Heritage Plastics]
|[[Media:TRF PQL TS CAT HeritagePlastics Schedule80PVCConduit.pdf|1” – 9304 (10’ length)<br>1" – 9504 (20’ length)<br>1 ½” – 9306 (10’ length)<br>1 ½” – 9506 (20’ length)<br>2” – 9308 (10’ length)<br>2" – 9508 (20’ length)<br>3” – 9312 (10’ length)<br>3" – 9512 (20’ length)<br>4” – 9316 (10’ length)<br>4" – 9516(20’ length)]]
|[[Media:TRF PQL TS MEM HeritagePlastics Schedul80PVCConduit.pdf|1/29/19]]
|
|
|[http://www.cantexinc.com/Products/NM_Fittings_Accessories/ Cantex]
|-
|'''[[media:TRF PQL TS CAT Cantex PVCFittings Coupling.pdf|Standard Couplings:]]'''<br>1” – 6141625<br>1 ½” – 6141627<br>2” – 6141628<br>3” – 6141630<br>4” - 6141632<br>
'''90º Elbows 36” Radius for Power:<br>([[media:TRF PQL TS CAT Cantex PVCFittings 36RSpecialPlain90Elbow.pdf|Plain End]]) / ([[media:TRF PQL TS CAT Cantex PVCFittings 36RSpecialBelled90Elbow.pdf|Belled End]])'''<br>2” – 5133848 / 5233848<br>
'''90º Elbows: ([[media:TRF PQL TS CAT Cantex PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[media:TRF PQL TS CAT Cantex PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” – 5133825 /  5233825<br>1 ½” – 5133827 / 5233827<br>2” – 5133828 /  5233828<br>3” – 5133830 /  5233830<br>4” – 5133832 /  5233832<br>
'''45º Elbows: ([[media:TRF PQL TS CAT Cantex PVCFittings 45ElbowPlainEnd.pdf|Plain End]] / [[media:TRF PQL TS CAT Cantex PVCFittings 45BelledEnd.pdf|Belled End]])'''<br>1” – 5133765 / 5233765<br>1 ½” – 5133767 / 5233767<br>2” – 5133768 /  5233768<br>3” – 5133770 /  5233770<br>4” – 5133772 /  5233772<br>
'''30º  Elbows:  (Plain End / Belled End)'''<br>1” – 5133745 /  5233745<br>1 ½” – 5133747 / 5233747<br>2” – 5133748 /  [[media:TRF PQL TS CAT Cantex PVCFittings 30BelledEnd2-4in.pdf|5233748]]<br>3” – 5133750 / [[media:TRF PQL TS CAT Cantex PVCFittings 30BelledEnd2-4in.pdf|5233750]]<br>4” – 5133775 /  [[media:TRF PQL TS CAT Cantex PVCFittings 30BelledEnd2-4in.pdf|5233776]]
|[[media:TRF PQL TS MEM Cantex PVCFittings.pdf|5/5/03]]
|
|-  
|
|
|[http://www.heritageplastics.com/products-downloads.html Heritage Plastics]
|[http://www.ipexamerica.com/default.aspx IPEX / Scepter]
|'''[[media:TRF PQL TS CAT HeritagePlastics PVCFittings Coupling.pdf|Standard Couplings:]]'''<br>1” – 610002<br>1 ½” – 610004<br>2” – 610005<br>3” – 610007<br>4” – 610009<br>
|[[Media:TRF PQL TS CAT IpexScepter Schedule80PVCConduit.pdf|1” – 032510 (10’length)<br>1” 032511 (20’ length)<br>1 ½” – 032515 (10' length)<br>1 ½” – 032516 (20' length)<br>2” – 032520 (10’length)<br>2" 032521 (20’ length)<br>3” 032530 (10’ length)<br>3" - 032531 (20’ length)<br>4” 032540 (10’ length)<br>4" 032541 (20’ length)]]
'''90º Elbows 36” Radius for Power:<br>([[media:TRF PQL TS CAT HeritagePlastics PVCFittings 36RSpecialPlain90Elbow.pdf|Plain End]]) / [[media:TRF PQL TS CAT HeritagePlastics PVCFittings 36RSpecialBelled90Elbow.pdf|Belled End]])'''<br> 2” 611353 / 611140<br>
|[[Media:TRF PQL TS MEM IPEXScepter Schedule80PVCConduit.pdf|1/29/19]]
'''90º Elbows: ([[media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” – 611002  / 611058<br>1 ½” – 611004 /611060<br>2” – 611005 / 611061<br>3” – 611007 / 611063<br>4” – 611009 / 611065<br>
'''45º Elbows: ([[media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” – 611016 / 611071<br>1 ½” – 611018 / 611073<br>2” – 611019  / 611074<br>3” 611021 / 611076<br>4” 611023 / 611078<br>
'''30º Elbows: ([[media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” 611030 / 611085<br>1 ½” 611032 / 611087<br>2” – 611033  / 611088<br>3” – 611035 / 611090<br>4” – 611037 / 611092
|[[media:TRF PQL TS MEM HeritagePlastics PVCFittings.pdf|7/24/12]]
|
|
|-
|-
|
|
|[http://www.ipexinc.com/Home.aspx?LanguageCode=en-CA IPEX / Scepter]
|[http://www.primeconduit.com/ Prime Conduit]
|[[media:TRF PQL TS CAT IPEXScepter PVCCouplings.pdf|'''Standard Couplings:''']]<br>1” – EC20 / 077003<br>1 ½” – EC30 / 077005<br>2” EC35 / 077006<br>3” – EC45 / 077008<br>4” EC55 / 077010<br>
|[[Media:TRF PQL TS CAT PrimeConduit Schedule80PVCConduit.pdf|1” – 49408-010 (10’ length)<br>1” – 49408-020 (20’ length)<br>1 1/2" 49410-010 (10' length)<br>1 1/2" 49410-020 (20' length)<br>2” – 49411-010 (10’ length)<br>2” – 40911-020 (20’ length)<br>3” –  49413-010 (10’ length)<br>3” – 49413-020 (20’ length)<br>4" 49415-010 (10' length)<br>4" 49415-020 (20' length)]]
'''90º Elbows 36” Radius for Power:<br>([[media:TRF PQL TS CAT IPEXScepter PVCLargeRadiusElbows.pdf|Plain End / Belled End)]]'''<br>2” – 068765 / 068054<br>
|[[Media:TRF PQL TS MEM PrimeConduit Schedule80PVCConduit.pdf|1/29/19]]
'''90º Elbows: ([[media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” – EE2090 / EE2090B<br>1 ½” – EE3090 / EE3090B<br>2” – EE3590 / EE3590B<br>3” – EE4590 / EE4590B<br>4” – EE5590 /  EE5590B<br>
'''45º Elbows: ([[media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” – EE2045 / EE2045B<br>1 ½” – EE3045 / EE3045B<br>2” – EE3545 / EE3545B<br>3” – EE4545 / EE4545B<br>4” EE5545 / EE5545B<br>
'''30º  Elbows:  ([[media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” EE2030 / NA<br>1 ½” – EE3030 / NA<br>2” – EE3530 / NA<br>3” – EE4530 / NA<br>4” – EE5530 / NA<br>
'''22.5º  Elbows:  ([[media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” – NA / NA<br>1 ½” – EE1522 / NA<br>2” – EE2022 / NA<br>3” – EE3022 / NA<br>4” – EE4022 / NA
|[[media:TRF PQL TS MEM IPEXScepter PVCStdFittings.pdf|12/22/05]]
|
|
|-  
|-
|
|Plastic Trends / Royal Pipe Systems
|'''Standard Couplings:'''<br>1” – E010100<br>1 ½” – E010150<br>2” – E010200<br>3” – E010300<br>4” – E010400<br>
'''90º Elbows 36” Radius for Power:<br>(Plain End / Belled End)'''<br>2” –  E07520036 / E07920036<br>'''90º  Elbows: (Plain End / Belled End)'''<br>1” – E018100 /  E021100<br>1 ½” – E081850 / E 021150<br>2” – E018200 /  E021200<br>3” – E018300 /  E021300<br>4” – E018400 /  E021400<br>
'''45º Elbows: (Plain End / Belled End)'''<br>1” – E019100 /  E022100<br>1 ½” – E0191500 / E022150<br>2” – E019200 /  E022200<br>3” – E019300 /  E022300<br>4” – E019400 /  E022400<br>
'''30º  Elbows:  (Plain End / Belled End)'''<br>1” – E020100 /  E072100<br>1 ½” – E020150 / E072150<br>2” – E020200 /  E072200<br>3” – E020300 /  E072300<br>4” – E020400 /  E072400
|[[media:TRF PQL TS MEM PlasticTrendsRoyalPipeSystems PVCFittings.pdf|1/8/10]]
|
|
|-
|[http://www.rmcp.com/ Rocky Mountain Colby Pipe]
 
|[[Media:TRF PQL TS CAT RockyMountainColbyPipe Schedule80PVCConduit.pdf|1" 508010010U (10' length)<br>1" 508010020U (20' length)<br>1 1/2" 508015010 (10' length)<br>1 1/2" 508015020U (20' length)<br>2” 508020010U (10’ length)<br>2" 508020020U (20’ length)<br>3” 508030010U (10’ length)<br>3" 508030020U (20' length)<br>4” – 508040010U (10’ length)<br>4" – 508040020U (20’ length)]]
|Formerly Carlon
|[[Media:TRF PQL TS MEM RockyMountainColbyPipe Schedule80PVCConduit.pdf|1/29/19]]
|[http://www.primeconduit.com/ Prime Conduit]
|'''[[media:TRF PQL TS CAT PrimeConduit PVCCoupling.pdf|Standard Couplings:]]'''<br>1” – CP100<br>1 ½” CP150<br>2” – CP200<br>3” – CP300<br>4” – CP400<br>
'''90º Elbows 36” Radius for Power:<br>([[media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>2” UA9FJ / UA9FJB<br>'''90º Elbows: ([[media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>1” – UA9AF /  UA9AFB  <br>1 ½” – UA9AH / UA9AHB<br>2” UA9AJ /  UA9AJB<br>3” – UA9AL / UA9ALB<br>4” UA9AN /  UA9ANB<br>
'''45º Elbows: ([[media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>1” UA7AF /  UA7AFB  <br>1 ½” UA7AH / UA7AHB<br>2” UA7AJ /  UA7AJB<br>3” UA7AL /  UA7ALB<br>4” – UA7AN /  UA7ANB<br>
'''30º  Elbows:  ([[media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>1” – UA6AF /  UA6AFB<br>1 ½” – UA6AH / UA6AHB<br>2” – UA6AJ /  UA6AJB<br>3” – UA6AL /  UA6ALB<br>4” – UA6AN /  UA6ANB<br>
|[[media:TRF PQL TS MEM PrimeConduit PVCFittings.pdf|5/26/09]]
|
|
|}
|}
 
{{PQLNote|Schedule 80 PVC shall only be used in above ground applications or exposed on the underside of bridge decks.}}
{{PQLReturn}}
{{PQLReturn}}


=== RMC Conduit ===
=== Schedule 40 PVC Fittings ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 777: Line 747:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Part of Atkore International
|[http://www.alliedeg.us/ Allied Tube & Conduit]
|'''[[Media:TRF PQL TS CAT AlliedTube&Conduit PVCCouplings.pdf|Standard Couplings]]:'''<br>&nbsp;1” – 59603<br>&nbsp;1 ½” – 59605<br>&nbsp;2” – 59606<br>&nbsp;3" – 59608<br>&nbsp;4" – 59610
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL TS CAT AlliedTube&Conduit 36RSpecialPlain90Elbow.pdf|Plain End]]) / (Bell End)'''<br>&nbsp;2” – 59730 / NA<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT AlliedTube&Conduit PlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT AlliedTube&Conduit BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59590 /  802754<br>&nbsp;1 ½” – 59592 / 802756<br>&nbsp;2” – 59593 /  807757<br>&nbsp;3” – 59595 / 802759<br>&nbsp;4" – 59597 / 802762<br>
'''45º Elbows:([[Media:TRF PQL TS CAT AlliedTube&Conduit PlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT AlliedTube&Conduit BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59577 /  802768<br>&nbsp;1 ½” – 59579 / 802770<br>&nbsp;2” – 59580 / 802771<br>&nbsp;3” – 59582 / 802773<br>&nbsp;4” – 59584 / 802775<br>
'''30º Elbows: ([[Media:TRF PQL TS CAT AlliedTube&Conduit PlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT AlliedTube&Conduit BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59563 /  802780<br>&nbsp;1 ½” – 59565 / 802782<br>&nbsp;2” – 59566 /  802783<br>&nbsp;3" – 59568 / 802785<br>&nbsp;4” – 59570 / 802787<br>
|[[Media:TRF PQL TS MEM AlliedTube&Conduit Sch40PVCFittings.pdf|9/3/14]]
|
|
|Allied Tube & Conduit
|-
|1” – 278895<br>1 ½” – 278911<br>2” – 278929<br>3” – 278945<br>4” – 278960
|[[media:TRF PQL TS MEM AlliedTubeConduit RMCConduit.pdf|5/5/03]]
|
|
|-
|[http://www.cantexinc.com/Products/NM_Fittings_Accessories/ Cantex]
|'''[[Media:TRF PQL TS CAT Cantex PVCFittings Coupling.pdf|Standard Couplings:]]'''<br>1” – 6141625<br>1 ½” – 6141627<br>2” – 6141628<br>3” – 6141630<br>4” - 6141632<br>
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL TS CAT Cantex PVCFittings 36RSpecialPlain90Elbow.pdf|Plain End]]) / ([[Media:TRF PQL TS CAT Cantex PVCFittings 36RSpecialBelled90Elbow.pdf|Belled End]])'''<br>2” – 5133848 / 5233848<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT Cantex PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[Media:TRF PQL TS CAT Cantex PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” – 5133825 /  5233825<br>1 ½” – 5133827 / 5233827<br>2” – 5133828 /  5233828<br>3” – 5133830 /  5233830<br>4” – 5133832 /  5233832<br>
'''45º Elbows: ([[Media:TRF PQL TS CAT Cantex PVCFittings 45ElbowPlainEnd.pdf|Plain End]] / [[Media:TRF PQL TS CAT Cantex PVCFittings 45BelledEnd.pdf|Belled End]])'''<br>1” – 5133765 / 5233765<br>1 ½” – 5133767 / 5233767<br>2” – 5133768 /  5233768<br>3” – 5133770 /  5233770<br>4” – 5133772 /  5233772<br>
'''30º  Elbows:  (Plain End / Belled End)'''<br>1” – 5133745 /  5233745<br>1 ½” – 5133747 / 5233747<br>2” – 5133748 /  [[Media:TRF PQL TS CAT Cantex PVCFittings 30BelledEnd2-4in.pdf|5233748]]<br>3” – 5133750 / [[Media:TRF PQL TS CAT Cantex PVCFittings 30BelledEnd2-4in.pdf|5233750]]<br>4” – 5133775 /  [[Media:TRF PQL TS CAT Cantex PVCFittings 30BelledEnd2-4in.pdf|5233776]]
|[[Media:TRF PQL TS MEM Cantex PVCFittings.pdf|5/5/03]]
|
|
|Sawhill Tubular Division
|-
|Steelduct<br>1” –  662535-19345-1<br>1 ½” – 662535-19347-5<br>2” – 662535-19349-9<br>3” –  662535-19351-2<br>4” – 662535-19353-6
|Part of Atkore International
|[[media:TRF PQL TS MEM SawhillTubularDivision RMCConduit.pdf|4/11/00]]
|[http://www.heritageplastics.com/products-downloads.html Heritage Plastics]
|'''[[Media:TRF PQL TS CAT HeritagePlastics PVCFittings Coupling.pdf|Standard Couplings:]]'''<br>1” – 610002<br>1 ½” – 610004<br>2” – 610005<br>3” – 610007<br>4” – 610009<br>
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 36RSpecialPlain90Elbow.pdf|Plain End]]) / [[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 36RSpecialBelled90Elbow.pdf|Belled End]])'''<br> 2” – 611353 / 611140<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” – 611002 / 611058<br>1 ½” – 611004 /611060<br>2” – 611005 / 611061<br>3” – 611007 / 611063<br>4” – 611009 / 611065<br>
'''45º Elbows: ([[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” – 611016 / 611071<br>1 ½” – 611018 / 611073<br>2” – 611019  / 611074<br>3” – 611021 / 611076<br>4” – 611023 / 611078<br>
'''30º Elbows: ([[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowPlainEnd.pdf|Plain End]] / [[Media:TRF PQL TS CAT HeritagePlastics PVCFittings 90ElbowBelledEnd.pdf|Belled End]])'''<br>1” – 611030 / 611085<br>1 ½” – 611032 / 611087<br>2” – 611033 / 611088<br>3” – 611035 / 611090<br>4” – 611037 / 611092
|[[Media:TRF PQL TS MEM HeritagePlastics PVCFittings.pdf|7/24/12]]
|
|
|-
|-
|
|
|Western Tube & Conduit Corp
|[http://www.ipexinc.com/Home.aspx?LanguageCode=en-CA IPEX / Scepter]
|1” – WTR3<br>1 ½” – WTR5<br>2” – WTR6<br>3” – WTR8<br>4” – WTR91
|[[Media:TRF PQL TS CAT IPEXScepter PVCCouplings.pdf|'''Standard Couplings:''']]<br>1” – EC20 / 077003<br>1 ½” – EC30 / 077005<br>2” – EC35 / 077006<br>3” – EC45 / 077008<br>4” – EC55 / 077010<br>
|[[media:TRF PQL TS MEM WesternTubeConduitCorp RMCConduit.pdf|5/5/03]]
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL TS CAT IPEXScepter PVCLargeRadiusElbows.pdf|Plain End / Belled End)]]'''<br>2” –  068765 / 068054<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” – EE2090 / EE2090B<br>1 ½” – EE3090 / EE3090B<br>2” – EE3590 / EE3590B<br>3” – EE4590 /  EE4590B<br>4” – EE5590 /  EE5590B<br>
'''45º Elbows: ([[Media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” – EE2045 / EE2045B<br>1 ½” – EE3045 / EE3045B<br>2” – EE3545 / EE3545B<br>3” – EE4545 / EE4545B<br>4” – EE5545 / EE5545B<br>
'''30º  Elbows:  ([[Media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” – EE2030 / NA<br>1 ½” – EE3030 / NA<br>2” – EE3530 / NA<br>3” – EE4530 / NA<br>4” – EE5530 / NA<br>
'''22.5º  Elbows:  ([[Media:TRF PQL TS CAT IPEXScepter PVCStdPlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT IPEXScepter PVCStdBellEndElbows.pdf|Belled End]])'''<br>1” – NA / NA<br>1 ½” – EE1522 / NA<br>2” – EE2022 / NA<br>3” – EE3022 / NA<br>4” – EE4022 / NA
|[[Media:TRF PQL TS MEM IPEXScepter PVCStdFittings.pdf|12/22/05]]
|
|
|-
|-  
|
|Formerly Carlon
|Wheatland Tube
|[http://www.primeconduit.com/ Prime Conduit]
|1” – 05440<br>1 ½” – 05442<br>2” – 05443<br>3” – 05445<br>4” – 05447
|'''[[Media:TRF PQL TS CAT PrimeConduit PVCCoupling.pdf|Standard Couplings:]]'''<br>1” – CP100<br>1 ½” – CP150<br>2” – CP200<br>3” – CP300<br>4” – CP400<br>
|[[media:TRF PQL TS MEM WheatlandTube RMCConduit.pdf|5/5/03]]
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>2” –  UA9FJ / UA9FJB<br>'''90º Elbows: ([[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>1” – UA9AF /  UA9AFB  <br>1 ½” – UA9AH / UA9AHB<br>2” – UA9AJ /  UA9AJB<br>3” – UA9AL /  UA9ALB<br>4” – UA9AN /  UA9ANB<br>
'''45º Elbows: ([[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>1” – UA7AF /  UA7AFB  <br>1 ½” – UA7AH / UA7AHB<br>2” – UA7AJ /  UA7AJB<br>3” – UA7AL /  UA7ALB<br>4” – UA7AN /  UA7ANB<br>
'''30º  Elbows:  ([[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|Plain End / Belled End]])'''<br>1” – UA6AF /  UA6AFB<br>1 ½” – UA6AH / UA6AHB<br>2” – UA6AJ /  UA6AJB<br>3” – UA6AL /  UA6ALB<br>4” – UA6AN /  UA6ANB<br>
|[[Media:TRF PQL TS MEM PrimeConduit PVCFittings.pdf|5/26/09]]
|
|
|}
|}
{{PQLNote|Galvanized Rigid Conduit<br>Used only for extension of existing RMC conduit


}}
=== Schedule 80 PVC Fittings ===
 
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{{PQLReturn}}
 
=== RMC Fittings ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Notes'''
Line 816: Line 807:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|Part of Atkore International
|Conduit Pipe Products
|[http://www.alliedeg.us/ Allied Tube & Conduit]
|Coupling Part Numbers<br>1 ½” – 00135<br>2” – 00136<br>3” 00138<br>4” 00140<br>90º Elbow Part Numbers<br>1 ½” – 00165<br>2” – 00166<br>3” – 00168<br>4” – 00170<br>45º Elbow Part Numbers<br>1 ½” – 00185<br>2” – 00186<br>3” – 00188<br>4” – 00190
|'''[[Media:TRF PQL TS CAT AlliedTube&Conduit Sch80Couplings.pdf|Standard Couplings]]:'''<br>&nbsp;1” – 59603<br>&nbsp;1 ½” – 59605<br>&nbsp;2” – 59606<br>&nbsp;3" – 59608<br>&nbsp;4" 59610<br>
|[[media:TRF PQL TS MEM ConduitPipeProducts RMCFittings.pdf|5/5/03]]
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL SL CAT AlliedTube&Conduit Sch80SpecialRadiusPlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL SL CAT AlliedTube&Conduit Sch80SpecialRadiusBellEndElbows.pdf|Bell End)]]'''<br>&nbsp;2” 597394 / 926011<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT AlliedTube&Conduit Sch80PlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT AlliedTube&Conduit Sch80BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59014 /  924949<br>&nbsp;1 ½” – 59016 /  NA<br>&nbsp;2” – 59017 /  924970<br>&nbsp;3” – 59019 / 924993<br>&nbsp;4” – 59021 / 925006<br>
'''45º Elbows:([[Media:TRF PQL TS CAT AlliedTube&Conduit Sch80PlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT AlliedTube&Conduit Sch80BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59002 /  NA<br>&nbsp;1 ½” – 59004 /  903486<br>&nbsp;2” – 59005 / 924967<br>&nbsp;3” – 59007 / 924990<br>&nbsp;4" – 59009 /  925006<br>
'''30º Elbows: ([[Media:TRF PQL TS CAT AlliedTube&Conduit Sch80PlainEndElbows.pdf|Plain End]] / [[Media:TRF PQL TS CAT AlliedTube&Conduit Sch80BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59066 /  NA<br>&nbsp;1 ½” – 59068 /  NA<br>&nbsp;2” – 59069 /  NA<br>&nbsp;3" – 59071 / NA<br>&nbsp;4” – 59072 /  NA<br>
|[[Media:TRF PQL TS MEM AlliedTube Sch80PVCElbows&Couplings.pdf|1/29/19]]
|
|
|-
|-
|
|
|Picoma Industries
|[http://www.cantexinc.com Cantex]
|Couplings, 90º Elbow and 45º Elbow in sizes:<br>1 ½”, 2”, 3”, 4”
|'''[[Media:TRF PQL TS CAT Cantex Couplings.pdf|Standard Couplings]]:'''<br>&nbsp;1” – 6141625<br>&nbsp;1 ½" – 6141627<br>&nbsp;2” – 6141628<br>&nbsp;3" – 6141630<br>&nbsp;4" – 6141632<br>
|[[media:TRF PQL TS MEM PicomaIndustries RMCFittings.pdf|5/5/03]]
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL TS CAT Cantex Sch8036RSpecialPain90Elbow.pdf|Plain End]] / [[Media:TRF PQL TS CAT Cantex Sch8036RSpecialBell90Elbow.pdf|Belled End]])'''<br>&nbsp;2” – 5121021 / 5121047<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT Cantex Sch80Plain90Elbow.pdf|Plain End]] / [[Media:TRF PQL TS CAT Cantex Sch80Bell90Elbow.pdf|Belled End]])'''<br>&nbsp;1” – 5121055 /  NA<br>&nbsp;1 ½” – 5121057 /  5221057<br>&nbsp;2” – 5121058 /  5221058<br>&nbsp;3” – 5121060 / 5221060<br>&nbsp;4” – 5121061 /  5221061<br>
'''45º Elbows:([[Media:TRF PQL TS CAT Cantex Sch80Plain45Elbow.pdf|Plain End]] / [[Media:TRF PQL TS CAT Cantex Sch80Bell45Elbow.pdf|Belled End]])'''<br>&nbsp;1” – 5121005 /  NA<br>&nbsp;1 ½” – 5121007 /  5221007<br>&nbsp;2” – 5121008 / 5221008<br>&nbsp;3” – 5121010 / 5221010<br>&nbsp;4” – 5121011 /  5221011<br>
'''30º Elbows: ([[Media:TRF PQL TS CAT Cantex Sch80Plain30Elbow.pdf|Plain End]] / Belled End)'''<br>&nbsp;1” – 5121002 /  NA<br>&nbsp;1 ½” – 5121850 /  NA<br>&nbsp;2” – 5121108 /  NA<br>&nbsp;3" – 5121110 / NA<br>&nbsp;4” – 5121111 /  NA<br>
'''22.5º Elbows: ([[Media:TRF PQL TS CAT Cantex Sch80Plain22.5Elbow.pdf|Plain End]] / [[Media:TRF PQL TS CAT Cantex Sch80Bell22.5Elbow.pdf|Belled End]])'''<br>&nbsp;1” – NA /  NA<br>&nbsp;1 ½” – 5136649 /  NA<br>&nbsp;2” – 5136659 /  5221052<br>&nbsp;3" – 5136679 / 5236679<br>&nbsp;4” – 5121868 /  5221868
 
|[[Media:TRF PQL TS MEM Cantex Sch80PVCElbows&Couplings.pdf|1/29/19]]
|
|
|-
|-
|
|Part of Atkore International
|Sawhill Tubular Division
|[http://www.heritageplastics.com/products-downloads.html Heritage Plastics]
|Steelduct (Right and Left Threaded)<br>Coupling Part Numbers<br>4”x4” 20997
|'''[[Media:TRF PQL TS CAT HeritagePlastics Couplings.pdf|Standard Couplings:]]'''<br>&nbsp;1” – 59603<br>&nbsp;1 ½" – 59605<br>&nbsp;2” – 59606<br>&nbsp;3” – 59608<br>&nbsp;4" – 59610<br>
|[[media:TRF PQL TS MEM SawhillTubularDivision RMCFittings Steelduct.pdf|4/10/01]]
'''90º Elbows 36” Radius for Power:<br>([[Media:TRF PQL TS CAT HeritagePlastics Sch80SpecialRadiusPlainEndElbows.pdf|Plain End]]) / ([[Media:TRF PQL TS CAT HeritagePlastics Sch80SpecialRadiusBellEndElbows.pdf|Belled End]])'''<br>&nbsp;2” – 597394 / 926011<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT HeritagePlastics Sch80PlainEndElbows.pdf|Plain End]]) / ([[Media:TRF PQL TS CAT HeritagePlastics Sch80BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” –  59014  / 924949<br>&nbsp;1 ½" – 59016 / NA<br>&nbsp;2” – 59017 /  924970<br>&nbsp;3" - 59019 / 924993<br>&nbsp;4" – 59021 /  925006<br>
'''45º Elbows: ([[Media:TRF PQL TS CAT HeritagePlastics Sch80PlainEndElbows.pdf|Plain End]]) / ([[Media:TRF PQL TS CAT HeritagePlastics Sch80BellEndElbows.pdf|Belled End]])'''<br>&nbsp;1” – 59002 /  NA<br>&nbsp;1 ½" – 59004 /  903486<br>&nbsp;2” –  59005  / 924967<br>&nbsp;3” – 59007 / 924990<br>&nbsp;4" – 59021 /  925003<br>
'''30º Elbows: ([[Media:TRF PQL TS CAT HeritagePlastics Sch80PlainEndElbows.pdf|Plain End]]) / (Belled End)'''<br>&nbsp;1” – 59066 /  NA<br>&nbsp;1 ½" – 59068 /  NA<br>&nbsp;2” –  59069  / NA<br>&nbsp;3” – 59071 / NA<br>&nbsp;4" 59072 /  NA
|[[Media:TRF PQL TS MEM HeritagePlastics Sch80PVCElbows&Couplings.pdf|1/29/19]]
|
|
|-
|-
|
|
|Sawhill Tubular Division
|[http://www.ipexna.com/usa IPEX / Scepter]
|90º Elbow Part Numbers<br>3” – 21276<br>4” 21279<br>45º Elbow Part Numbers<br>3” – 21271<br>4” 21273
|'''[[Media:TRF PQL TS CAT IPEXSceptor PVCCouplings.pdf|Standard Couplings:]]'''<br>&nbsp;1” – EC20<br>&nbsp;1 ½” – ED30<br>&nbsp;2” – EC35<br>&nbsp;3” – EC45<br>&nbsp;4" – ED55<br>
|[[media:TRF PQL TS MEM SawhillTubularDivision RMCFittings Elbow.pdf|4/11/00]]
'''90º Elbows 36” Radius for Power:<br>[[Media:TRF PQL TS CAT IPEXSceptor Sch80Special36RPlainEndElbows.pdf|(Plain End]] / Belled End)'''<br>&nbsp;2” –  068775 / NA<br>
'''90º Elbows: ([[Media:TRF PQL TS CAT IPEXSceptor Sch80PlainEndElbows.pdf|Plain End]] / Belled End)'''<br>&nbsp;1” – 80EE2090 /  NA<br>&nbsp;1 ½” – 80EE3090 /  NA<br>&nbsp;2” – 80EE3590 /  NA<br>&nbsp;3” – 80EE4590 /
NA<br>4" - 80EE5590 /  NA<br>
'''45º Elbows: ([[Media:TRF PQL TS CAT IPEXSceptor Sch80PlainEndElbows.pdf|Plain End]] / Belled End)'''<br>&nbsp;1” – 80EE2045 /  NA<br>1 ½” 80EE3045 /  NA<br>&nbsp;2” – 80EE3545 /  NA<br>&nbsp;3” – 80EE4545 /
NA<br>4" – 80EE5545 /  NA<br>
'''30º  Elbows:  ([[Media:TRF PQL TS CAT IPEXSceptor Sch80PlainEndElbows.pdf|Plain End]] / Belled End)'''<br>&nbsp;1” – 80EE2030 /  NA<br>1 ½” – 80EE3030 /  NA<br>&nbsp;2” – 80EE3530 /  NA<br>&nbsp;3” – 80EE4530 /
NA<br>4" 80EE5530 /  NA
|[[Media:TRF PQL TS MEM IPEXSceptor Sch80PVCElbows&Couplings.pdf|1/29/19]]
|
|
|-
|-
|
|
|Shamrock Conduit Products
|[http://www.primeconduit.com/# Prime Conduit]
|Coupling Part Numbers<br>1 ½” – 9001<br>2” – 0319<br>3” 0321<br>4” – 0323<br>90º Elbow Part Numbers<br>1 ½” – 7746<br>2” – 7747<br>3” – 7749<br>4” – 7751<br>45º Elbow Part Numbers<br>1 ½” – 7654<br>2” – 7655<br>3” – 7657<br>4” – 7659
|'''[[Media:TRF PQL TS CAT PrimeConduit PVCCouplings.pdf|Standard Couplings:]]'''<br>&nbsp;1” – CP100<br>&nbsp;1 ½” – CP150<br>&nbsp;2” – CP200<br>&nbsp;3" CP300<br>&nbsp;4” – CP400
|[[media:TRF PQL TS MEM ShamrockConduitProducts RMCFittings.pdf|5/5/03]]
'''90º Elbows 36” Radius for Power:<br>[[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|(Plain End / Belled End)]]'''<br>&nbsp;2” –  UB9FJ / UB9FJB<br>
'''90º Elbows: [[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|(Plain End / Belled End)]]'''<br>&nbsp;1” – UB9AF /  UB9AFB<br>&nbsp;1 ½” – UB9AH /  UB9AHB<br>&nbsp;2” – UB9AJ /  UB9AJB<br>&nbsp;3” – UB9AL /  UB9ALB<br>&nbsp;4” – UB9AN /  UB9ANB<br>
'''45º Elbows:  [[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|(Plain End / Belled End)]]'''<br>&nbsp;1” – UB7AF /  UB7AFB<br>&nbsp;1 ½” – UB7AH /  UB7AHB<br>&nbsp;2” – UB7AJ /  UB7AJB<br>&nbsp;3” – UB7AL /  UB7ALB<br>&nbsp;4” – UB7AN /  UB7ANB<br>
'''30º  Elbows:  [[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|(Plain End / Belled End)]]'''<br>&nbsp;1” – UB6AF /  UB6AFB<br>&nbsp;1 ½” – UB6AH /  UB6AHB<br>&nbsp;2” – UB6AJ /  UB6AJB<br>&nbsp;3” – UB6AL /  UB6ALB<br>&nbsp;4” – UB6AN /  UB6ANB<br>
'''22.5º  Elbows:  [[Media:TRF PQL TS CAT PrimeConduit PVCElbows.pdf|(Plain End / Belled End)]]'''<br>&nbsp;1” – UB5AF /  UB5AFB<br>&nbsp;1 ½” – UB5AH /  UB5AHB<br>&nbsp;2” – UB5AJ /  UB5AJB<br>&nbsp;3” – UB5AL /  UB5ALB<br>&nbsp;4” – UB5AN /  UB5ANB
|[[Media:TRF PQL SL MEM PrimeConduit Sch80PVCElbows&Couplings.pdf|1/29/19]]
|
|
|}
|}
{{PQLNote|Galvanized Rigid Conduit fittings<br>Used only for extension of existing RMC conduit}}
{{PQLNote|To be used with Schedule 80 PVC conduit}}
 
{{PQLReturn}}
{{PQLReturn}}


=== RMC Bushings ===
=== Bridge Expansion Couplings ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 860: Line 876:
|-
|-
|
|
|Arlington  Industries
|[http://www.alliedeg.us/index.php Allied Tube & Conduit]
|1 ½” – 454<br>2” – 455<br>3” – 457<br>4” – 459
|[[Media:TRF PQL TS CAT AlliedTube&Conduit ExpansionCoupling.pdf|1" - 789648<br>1 ½” - 789650<br>2" - 789651<br>3" - 789653<br>4" - 789655]]
|[[media:TRF PQL TS MEM ArlingtonIndustries RMCBushings.pdf|1/11/02]]
|[[Media:TRF PQL TS MEM AlliedTube&Conduit ExpansionCoupling.pdf|5/2/14]]
|
|
|-
|-
|
|
|Bridgeport
|[http://www.cantexinc.com/Products/Utility_Duct/Utility_Duct_Couplings/Expansion_Couplings_2_Piece.php Cantex]
|1 ½” – 385<br>2” – 386<br>3” – 388<br>4” – 390
|[[Media:TRF PQL TS CAT Cantex BridgeExpansionCouplings.pdf|1” – 5144033<br>1 ½” – 5144035<br>2” – 5144036<br>3” – 5144038<br>4” – 5144040]]
|[[media:TRF PQL TS MEM Bridgeport RMCBushings.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Cantex BridgeExpansionCoupling.pdf|5/5/03]]
|
|
|-
|-
|
|
|Lazy-lug
|[http://www.ipexinc.com/Home.aspx?LanguageCode=en-CA IPEX / Scepter]
|1” – GLL-3C-B<br>1 ½” – GLL-5C-B<br>2” – GLL-6C-B<br>3” – GLL-8C-B<br>4” – GLL-10C-B
|[[Media:TRF PQL TS CAT IPEXScepter ExpansionCoupling.pdf|1” – EJ20<br>1 ½” – EJ30<br>2” – EJ35<br>3” – EJ45<br>4” – EJ55]]
|[[media:TRF PQL TS MEM Lazylug RMCBushings.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM IPEXScepter ExpansionCoupling.pdf|9/26/13]]
|
|
|-
|-
|
|
|OZ-Gedney
|[http://www.primeconduit.com/ Prime Conduit]
|1” – IBC-100L-4AC<br>1 ½” – IBC-150L-4AC<br>2” – IBC-200L-4AC<br>3” – IBC-300L-4AC<br>4” – IBC-400L-4AC
|[[Media:TRF PQL TS CAT PrimeConduit ExpansionCoupling.pdf|1” – EC2PC100<br>1 ½” – EC2PC150<br>2” – EC2PC200<br>3” – EC2PC300<br>4” – EC2PC400]]
|[[media:TRF PQL TS MEM OZGedney RMCBushings.pdf|7/2/03]]
|[[Media:TRF PQL TS MEM PrimeConduit ExpansionCoupling.pdf|9/26/13]]
|
|-
|
|Regal Manufacturing
|1 ½” – 8225<br>2” – 8226<br>3” – 8228<br>4” – 8230
|[[media:TRF PQL TS MEM RegalManufacturing RMCBushings.pdf|5/5/03]]
|
|-
|
|Steel  City / Thomas &  Betts
|1 ½” – BG-805<br>2” – BG-806<br>3” – BG-808<br>4” – BH-810
|[[media:TRF PQL TS MEM SteelCity RMCBushings.pdf|5/5/03]]
|
|
|}
|}
{{PQLNote|Copper lug with insulated throat constructed of malleable  iron.<br>Threaded type}}
{{PQLReturn}}
{{PQLReturn}}


=== Bridge Expansion Couplings ===
== Controller Cabinet ==
=== ATC Pad Mount Traffic Signal Cabinet ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 909: Line 912:
|-
|-
|
|
|[http://www.alliedeg.us/index.php Allied Tube & Conduit]
|[https://www.econolite.com/ Econolite]
|[[media:TRF PQL TS CAT AlliedTube&Conduit ExpansionCoupling.pdf|1" - 789648<br>1 ½” - 789650<br>2" - 789651<br>3" - 789653<br>4" - 789655]]
|Single Wide: ATCC1201<br>Double Wide: ATCC1202
|[[media:TRF PQL TS MEM AlliedTube&Conduit ExpansionCoupling.pdf|5/2/14]]
|[[Media:TRF PQL TS MEM Econolite ATCCabinets.pdf|6/16/22]]
|
|
|-
|-
|
|
|[http://www.cantexinc.com/Products/Utility_Duct/Utility_Duct_Couplings/Expansion_Couplings_2_Piece.php Cantex]
|[https://www.mccain-inc.com/products/cabinets McCain]
|[[media:TRF PQL TS CAT Cantex BridgeExpansionCouplings.pdf|1” – 5144033<br>1 ½” – 5144035<br>2” – 5144036<br>3” – 5144038<br>4” – 5144040]]
|[[Media:TRF PQL TS CAT McCain ATCCabinet.pdf|Single Wide: 352i]]<br>[[Media:TRF PQL TS CAT McCain ATCDoubleCabinet.pdf|Double Wide: 353i]]
|[[media:TRF PQL TS MEM Cantex BridgeExpansionCoupling.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM McCain ATCCabinet.pdf|11/15/18]]
|
|[[Media:TRF PQL TS PHOT McCain ATCCabinet Front.JPG|Single Cabinet Front View]]<br>[[Media:TRF PQL TS PHOT McCain ATCCabinet CleanPowerBus.jpg|Clean Power Bus]]<br>[[Media:TRF PQL TS PHOT McCain ATCCabinet FieldInputTerminal.JPG|Field Input Terminal]]<br>[[Media:TRF PQL TS PHOT McCain ATCCabinet InputOutputAssembly.jpg|Input/Output Assembly]]<br>[[Media:TRF PQL TS PHOT McCain ATCCabinet PowerAssembly.jpg|Power Assembly]]<br>[[Media:TRF PQL TS PHOT McCain ATCCabinet RearView.JPG|Rear View]]<br>[[Media:TRF PQL TS PHOT McCain ATCCabinet SurgeProtector.jpg|Surge Protector]]
|-
|-
|
|
|[http://www.ipexinc.com/Home.aspx?LanguageCode=en-CA IPEX / Scepter]
|[https://www.mobotrex.com/ Mobotrex]
|[[media:TRF PQL TS CAT IPEXScepter ExpansionCoupling.pdf|1” – EJ20<br>1 ½” – EJ30<br>2” – EJ35<br>3” – EJ45<br>4” – EJ55]]
|352 ATC Single Wide<br>353 ATC Double Wide: Drawing - JBS2353TOP01-Rev 2
|[[media:TRF PQL TS MEM IPEXScepter ExpansionCoupling.pdf|9/26/13]]
|11/3/21
|
|[[Media:TRF PQL TS PHOT Mobotrex ATCDoubleWideCabinet Front.JPG|Double Cabinet Front View]]<br>[[Media:TRF PQL TS PHOT Mobotrex ATCDoubleWideCabinet FieldTerminal.JPG|Field Input Terminal]]<br>[[Media:TRF PQL TS PHOT Mobotrex ATCDoubleWideCabinet InputOutput.JPG|Input/Output Assembly]]<br>[[Media:TRF PQL TS PHOT Mobotrex ATCDoubleWideCabinet PowerAssembly.JPG|Power Assembly]]<br>[[Media:TRF PQL TS PHOT Mobotrex ATCDoubleWideCabinet RearView.JPG|Rear View]]<br>[[Media:TRF PQL TS PHOT Mobotrex ATCDoubleWideCabinet SurgeProtector.JPG|Surge Protector]]
|-
|}
|
{{PQLNote|Includes the following:<br>24 channel input assembly<br>16 channel output assembly<br>8" cabinet riser<br>Corbin Locks<br>MOV's for field outputs<br>Rear mounted field output terminals and field input terminal panels<br>Rear facing panel terminals for pedestrian and EVP<br>4 fans and 2 thermostats in the double cabinets and 2 fans and 1 thermostat in single cabinets}}
|[http://www.primeconduit.com/ Prime Conduit]
 
|[[media:TRF PQL TS CAT PrimeConduit ExpansionCoupling.pdf|1” – EC2PC100<br>1 ½” – EC2PC150<br>2” – EC2PC200<br>3” – EC2PC300<br>4” – EC2PC400]]
|[[media:TRF PQL TS MEM PrimeConduit ExpansionCoupling.pdf|9/26/13]]
|
|}
{{PQLReturn}}
 
== Controller Cabinet ==
=== ATC Single Pad Mount Traffic Signal Cabinet ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|<font color="red">'''For HAWK Signals Only'''</font>
|[https://www.mccain-inc.com/products/cabinets McCain]
|[[media:TRF PQL TS CAT McCain ATCCabinet.pdf|352i]]
|[[media:TRF PQL TS MEM McCain ATCCabinet.pdf|11/15/18]]
|[[media:TRF PQL TS PHOT McCain ATCCabinet Front.JPG|Front View]]
|}
{{PQLNote|Inlcudes the following:<br>Single two-door cabinet<br> 8" cabinet riser<br>MOV's for field outputs<br>Rear mounted field output terminals and field input terminal panels<br>Side panel terminals for pedestrian and EVP<br>One shelf}}
 
=== 332 Pad Mount Traffic Signal Cabinet ===
=== 332 Pad Mount Traffic Signal Cabinet ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
Line 961: Line 940:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|rowspan="3"|<font color="red">'''For Maintenance Use<br>Only/or as Specified'''</font>
|<font color="red">'''For Maintenance Use Only'''</font>
|[https://www.mccain-inc.com/ McCain]
|[https://www.mccain-inc.com/ McCain]
|Model 332 / M35378
|Model 332 / M35378
|[[media:TRF PQL TS MEM McCain PadMountTSCabinet.pdf|10/12/11]]
|[[Media:TRF PQL TS MEM McCain PadMountTSCabinet.pdf|10/12/11]]
|
|-
|[https://www.trafficware.com/ PSI/Trafficware]
|[[media:TRF PQL TS CAT PhillipsSissonInd PadMountTSCabinet.pdf|Model 332]]
|[[media:TRF PQL TS MEM PhillipsSissonInd PadMountTSCabinet.pdf|5/5/03]]
|
|
|-
|-
|[https://www.safetran-traffic.com/ Safetran]
|Model 332-OPKS
|[[media:TRF PQL TS MEM Safetran PadMountTSCabinet.pdf|5/5/03]]
|
|}
|}


=== 332 Single Input File Pad Mount Traffic Signal Cabinet ===
=== 333 Double Pad Mount Traffic Signal Cabinet ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 987: Line 957:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|<font color="red">'''For Maintenance Use<br>Only/or as Specified'''</font>
|<font color="red">'''For Maintenance Use Only'''</font>
|[https://www.mccain-inc.com/ McCain]
|[https://www.mccain-inc.com/ McCain]
|Model OP332SI w/ slide out battery drawer UPS Battery Drawer 6
|Model 333JP-OPKS
|[[media:TRF PQL TS MEM McCain SingleInputFilePadMountTSCabinet.pdf|10/12/11]]
|[[Media:TRF PQL TS MEM McCain DoublePadMountTSCabinet.pdf|6/16/10]]
|
|
|}
|}
{{PQLNote|These should be fabricated to “Overland Park Special” configurations}}


=== 333 Double Pad Mount Traffic Signal Cabinet ===
== Detection Systems ==
=== Pedestrian Pushbuttons ADA Audible ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,003: Line 975:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|rowspan="2"|<font color="red">'''For Maintenance Use<br>Only/or as Specified'''</font>
|The iNS mounting brackets are compatible with iNS or iN buttons.
|[https://www.mccain-inc.com/ McCain]
|[http://www.polara.com Polara Engineering, Inc.]
|Model 333JP-OPKS
|iNS iNavigator 3-Wire APS<br>[[Media:TRF PQL TS CAT Polara iNS3Wire 3-WirePushButtonStation.pdf|iNS33TN1-X Push Button Station w/ 9”x15” frame]]<br>[[Media:TRF PQL TS CAT Polara iNS3Wire PedHeadControlUnit.pdf|iPHCU3W Ped Head Control Unit]]<br><br>Accessories<br>[[Media:TRF PQL TS CAT Polara iNS3Wire StraightMountingExtender.pdf|iNS-EXT-LL-PC-X Straight Mounting Extender]]<br>[[Media:TRF PQL TS CAT Polara iNS3Wire AngledMountingExtender.pdf|iNS-EXTANG-LL-PC-X Angled Mounting Extender]]<br>[[Media:TRF PQL TS CAT Polara iNS3Wire CurvedMountingExtender.pdf|iNS-EXTHTRED-PC-X Curved Mounting Extender]]<br>[[Media:TRF PQL TS CAT Polara iNS3Wire DualMountsFlexible.pdf|iNSPA4x2-B Dual Mounting Bracket Flexible]]<br>[[Media:TRF PQL TS CAT Polara iNS3Wire 90DegreeAdaptor.pdf|iNS-90DEGADPTR-PC-X 90-Degree Adaptor]]<br>
|[[media:TRF PQL TS MEM McCain DoublePadMountTSCabinet.pdf|6/16/10]]
|[[Media:TRF PQL TS MEM Polara iNS3Wire 3-WirePushButtonStation.pdf|1/6/2021]]
|
|
|-
|-
|[https://www.safetran-traffic.com/ Safetran]
|The iNS 3-Wire<br>is backwards compatible<br>with the iN 3-Wire.<br>New iNS mounting brackets<br>will be required to mount an iNS button.<br><font color="red">'''For Maintenance Use<br>Only'''</font>
|Model 333SD-OPKS
|[http://www.polara.com Polara Engineering, Inc.]
|[[media:TRF PQL TS MEM Safetran DoublePadMountTSCabinet.pdf|6/16/10]]
|iN iNavigator 3-Wire APS<br>[[Media:TRF PQL TS CAT Polara iNav3Wire PushButtonStation.pdf|iN33TN1-X Push Button Station w/ 9”x15” frame]]<br><br>Accessories<br>[[Media:TRF PQL TS CAT Polara iNav2Wire StraightMountingExtender.pdf|iN-EXT-LL-PC-X Straight Mounting Extender]]<br>[[Media:TRF PQL TS CAT Polara iNav2Wire AngledMountingExtender.pdf|iN-EXTANG-LL-PC-X Angled Mounting Extender]]<br>[[Media:TRF PQL TS CAT Polara iNav2Wire CurvedMountingExtender.pdf|iN-EXTHTRED-PC-X Curved Mounting Extender]]<br>[[Media:TRF PQL TS CAT Polara iNav2Wire DualMounts.pdf|iNPBF2S-4.5-PC-X Dual Mounting Bracket]]<br>[[Media:TRF PQL TS CAT Polara iN3Wire DualMountsFlexible.pdf|iNPA4x2-B Dual Mounting Bracket Flexible]]<br>[[Media:TRF PQL TS CAT Polara iNav2Wire 90DegreeAdaptor.pdf|iN-90DEGADPTR-PC-X 90-Degree Adaptor]]<br>
|
|[[Media:TRF PQL TS MEM Polara iN3Wire 3-WirePushButtonStation.pdf|12/21/2018]]
|[[Media:TRF PQL TS PHOT Polara iNav2Wire iN23TN0-Y Front.JPG|Station Front View]]<br>[[Media:TRF PQL TS PHOT Polara iNav2Wire iN23TN0-Y Cover Removed.JPG|Station Cover Removed]]<br>
|-
|<font color="red">'''For Maintenance Use<br>Only/or as Specified'''</font>
|[http://www.polara.com Polara Engineering, Inc.]
|EZ Communicator Navigator 4-Wire APS<br>[[Media:TRF PQL TS CAT Polara APS PedButton.pdf|9”x15” frame – EN43TN1-PY (std pole)]]<br>[[Media:TRF PQL TS CAT Polara APS PowerUnit.pdf|PHCU4W - Included Power Unit]]<br>[[Media:TRF PQL TS CAT Polara APS PoleAdapter.pdf|NPA4X2-y (adapter for pedestal pole)]]<br>[[Media:TRF PQL TS CAT Polara APS SignOptions.pdf|800H-84 - Sign Option]]<br>[[Media:TRF PQL TS CAT Polara APS SoundBaffle.pdf|Optional Sound Baffle: ENAV-SB]]<br>[[Media:TRF PQL TS CAT Polara APS FrameExtender.pdf|Optional Frame Extender: 6" - PBFE-06 or 12" PBFE-12]]
|[[Media:TRF PQL TS MEM Polara APS PedButton.pdf|1/23/13]]
|[[Media:TRF PQL TS PHOT Polara APS Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Polara APS Button.JPG|Button]]<br>[[Media:TRF PQL TS PHOT Polara APS Back.JPG|Back View]]
|-
|}
|}
{{PQLNote|These should be fabricated to “Overland Park Special” configurations}}
{{PQLNote|Red LED indicator<br>Auto volume adjustment for ambient noise levels<br>LL &#x003D; Length of Extension: 06 for 6" or 12 for 12"<br>X &#x003D; Color: B for Black or Y for Yellow.<br>Audible locator tones shall be set to be audible 6 to 12 feet from the push button, or to the building line, whichever is less.<br>A percussive tone is required where an APS is provided at a signle crossing or where two APS are 10' or more from each other at a corner.<br>Custom Message (Recorded at Factory w/ electronic copy sent to City) where the APS are less than 10' apart.<br><br>For standard signal poles, the color of the frame, bracket, and adapter, if used, shall be powder coated yellow.  The extender shall remain galvanized with no color.<br>For decorative signal poles, the color of the extender, frame, bracket, and adapter, if used, shall be powder coated black.}}


=== Hybrid Double Pad Mount Traffic Signal Cabinet ===
=== Pedestrian Pushbuttons ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,025: Line 1,005:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|<font color="red">'''For Maintenance Use Only/or<br>as Specified'''</font>
|[http://www.polara.com/bdspecifications.php Polara Engineering, Inc.]
|[[Media:TRF PQL TS CAT PolaraEngineeringInc PedestrianPushbuttons.pdf|Bulldog Series<br>Push Button Assembly: BDSP-010-X]]<br>[[Media:TRF PQL TS CAT PolaraEngineeringInc PedestrianPushbuttonPoleMountAdaptor.pdf|Pole Mount Adaptor: BDPM3-X]]<br><br><font color="red">'''Accessories For Maintenance Use Only/or as Specified'''</font><br>
[[Media:TRF PQL TS CAT Polara Bulldog PBF2C REV-A.pdf|Push Button Frame 2C with 9"x15" Plate Adapter: PBF2C-9x15-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog iNSStraightMountingExtender.pdf|Straight Mounting Extender: iNS-EXT-LL-PC-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog iNSAngledMountingExtender.pdf|Angled Mounting Extender: iNS-EXTANG-LL-PC-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog iNSCurvedMountingExtender.pdf|Curved Mounting Extender: iNS-EXTHTRED-PC-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog iNS90DegreeAdaptor.pdf|90-Degree Adaptor: iNS-90DEGADPTR-PC-X]]<br>
<br>Approved for use, but no longer being manufactured as of January 2021:<br>
[[Media:TRF PQL TS CAT Polara Bulldog StraightMountingExtender.pdf|Straight Mounting Extender: iN-EXT-LL-PC-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog AngledMountingExtender.pdf|Angled Mounting Extender: iN-EXTANG-LL-PC-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog CurvedMountingExtender.pdf|Curved Mounting Extender: iN-EXTHTRED-PC-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog DualMounts.pdf|Dual Mounting Bracket: iNPBF2S-4.5-PC-X]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog DualMountsFlexible.pdf|Dual Mounting Bracket Flexible: iNPA4x2-B]]<br>
[[Media:TRF PQL TS CAT Polara Bulldog 90DegreeAdaptor.pdf|90-Degree Adaptor: iN-90DEGADPTR-PC-X]]<br>
|[[Media:TRF PQL TS MEM PolaraEngineeringInc PedestrianPushbuttons.pdf|1/26/15]]
|
|
|[http://safetran-traffic.com/index.php/products/cabinets/ Safetran]
|[[media:TRF PQL TS CAT Safetran HybridDoublePadMountTSCabinet.pdf|Model 333SD Hybrid-OPKS<br>STCAB2663-L w/Rev C – Std Brushed Alum.]]<br>[[media:TRF PQL TS CAT Safetran HybridDoublePadMountTSCabinet Riser.pdf|8” Base Adapter Riser:<br> Drawing No. 025557D333-00 w/Rev C]]
|[[media:TRF PQL TS MEM Safetran HybridDoublePadMountTSCabinet.pdf|10/6/11]]
|[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet FieldTerminals.JPG|Field Terminal Panel]]<br>[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet OutputLoadbay.JPG|Output Loadbay]]<br>[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet PowerPanelFront.JPG|Power Panel Front]]<br>[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet PowerPanelBack.JPG|Power Panel Back]]<br>[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet DetectorInterface.JPG|Detector Interface Panel]]<br>[[media:TRF PQL TS PHOT Safetran HybridDoublePadMountTSCabinet Fans.JPG|Cabinet Fans]]
|}
|}
{{PQLNote|Reliance Controls Corp (30 A, 4-prong) External Generator Receptacle if specified}}
{{PQLNote|Yellow body with sound on actuation<br>'''NO LED Flash'''<br>LL &#x003D; Length of Extension: 06 for 6" or 12 for 12"<br>X &#x003D; Color: B for Black or Y for Yellow.<br><br>For standard signal poles, the color of the frame, bracket, and adapter, if used, shall be powder coated yellow.  The extender shall remain galvanized with no color.<br>For decorative signal poles, the color of the extender, frame, bracket, and adapter, if used, shall be powder coated black.
}}


=== Hybrid Single Stretch Pad Mount Traffic Signal Cabinet ===
=== Emergency Vehicle Pre-empt (EVP) Detectors ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,043: Line 1,036:
|-
|-
|
|
|[http://safetran-traffic.com/index.php/products/cabinets/ Safetran]
|[http://www.gtt.com/ Global Traffic Technologies]
|Model 332 Stretch-OPKS<br>8" Base Adapter Riser
|[[Media:TRF PQL TS CAT GTT EVPDetector.pdf|Model 721]]
|
|[[Media:TRF PQL TS MEM GTT EVPDetector.pdf|2/218/08]]
|
|[[Media:TRF PQL TS PHOT GTT EVPDetector Side.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT GTT EVPDetector CableTerminal.JPG|Cable Terminal]]
|}
|}
{{PQLNote|Reliance Controls Corp (30 A, 4-prong) External Generator Receptacle if specified}}
{{PQLNote|Two Direction Single Channel}}


=== 334 Pad Mount DMS Sign Cabinet ===
=== Pre-formed Detector Loop ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,060: Line 1,053:
|-
|-
|
|
|[http://safetran-traffic.com/index.php/products/cabinets/ Safetran]
|[http://neverfailloops.com/ Never-Fail Loop Systems]
|Model 334-OPKS
|[[Media:TRF PQL TS CAT NeverFailLoopSystem PreformedLoopDetectorsModelA.pdf|Model A]] – in or under asphalt<br>[[Media:TRF PQL TS CAT NeverFailLoopSystem PreformedLoopDetectorsModelC.pdf|Model C]] – in concrete or bridge decks
|[[media:TRF PQL TS MEM Safetran PadMountDMSSignCabinet.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM NeverFailLoopSystem PreformedLoopDetectors.pdf|6/6/00]]
|
|-
|
|[http://www.patriotdetection.com/index.php Patriot Detection]
|[[Media:TRF PQL TS CAT PatriotDetection Pre-formedLoops.pdf|Model CG16MM]]
|[[Media:TRF PQL TS MEM PatriotDetection Pre-formedLoops.pdf|9/1/15]]
|
|-
|Purchased by EDI
|[https://www.editraffic.com/brands?cat=load-switches-flashers Reno]
|[[Media:TRF PQL TS CAT Reno PreformedDetectorLoop.pdf|Rectangular Loop: Model PLH-XX-YY<br>Quadrupole Loop: Model PLH-XX-YY-ZZ]]
|[[Media:TRF PQL TS MEM Reno PreformedDetectorLoop.pdf|7/7/16]]
|
|
|-
|}
|}
{{PQLReturn}}


== Detection Systems ==
=== Advance Radar Detectors ===
=== Microloop Probes ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,077: Line 1,081:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Global Traffic Technologies bought out 3M
|
|[http://www.gtt.com/ Global Traffic Technologies<br>/ 3M / Canoga]
|[http://www.wavetronix.com/en Wavetronix]
|Model 701 w/40004<br>Micro loop Cable
|[[Media:TRF PQL TS CAT Wavetronix AdvanceDetector.pdf|Model WX-SS-200V SmartSensor Advance Unit]]<br>SDLC Cabinet Interface Device<br>[[Media:TRF PQL TS CAT Wavetronix 6-PortSDLCInterface.pdf|6 Terminal Ports: Arc6 102-0594 (WX-500-0417)]]<br>Includes [[media:TRF PQL TS CAT Wavetronix SmartSensorSurgeCard.pdf|Surge Card: 102-0562 (WX-500-0381)]]
|[[media:TRF PQL TS MEM GTT MicroloopProbes.pdf|2/18/08]]
|[[Media:TRF PQL TS MEM Wavetronix AdvanceDetector.pdf|1/10/11]]
|
|
|}
|}
{{PQLNote|Include the SDLC Cabinet Interface Module}}
{{PQLReturn}}


=== Non-Invasive Vehicle Detectors Probes ===
=== Presence Radar Detectors ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,093: Line 1,099:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Global Traffic Technologies bought out 3M
|[http://www.gtt.com/canoga-traffic-sensing/ Global Traffic Technologies<br>/ 3M]
|[[media:TRF PQL TS CAT GTT NonInvasiveVehicleDetectorProbes.pdf|Model 702 Probes and Carriers<br>Model 702 Installation Kit<br>Canoga C800 Interface<br>Scotchcast 3832 Splice Kit]]
|[[media:TRF PQL TS MEM GTT NonInvasiveVehicleDetectorProbes.pdf|2/18/08]]
|
|
|[https://www.iteris.com/ Iteris]
|<u>4 Approaches with Presence Detection Only</u><br>[[Media:TRF PQL TS CAT Iteris RadarDetectionSystem.pdf|Detection System: RAD-SYS-4-BH-SM-TS2]]<br>Includes CCU, 4 Sensors, Power Supply and Surge Protection
<u>Individual Parts:</u><br>Presence Detector Sensor: RAD-SENSOR-BH-PAK<br>CCU: RAD-CCU-SM4-TS2-PAK<br>Surge Protection Device: ASCO - HVCP-48-4RJ45
<br>[[Media:TRF PQL TS CAT Iteris AdvanceRadarDetection.pdf|Presence Plus Advance Detector Sensor: RADPL-SENSOR-BH-PAK]]
<br><u>Mounting Brackets:</u><br>[[Media:TRF PQL TS CAT Iteris SensorMountingBracket.pdf|CAMBRKT4]]
|[[Media:TRF PQL TS MEM Iteris RadarDetectionSystem.pdf|3/11/21]]
|[[Media:TRF PQL TS PHOT Iteris RadarDetectionSystem CCU.JPG|CCU]]<br>[[Media:TRF PQL TS PHOT Iteris RadarDetectionSystem CCU Side.JPG|CCU Side]]<br>[[Media:TRF PQL TS PHOT Iteris RadarDetectionSystem PowerSupply.JPG|Power Supply]]<br>[[Media:TRF PQL TS PHOT Iteris RadarDetectionSystem PowerSupply Side.JPG|Power Supply Side]]<br>[[Media:TRF PQL TS PHOT Iteris RadarDetectionSystem PowerSupply SurgeProtection.JPG|Surge Protector]]<br>[[Media:TRF PQL TS PHOT Iteris RadarDetectionSystem Bracket.JPG|Bracket]]
|-
|
|[http://www.wavetronix.com/en Wavetronix]
|[[Media:TRF PQL TS CAT Wavetronix PresenceRadarDetector.pdf|Model WX-SS-225 SmartSensor Matrix Presence Unit]]<br>SDLC Cabinet Interface Device<br>[[Media:TRF PQL TS CAT Wavetronix 6-PortSDLCInterface.pdf|6 Terminal Ports: Arc6 102-0594 (WX-500-0417)]]<br>Includes [[media:TRF PQL TS CAT Wavetronix SmartSensorSurgeCard.pdf|Surge Card: 102-0562 (WX-500-0381)]]
|[[Media:TRF PQL TS MEM Wavetronix PresenceRadarDetector.pdf|5/30/13]]
|[[media:TRF PQL TS PHOT Wavetronix ARC6-Terminal Port SDLCInterfaceModule Front.JPG|SDLC Interface Front View]]<br>[[media:TRF PQL TS PHOT Wavetronix ARC6-Terminal Port SDLCInterfaceModule Back.JPG|SDLC Interface Back View]]<br>[[media:TRF PQL TS PHOT Wavetronix ARC6-Terminal Port SDLCInterfaceModule.JPG|SDLC Interface Iso View]]<br>[[media:TRF PQL TS PHOT Wavetronix ARC6-Terminal Port SDLCInterfaceModule SurgeCard.JPG|SDLC Interface Surge Protector Card]]<br>[[Media:TRF PQL TS PHOT Wavetronix PresenceRadarDetector CablePort.JPG|Sensor Cable Ports]]<br>[[Media:TRF PQL TS PHOT Wavetronix SDLCInterfaceModule Wire Plug.JPG|SDLC Module Wire Plug]]
|}
|}
{{PQLNote|<u>For Wavetronix:</u><br>Include the SDLC Interface Module}}


=== Pedestrian Pushbuttons ADA Audible ===
=== Vehicle Detectors (Loops) ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,109: Line 1,125:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Global Traffic Technologies<br>bought out 3M
|[http://www.gtt.com/canoga-traffic-sensing/ Global Traffic Technologies<br>/ 3M / Canoga]
|[[Media:TRF PQL TS CAT GTT VehicleDetectors.pdf|Model C922 – Two Channel<br>Model C924 – Four Channel]]
|[[Media:TRF PQL TS MEM GTT VehicleDetectors.pdf|2/18/08]]
|
|
|[http://www.polara.com Polara Engineering, Inc.]
|-
|iNavigator 3-Wire APS<br>[[media:TRF_PQL_TS_CAT_Polara_iNav3Wire_PushButtonStation.pdf|iN33TN1-X Push Button Station w/ 9”x15” frame]]<br><br>Accessories<br>[[media:TRF_PQL_TS_CAT_Polara_iNav2Wire_StraightMountingExtender.pdf|iN-EXT-LL-PC-X Straight Mounting Extender]]<br>[[media:TRF_PQL_TS_CAT_Polara_iNav2Wire_AngledMountingExtender.pdf|iN-EXTANG-LL-PC-X Angled Mounting Extender]]<br>[[media:TRF_PQL_TS_CAT_Polara_iNav2Wire_CurvedMountingExtender.pdf|iN-EXTHTRED-PC-X Curved Mounting Extender]]<br>[[media:TRF_PQL_TS_CAT_Polara_iNav2Wire_DualMounts.pdf|iNPBF2S-4.5-PC-X Dual Mounting Bracket]]<br>[[media:TRF_PQL_TS_CAT_Polara_iNav2Wire_90DegreeAdaptor.pdf|iN-90DEGADPTR-PC-X 90-Degree Adaptor]]<br>
|Purchased by EDI
|[http://www.renoae.com/Category/traffic/1 Reno]
|[[Media:TRF PQL TS CAT Reno VehicleDetectors2Ch.pdf|Model  C-1200-SS  Series – Two Channel]]<br>[[Media:TRF PQL TS CAT Reno VehicleDetectors4Ch.pdf|Model E-1200-SS Series – Four Channel]]
|[[Media:TRF PQL TS MEM Reno VehicleDetectors.pdf|2/10/12]]
|
|
|[[media:TRF_PQL_TS_PHOT_Polara_iNav2Wire_iN23TN0-Y Front.JPG|Station Front View]]<br>[[media:TRF_PQL_TS_PHOT_Polara_iNav2Wire_iN23TN0-Y Cover Removed.JPG|Station Cover Removed]]<br>
|-
|<font color="red">'''For Maintenance Use<br>Only/or as Specified'''</font>
|[http://www.polara.com Polara Engineering, Inc.]
|EZ Communicator Navigator 4-Wire APS<br>[[media:TRF PQL TS CAT Polara APS PedButton.pdf|9”x15” frame – EN43TN1-PY (std pole)]]<br>[[media:TRF PQL TS CAT Polara APS PowerUnit.pdf|PHCU4W - Included Power Unit]]<br>[[media:TRF PQL TS CAT Polara APS PoleAdapter.pdf|NPA4X2-y (adapter for pedestal pole)]]<br>[[media:TRF PQL TS CAT Polara APS SignOptions.pdf|800H-84 - Sign Option]]<br>[[media:TRF PQL TS CAT Polara APS SoundBaffle.pdf|Optional Sound Baffle: ENAV-SB]]<br>[[media:TRF PQL TS CAT Polara APS FrameExtender.pdf|Optional Frame Extender: 6" - PBFE-06 or 12" PBFE-12]]
|[[media:TRF PQL TS MEM Polara APS PedButton.pdf|1/23/13]]
|[[media:TRF PQL TS PHOT Polara APS Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Polara APS Button.JPG|Button]]<br>[[media:TRF PQL TS PHOT Polara APS Back.JPG|Back View]]
|-
|}
|}
{{PQLNote|Red LED indicator<br>Audible locator<br>Auto volume adjustment for ambient noise levels<br>Custom Message (Recorded at Factory w/ electronic copy sent to City)<br>LL &#x003D; Length of Extension: 06 for 6" or 12 for 12"<br>X &#x003D; Color: B for Black or Y for Yellow.<br><br>The color of the extender, frame, bracket, and adapter, if used, shall be powder coated yellow for standard signal poles, and powder coated black for decorative signal poles.}}
{{PQLNote|It shall have TS2 status output available}}


=== Pedestrian Pushbuttons ===
=== Video Detection Systems ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,132: Line 1,147:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Comments'''
|-
|-
|<font color="red">'''Used for Maintenance  Replacements Only'''
|[http://www.econolite.com/index.php/products/detection/ Econolite/Autoscope Encore MVP]
|Image Sensor: AENCORENP<br>Interface Panel: ATIP1<br>Access Point: ATAPE<br>Interface Cable Kit: ASTCBL10<br>SDLC Cable Harness: 33550G5
|9/11/13
|
|
 
|Easy-Lock Harting Connector<br>On-Board Ethernet Port<br>SDLC Cable Harness for TS-2 Comm to ASC/3 – Rack Mount Controller
|[http://www.polara.com/bdspecifications.php Polara Engineering, Inc.]
|-
|[[media:TRF PQL TS CAT PolaraEngineeringInc PedestrianPushbuttons.pdf|Bulldog Series<br>Push Button Assembly: BDSP-010-X]]<br>[[media:TRF PQL TS CAT PolaraEngineeringInc PedestrianPushbuttonPoleMountAdaptor.pdf|Pole Mount Adaptor: BDPM3-X]]<br><br><font color="red">'''Accessories For Maintenance Use Only/or as Specified'''</font><br>[[media:TRF_PQL_TS_CAT_Polara_Bulldog_PBF2_REV-A.pdf|Push Button Frame 2 with 9"x15" Plate Adapter: PBF2-9x15-PC-X]]<br>[[media:TRF_PQL_TS_CAT_Polara_Bulldog_StraightMountingExtender.pdf|Straight Mounting Extender: iN-EXT-LL-PC-X]]<br>[[media:TRF_PQL_TS_CAT_Polara_Bulldog_AngledMountingExtender.pdf|Angled Mounting Extender: iN-EXTANG-LL-PC-X]]<br>[[media:TRF_PQL_TS_CAT_Polara_Bulldog_CurvedMountingExtender.pdf|Curved Mounting Extender: iN-EXTHTRED-PC-X]]<br>[[media:TRF_PQL_TS_CAT_Polara_Bulldog_DualMounts.pdf|Dual Mounting Bracket: iNPBF2S-4.5-PC-X]]<br>[[media:TRF_PQL_TS_CAT_Polara_Bulldog_90DegreeAdaptor.pdf|90-Degree Adaptor: iN-90DEGADPTR-PC-X]]<br>
|<font color="red">'''Used for Maintenance  Replacements Only'''
|[[media:TRF PQL TS MEM PolaraEngineeringInc PedestrianPushbuttons.pdf|1/26/15]]
|[http://www.econolite.com/index.php/products/detection/ Econolite/Autoscope Terra Rack Vision]
|
|AIS Image Sensor: AIS4HCRZOOMU0S<br>Camera Interface Panel: AIPx<br>Coaxial Jumper Cable: RG59<br>Processor Card: ARVTERRA1E<br>SDLC Cable Harness: 33550G5
|}
|5/17/07
{{PQLNote|Yellow body with sound on actuation<br>'''NO LED Flash'''<br>LL &#x003D; Length of Extension: 06 for 6" or 12 for 12"<br>X &#x003D; Color: B for Black or Y for Yellow.<br><br>The color of the extender, frame, bracket, and adapter, if used, shall be powder coated yellow for standard signal poles, and powder coated black for decorative signal poles.}}
|
 
|Easy-Lock Harting Connector<br>x = number of cameras to be connected to the  interface panel (1 to 6)<br>On-Board Ethernet Port
=== Emergency Vehicle Pre-empt (EVP) Detectors ===
|-
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|<font color="red">'''Used for Maintenance Replacements Only'''
|+
|[https://gridsmart.com/ Gridsmart]
| align="center" style="background:#f0f0f0;"|'''Notes'''
|[[Media:TRF PQL TS CAT Gridsmart FisheyeCameraAssembly.pdf|Fisheye Camera Assembly: GS3-SMK]]<br>[[Media:TRF PQL TS CAT Gridsmart Processor.pdf|Processor: GS-3-GS2]]<br>[[Media:TRF PQL TS CAT Gridsmart FisheyeCamera.pdf|Fisheye Camera Replacement Only: GS-3-CAM]]<br>[[Media:TRF PQL TS CAT Gridsmart MountingBracket.pdf|Mounting Bracket: GS-3-CBL]]
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
|[[Media:TRF PQL TS TS CAT Gridsmart SDLCCable.pdf|5/20/20]]
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
|[[Media:TRF PQL TS PHOT Gridsmart VideoDetectionSystem CameraSideView.JPG|Fisheye Camera Side View]]<br>[[Media:TRF PQL TS PHOT Gridsmart VideoDetectionSystem PoleAssembly.JPG|Pole Assembly]]<br>[[Media:TRF PQL TS PHOT Gridsmart VideoDetectionSystem CameraConnection.JPG|Camera Mount]]<br>[[Media:TRF PQL TS PHOT Gridsmart VideoDetectionSystem JunctionBoxInterior.JPG|Junction Box]]<br>[[Media:TRF PQL TS PHOT Gridsmart VideoDetectionSystem ProcessorFrontClosed.JPG|Processor]]<br>[[Media:TRF PQL TS PHOT Gridsmart VideoDetectionSystem RJ45Connector.JPG|RJ-45 Connector]]<br>[[Media:TRF PQL TS PHOT Gridsmart VideoDetectionSystem CableHarnessEnd.JPG|Cable Harness]]
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
|One CPU handles 1 fisheye camera and up to 3 traditional cameras or 2 fisheye cameras
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|<font color="red">'''Used for Maintenance Replacements Only'''
|[http://itsplus3.com/ ITS PLUS<sup>3</sup>, Inc.]
|[[Media:TRF PQL TS CAT ITSPlus VideoDetCamera.pdf|Advanced VIVDS Camera: ITSP-PM120C]]<br>
[[Media:TRF PQL TS CAT ITSPlus DetCard.pdf|Dual Channel VIVDS Card w/ Ethernet: ITSP-V200E]]<br>
[[Media:TRF PQL TS CAT ITSPlus SurgeSuppressionPanel.pdf|4 Way Coax Surge Suppression Panel: ITSP-SSP-4]]<br>
[[Media:TRF PQL TS CAT ITSPlus SDLCinterface.pdf|SDLC Module: ITSP-SDLC]]<br>
[[Media:TRF PQL TS CAT Remee VideoDetCable.pdf|Siamese Coax/Power Cable: ITS-Cable]]
|[[Media:TRF PQL TS MEM ITSPlus VideoDetectionSystem.pdf|1/27/17]]
|[[Media:TRF PQL TS PHOT ITSPlus Camera.JPG|Camera Front]]<br>[[Media:TRF PQL TS PHOT ITSPlus DetectionCard Front.JPG|Detection Card]]
|
|
|[http://www.gtt.com/ Global Traffic Technologies]
|-
|[[media:TRF PQL TS CAT GTT EVPDetector.pdf|Model 721]]
|[[media:TRF PQL TS MEM GTT EVPDetector.pdf|2/218/08]]
|[[media:TRF PQL TS PHOT GTT EVPDetector Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT GTT EVPDetector CableTerminal.JPG|Cable Terminal]]
|}
|}
{{PQLNote|Two Direction Single Channel}}
{{PQLReturn}}


=== Pre-formed Detector Loop ===
== Grounding Equipment ==
=== Ground Rod ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,169: Line 1,196:
|-
|-
|
|
|[http://www.loopspecialists.com/ Never-Fail Loop Systems]
|[http://www.erico.com/products/copper-bonded.asp Erico Inc.]
|[[media:TRF PQL TS CAT NeverFailLoopSystem PreformedLoopDetectorsModelA.pdf|Model A]] – in or under asphalt<br>[[media:TRF PQL TS CAT NeverFailLoopSystem PreformedLoopDetectorsModelC.pdf|Model C]] – in concrete or bridge decks
|[[Media:TRF PQL TS CAT Erico-Eritech Groundrod.pdf|5/8” x 8’-0” Cat. No. 615880<br>5/8” x 10’-0” Cat. No. 615800]]
|[[media:TRF PQL TS MEM NeverFailLoopSystem PreformedLoopDetectors.pdf|6/6/00]]
|[[Media:TRF PQL TS MEM EricoEritech GroundRod.pdf|2/27/02]]
|
|
|-
|-
|
|
|[http://www.patriotdetection.com/index.php Patriot Detection]
|[https://galvanelectrical.com/ Galvan Industries]
|[[media:TRF PQL TS CAT PatriotDetection Pre-formedLoops.pdf|Model CG16MM]]
|[[Media:TRF PQL TS CAT Galvan GroundRod.pdf|5/8" x 8'-0" Cat. No. 6258<br>5/8" x 10'-0: Cat. No. 6260]]
|[[media:TRF PQL TS MEM PatriotDetection Pre-formedLoops.pdf|9/1/15]]
|[[Media:TRF PQL TS MEM Galvan GroundRod.pdf|12/20/13]]
|
|
|-
|-
|
|
|[http://www.renoae.com/product/access/88/26 Reno]
|[http://www.hubbellpowersystems.com/pole-line/grounding/copper/ Hubbell]
|[[media:TRF PQL TS CAT Reno PreformedDetectorLoop.pdf|Rectangular Loop: Model PLH-XX-YY<br>Quadrupole Loop: Model PLH-XX-YY-ZZ]]
|[[Media:TRF PQL TS CAT ChanceHubbell GroundRod.pdf|5/8" x 8’-0” Cat. No. C615880<br>5/8” x 10’-0” Cat No. C635800]]
|[[media:TRF PQL TS MEM Reno PreformedDetectorLoop.pdf|7/7/16]]
|[[Media:TRF PQL TS MEM ChanceHubbell GroundRod.pdf|4/24/12]]
|
|
|-
|-
|}
|
|[http://www.tnb.com/pub/index.php Thomas & Betts]
|[[Media:TRF PQL TS CAT Thomas&Betts Groundrod.pdf|5/8” x 8’-0” Cat. No. 6258<br>5/8” x 10’-0” Cat No. 6260]]
|[[Media:TRF PQL TS MEM Thomas&Betts GroundRod.pdf|5/5/03]]
|
|-
|}
{{PQLNote|5/8” x 10’-0” long at poles and controller cabinet<br>5/8” x 8’-0” long at service boxes<br>Copper clad steel core<br>UL listed}}


=== Advance Radar Detectors ===
=== Ground Rod Clamp ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,198: Line 1,232:
|-
|-
|
|
|[http://www.wavetronix.com/en Wavetronix]
|[http://www.burndy.com/ Burndy]
|[[media:TRF PQL TS CAT Wavetronix AdvanceDetector.pdf|Model WX-SS-200V SmartSensor Advance Unit]]<br>SDLC Cabinet Interface Device<br>[[media:TRF PQL TS CAT Wavetronix 4-PortSDLCInterface.pdf|4 Terminal Ports: 102-0416 (WX-CLK-650)]]<br>[[media:TRF PQL TS CAT Wavetronix 6-PortSDLCInterface.pdf|6 Terminal Ports: 102-0451 (WX-CLK-656)]]
|[[Media:TRF PQL TS CAT Burndy GroundRodClamp.pdf|GRC58 – 5/8”]]
|[[media:TRF PQL TS MEM Wavetronix AdvanceDetector.pdf|1/10/11]]
|[[Media:TRF PQL TS MEM Burndy GroundRodClamp.pdf|2/27/02]]
|[[media:TRF PQL TS PHOT Wavetronix SDLCInterfaceModule Wire Plug.JPG|SDLC Module Wire Plug]]<br>4-Terminal Port SDLC Module<br>[[media:TRF PQL TS PHOT Wavetronix 4-Terminal Port SDLCInterfaceModule Front.JPG|SDLC Module Front View]]<br>[[media:TRF PQL TS PHOT Wavetronix 4-Terminal Port SDLCInterfaceModule Back.JPG|SDLC Module Back View]]<br>[[media:TRF PQL TS PHOT Wavetronix 4-Terminal Port SDLCInterfaceModule Side.JPG|SDLC Module Side View]]<br>6-Terminal Port SDLC Module<br>[[media:TRF PQL TS PHOT Wavetronix 6-Terminal Port SDLCInterfaceModule Front.JPG|SDLC Module Front View]]<br>[[media:TRF PQL TS PHOT Wavetronix 6-Terminal Port SDLCInterfaceModule Back.JPG|SDLC Module Back View]]
|[[Media:TRF PQL TS PHOT Burndy GroundRodClamp.JPG|Clamp]]
|-
|
|[http://www.erico.com/products/RodAccessories.asp Erico Inc.]
|[[Media:TRF PQL TS CAT Erico-Eritech GroundRodClamp.pdf|HDC58 – 5/8”]]
|[[Media:TRF PQL TS MEM EricoEritech GroundRodClamp.pdf|12/1/05]]
|
|-
|
|[https://galvanelectrical.com/ Galvan Industries]
|[[Media:TRF PQL TS CAT Galvan GroundRodClamp.pdf|SRC – 5/8”]]
|[[Media:TRF PQL TS MEM Galvan GroundRodClamp.pdf|12/20/13]]
|
|-
|
|[http://www.tnb.com/pub/en/node/2 Thomas & Betts]
|[[Media:TRF PQL TS CAT ThomasBetts GroundRodClamp.pdf|JAB58H - 5/8"]]
|[[Media:TRF PQL TS MEM ThomasBetts GroundRodClamps.pdf|5/5/03]]
|
|}
|}
{{PQLNote|Include the SDLC Cabinet Interface Module<br>Select appropriate SDLC Cabinet Interface Module for 4 or 6 sensors}}
{{PQLNote|Hex head set screw<br>Copper alloy<br>Long bearing surface<br>UL listed}}
 
{{PQLReturn}}
{{PQLReturn}}
 
== Junction and Service Boxes ==
=== Presence Radar Detectors ===
=== Type 1 Junction Box ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,216: Line 1,269:
|-
|-
|
|
|[http://www.wavetronix.com/en Wavetronix]
|[http://armorcastprod.com Armorcast]
|[[media:TRF PQL TS CAT Wavetronix PresenceRadarDetector.pdf|Model WX-SS-225 SmartSensor Matrix Presence Unit]]<br>SDLC Cabinet Interface Device<br>[[media:TRF PQL TS CAT Wavetronix 4-PortSDLCInterface.pdf|4 Terminal Ports: 102-0416 (WX-CLK-650)]]<br>[[media:TRF PQL TS CAT Wavetronix 6-PortSDLCInterface.pdf|6 Terminal Ports: 102-0451 (WX-CLK-656)]]
|[[Media:TRF PQL TS CAT Armorcast Type1JunctionBox.pdf|A6001423TA – Assembly<br>A6001422T – Cover only<br>A6001423 – Box only]]
|[[media:TRF PQL TS MEM Wavetronix PresenceRadarDetector.pdf|5/30/13]]
|[[Media:TRF PQL TS MEM Armorcast Type1JunctionBox.pdf|1/11/01]]
|[[media:TRF PQL TS PHOT Wavetronix PresenceRadarDetector Front.JPG|Sensor Front View]]<br>[[media:TRF PQL TS PHOT Wavetronix PresenceRadarDetector Back.JPG|Sensor Back View]]<br>[[media:TRF PQL TS PHOT Wavetronix PresenceRadarDetector Top.JPG|Sensor Top View]]<br>[[media:TRF PQL TS PHOT Wavetronix PresenceRadarDetector Bottom.JPG|Sensor Bottom View]]<br>[[media:TRF PQL TS PHOT Wavetronix PresenceRadarDetector CablePort.JPG|Sensor Cable Ports]]<br>[[media:TRF PQL TS PHOT Wavetronix SDLCInterfaceModule Wire Plug.JPG|SDLC Module Wire Plug]]<br>4-Terminal Port SDLC Module<br>[[media:TRF PQL TS PHOT Wavetronix 4-Terminal Port SDLCInterfaceModule Front.JPG|SDLC Module Front View]]<br>[[media:TRF PQL TS PHOT Wavetronix 4-Terminal Port SDLCInterfaceModule Back.JPG|SDLC Module Back View]]<br>[[media:TRF PQL TS PHOT Wavetronix 4-Terminal Port SDLCInterfaceModule Side.JPG|SDLC Module Side View]]<br>6-Terminal Port SDLC Module<br>[[media:TRF PQL TS PHOT Wavetronix 6-Terminal Port SDLCInterfaceModule Front.JPG|SDLC Module Front View]]<br>[[media:TRF PQL TS PHOT Wavetronix 6-Terminal Port SDLCInterfaceModule Back.JPG|SDLC Module Back View]]
|
|}
|-
{{PQLNote|Include the SDLC Interface Module<br>Select appropriate SDLC Cabinet Interface Module for 4 or 6 sensors}}
|
 
|[http://www.newbasis.com New Basis]
=== Vehicle Detectors (Loops) ===
|[[Media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[Media:TRF PQL TS CAT NewBasis Type1JunctionBox.pdf|PCB121212-00000 – Box only<br>PCC1212PC1-90005 – Cover only<br>PCA121212-00030 - Assembly]]
|[[Media:TRF PQL TS MEM NewBasis Type1JunctionBox.pdf|8/8/03]]
|[[Media:TRF PQL TS PHOT NewBasis Type1JunctionBox Side.jpg|Side View]]<br>[[Media:TRF PQL TS PHOT NewBasis Type1JunctionBox Top.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT NewBasis Type1JunctionBox Cover.JPG|Cover]]<br>[[Media:TRF PQL TS PHOT NewBasis Type1JunctionBox BoltHole.jpg|Bolt Hole]]
|-
|
|[https://oldcastleinfrastructure.com/ Oldcastle Infrastructure]
|[[Media:TRF_PQL_TS_CAT_OldCastle_Type1JunctionBox.pdf|12122001 - Body Only<br>12124405 - Lid Only]]
|[[Media:TRF_PQL_TS_MEM_OldCastle_Type1JunctionBox.pdf|6/5/14]]
|
|-  
|Quazite was purchased<br>by Hubbell Power Systems
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
|[[Media:TRF PQL TS CAT Quazite Type1JunctionBox.pdf|PC1212BA12 – Box only]]<br>[[Media:TRF PQL TS CAT Quazite Type1JunctionBoxCover.pdf|PC1212HA0046 – Cover only]]<br>[[Media:TRF PQL TS CAT Quazite Type1JunctionBoxAssembly.pdf|PC1212Z50346 - Assembly]]<br>[[Media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
|[[Media:TRF PQL TS MEM Quazite Type1JunctionBox.pdf|5/5/03]]
|
|}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>1 Piece cover to be ¾” min thick<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC stainless steel hex head bolts and washers}}
 
=== Type 2 Junction Box ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,232: Line 1,303:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Global Traffic Technologies<br>bought out 3M
|
|[http://www.gtt.com/canoga-traffic-sensing/ Global Traffic Technologies<br>/ 3M / Canoga]
|[http://armorcastprod.com Armorcast]
|[[media:TRF PQL TS CAT GTT VehicleDetectors.pdf|Model C922 Two Channel<br>Model C924 Four Channel]]
|[[Media:TRF PQL TS CAT Armorcast Type2JunctionBox.pdf|A6001429TA - Assembly<br>A6001428T – Cover only<br>A6001429 – Box only]]
|[[media:TRF PQL TS MEM GTT VehicleDetectors.pdf|2/18/08]]
|[[Media:TRF PQL TS MEM Armorcast Type2JunctionBox.pdf|7/30/01]]
|[[Media:TRF PQL TS PHOT Armorcast Type2JunctionBox Side.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT Armorcast Type2JunctionBox Top.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT Armorcast Type2JunctionBox Bottom.JPG|Bottom View]]
|-
|
|[http://www.newbasis.com New Basis]
|[[Media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[Media:TRF PQL TS CAT NewBasis Type2JunctionBox.pdf|PCB111812-00000 Box only<br>PCC11181P1-90019 Cover only<br>PCA111812-00030 - Assembly]]
|[[Media:TRF PQL TS MEM NewBasis Type2JunctionBox.pdf|8/8/03]]
|[[Media:TRF PQL TS PHOT NewBasis Type2JunctionBox Side.jpg|Side View]]<br>[[Media:TRF PQL TS PHOT NewBasis Type2JunctionBox Top.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT NewBasis Type2JunctionBox Cover.JPG|Cover]]
|-
|
|[https://oldcastleinfrastructure.com/ Oldcastle Infrastructure]
|[[Media:TRF_PQL_TS_CAT_OldCastle_Type2JunctionBox.pdf|11182001 - Body Only<br>11184611 - Lid Only<br>11181613 - Unit]]
|[[Media:TRF_PQL_TS_MEM_OldCastle_Type2JunctionBox.pdf|6/5/14]]
|
|
|-  
|-  
|
|Quazite was purchased<br>by Hubbell Power Systems
|[http://www.renoae.com/Category/traffic/1 Reno]
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
|[[media:TRF PQL TS CAT Reno VehicleDetectors2Ch.pdf|Model  C-1200-SS  Series Two Channel]]<br>[[media:TRF PQL TS CAT Reno VehicleDetectors4Ch.pdf|Model E-1200-SS Series – Four Channel]]
|[[Media:TRF PQL TS CAT Quazite Type2JunctionBox.pdf|PG1118BA12 – Box only]]<br>[[Media:TRF PQL TS CAT Quazite Type2JunctionBoxCover.pdf|PG1118HA0046 Cover only]]<br>[[Media:TRF PQL TS CAT Quazite Type2JunctionBoxAssembly.pdf|PG1118Z50946 - Assembly]]<br>[[Media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
|[[media:TRF PQL TS MEM Reno VehicleDetectors.pdf|2/10/12]]
|[[Media:TRF PQL TS MEM Quazite Type2JunctionBox.pdf|5/5/03]]
|
|
|}
|}
{{PQLNote|It shall have TS2 status output available}}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>1 Piece cover to be 2” thick<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}}


=== Video Detection Systems ===
=== Type 1 Service Box ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,254: Line 1,337:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Comments'''
|-
|-
|<font color="red">'''Used for Maintenance  Replacements Only'''
|[http://www.econolite.com/index.php/products/detection/ Econolite/Autoscope Encore MVP]
|Image Sensor: AENCORENP<br>Interface Panel: ATIP1<br>Access Point: ATAPE<br>Interface Cable Kit: ASTCBL10<br>SDLC Cable Harness: 33550G5
|9/11/13
|
|
|Easy-Lock Harting Connector<br>On-Board Ethernet Port<br>SDLC Cable Harness for TS-2 Comm to ASC/3 – Rack Mount Controller
|[http://armorcastprod.com Armorcast]
|[[Media:TRF PQL TS CAT Armorcast Type1ServiceBox.pdf|A6001974TAPCX24 - Assembly<br>A6001975T – Cover only<br>A6001974PCX24 – Box only]]
|[[Media:TRF PQL TS MEM Armorcast Type1ServiceBox.pdf|7/30/01]]
|[[Media:TRF PQL TS PHOT Armorcast Type1ServiceBox End.jpg|End View]]<br>[[Media:TRF PQL TS PHOT Armorcast Type1ServiceBox Top.jpg|Top View]]<br>[[Media:TRF PQL TS PHOT Armorcast Type1ServiceBox Bottom.jpg|Bottom View]]
|-  
|
|[http://www.channell.com/ Channell Commercial Corp]
|[[Media:TRF PQL TS CAT Channell Type1ServiceBox.pdf|BULKU243624F061010 - Assembly<br>BULKUA2436E061010 - Cover only<br>BULKUA2436240 - Box only]]
|[[Media:TRF PQL TS MEM Channell Type1ServiceBox.pdf|8/5/16]]
|[[Media:TRF PQL FO PHOT Channell ServiceBoxGrounding.pdf|Cover Ground Wire]]
|-
|
|[http://www.newbasis.com New Basis]
|[[Media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[Media:TRF PQL TS CAT NewBasis Type1ServiceBox.pdf|PCB24362400000 – Box only<br>PCC2436P1-00030 – Cover only<br>PCA243624-00030 – Assembly]]
|[[Media:TRF PQL TS MEM NewBasis Type1ServiceBox.pdf|2/26/02]]
|
|-
|-
|<font color="red">'''Used for Maintenance  Replacements Only'''
|[http://www.econolite.com/index.php/products/detection/ Econolite/Autoscope Terra Rack Vision]
|AIS Image Sensor: AIS4HCRZOOMU0S<br>Camera Interface Panel: AIPx<br>Coaxial Jumper Cable: RG59<br>Processor Card: ARVTERRA1E<br>SDLC Cable Harness: 33550G5
|5/17/07
|
|
|Easy-Lock Harting Connector<br>x = number of cameras to be connected to the  interface panel (1 to 6)<br>On-Board Ethernet Port
|[https://oldcastleinfrastructure.com/ Oldcastle Infrastructure]
|-
|[[Media:TRF_PQL_TS_CAT_OldCastle_Type1ServiceBox.pdf|24362214 - Body Only<br>24364613 - Lid Only<br>24361616 - Unit]]
|<font color="red">'''Used for Maintenance  Replacements Only'''
|[[Media:TRF_PQL_TS_MEM_OldCastle_Type1ServiceBox.pdf|6/5/14]]
|[http://itsplus3.com/ ITS PLUS<sup>3</sup>, Inc.]
|
|[[media:TRF PQL TS CAT ITSPlus VideoDetCamera.pdf|Advanced VIVDS Camera: ITSP-PM120C]]<br>
|-
[[media:TRF PQL TS CAT ITSPlus DetCard.pdf|Dual Channel VIVDS Card w/ Ethernet: ITSP-V200E]]<br>
|Quazite was purchased<br>by Hubbell Power Systems
[[media:TRF PQL TS CAT ITSPlus SurgeSuppressionPanel.pdf|4 Way Coax Surge Suppression Panel: ITSP-SSP-4]]<br>
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
[[media:TRF PQL TS CAT ITSPlus SDLCinterface.pdf|SDLC Module: ITSP-SDLC]]<br>
|[[Media:TRF PQL TS CAT Quazite Type1ServiceBox.pdf|PG2436BA24 – Box only]]<br>[[Media:TRF PQL TS CAT Quazite Type1ServiceBoxCover.pdf|PG2436HA0046 – Cover only]]<br>PG2436Z50246 - Assembly<br>[[Media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
[[media:TRF PQL TS CAT Remee VideoDetCable.pdf|Siamese Coax/Power Cable: ITS-Cable]]
|[[Media:TRF PQL TS MEM Quazite Type1ServiceBox.pdf|5/5/03]]
|[[media:TRF PQL TS MEM ITSPlus VideoDetectionSystem.pdf|1/27/17]]
|[[media:TRF PQL TS PHOT ITSPlus Camera.JPG|Camera Front]]<br>[[media:TRF PQL TS PHOT ITSPlus DetectionCard Front.JPG|Detection Card]]
|
|
|-
|}
|}
{{PQLReturn}}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>1 Piece cover to be 3” thick<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}}


== Grounding Equipment ==
=== Type 2 Service Box ===
=== RJ-45 Data Protector ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,295: Line 1,379:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Atlantic Scientific was purchased<br>by Cooper/Crouse Hinds
|[http://www.mtl-inst.com/ Cooper/Crouse Hinds]
|[[media:TRF PQL TS CAT CooperCrouseHinds RJ-45DataProtector.pdf|Zonebarrier-24585]]
|[[media:TRF PQL TS MEM CooperCrouseHinds RJ-45DataProtector.pdf|7/11/12]]
|
|
|[http://armorcastprod.com Armorcast]
|[[Media:TRF PQL TS CAT Armorcast Type2ServiceBox.pdf|A6001430TAPCX24 – Assembly<br>A6001470T (2 pc. Req.) – Cover only<br>A6001430PCX24 – Box only]]
|[[Media:TRF PQL TS MEM Armorcast Type2ServiceBox.pdf|7/30/01]]
|[[Media:TRF PQL TS PHOT Armorcast Type2ServiceBox Side.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT Armorcast Type2ServiceBox End.JPG|End View]]
|-
|
|[http://www.channell.com/ Channell Commercial Corp]
|[[Media:TRF PQL TS CAT Channell Type2ServiceBox.pdf|BULKU304824F081010 - Assembly<br>BULKUA3048E081010 - Cover Only<br>BULKUA3048240 - Box only]]
|[[Media:TRF PQL TS MEM Channell Type2ServiceBox.pdf|8/5/16]]
|[[Media:TRF PQL FO PHOT Channell ServiceBoxGrounding.pdf|Cover Ground Wire]]
|-
|
|[http://www.newbasis.com New Basis]
|[[Media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[Media:TRF PQL TS CAT NewBasis Type2ServiceBox.pdf|PCB30482400000 – Box only<br>PCC3048P2-90039 – Cover only<br>PCA304824-00062 – Assembly]]
|[[Media:TRF PQL TS MEM NewBasis Type2ServiceBox.pdf|2/26/02]]
|[[Media:TRF PQL TS PHOT NewBasis Type2ServiceBox Side.JPG|Side View]]
|-
|-
|
|
|[http://www.protectiongroup.com/Home Protection Technology Group / Transector]
|[https://oldcastleinfrastructure.com/ Oldcastle Infrastructure]
|[[media:TRF PQL TS CAT ProtectionTechnologyGroup RJ-45DataProtector cut sheet.pdf|Model: TSJ-GbE PoE]]<br>[[media:TRF PQL TS CAT ProtectionTechnologyGroup RJ-45DataProtector.pdf|Part Number: 1101-994]]
|[[Media:TRF_PQL_TS_CAT_OldCastle_Type2ServiceBox.pdf|30482021 - Body Only<br>30484611 - Lid Only]]
|[[media:TRF PQL TS MEM ProtectionTechnologyGroup RJ-45DataProtector.pdf|2/11/14]]
|[[Media:TRF_PQL_TS_MEM_OldCastle_Type2ServiceBox.pdf|6/5/14]]
|[[media:TRF PQL TS PHOT ProtectionTechnologyGroup RJ-45DataProtector Top.JPG|Top View]]<br>[[media:TRF PQL PHOT ProtectionTechnologyGroup RJ-45DataProtector Side.JPG|Side View]]
|
|-
|Quazite was purchased<br>by Hubbell Power Systems
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
|[[Media:TRF PQL TS CAT Quazite Type2ServiceBox.pdf|PG3048BA24 – Box only]]<br>[[Media:TRF PQL TS CAT Quazite Type2ServiceBoxCover.pdf|PG3048HS0046 – Cover only]]<br>PG3048Z52546 - Assembly<br>[[Media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
|[[Media:TRF PQL TS MEM Quazite Type2ServiceBox.pdf|5/5/03]]
|
|}
|}
{{PQLNote|Use with IP High Definition CCTV Cameras}}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>2 Piece cover to be 3” thick underlapping<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}}
{{PQLReturn}}


=== Ground Rod ===
== LED Units ==
=== Red LED Arrow ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,319: Line 1,423:
|-
|-
|
|
|[http://www.erico.com/products/copper-bonded.asp Erico Inc.]
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[[media:TRF PQL TS CAT Erico-Eritech Groundrod.pdf|5/8” x 8’-0” Cat. No. 615880<br>5/8” x 10’-0” Cat. No. 615800]]
|[[Media:TRF PQL CAT Dialight LEDArrows.pdf|432-1314-001XOD15]]
|[[media:TRF PQL TS MEM EricoEritech GroundRod.pdf|2/27/02]]
|[[Media:TRF PQL MEM Dialight Arrow&BallLEDs.pdf|11/13/19]]
|[[Media:TRF PQL PHOT Dialight LEDArrows RedArrow.jpg|Front View]]<br>[[Media:TRF PQL PHOT Dialight LEDArrows RedArrowBack.jpg|Back View]]<br>[[Media:TRF PQL PHOT Dialight LEDArrows RedArrowLabel.jpg|Label]]
|-
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[Media:TRF PQL TS CAT Leotek LEDArrows.pdf|TSL-12RA-DT-A1]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|11/13/19]]
|[[Media:TRF PQL TS PHOT Leotek LEDRedArrow Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDRed Arrow Back.JPG|Back View]]
|}
{{PQLNote|Tinted lens<br>Incandescent look<br>15 Year Warranty}}
=== Yellow LED Arrow ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|
|[http://www.galvanelectrical.com/ground-rods.asp Galvan Industries]
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[[media:TRF PQL TS CAT Galvan GroundRod.pdf|5/8" x 8'-0" Cat. No. 6258<br>5/8" x 10'-0: Cat. No. 6260]]
|[[Media:TRF PQL CAT Dialight LEDArrows.pdf|431-3334-901XOD15]]
|[[media:TRF PQL TS MEM Galvan GroundRod.pdf|12/20/13]]
|[[Media:TRF PQL MEM Dialight Arrow&BallLEDs.pdf|11/13/19]]
|
|[[Media:TRF PQL PHOT Dialight LEDArrows YellowArrow.jpg|Front View]]<br>[[Media:TRF PQL PHOT Dialight LEDArrows YellowArrowBack.jpg|Back View]]<br>[[Media:TRF PQL PHOT Dialight LEDArrows YellowArrowLabel.jpg|Label]]
|-
|-
|
|
|[http://www.hubbellpowersystems.com/pole-line/grounding/copper/ Hubbell]
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT ChanceHubbell GroundRod.pdf|5/8" x 8’-0” Cat. No. C615880<br>5/8” x 10’-0” Cat No. C635800]]
|[[Media:TRF PQL TS CAT Leotek LEDArrows.pdf|TSL-12YA-DT-A1]]
|[[media:TRF PQL TS MEM ChanceHubbell GroundRod.pdf|4/24/12]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|11/13/19]]
|
|[[Media:TRF PQL TS PHOT Leotek LEDYellow Arrow Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDYellow Arrow Back.JPG|Back View]]
|-
|
|[http://www.tnb.com/pub/index.php Thomas & Betts]
|[[media:TRF PQL TS CAT Thomas&Betts Groundrod.pdf|5/8” x 8’-0” Cat. No. 6258<br>5/8” x 10’-0” Cat No. 6260]]
|[[media:TRF PQL TS MEM Thomas&Betts GroundRod.pdf|5/5/03]]
|
|-
|}
|}
{{PQLNote|5/8” x 10’-0” long at poles and controller cabinet<br>5/8” x 8’-0” long at service boxes<br>Copper clad steel core<br>UL listed}}
{{PQLNote|Tinted lens<br>Incandescent look<br>15 Year Warranty}}
{{PQLReturn}}


=== Ground Rod Clamp ===
=== Green LED Arrow ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,356: Line 1,469:
|-
|-
|
|
|[http://www.burndy.com/ Burndy]
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[[media:TRF PQL TS CAT Burndy GroundRodClamp.pdf|GRC58 – 5/8”]]
|[[Media:TRF PQL CAT Dialight LEDArrows.pdf|432-2324-001XOD15]]
|[[media:TRF PQL TS MEM Burndy GroundRodClamp.pdf|2/27/02]]
|[[Media:TRF PQL MEM Dialight Arrow&BallLEDs.pdf|11/13/19]]
|[[media:TRF PQL TS PHOT Burndy GroundRodClamp.JPG|Clamp]]
|[[Media:TRF PQL TS PHOT Dialight LEDGreenArrow Front.jpg|Front View]]<br>[[Media:TRF PQL TS PHOT Dialight LEDGreenArrow Wiring.jpg|Wiring]]
|-
|-
|
|
|[http://www.erico.com/products/RodAccessories.asp Erico Inc.]
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Erico-Eritech GroundRodClamp.pdf|HDC58 – 5/8”]]
|[[Media:TRF PQL TS CAT Leotek LEDArrows.pdf|TSL-12GA-DT-A1]]
|[[media:TRF PQL TS MEM EricoEritech GroundRodClamp.pdf|12/1/05]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|11/13/19]]
|
|[[Media:TRF PQL TS PHOT Leotek LEDGreen Arrow Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDGreen Arrow Back.JPG|Back View]]
|-
|
|[http://www.galvanelectrical.com/ground-rods.asp Galvan Industries]
|[[media:TRF PQL TS CAT Galvan GroundRodClamp.pdf|SRC – 5/8”]]
|[[media:TRF PQL TS MEM Galvan GroundRodClamp.pdf|12/20/13]]
|
|-
|
|[http://www.tnb.com/pub/en/node/2 Thomas & Betts]
|[[media:TRF PQL TS CAT ThomasBetts GroundRodClamp.pdf|JAB58H - 5/8"]]
|[[media:TRF PQL TS MEM ThomasBetts GroundRodClamps.pdf|5/5/03]]
|
|}
|}
{{PQLNote|Hex head set screw<br>Copper alloy<br>Long bearing surface<br>UL listed}}
{{PQLNote|Tinted lens<br>Incandescent look<br>15 Year Warranty}}


== Junction and Service Boxes ==
=== Bi-Modal Green/Yellow LED Arrow ===
=== Type 1 Junction Box ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,392: Line 1,492:
|-
|-
|
|
|[http://armorcastprod.com Armorcast]
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[[media:TRF PQL TS CAT Armorcast Type1JunctionBox.pdf|A6001423TA – Assembly<br>A6001422T – Cover only<br>A6001423 – Box only]]
|430-6370-001
|[[media:TRF PQL TS MEM Armorcast Type1JunctionBox.pdf|1/11/01]]
|[[Media:TRF PQL TS MEM Dialight LED.pdf|4/30/10]]
|
|
|-  
|-
|
|
|[http://highlineproducts.com Highline]
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/index.jsp GE]
|[[media:TRF PQL TS CAT Highline ServiceBox CatalogNumber.pdf|Product Number Nomenclature]]<br>[[media:TRF PQL TS CAT Highline Type1JunctionBox.pdf|PHB121212 – Box only<br>CHC1212HS –  Cover only<br>PHA121212HS2 – Assembly]]
|DR6-ECA6-21A
|[[media:TRF PQL TS MEM Highline Type1JunctionBox.pdf|3/3/11]]
|[[Media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
||[[media:TRF PQL TS CAT Highline Type1JunctionBox Side.jpg|Side View]]<br>[[media:TRF PQL TS CAT Highline Type1JunctionBox Top.jpg|Top View]]<br>[[media:TRF PQL TS CAT Highline Type1JunctionBox Bottom.jpg|Bottom View]]
|-  
|
|[http://martinfrp.com Martin Enterprises]
|[[media:TRF PQL TS CAT Martin Type1JunctionBox.pdf|121212PCC –  Box only<br>1212PCC –  Cover only<br>121212PC – Assembly]]
|[[media:TRF PQL TS MEM MartinEnterprises Type1JunctionBox.pdf|10/17/11]]
|[[media:TRF PQL TS PHOT MartinEnterprises Type1JunctionBox Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT MartinEnterprises Type1JunctionBox Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT MartinEnterprises Type1JunctionBox Cover.JPG|Cover]]<br>[[media:TRF PQL TS PHOT MartinEnterprises Type1JunctionBox BoltHole.JPG|Bolt Hole]]
|-
|
|
|[http://www.newbasis.com New Basis]
|[[media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[media:TRF PQL TS CAT NewBasis Type1JunctionBox.pdf|PCB121212-00000 – Box only<br>PCC1212PC1-90005 – Cover only<br>PCA121212-00030 - Assembly]]
|[[media:TRF PQL TS MEM NewBasis Type1JunctionBox.pdf|8/8/03]]
|[[media:TRF PQL TS PHOT NewBasis Type1JunctionBox Side.jpg|Side View]]<br>[[media:TRF PQL TS PHOT NewBasis Type1JunctionBox Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT NewBasis Type1JunctionBox Cover.JPG|Cover]]<br>[[media:TRF PQL TS PHOT NewBasis Type1JunctionBox BoltHole.jpg|Bolt Hole]]
|-
|-
|Carson H Series boxes were<br>purchased by Oldcastle
|[http://www.oldcastle.com/index.php Oldcastle]
|[[media:TRF PQL TS CAT OldCastle Type1JunctionBox PartNumbers.pdf|Part Numbers]]<br>[[media:TRF PQL TS CAT OldCastle Type1JunctionBox.pdf|12122001 – Box only<br>12124010 – Synertech Cover only<br>12121610 – Assembly<br>80002033 hex head bolts if separate]]
|[[media:TRF PQL TS MEM Oldcastle Type1JunctionBox.pdf|6/5/14]]
|[[media:TRF PQL TS PHOT OldCastle Type1JunctionBox Cover.jpg|Cover]]
|-
|Quazite was purchased<br>by Hubbell Power Systems
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
|[[media:TRF PQL TS CAT Quazite Type1JunctionBox.pdf|PC1212BA12 – Box only]]<br>[[media:TRF PQL TS CAT Quazite Type1JunctionBoxCover.pdf|PC1212HA0046 – Cover only]]<br>[[media:TRF PQL TS CAT Quazite Type1JunctionBoxAssembly.pdf|PC1212Z50346 - Assembly]]<br>[[media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
|[[media:TRF PQL TS MEM Quazite Type1JunctionBox.pdf|5/5/03]]
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[Media:TRF PQL TS CAT Leotek LEDBi-ModalArrows.pdf|TSL-12BM-LD-A1]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[Media:TRF PQL TS PHOT Leotek LEDBi-ModalArrow Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDBi-ModalArrow Back.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDBi-ModalArrow Label.JPG|Label]]
|}
|}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>1 Piece cover to be ¾” min thick<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}}
{{PQLNote|Clear Lens, pixilated arrow}}
{{PQLReturn}}


=== Type 2 Junction Box ===
=== Red Ball LED ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,440: Line 1,521:
|-
|-
|
|
|[http://armorcastprod.com Armorcast]
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[[media:TRF PQL TS CAT Armorcast Type2JunctionBox.pdf|A6001429TA - Assembly<br>A6001428T – Cover only<br>A6001429 – Box only]]
|[[Media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|DuraLED 433-1210-003XL15]]
|[[media:TRF PQL TS MEM Armorcast Type2JunctionBox.pdf|7/30/01]]
|[[Media:TRF PQL CAT Dialight LEDBalls.pdf|11/13/19]]
|[[media:TRF PQL TS PHOT Armorcast Type2JunctionBox Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT Armorcast Type2JunctionBox Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Armorcast Type2JunctionBox Bottom.JPG|Bottom View]]  
|[[Media:TRF PQL PHOT Dialight LEDBalls RedBall.jpg|Front View]]<br>[[Media:TRF PQL PHOT Dialight LEDBalls RedBallBack.jpg|Back View]]<br>[[Media:TRF PQL PHOT Dialight LEDBalls RedBallLabel.jpg|Label]]
|-
|-
|
|
|[http://highlineproducts.com Highline]
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Highline ServiceBox CatalogNumber.pdf|Product Number Nomenclature]]<br>[[media:TRF PQL TS CAT Highline Type2JunctionBox.pdf|PHB111812 – Box only<br>CHC1118SS –  Cover only<br>PHA111812SS2 - Assembly]]
|[[Media:TRF PQL TS CAT Leotek LEDBall.pdf|TSL-12R-DT-A1]]
|[[media:TRF PQL TS MEM Highline Type2JunctionBox.pdf|3/3/11]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|11/13/19]]
|[[media:TRF PQL TS CAT Highline Type2JunctionBox Side.jpg|Side View]]<br>[[media:TRF PQL TS CAT Highline Type2JunctionBox Top.jpg|Top View]]<br>[[media:TRF PQL TS CAT Highline Type2JunctionBox Cover.jpg|Cover]]<br>[[media:TRF PQL TS CAT Highline Type2JunctionBox Bottom.jpg|Bottom View]]
|[[Media:TRF PQL TS PHOT Leotek LEDRedBall Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDRedBall Back.JPG|Back View]]
|-
|}
|
{{PQLNote|Tinted lens<br>Incandescent look<br>15 Year Warranty}}
|[http://martinfrp.com Martin Enterprises]
 
|[[media:TRF PQL TS CAT Martin Type2JunctionBox.pdf|111812PCB – Box only<br>1118PCC –  Cover only<br>111812PC – Assembly]]
=== Yellow Ball LED ===
|[[media:TRF PQL TS MEM MartinEnterprises Type2JunctionBox.pdf|10/17/11]]
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|
|+
|-  
| align="center" style="background:#f0f0f0;"|'''Notes'''
|
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
|[http://www.newbasis.com New Basis]
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
|[[media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[media:TRF PQL TS CAT NewBasis Type2JunctionBox.pdf|PCB111812-00000 – Box only<br>PCC11181P1-90019 – Cover only<br>PCA111812-00030 - Assembly]]
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
|[[media:TRF PQL TS MEM NewBasis Type2JunctionBox.pdf|8/8/03]]
| align="center" style="background:#f0f0f0;"|'''Photos'''
|[[media:TRF PQL TS PHOT NewBasis Type2JunctionBox Side.jpg|Side View]]<br>[[media:TRF PQL TS PHOT NewBasis Type2JunctionBox Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT NewBasis Type2JunctionBox Cover.JPG|Cover]]
|-
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[[Media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|DuraLED 433-3230-901XL15]]
|[[Media:TRF PQL CAT Dialight LEDBalls.pdf|11/13/19]]
|[[Media:TRF PQL PHOT Dialight LEDBalls YellowBall.jpg|Front View]]<br>[[Media:TRF PQL PHOT Dialight LEDBalls YellowBallBack.jpg|Back View]]<br>[[Media:TRF PQL PHOT Dialight LEDBalls YellowBallLabel.jpg|Label]]
|-
|-
|Carson H Series boxes were<br>purchased by Oldcastle
|[http://www.oldcastle.com/index.php Oldcastle]
|[[media:TRF PQL TS CAT OldCastle Type2JunctionBox PartNumbers.pdf|Part Numbers]]<br>[[media:TRF PQL TS CAT Oldcastle Type2JunctionBox.pdf|11182001 – Box only<br>11184611 – Cover only<br>11181613 – Assembly<br>80002033 hex head bolts if separate]]
|[[media:TRF PQL TS MEM Oldcastle Type2JunctionBox.pdf|8/29/13]]
|[[media:TRF PQL TS PHOT OldCastle Type2JunctionBox Side.jpg|Side View]]<br>[[media:TRF PQL TS PHOT OldCastle Type2JunctionBox End.jpg|End view]]<br>[[media:TRF PQL TS PHOT OldCastle Type2JunctionBox Cover.jpg|Cover]]
|-
|Quazite was purchased<br>by Hubbell Power Systems
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
|[[media:TRF PQL TS CAT Quazite Type2JunctionBox.pdf|PG1118BA12 – Box only]]<br>[[media:TRF PQL TS CAT Quazite Type2JunctionBoxCover.pdf|PG1118HA0046 – Cover only]]<br>[[media:TRF PQL TS CAT Quazite Type2JunctionBoxAssembly.pdf|PG1118Z50946 - Assembly]]<br>[[media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
|[[media:TRF PQL TS MEM Quazite Type2JunctionBox.pdf|5/5/03]]
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[Media:TRF PQL TS CAT Leotek LEDBall.pdf|TSL-12Y-DT-A1]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|11/13/19]]
|[[Media:TRF PQL TS PHOT Leotek LEDYellowBall Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDYellowBall Back.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDYellowBall Label.jpg|Yellow Ball Label]]
|}
|}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>1 Piece cover to be 2” thick<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}}
{{PQLNote|Tinted lens<br>Incandescent look<br>15 Year Warranty}}
{{PQLReturn}}


=== Type 1 Service Box ===
=== Green Ball LED ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,488: Line 1,567:
|-
|-
|
|
|[http://armorcastprod.com Armorcast]
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[[media:TRF PQL TS CAT Armorcast Type1ServiceBox.pdf|A6001974TAPCX24 - Assembly<br>A6001975T – Cover only<br>A6001974PCX24 – Box only]]
|[[Media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|DuraLED 433-2220-001XL15]]
|[[media:TRF PQL TS MEM Armorcast Type1ServiceBox.pdf|7/30/01]]
|[[Media:TRF PQL CAT Dialight LEDBalls.pdf|11/13/19]]
|[[media:TRF PQL TS PHOT Armorcast Type1ServiceBox End.jpg|End View]]<br>[[media:TRF PQL TS PHOT Armorcast Type1ServiceBox Top.jpg|Top View]]<br>[[media:TRF PQL TS PHOT Armorcast Type1ServiceBox Bottom.jpg|Bottom View]]
|[[Media:TRF PQL PHOT Dialight LEDBalls GreenBall.jpg|Front View]]<br>[[Media:TRF PQL PHOT Dialight LEDBalls GreenBallBack.jpg|Back View]]<br>[[Media:TRF PQL PHOT Dialight LEDBalls GreenBallLabel.jpg|Label]]
|-
|
|[http://www.channell.com/ Channell Commercial Corp]
|[[media:TRF PQL TS CAT Channell Type1ServiceBox.pdf|BULKU243624F061010 - Assembly<br>BULKUA2436E061010 - Cover only<br>BULKUA2436240 - Box only]]
|[[media:TRF PQL TS MEM Channell Type1ServiceBox.pdf|8/5/16]]
|[[media:TRF PQL FO PHOT Channell ServiceBoxGrounding.pdf|Cover Ground Wire]]
|-
|-
|
|
|[http://highlineproducts.com Highline]
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Highline ServiceBox CatalogNumber.pdf|Product Number Nomenclature]]<br>[[media:TRF PQL TS CAT Highline Type1ServiceBox.pdf|PHB243624 – Box only<br>CHC2436HS –  Cover only<br>PHA243624HS2 – Assembly]]
|[[Media:TRF PQL TS CAT Leotek LEDBall.pdf|TSL-12G-DT-A1]]
|[[media:TRF PQL TS MEM Highline Type1ServiceBox.pdf|3/3/11]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|11/13/19]]
|[[media:TRF PQL TS PHOT Highline Type1ServiceBox Side.jpg|Side View]]<br>[[media:TRF PQL TS PHOT Highline Type1ServiceBox End.jpg|End View]]<br>[[media:TRF PQL TS PHOT Highline Type1ServiceBox Bolthole.jpg|Bolt Hole]]
|[[Media:TRF PQL TS PHOT Leotek LEDGreenBall Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDGreenBall Back.JPG|Back View]]
|-  
|}
|
{{PQLNote|Tinted lens<br>Incandescent look<br>15 Year Warranty}}
|[http://martinfrp.com Martin Enterprises]
 
|[[media:TRF PQL TS CAT Martin Type1ServiceBox.pdf|243624PCB – Box only<br>2436PCC – Cover only<br>243624PC - Assembly]]
=== Countdown Pedestrian LED ===
|[[media:TRF PQL TS MEM MartinEnterprises Type1ServiceBox.pdf|10/17/11]]
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|[[media:TRF PQL TS PHOT MartinEnterprises Type1ServiceBox Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT MartinEnterprises Type1ServiceBox End.JPG|End View]]<br>[[media:TRF PQL TS PHOT MartinEnterprises Type1ServiceBox Cover.JPG|Cover]]<br>[[media:TRF PQL TS PHOT MartinEnterprises Type1ServiceBox BoltHole.JPG|Bolt Hole]]
|+
|-  
| align="center" style="background:#f0f0f0;"|'''Notes'''
|
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
|[http://www.newbasis.com New Basis]
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
|[[media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[media:TRF PQL TS CAT NewBasis Type1ServiceBox.pdf|PCB24362400000 – Box only<br>PCC2436P1-00030 – Cover only<br>PCA243624-00030 – Assembly]]
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
|[[media:TRF PQL TS MEM NewBasis Type1ServiceBox.pdf|2/26/02]]
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|
|[http://www.dialightsignalsandcomponents.com/Product/Category/ITE_Specification#51 DiaLight]
|[[Media:TRF PQL TS CAT Dialight LEDCountdownPed.pdf|430-6479-001X]]
|[[Media:TRF PQL TS MEM Dialight LED.pdf|4/30/10]]
|
|-
|
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/led-traffic-signals/gtx-city-pedestrian-units.jsp GE]
|[[Media:TRF PQL TS CAT GE CountdownPedestrianLED.pdf|GTX City Series: PS7-CFF1-VLA]]
|[[Media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
|[[Media:TRF PQL TS PHOT GE CountdownPedestrianLED FrontView.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT GE CountdownPedestrianLED BackView.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT GE CountdownPedestrianLED Gasket.JPG|Gasket]]<br>[[Media:TRF PQL TS PHOT GE CountdownPedestrianLED CountdownView.JPG|Countdown View]]
|-
|-
|Carson H Series boxes were<br>purchased by Oldcastle
|[http://www.oldcastle.com/index.php Oldcastle]
|[[media:TRF PQL TS CAT Oldcastle Type1ServiceBox PartNumbers.pdf|Part Numbers]]<br>[[media:TRF PQL TS CAT Oldcastle Type1ServiceBox.pdf|24362214 – Box only<br>24364613 – Cover only<br>24361616 – Assembly<br>80002029 hex head bolts if separate]]
|[[media:TRF PQL TS MEM Oldcastle Type1ServiceBox.pdf|8/29/13]]
|[[media:TRF PQL TS PHOT Oldcastle Type1ServiceBox Side.jpg|Side View]]<br>[[media:TRF PQL TS PHOT Oldcastle Type1ServiceBox End.jpg|End View]]<br>[[media:TRF PQL TS PHOT Oldcastle Type1ServiceBox Cover.jpg|Cover]]<br>[[media:TRF PQL TS PHOT Oldcastle Type1ServiceBox BoltHole.jpg|Bolt Hole]]
|-
|Quazite was purchased<br>by Hubbell Power Systems
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
|[[media:TRF PQL TS CAT Quazite Type1ServiceBox.pdf|PG2436BA24 – Box only]]<br>[[media:TRF PQL TS CAT Quazite Type1ServiceBoxCover.pdf|PG2436HA0046 – Cover only]]<br>PG2436Z50246 - Assembly<br>[[media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
|[[media:TRF PQL TS MEM Quazite Type1ServiceBox.pdf|5/5/03]]
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[Media:TRF PQL TS CAT Leotek LEDPedCountdown.pdf|TSL-PED-16-SPC-V1]]
|[[Media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[Media:TRF PQL TS PHOT Leotek LEDPedCountdown Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Leotek LEDPedCountdown Label.JPG|Label]]<br>[[Media:TRF PQL TS PHOT Leotek LEDPedCountdown Back.JPG|Back View]]
|}
|}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>1 Piece cover to be 3” thick<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}}
{{PQLNote|16” X 18” <br> Hand/Person display symbol <br> Orange/White display color <br>Incandescent look<br>Filled/Overlay Style<br>9” Numerals}}


=== Type 2 Service Box ===
== Loop Sealants ==
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,541: Line 1,619:
|-
|-
|
|
|[http://armorcastprod.com Armorcast]
|[http://3mcollision.com/bondo-detector-loop-sealant-5000-4-5-gallon-pail-35382.html#moreInfoDetails 3M]
|[[media:TRF PQL TS CAT Armorcast Type2ServiceBox.pdf|A6001430TAPCX24 – Assembly<br>A6001470T (2 pc. Req.) – Cover only<br>A6001430PCX24 – Box only]]  
|[[Media:TRF PQL TS CAT 3M LoopSealant.pdf|5000]]
|[[media:TRF PQL TS MEM Armorcast Type2ServiceBox.pdf|7/30/01]]
|[[Media:TRF PQL TS MEM 3M LoopSealant.pdf|5/5/03]]
|[[media:TRF PQL TS PHOT Armorcast Type2ServiceBox Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT Armorcast Type2ServiceBox End.JPG|End View]]
|-
|
|
|[http://www.channell.com/ Channell Commercial Corp]
|[[media:TRF_PQL_TS_CAT_Channell_Type2ServiceBox.pdf|BULKU304824F081010 - Assembly<br>BULKUA3048E081010 - Cover Only<br>BULKUA3048240 - Box only]]
|[[media:TRF PQL TS MEM Channell Type2ServiceBox.pdf|8/5/16]]
|[[media:TRF PQL FO PHOT Channell ServiceBoxGrounding.pdf|Cover Ground Wire]]
|-
|-
|Purchased by Royal Adhesives & Sealants<br>Under acquisition by HB Fuller
|[http://www.chemque.com/pages.php?page=Q-Seal Chemque]
|[[Media:TRF PQL TS CAT Chemque LoopSealant.pdf|Q-Seal 290S - Grey or Black]]
|[[Media:TRF PQL TS MEM Chemque LoopSealant.pdf|10/23/03]]
|
|
|[http://highlineproducts.com Highline]
|-
|[[media:TRF PQL TS CAT Highline ServiceBox CatalogNumber.pdf|Product Number Nomenclature]]<br>[[media:TRF PQL TS CAT Highline Type2ServiceBox.pdf|PHB304824 – Box only<br>CHC3048HS-2PC  – Cover only<br>PHA304824HS4 – Assembly]]
|[[media:TRF PQL TS MEM Highline Type2ServiceBox.pdf|3/3/11]]
|
|
|-
|[https://crafco.com/ Crafco Inc]
|[[Media:TRF PQL TS CAT Crafco LoopSealant.pdf|RoadSaver 221, Part No. 34221]]
|[[Media:TRF PQL TS MEM Crafco LoopSealant.pdf|5/5/03]]
|
|
|[http://martinfrp.com Martin Enterprises]
|-
|[[media:TRF PQL TS CAT Martin Type2ServiceBox.pdf|304824PCB – Box only<br>3048PCC –  Cover only<br>304824PC - Assembly]]
|[[media:TRF PQL TS MEM MartinEnterprises Type2ServiceBox.pdf|10/17/11]]
|
|
|-
|[http://www.ruscoe.com/highway-products/ Ruscoe Highway Products]
|
|[[Media:TRF PQL TS CAT Ruscoe LoopSealant.pdf|Permanent Sealer 974 Gray or Black]]
|[http://www.newbasis.com New Basis]
|[[Media:TRF PQL TS MEM Ruscoe LoopSealant.pdf|7/3/13]]
|[[media:TRF PQL TS CAT NewBasis ServiceBoxLabel.pdf|Cover Label]]<br>[[media:TRF PQL TS CAT NewBasis Type2ServiceBox.pdf|PCB30482400000 – Box only<br>PCC3048P2-90039 – Cover only<br>PCA304824-00062 – Assembly]]
|[[media:TRF PQL TS MEM NewBasis Type2ServiceBox.pdf|2/26/02]]
|[[media:TRF PQL TS PHOT NewBasis Type2ServiceBox Side.JPG|Side View]]
|-
|Carson H Series boxes were<br>purchased by Oldcastle
|[http://www.oldcastle.com/index.php Oldcastle]
|[[media:TRF PQL TS CAT Oldcastle Type2ServiceBox PartNumbers.pdf|Part Numbers]]<br>[[media:TRF PQL TS CAT Oldcastle Type2ServiceBox.pdf|30482021 – Box only<br>30484611 – Cover only<br>30481618 Assembly<br>80002029 hex head bolts if separate]]
|[[media:TRF PQL TS MEM Oldcastle Type2ServiceBox.pdf|8/29/13]]
|[[media:TRF PQL TS PHOT Oldcastle Type2ServiceBox Side.jpg|Side View]]<br>[[media:TRF PQL TS PHOT Oldcastle Type2ServiceBox End.jpg|End View]]<br>[[media:TRF PQL TS PHOT Oldcastle Type2ServiceBox Top.jpg|Top View]]<br>[[media:TRF PQL TS PHOT Oldcastle Type2ServiceBox Cover.jpg|Cover]]<br>[[media:TRF PQL TS PHOT Oldcastle Type2ServiceBox BoltHole.jpg|Bolt Hole]]
|-
|Quazite was purchased<br>by Hubbell Power Systems
|[http://www.hubbellpowersystems.com/about/quazite Quazite]
|[[media:TRF PQL TS CAT Quazite Type2ServiceBox.pdf|PG3048BA24 – Box only]]<br>[[media:TRF PQL TS CAT Quazite Type2ServiceBoxCover.pdf|PG3048HS0046 – Cover only]]<br>PG3048Z52546 - Assembly<br>[[media:TRF PQL TS CAT Quazite ServiceBoxCoverCodes.pdf|Cover Codes]]
|[[media:TRF PQL TS MEM Quazite Type2ServiceBox.pdf|5/5/03]]
|
|
|}
|}
{{PQLNote|Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)<br>Logo to read “Traffic Signal”<br>2 Piece cover to be 3” thick underlapping<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}}
{{PQLReturn}}
{{PQLReturn}}


== LED Units ==
== Miscellaneous Controller Equipment ==
=== Red LED Arrow ===
 
=== ATC Cabinet Specific Equipment ===
 
==== ATC Controller ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,596: Line 1,658:
|-
|-
|
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[https://www.econolite.com/ Econolite]
|[[media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|432-1314-001XOD]]
|[[Media:TRF PQL TS CAT Econolite 2070Controller.pdf|2070EOS1D6500 w/EOS]]
|[[media:TRF_PQL_TS_MEM_Dialight_LED.pdf|4/30/10]]
|[[Media:TRF PQL TS MEM Econolite 2070Controller.pdf|11/8/21]]
|[[media:TRF PQL TS PHOT Dialight LEDRedArrow Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Dialight LEDRedArrow Back.JPG|Back View]]
|
|-
|-
|
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/led-traffic-signals/gt1-arrow-signals-incandescent-look.jsp GE]
|[https://www.mccain-inc.com/ McCain]
|[[media:TRF PQL TS CAT GE LEDArrow.pdf|GTX Series: DR6-RTAAN-VLA]]
|[[Media:TRF PQL TS CAT McCain ATC2070Controller.pdf|ATC eX 2070 PN: M46541]]
|[[media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
|[[Media:TRF PQL TS CAT McCain ATC2070Controller.pdf|10/16/18]]
|
|
|-
|-
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[https://www.q-free.com/ Q-Free / Intelight]
|[[media:TRF PQL TS CAT Leotek LEDArrows.pdf|TSL-12RA-IL6-A1-P3]]
|[[Media:TRF PQL TS CAT Q-Free Controller.pdf|YCT-2070LX-MT]]<br><br><u>Individual Component Parts</u>:<br>Controller: [[Media:TRF PQL TS CAT Q-Free Controller.pdf|2070LX]]<br>FIO Module: [[Media:TRF PQL TS CAT Q-Free FIOModule.pdf|2070-2E+]]<br>1C CPU Module: [[Media:TRF PQL TS CAT Q-Free CPUModule.pdf|2070-1C]]<br>Software:[[Media:TRF PQL TS CAT Q-Free Software.pdf|MAXTIME 1C]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[Media:TRF PQL TS MEM Q-Free Controller.pdf|11/4/21]]
|[[media:TRF PQL TS PHOT Leotek LEDRedArrow Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDRed Arrow Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Leotek LEDRed Arrow Label.JPG|Label]]
|
|-
|}
|}
{{PQLNote|Tinted lens<br>Incandescent look}}
{{PQLNote|With Data Key<br>Firmware shall be provided with the controller}}


=== Yellow LED Arrow ===
==== ATC Cabinet Power Supply ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,625: Line 1,688:
|-
|-
|
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[https://www.editraffic.com/ EDI / Eberle Design Inc]
|[[media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|431-3334-901XOD]]
|[[Media:TRF PQL TS CAT EDI ATCCabinetPowerSupply.pdf|PS-2216-24-HV]]
|[[media:TRF_PQL_TS_MEM_Dialight_LED.pdf|4/30/10]]
|[[Media:TRF PQL TS MEM EDI ATCCabinetPowerSupply.pdf|10/16/18]]
|
|-
|
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/led-traffic-signals/gt1-arrow-signals-incandescent-look.jsp GE]
|[[media:TRF PQL TS CAT GE LEDArrow.pdf|GTX Series: DR6-YTAAN-VLA]]
|[[media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
|
|-
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Leotek LEDArrows.pdf|TSL-12YA-IL6-A1-P3]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[media:TRF PQL TS PHOT Leotek LEDYellow Arrow Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDYellow Arrow Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Leotek LEDRed Arrow Label.JPG|Label]]
|}
|}
{{PQLNote|Tinted lens<br>Incandescent look}}
{{PQLNote|Used only in ATC Cabinet.}}


=== Green LED Arrow ===
==== Auxiliary Display Unit (ADU) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,654: Line 1,705:
|-
|-
|
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[[media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|432-2324-001XOD]]
|[[Media:TRF PQL TS CAT EDI AuxiliaryDisplayUnit.pdf|ADU]]
|[[media:TRF_PQL_TS_MEM_Dialight_LED.pdf|4/30/10]]
|[[Media:TRF PQL TS MEM EDI AuxiliaryDisplayUnit.pdf|10/16/18]]
|[[media:TRF PQL TS PHOT Dialight LEDGreenArrow Front.jpg|Front View]]<br>[[media:TRF PQL TS PHOT Dialight LEDGreenArrow Wiring.jpg|Wiring]]
|-
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/led-traffic-signals/gt1-arrow-signals-incandescent-look.jsp GE]
|[[media:TRF PQL TS CAT GE LEDArrow.pdf|GTX Series: DR6-GTAAN-VLA]]
|[[media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
|
|-
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Leotek LEDArrows.pdf|TSL-12GA-IL6-A1-P3]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[media:TRF PQL TS PHOT Leotek LEDGreen Arrow Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDGreen Arrow Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Leotek LEDGreen Arrow Label.JPG|Label]]
|}
|}
{{PQLNote|Tinted lens<br>Incandescent look}}
{{PQLNote|Used only in ATC Cabinet}}


=== Bi-Modal Green/Yellow LED Arrow ===
==== Cabinet Alarm Panel ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,683: Line 1,722:
|-
|-
|
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[https://www.econolite.com/ Econolite]
|430-6370-001
|[[Media:TRF PQL TS CAT Econolite CabinetAlarmPanel.pdf|177-1018-501]]
|[[media:TRF_PQL_TS_MEM_Dialight_LED.pdf|4/30/10]]
|[[Media:TRF PQL TS MEM Econolite CabinetAlarmPanel.pdf|6/16/22]]
|
|
|-
|-
|
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/index.jsp GE]
|[https://www.mccain-inc.com/ McCain Traffic]
|DR6-ECA6-21A
|[[Media:TRF PQL TS CAT McCain ATCCabinetAlarmPanel.pdf|2521 - Cabinet Alarm Panel and Harness]]
|[[media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
|[[Media:TRF PQL TS MEM McCain ATCCabinetAlarmPanel.pdf|11/3/21]]
|[[Media:TRF PQL TS PHOT McCain ATCCabinetAlarmPanel Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT McCain ATCCabinetAlarmPanel Back.JPG|Back View]]
|-
|
|
|-
|[https://www.mobotrex.com/ Mobotrex]
|[[Media:TRF PQL TS CAT Mobotrex CabinetAlarmPanel.pdf|AAD18150-001]]
|[[Media:TRF PQL TS MEM Mobotrex CabinetAlarmPanel.pdf|11/8/21]]
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Leotek LEDBi-ModalArrows.pdf|TSL-12BM-LD-A1]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[media:TRF PQL TS PHOT Leotek LEDBi-ModalArrow Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDBi-ModalArrow Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Leotek LEDBi-ModalArrow Label.JPG|Label]]
|}
|}
{{PQLNote|Clear Lens, pixilated arrow}}
{{PQLNote|Used only in ATC Cabinet}}


=== Red Ball LED ===
==== Cabinet Monitor Unit (CMU) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,712: Line 1,751:
|-
|-
|
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[[media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|DuraLED 433-1210-003XL]]
|[[Media:TRF PQL TS CAT EDI CMUmodule.pdf|CMUip-2212-HV]]
|[[media:TRF PQL TS MEM Dialight LED.pdf|4/30/10]]
|[[Media:TRF PQL TS MEM EDI CabinetMonitorUnit.pdf|10/16/18]]
|
|[[Media:TRF PQL TS PHOT EDI CMUmodule Front.jpg|Front View]]<br>[[Media:TRF PQL TS PHOT EDI CMUmodule Side.jpg|Side View]]
|-
|}
|
{{PQLNote|Used only in ATC traffic signal cabinet in place of the conflict monitor}}
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/index.jsp GE]
 
|[[media:TRF PQL TS CAT GE LEDBall.pdf|GTX City Series: DR6-RTFB-VLA]]
==== ATC Flasher ====
|[[media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[[media:TRF PQL TS CAT Leotek LEDBall.pdf|TSL-12R-LX-IL6-A1-P3]]
|[[Media:TRF PQL TS CAT EDI HDSwitchPack.pdf|2202-HV]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[Media:TRF PQL TS CAT EDI HDSwitchPack.pdf|10/16/18]]
|[[media:TRF PQL TS PHOT Leotek LEDRedBall Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDRedBall Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Leotek LEDRedBall Label.JPG|Label]]
|[[Media:TRF PQL TS PHOT EDI ATCFlasher Front.jpg|Front View]]<br>[[Media:TRF PQL TS PHOT EDI ATCFlasher Side.jpg|Side View]]
|-
|}
|}
{{PQLNote|Tinted lens<br>Incandescent look}}
{{PQLNote|Used only in ATC Cabinet.<br>Part is also used for the High Density Switch Pack / Load Switch in ATC Cabinet}}


=== Yellow Ball LED ===
==== High Density Flash Transfer Relay ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,741: Line 1,786:
|-
|-
|
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[http://www.struthers-dunn.com/index.html Struthers-Dunn]
|[[media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|DuraLED 433-3230-901XL]]
|[[Media:TRF PQL TS CAT Struthers-Dunn HDFlashTransferRelay.pdf|21XBXHL-48VDC]]
|[[media:TRF PQL TS MEM Dialight LED.pdf|4/30/10]]
|[[Media:TRF PQL TS MEM Struthers-Dunn HDFlashTransferRelay.pdf|10/16/18]]
|
|[[Media:TRF PQL TS PHOT EDI HDSwitchPack Front.jpg|Front View]]<br>[[Media:TRF PQL TS PHOT EDI HDSwitchPack Side.jpg|Side View]]
|-
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/index.jsp GE]
|[[media:TRF PQL TS CAT GE LEDBall.pdf|GTX City Series: DR6-YTFB-VLA]]
|[[media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
|
|-
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Leotek LEDBall.pdf|TSL-12Y-LX-IL6-A1-P3]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[media:TRF PQL TS PHOT Leotek LEDYellowBall Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDYellowBall Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Leotek LEDYellowBall Label.JPG|Label]]
|}
|}
{{PQLNote|Tinted lens<br>Incandescent look}}
{{PQLNote|Used only in ATC Cabinet.}}


=== Green Ball LED ===
==== High Density Switch Pack / Load Switch ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,770: Line 1,803:
|-
|-
|
|
|[http://www.dialight.com/Document/Index/4499!$51#51 DiaLight]
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[[media:TRF PQL TS CAT Dialight LEDBallArrow.pdf|DuraLED 433-2220-001XL]]
|[[Media:TRF PQL TS CAT EDI HDSwitchPack.pdf|2202-HV]]
|[[media:TRF PQL TS MEM Dialight LED.pdf|4/30/10]]
|[[Media:TRF PQL TS CAT EDI HDSwitchPack.pdf|10/16/18]]
|
|
|-
|-  
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/index.jsp GE]
|[[media:TRF PQL TS CAT GE LEDBall.pdf|GTX City Series: DR6-GTFB-VLA]]
|[[media:TRF PQL TS MEM GE LED.pdf|12/8/16]]
|
|-
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Leotek LEDBall.pdf|TSL-12G-LX-IL6-A1-P3]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[media:TRF PQL TS PHOT Leotek LEDGreenBall Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDGreenBall Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Leotek LEDGreenBall Label.JPG|Label]]
|}
|}
{{PQLNote|Tinted lens<br>Incandescent look}}
{{PQLNote|Used only in ATC Cabinet.<br>Part is also used for the Flasher in ATC Cabinet}}


=== Countdown Pedestrian LED ===
==== Serial Interface Unit (SIU) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,799: Line 1,821:
|-
|-
|
|
|[http://www.dialight.com/Product/Details/445162/4306479001X DiaLight]
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[[media:TRF PQL TS CAT Dialight LEDCountdownPed.pdf|430-6479-001X]]
|[[Media:TRF PQL TS CAT EDI SIUmodule.pdf|SIU-2218]]
|[[media:TRF_PQL_TS_MEM_Dialight_LED.pdf|4/30/10]]
|[[Media:TRF PQL TS MEM EDI SerialInterfaceUnit.pdf|10/16/18]]
|
|[[Media:TRF PQL TS PHOT EDI SIUmodule Front.jpg|Front View]]
|-
|
|[http://www.gelighting.com/LightingWeb/na/solutions/transportation-lighting/led-traffic-signals/gtx-city-pedestrian-units.jsp GE]
|[[media:TRF PQL TS CAT GE CountdownPedestrianLED.pdf|GTX City Series: PS7-CFF1-VLA]]
|[[media:TRF_PQL_TS_MEM_GE_LED.pdf|12/8/16]]
|[[media:TRF PQL TS PHOT GE CountdownPedestrianLED FrontView.JPG|Front View]]<br>[[media:TRF PQL TS PHOT GE CountdownPedestrianLED BackView.JPG|Back View]]<br>[[media:TRF PQL TS PHOT GE CountdownPedestrianLED Gasket.JPG|Gasket]]<br>[[media:TRF PQL TS PHOT GE CountdownPedestrianLED CountdownView.JPG|Countdown View]]
|-
|
|[https://leotek.com/traffic-signal-lighting-modules/ Leotek]
|[[media:TRF PQL TS CAT Leotek LEDPedCountdown.pdf|TSL-PED-16-SPC-V1]]
|[[media:TRF PQL TS MEM Leotek LED.pdf|4/3/18]]
|[[media:TRF PQL TS PHOT Leotek LEDPedCountdown Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Leotek LEDPedCountdown Label.JPG|Label]]<br>[[media:TRF PQL TS PHOT Leotek LEDPedCountdown Back.JPG|Back View]]
|}
|}
{{PQLNote|16” X 18” Orange Hand/White Man<br>Incandescent look<br>Filled/Overlay Style<br>9” Numerals}}
{{PQLNote|Only used in ATC Cabinet}}
 
=== General Cabinet Equipment ===


== Loop Sealants ==
==== 1C CPU Module ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,828: Line 1,840:
|-
|-
|
|
|[http://3mcollision.com/bondo-detector-loop-sealant-5000-4-5-gallon-pail-35382.html#moreInfoDetails 3M]
|[https://www.econolite.com/products/controllers/2070-1c/ Econolite]
|[[media:TRF PQL TS CAT 3M LoopSealant.pdf|5000]]
|[[Media:TRF PQL TS CAT Econolite 1CModule.pdf|Model 2070-1C]]
|[[media:TRF PQL TS MEM 3M LoopSealant.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Econolitedoc 1CModule.pdf|2/15/17]]
|
|[[Media:TRF PQL TS PHOT Econolite 1CModule Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Econolite 1CModule Side.JPG|Side View]]
|-
|}
|Purchased by Royal Adhesives & Sealants<br>Under acquisition by HB Fuller
{{PQLNote|For use in upgrading existing 2070 controllers only}}
|[http://www.chemque.com/pages.php?page=Q-Seal Chemque]
 
|[[media:TRF PQL TS CAT Chemque LoopSealant.pdf|Q-Seal 290S - Grey or Black]]
==== AC Isolator ====
|[[media:TRF PQL TS MEM Chemque LoopSealant.pdf|10/23/03]]
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|
|[https://crafco.com/ Crafco Inc]
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[[media:TRF PQL TS CAT Crafco LoopSealant.pdf|RoadSaver 221, Part No. 34221]]
|[[Media:TRF PQL TS CAT GDI ACIsolator.pdf|ACIM252]]
|[[media:TRF PQL TS MEM Crafco LoopSealant.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM GDI ACIsolator.pdf|5/5/03]]
|
|
|-
|-
|
|
|[http://www.ruscoe.com/highway-products/ Ruscoe Highway Products]
|[http://www.pdctraffic.com/products/isolators/ PDC / Power  Distribution & Control]
|[[media:TRF PQL TS CAT Ruscoe LoopSealant.pdf|Permanent Sealer 974 – Gray or Black]]
|[[Media:TRF PQL TS CAT PDC ACIsolator.pdf|ACI-88 Model  252]]
|[[media:TRF PQL TS MEM Ruscoe LoopSealant.pdf|7/3/13]]
|[[Media:TRF PQL TS MEM PDC ACIsolator.pdf|5/5/03]]
|
|
|}
|}
{{PQLNote|Crafco sealant may only be used on loops sawed into the final surface of the pavement.}}
{{PQLNote|Model 252}}
{{PQLReturn}}


== Miscellaneous Controller Equipment ==
==== Auxiliary Output File ====
 
=== ATC Cabinet Specific Equipment ===
 
==== ATC Controller ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,868: Line 1,880:
|-
|-
|
|
|[https://www.mccain-inc.com/ McCain]
|[https://www.mccain-inc.com/ McCain Traffic]
|[[media:TRF PQL TS CAT McCain ATC2070Controller.pdf|ATC eX 2070 PN: M46541]]
|CABSP-1521020033X KS
|[[media:TRF PQL TS CAT McCain ATC2070Controller.pdf|10/16/18]]
|2/26/20
|
|[[Media:TRF PQL TS PHOT McCain AuxiliaryOutputFile Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT McCain AuxiliaryOutputFile Back.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT McCain AuxiliaryOutputFile Top.JPG|Top View]]
|-
|-
|}
|}
{{PQLNote|Used only in ATC Cabinet<br>With Data Key<br>Firmware shall be provided with the controller}}
{{PQLNote|With AC Jumper for 15 Pin Connection}}


==== ATC Cabinet Power Supply ====
==== Conflict Monitor ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,886: Line 1,898:
|-
|-
|
|
|[https://www.editraffic.com/ EDI / Eberle Design Inc]
|[http://www.editraffic.com/traffic-control/ EDI / Eberle Design, Inc.]
|[[media:TRF PQL TS CAT EDI ATCCabinetPowerSupply.pdf|PS-2216-24-HV]]
|[[Media:TRF PQL TS CAT EDI ConflictMonitor.pdf|2018 KCLip – (Std 332 Cabinet) with<br>Datakey programming and Ethernet port]]
|[[media:TRF PQL TS MEM EDI ATCCabinetPowerSupply.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM EDI ConflictMonitor.pdf|2/19/09]]
|
|[[Media:TRF PQL TS PHOT EDI ConflictMonitor FrontView.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT EDI ConflictMonitor SideView.JPG|Side View]]
|}
|}
{{PQLNote|Used only in ATC Cabinet.}}
{{PQLNote|Not used with Hybrid Cabinet.  See “Malfunction Management Unit” below<br>Not used with ATC Cabinet. See “Conflict Management Unit” below}}


==== Auxiliary Display Unit (ADU) ====
==== Controller ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,902: Line 1,914:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|<font color="red">'''For Hybrid Cabinets Only'''</font>
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[http://www.safetran-traffic.com Safetran/Econolite Control Products, Inc.]
|[[media:TRF PQL TS CAT EDI AuxiliaryDisplayUnit.pdf|ADU 2220]]
|[[Media:TRF PQL TS CAT Safetran RackMountATCController.pdf|Model Cobalt-C]]
|[[media:TRF PQL TS MEM EDI AuxiliaryDisplayUnit.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM Safetran RackMountATCController.pdf|2/26/16]]
|
|[[Media:TRF PQL TS PHOT Safetran RackMountATCController FrontView.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Safetran RackMountATCController BackView.JPG|Back View]]
|}
|}
{{PQLNote|Used only in ATC Cabinet}}
{{PQLNote|With Data Key<br>Firmware shall be provided with the controller}}


==== Cabinet Monitor Unit (CMU) ====
==== DC Isolator ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,920: Line 1,932:
|-
|-
|
|
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[https://www.editraffic.com/ EDI]
|[[media:TRF PQL TS CAT EDI CMUmodule.pdf|CMUip-2212-HV]]
|[[Media:TRF PQL TS CAT EDI 242DCIsolator.pdf|242L]]
|[[media:TRF PQL TS MEM EDI CabinetMonitorUnit.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM EDI 242DCIsolator.pdf|10/12/21]]
|[[Media:TRF PQL TS PHOT EDI 242DCIsolator.jpg|Front View]]
|-
|
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[[Media:TRF PQL TS CAT GDI DCIsolator.pdf|DIM242]]
|[[Media:TRF PQL TS MEM GDI DCIsolator.pdf|5/5/03]]
|
|-
|
|
|[http://www.pdctraffic.com/products/isolators/ PDC  / Power Distribution & Control]
|[[Media:TRF PQL TS CAT PDC DCIsolator.pdf|DCI-82  Model 242]]
|[[Media:TRF PQL TS MEM PDC DCIsolator.pdf|5/5/03]]
|[[Media:TRF PQL TS PHOT PDC DCIsolator FrontView.pdf.jpg|Front View]]<br>[[Media:TRF PQL TS PHTO PDC DCIsolator SideView.jpg|Side View]]
|-
|}
|}
{{PQLNote|Used only in ATC traffic signal cabinet in place of the conflict monitor}}
{{PQLNote|Model 242<br>Not used with Hybrid Cabinet.  See “Detector Test Switch Module” below.}}


==== Flasher ====
==== Flash Transfer Relay ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,935: Line 1,960:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|Purchased by EDI
|[https://www.editraffic.com/brands?cat=load-switches-flashers Reno  A&E]
|[[Media:TRF PQL TS CAT Reno FlashTransferRelay.pdf|TR-200]]
|[[Media:TRF PQL TS MEM Reno FlashTransferRelay.pdf|11/3/05]]
|[[Media:TRF PQL TS PHOT Reno FlashTransferRelay.jpg|Side]]<br>[[Media:TRF PQL TS PHOT Reno FlashTransferRelay Back.jpg|Back]]
|-
|-
|
|
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[https://www.struthers-dunn.com/ Struthers-Dunn]
|[[media:TRF PQL TS CAT EDI HDSwitchPack.pdf|2202-HV]]
|[[Media:TRF PQL TS CAT Struthers-Dunn FlashTransferRelay.pdf|W21ACPX-2]]
|[[media:TRF PQL TS CAT EDI HDSwitchPack.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM Struthers-Dunn FlashTransferRelay.pdf|8/6/20]]
|
|[[Media:TRF PQL TS PHOT Struthers-Dunn FlashTransferRelay.jpg|Front]]
|-
|}
|}
{{PQLNote|Used only in ATC Cabinet.<br>Part is also used for the High Density Switch Pack / Load Switch in ATC Cabinet}}
{{PQLNote|Model 430<br>Not used with ATC Cabinet.  See “High Density Flash Transfer Relay” below}}


==== High Density Flash Transfer Relay ====
==== Flasher Unit ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,955: Line 1,985:
|-
|-
|
|
|[http://www.struthers-dunn.com/index.html Struthers-Dunn]
|[http://www.editraffic.com/products-page/model-204-225-2/ EDI / Eberle Design,  Inc.]
|[[media:TRF PQL TS CAT Struthers-Dunn HDFlashTransferRelay.pdf|21XBXHL-48VDC]]
|[[Media:TRF PQL TS CAT EDI FlasherUnit.pdf|EDI 204]]
|[[media:TRF PQL TS MEM Struthers-Dunn HDFlashTransferRelay.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM EDI FlasherUnit.pdf|5/5/03]]
|
|
|}
|-
{{PQLNote|Used only in ATC Cabinet.}}
|
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[[Media:TRF PQL TS CAT GDI FlasherUnit.pdf|FL204]]
|[[Media:TRF PQL TS MEM GDI FlasherUnit.pdf|5/5/03]]
|
|-
|
|[http://www.pdctraffic.com/products/flashers/ PDC / Power Distribution & Control]
|[[Media:TRF PQL TS CAT PDC FlasherUnit.pdf|SSF-88]]
|[[Media:TRF PQL TS MEM PDC FlasherUnit.pdf|5/5/03]]
|
|-
|Purchased by EDI
|[https://www.editraffic.com/brands?cat=load-switches-flashers Reno A&E]
|[[Media:TRF PQL TS CAT Reno FlasherUnit.pdf|FL-200]]
|[[Media:TRF PQL TS MEM Reno FlasherUnit.pdf|11/3/05]]
|
|-
|
|[http://www.tscorp1.com/flashers.htm TSC / Traffic Sensor Corp]
|[[Media:TRF PQL TS CAT TSC FlasherUnit.pdf|TSC 204]]
|[[Media:TRF PQL TS MEM TSC FlasherUnit.pdf|5/5/03]]
|
|}
{{PQLNote|Model 204<br>Not used with ATC Cabinet. See “High Density Switch Pack” below}}


==== High Density Switch Pack / Load Switch ====
==== Power Distribution Assembly (PDA) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,972: Line 2,026:
|-
|-
|
|
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[https://www.mccain-inc.com/ McCain]
|[[media:TRF PQL TS CAT EDI HDSwitchPack.pdf|2202-HV]]
|PDA#2 M63186
|[[media:TRF PQL TS CAT EDI HDSwitchPack.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM McCain PowerDistributionAssembly.pdf|7/14/10]]
|
|
|-  
|-
|}
|}
{{PQLNote|Used only in ATC Cabinet.<br>Part is also used for the Flasher in ATC Cabinet}}


==== Serial Interface Unit (SIU) ====
==== Power Distribution Surge Protection Unit ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 1,988: Line 2,041:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|MTL Instruments Group<br>is the umbrella company
|[https://www.mtl-inst.com/product/rack_pro_range Cooper/Crouse-Hinds/<br>Atlantic Scientific]
|[[Media:TRF PQL TS CAT AtlanticScientific PowerDistrSurgeProtector.pdf|RP35326]]
|[[Media:TRF PQL TS MEM AtlanticScientific PowerDistrSurgeProtector.pdf|10/28/2008]]
|[[Media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Back.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Top.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Lights.JPG|Indicator Lights]]
|-
|-
|
|
|[https://www.editraffic.com/atcc/ EDI / Eberle Design Inc.]
|[http://geistapp.geistglobal.com/specs/1454 Geist Manufacturing, Inc.]
|[[media:TRF PQL TS CAT EDI SIUmodule.pdf|SIU-2218]]
|[[Media:TRF PQL TS CAT Geist PowerDistributionSurgeProtectorUnit.pdf|SPX084-10]]
|[[media:TRF PQL TS MEM EDI SerialInterfaceUnit.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM Geist PowerDistributionSurgeProtectorUnit.pdf|11/4/05]]
|
|
|-
|}
|}
{{PQLNote|Only used in ATC Cabinet}}
{{PQLNote|Room for 4 to 6 transformer spaced outlets on one side and 4 to 6 standard outlets on the other side<br>15 amp breaker<br>Rack mounted<br>NEMA 5-15}}


=== General Cabinet Equipment ===
==== Power Supply ====
 
==== 1C CPU Module ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,009: Line 2,067:
|-
|-
|
|
|[https://www.econolite.com/products/controllers/2070-1c/ Econolite]
|[http://www.editraffic.com/power-supplies-1702070/ EDI]
|[[media:TRF PQL TS CAT Econolite 1CModule.pdf|Model 2070-1C]]  
|[[Media:TRF PQL TS CAT EDI PowerSupply.pdf|Model 206L]]
|[[media:TRF PQL TS MEM Econolitedoc 1CModule.pdf|2/15/17]]
|[[Media:TRF PQL TS MEM EDI PowerSupply.pdf|7/9/10]]
|
|
|-
|}
|}
{{PQLNote|For use in upgrading existing ATC 2070 controllers only}}
{{PQLNote|High efficiency power saving w/ solid state transfer relay}}


==== AC Isolator ====
==== Pre-empt Phase Selectors / Discriminator Module ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,026: Line 2,085:
|-
|-
|
|
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[http://www.gtt.com/ Global Traffic Technologies]
|[[media:TRF PQL TS CAT GDI ACIsolator.pdf|ACIM252]]
|[[Media:TRF PQL TS CAT GTT 2ChannelPhaseSelector.pdf|Model 762 – Two Channel]]<br>[[Media:TRF PQL TS CAT GTT 4ChannelPhaseSelector.pdf|Model 764 – Four Channel]]<br>[[Media:TRF PQL TS CAT GTT EVPAuxiliaryInputFile.pdf|Model 768 Auxiliary Interface Panel]] (If specified)
|[[media:TRF PQL TS MEM GDI ACIsolator.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM GTT PhaseSelectors.pdf|4/19/11]]
|
|[[Media:TRF PQL TS PHOT GTT EVPPhaseSelector 764Card.JPG|764 Phase Selector]]
|-
|
|[http://www.pdctraffic.com/products/isolators/ PDC / Power  Distribution & Control]
|[[media:TRF PQL TS CAT PDC ACIsolator.pdf|ACI-88 Model 252]]
|[[media:TRF PQL TS MEM PDC ACIsolator.pdf|5/5/03]]
|
|}
|}
{{PQLNote|Model 252}}
{{PQLNote|With Ethernet Ports}}


==== Conflict Monitor ====
==== Switchpack / Load Switch ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,047: Line 2,100:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[[Media:TRF PQL TS CAT GDI LoadSwitch.pdf|LS200-6]]
|[[Media:TRF PQL TS MEM GDI LoadSwitch.pdf|5/5/03]]
|
|-
|
|[https://www.pdctraffic.com PDC / Power  Distribution & Control]
|[[Media:TRF PQL TS CAT PDC LoadSwitch.pdf|SSS-87IO]]
|[[Media:TRF PQL TS MEM PDC LoadSwitch.pdf|5/5/03]]
|[[Media:TRF PQL TS PHOT PDC LoadSwitch.jpg|Front View]]<br>[[Media:TRF PQL TS PHOT PDC LoadSwitch Side.jpg|Side View]]
|-
|-
|Purchased by EDI
|[http://www.renoae.com/ Reno  A&E]
|[[Media:TRF PQL TS CAT Reno LoadSwitch.pdf|LS-200]]
|[[Media:TRF PQL TS MEM Reno LoadSwitch.pdf|11/3/05]]
|[[Media:TRF PQL TS PHOT Reno LoadSwitch Front.JPG|Front View]]<br>
[[Media:TRF PQL TS PHOT Reno LoadSwitch Side.JPG|Side View]]<br>
[[Media:TRF PQL TS PHOT Reno LoadSwitch Back.jpg|Back View]]<br>
[[Media:TRF PQL TS PHOT Reno LoadSwitch End.JPG|End View]]<br>
[[Media:TRF PQL TS PHOT Reno LoadSwitch Label.jpg|Label]]
|-
|
|[http://www.tscorp1.com/index.html TSC / Traffic  Sensor Corp]
|[[Media:TRF PQL TS CAT TSC LoadSwitch.pdf|TSC200]]
|[[Media:TRF PQL TS MEM TSC LoadSwitch.pdf|5/5/03]]
|
|
|[http://www.editraffic.com/traffic-control/ EDI / Eberle Design, Inc.]
|[[media:TRF PQL TS CAT EDI ConflictMonitor.pdf|2018 KCLip – (Std 332 Cabinet) with<br>Datakey programming and Ethernet port]]
|[[media:TRF PQL TS MEM EDI ConflictMonitor.pdf|2/19/09]]
|[[media:TRF PQL TS PHOT EDI ConflictMonitor FrontView.JPG|Front View]]<br>[[media:TRF PQL TS PHOT EDI ConflictMonitor SideView.JPG|Side View]]
|}
|}
{{PQLNote|Not used with Hybrid Cabinet.  See “Malfunction Management Unit” below<br>Not used with ATC Cabinet.  See “Conflict Management Unit” below}}
{{PQLNote|Model 200 with Input and Output monitoring<br>Not used with ATC Cabinet.  See “High Density Switch Pack” above}}


==== Controller ====
==== Surge Protector (Traffic Signal Cabinet) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,065: Line 2,140:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|<font color="red">'''For Hybrid and 332 Cabinets'''</font>
|
|[http://www.safetran-traffic.com Safetran/Econolite Control Products, Inc.]
|[http://www.emerson.com/en-US/Pages/Default.aspx Edco/Emerson Network Power]
|[[media:TRF PQL TS CAT Safetran RackMountATCController.pdf|Model Cobalt-C]]
|[[media:TRF PQL TS CAT Edco CabinetSurgeProtector.pdf|SHA-1250 w/ SHA-1250-BASE-A]]
|[[media:TRF PQL TS MEM Safetran RackMountATCController.pdf|2/26/16]]
|[[media:TRF PQL TS MEM Edco CabinetSurgeProtector.pdf|8/5/10]]
|[[media:TRF PQL TS PHOT Safetran RackMountATCController FrontView.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Safetran RackMountATCController BackView.JPG|Back View]]
|
|}
|-
{{PQLNote|With Data Key<br>Firmware shall be provided with the controller}}
|
|[http://www.hescorls.com/ Hesco/RLS]
|[[media:TRF PQL TS CAT Hesco CabinetSurgeProtection.pdf|HE1750]]
|[[media:TRF PQL TS MEM Hesco CabinetSurgeProtection.pdf|10/16/18]]
|
|-
{{PQLNote|For Hybrid, 332 and ATC Cabinets}}


==== DC Isolator ====
==== Utility Power Surge Protector (Secondary Service Enclosure) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,082: Line 2,163:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|Partners with Pentair Engineered<br>Electrical & Fastening Systems
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[http://www.erico.com/products.asp?folderID=42 Nvent/Erico / Critec]
|[[media:TRF PQL TS CAT GDI DCIsolator.pdf|DIM242]]
|[[Media:TRF PQL TS CAT Erico UtilityPowerSurgeProtector.pdf|TDX-100S120240]]
|[[media:TRF PQL TS MEM GDI DCIsolator.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Erico UtilityPowerSurgeProtector.pdf|11/26/14]]
|
|[[Media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector TopView.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector PullOutInterior.JPG|Pull Out Drawer]]<br>[[Media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector TopInsideView.JPG|Top Inside View]]<br>[[Media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector ReplacementModule.JPG|Replacement Module]]
|}
{{PQLNote|Note:  NEMA-4 weather tight housing<br>Output contacts<br>Replaceable cartridge overcurrent fuse protection<br>Replaceable modules<br>Event timer}}
{{PQLReturn}}
 
=== Hybrid Cabinet Specific Equipment ===
 
==== Bus Interface Unit (BIU) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|<font color="red">Maintenance Use Only</font>
|[https://www.editraffic.com/ EDI / Eberle Design Inc.]
|[[Media:TRF PQL TS CAT EDI BIU.pdf|BIU-700H]]
|[[Media:TRF PQL TS MEM EDI BIU.pdf|10/17/18]]
|
|
|[http://www.pdctraffic.com/products/isolators/ PDC  / Power Distribution & Control]
|[[media:TRF PQL TS CAT PDC DCIsolator.pdf|DCI-82  Model 242]]
|[[media:TRF PQL TS MEM PDC DCIsolator.pdf|5/5/03]]
|[[media:TRF PQL TS PHOT PDC DCIsolator FrontView.pdf.jpg|Front View]]<br>[[media:TRF PQL TS PHTO PDC DCIsolator SideView.jpg|Side View]]
|-
|-
|<font color="red">Maintenance Use Only</font>
|[http://www.econolite.com/ Econolite]
|160-1003-505
|[[Media:TRF PQL TS MEM Safetran BIU.pdf|10/6/11]]
|[[Media:TRF PQL TS PHOT Safetran BIU Card front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Safetran BIU Side.JPG|Side View]]
|}
|}
{{PQLNote|Model 242<br>Not used with Hybrid Cabinet.  See “Detector Test Switch Module” below.}}
{{PQLNote|½ width design - Only used with Hybrid Cabinet}}


==== Flash Transfer Relay ====
==== Malfunction Management Unit (MMU) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,106: Line 2,206:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|CII was acquired by Tyco Electronics
|<font color="red">Maintenance Use Only</font>
|[https://www.te.com/usa-en/products/relays-contactors-switches/relays.html CII Technologies /  MidTex]
|[http://www.editraffic.com/ EDI / Eberle Design Inc.]
|MidTex 136-62T3A1
|[[Media:TRF PQL TS CAT EDI MMU.pdf|MMU2-16-LE(ip)]]
|[[media:TRF PQL TS MEM MidTex FlashTransferRelay.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM EDI MMU.pdf|1/10/13]]
|
|[[Media:TRF PQL TS PHOT EDI MMU Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT EDI MMU Back.JPG|Back View]]
|-
|
|Magnecraft
|W21ACPX-2
|[[media:TRF PQL TS MEM Magnecraft FlashTransferRelay.pdf|5/5/03]]
|
|-
|
|[http://www.renoae.com/product/root/0/120 Reno  A&E]
|[[media:TRF PQL TS CAT Reno FlashTransferRelay.pdf|TR-200]]
|[[media:TRF PQL TS MEM Reno FlashTransferRelay.pdf|11/3/05]]
|
|}
|}
{{PQLNote|Model 430<br>Not used with ATC Cabinet.  See “High Density Flash Transfer Relay” below}}
{{PQLNote|Only used in Hybrid traffic signal cabinet in place of the conflict monitor}}


==== Flasher Unit ====
==== K1 Control Relay ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,135: Line 2,223:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|<font color="red">Maintenance Use Only</font>
|[http://www.editraffic.com/products-page/model-204-225-2/ EDI / Eberle Design,  Inc.]
|[http://www.econolite.com/ Econolite]
|[[media:TRF PQL TS CAT EDI FlasherUnit.pdf|EDI 204]]
|[[Media:TRF PQL TS CAT Econolite K1ControlRelay.pdf|Dwg No. 54408 Rev U]]
|[[media:TRF PQL TS MEM EDI FlasherUnit.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Econolite K1ControlRelay.pdf|4/6/15]]
|
|
|-
|-
|
|<font color="red">Maintenance Use Only</font>
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[http://www.te.com/en/home.html Tyco Electronics /<br>Potter & Brumfield]
|[[media:TRF PQL TS CAT GDI FlasherUnit.pdf|FL204]]
|[[Media:TRF PQL TS CAT TycoElectronics K1ControlRelay.pdf|KRPA-14AGP-120]]
|[[media:TRF PQL TS MEM GDI FlasherUnit.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM Tycoelectronics K1ControlRelay.pdf|2/10/11]]
|
|[[Media:TRF PQL TS PHOT TycoElectronics K1ControlRelay.jpg|Side View]]
|-
|
|[http://www.pdctraffic.com/products/flashers/ PDC / Power Distribution & Control]
|[[media:TRF PQL TS CAT PDC FlasherUnit.pdf|SSF-88]]
|[[media:TRF PQL TS MEM PDC FlasherUnit.pdf|5/5/03]]
|
|-
|
|[http://www.renoae.com/product/root/0/69 Reno A&E]
|[[media:TRF PQL TS CAT Reno FlasherUnit.pdf|FL-200]]
|[[media:TRF PQL TS MEM Reno FlasherUnit.pdf|11/3/05]]
|
|-
|
|[http://www.tscorp1.com/flashers.htm TSC / Traffic Sensor Corp]
|[[media:TRF PQL TS CAT TSC FlasherUnit.pdf|TSC 204]]
|[[media:TRF PQL TS MEM TSC FlasherUnit.pdf|5/5/03]]
|
|}
|}
{{PQLNote|Model 204<br>Not used with ATC Cabinet.  See “High Density Switch Pack” below}}
{{PQLNote|Only used with Hybrid Cabinet}}
{{PQLReturn}}
 
== Mounting Brackets ==


==== Power Distribution Assembly (PDA) ====
=== Mast Arm Signal Head Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,177: Line 2,250:
|-
|-
|
|
|McCain
|[https://www.pelcoinc.com/ Pelco]
|PDA#2 M63186
|[[Media:TRF PQL TS CAT Pelco VehicleHeadMastArmSignalBracket.pdf|AG-0125-1-LL-PXX (1-Section)<br>AG-0125-3-LL-PXX (3-Section)<br>AG-0125-4-LL-PXX (4-Section)]]<br><br>[[Media:TRF PQL TS CAT Pelco HAWKSignalMastArmBracket.pdf|AG-0168-LL-PXX (HAWK)]]
|[[media:TRF PQL TS MEM McCain PowerDistributionAssembly.pdf|7/14/10]]
|[[Media:TRF PQL TS MEM Pelco VehicleHeadMastArmSignalBracket.pdf|4/19/19]]<br><br><br><br><br><br><br>[[Media:TRF PQL TS MEM Pelco HAWKSignalMastArmBracket.pdf|4/19/19]]
|
|[[Media:TRF PQL TS PHOT Pelco MastArmMountingBracket Hinge.JPG|Open Hinge View]]<br>[[Media:TRF PQL TS PHOT Pelco MastArmMountingBracket TopView.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT Pelco MastArmMountingBracket SideView.JPG|Side View]]
|-
|A Division<br>of Olson<br>Aluminum<br>Castings
|[http://www.skybracket.com/ Sky Bracket]
|[[Media:TRF PQL TS CAT SkyBracket SignalHeadMountingBracket.pdf|SS-SBLL-18 (1-Section)<br>SS-SBLL-46 (3-Section)<br>SS-SBLL-60 (4-Section)]]<br><br>[[Media:TRF PQL TS CAT SkyBracket HAWKMastArmBracket.pdf|SS-SBLL_HPB-18 (HAWK)]]
|[[Media:TRF PQL TS MEM SkyBracket MastArmMountingBracket.pdf|1/11/19]]<br><br><br><br>[[Media:TRF PQL TS MEM SkyBracket HAWKMastArmBracket.pdf|1/11/19]]
|Shown with previously approved cable mounting system.<br>[[Media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketBack.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket LowerArmTube.JPG|Lower Arm]]<br>[[Media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket Upper ArmTube.JPG|Upper Arm]]<br>[[Media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket TubeCrossSection.JPG|Tube Section]]
|-
|-
|
|SafeTran
|
|
|
|}
|}
{{PQLNote|Stainless steel banding/cable and hardware<br><u>For Pelco:</u><br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>62" – for mast arm diameters ranging from 2” to 7”<br>84" – for mast arm diameters ranging from 7.1” to 10.5”<br>96" – for mast arm diameters ranging from 10.6” to 12.4”<br>110" – for mast arm diameters ranging from 12.5” to 14.6”<br>120" – for mast arm diameters ranging from 14.7” to 16.2”<br>132" – for mast arm diameters ranging from 16.3” to 18.2”<br>Color (XX) shall be as follows:<br>NC - No Color<br>33 - Glossy Black<br>71 - RAL6012 Green<br>39 - RAL8019 Dark Bronze<br><u>For Sky Bracket:</u><br>Required band length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>29” – for mast arm diameters ranging from 2” to 7”<br>42” – for mast arm diameters ranging from 8” to 11”<br>59” – for mast arm diameters ranging from 12” to 17”<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}


==== Power Distribution Surge Protection Unit ====
=== Mini Pre-empt Detector Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,197: Line 2,272:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|MTL Instruments Group<br>is the umbrella company
|[http://www.mtl-inst.com/product/rack_pro_series/ Cooper/Crouse-Hinds/<br>Atlantic Scientific]
|[[media:TRF PQL TS CAT AtlanticScientific PowerDistrSurgeProtector.pdf|RP35326]]
|[[media:TRF PQL TS MEM AtlanticScientific PowerDistrSurgeProtector.pdf|10/28/2008]]
|[[media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT AtlanticScientific PowerDistrSurgeProtector Lights.JPG|Indicator Lights]]
|-
|-
|
|
|[http://geistapp.geistglobal.com/specs/1454 Geist Manufacturing, Inc.]
|[https://www.pelcoinc.com/ Pelco Products, Inc.]
|[[media:TRF PQL TS CAT Geist PowerDistributionSurgeProtectorUnit.pdf|SPX084-10]]
|<u>Band Mount</u><br>[[Media:TRF PQL TS CAT Pelco EVPDetectorBandingMountingBracket.pdf|Astro Brac AB-0155-LL-PXX]]<br><u>Cable Mount</u><br>[[Media:TRF PQL TS CAT Pelco EVPDetectorCableMountingBracket.pdf|Astro Brac AB-0163-LL-PXX]]
|[[media:TRF PQL TS MEM Geist PowerDistributionSurgeProtectorUnit.pdf|11/4/05]]
|[[Media:TRF PQL TS MEM Pelco EVPDetectorBandingMountingBracket.pdf|1/11/19]]<br><br>[[Media:TRF PQL TS MEM Pelco EVPDetectorCableMountingBracket.pdf|12/29/04]]
|
|
|-
|-
|
|[http://www.skybracket.com/ Sky Bracket]
|[[Media:TRF PQL TS CAT SkyBracket EVPMountingBracket.PDF|SBLL-MM-075]]
|[[Media:TRF PQL TS MEM SkyBracket EVPMountingBracket.pdf|11/25/19]]
|[[Media:TRF PQL TS PHOT SkyBracket EVPMountingBracket Back.JPG|Back]]<br>
[[Media:TRF PQL TS PHOT SkyBracket EVPMountingBracket BackAngle.JPG|Back Angle]]<br>
[[Media:TRF PQL TS PHOT SkyBracket EVPMountingBracket Front.JPG|Front]]<br>
|}
|}
{{PQLNote|Room for 8 transformer spaced outlets (minimum)<br>15 amp breaker<br>Rack mounted<br>NEMA 5-15}}
{{PQLNote|Stainless Steel banding or cable mount<br><u>LL &#x003D; Banding Length Based on Mast Arm Diameter:</u><br>29” – for mast arm diameters ranging from 2” to 7”<br>42" – for mast arm diameters ranging from 8” to 11”<br>59" – for mast arm diameters ranging from 12” to 17)<br><u>LL &#x003D; Cable Length Based on Mast Arm Diameter:</u><br>45" - for mast arm diameters ranging from 2" to 11"<br>62" - for mast arm diameters ranging from 11.1" to 16.6"<br>84" - for mast arm diameters ranging from 16.7" to 22"<br><u>Color (XX) shall be as follows:</u><br>NC - No Color<br>33 - Glossy Black<br>71 - RAL6012 Green<br>39 - RAL8019 Dark Bronze}}


==== Power Supply ====
=== Radar Detector Mounting Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,222: Line 2,298:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|For a ''Presence'' sensor<br>mounted on a mast arm.<br>For an ''Advance'' sensor<br>mounted on a mast arm.
|[http://www.editraffic.com/power-supplies-1702070/ EDI]
|[https://www.pelcoinc.com/ Pelco Inc.]
|[[media:TRF PQL TS CAT EDI PowerSupply.pdf|Model 206L]]
|[[Media:TRF PQL TS CAT Pelco RadarDetectorMountingBracket.pdf|SP-5987-23-LL-PXX]]
|[[media:TRF PQL TS MEM EDI PowerSupply.pdf|7/9/10]]
|[[Media:TRF PQL PS MEM Pelco RadarDetectorMountingBracket.pdf|8/6/19]]
|
|[[Media:TRF PQL TS PHOT Pelco MastArmMountingBracket Hinge.JPG|Open Hinge View]]<br>[[Media:TRF PQL TS PHOT Pelco MastArmMountingBracket TopView.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT Pelco MastArmMountingBracket SideView.JPG|Side View]]
|-
|For a ''Presence'' sensor<br>mounted on a mast arm.<br>For an ''Advance'' sensor<br>mounted on a mast arm.
|[http://www.skybracket.com/ Sky Bracket]
|[[Media:TRF PQL TS CAT SkyBracket RadarDetectorMountingBracket.pdf|Bracket:<br>SS-SBLL-ACM-24]]<br>[[Media:TRF PQL TS CAT SkyBracket RadarDetectorMountingAdaptor.pdf|Burle Style Adapter Plate: SB-PLT]]
|[[Media:TRF PQL TS MEM SkyBracket RadarDetectorMountingBracket.pdf|1/11/19]]
|Showing previously<br>approved cable<br>mounting system.<br>[[Media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketBack.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT SkyBracket RadarMountingBracket End.JPG|Mounting End]]<br>[[Media:TRF PQL TS PHOT SkyBracket RadarMountingBracket TubeCrossSection.JPG|Tube Section]]
|-
|-
|For a ''Presence'' sensor<br>mounted on a vertical pole.<br>For an ''Advance'' sensor<br>mounted on a mast arm or a vertical pole.
|[http://www.wavetronix.com/en Wavetronix]
|[[Media:TRF PQL TS CAT Wavetronixr RadarDetectorMountingBracket.pdf|WX-SS-611]]
|[[Media:TRF PQL TS MEM Wavetronixr RadarDetectorMountingBracket.pdf|4/29/16]]
|[[Media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Top.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Side.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Connection.JPG|Connection Segments]]
|}
|}
{{PQLNote|High efficiency power saving w/ solid state transfer relay}}
{{PQLNote|Stainless steel banding/cable and hardware<br><u>For Pelco:</u><br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>62" – for mast arm diameters ranging from 2” to 7”<br>84" – for mast arm diameters ranging from 7.1” to 10.5”<br>96" – for mast arm diameters ranging from 10.6” to 12.4”<br>110" – for mast arm diameters ranging from 12.5” to 14.6”<br>120" – for mast arm diameters ranging from 14.7” to 16.2”<br>132" – for mast arm diameters ranging from 16.3” to 18.2”<br>Color (XX) shall be as follows:<br>NC - No Color<br>33 - Glossy Black<br>71 - RAL6012 Green<br>39 - RAL8019 Dark Bronze<br><u>For SkyBracket:</u><br>Required banding length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>29” – for mast arm diameters ranging from 2” to 7”<br>42” – for mast arm diameters ranging from 8” to 11”<br>59” – for mast arm diameters ranging from 12” to 17”<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}


==== Pre-empt Phase Selectors / Discriminator Module ====
=== Side Mount Signal Head and Pedestrian Signal Head Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,241: Line 2,328:
|-
|-
|
|
|[http://www.gtt.com/ Global Traffic Technologies]
|Auto/Eagle
|[[media:TRF PQL TS CAT GTT 2ChannelPhaseSelector.pdf|Model 762 – Two Channel]]<br>[[media:TRF PQL TS CAT GTT 4ChannelPhaseSelector.pdf|Model 764 – Four Channel]]<br>[[media:TRF PQL TS CAT GTT EVPAuxiliaryInputFile.pdf|Model 768 Auxiliary Interface Panel]] (If specified)
|UKS-1452X
|[[media:TRF PQL TS MEM GTT PhaseSelectors.pdf|4/19/11]]
|5/5/03
|[[media:TRF PQL TS PHOT GTT EVPPhaseSelector 764Card.JPG|764 Phase Selector]]
|
|}
|-
{{PQLNote|With Ethernet Ports}}
|
 
|[http://componentproducts.com/ Component Products, Inc.]
==== Switchpack / Load Switch ====
|TSP880-X
|5/5/03
|
|-
|
|Gades
|UKS1452X / PDM-405
|5/5/03
|
|}
{{PQLNote|Yellow polycarbonate<br>X&#x003D;Y for Yellow<br>X&#x003D; B for Black}}
 
{{PQLReturn}}
 
== Poles ==
=== Aluminum Pedestal Poles ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,258: Line 2,360:
|-
|-
|
|
|[https://www.editraffic.com/ EDI / Eberle Design, Inc.]
|[http://componentproducts.com/ Component Products, Inc]
|[[media:TRF PQL TS CAT EDI LoadSwitch.pdf|EDI 200]]
|[[Media:TRF PQL TS CAT ComponentProducts PedestalPoleBase.pdf|Square Pedestal Base: CPI-BAS-1-P]]<br>
|[[media:TRF PQL TS MEM EDI LoadSwitch.pdf|5/5/03]]
[[Media:TRF PQL TS CAT ComponentProducts PedestalPoleCap.pdf|Pole Cap: CPI-APC-1]]<br>
|
[[Media:TRF PQL TS CAT ComponentProducts PedestalPoleShaft.pdf|9’ Pedestal Pole: CPI-AP-9-40<br>13’ Pedestal Pole: CPI-AP-13-40<br>14’ Pedestal Pole: CPI-AP-14-40]]<br>
|-
[[Media:TRF PQL TS CAT ComponentProducts PedestalPoleCollar.pdf|Base Collar: CPI-RBC-1]]
|
|[[Media:TRF PQL TS MEM ComponentProducts PedestalPole&Base.pdf|4/24/14]]
|[http://www.sgdi.com/gdi_2013_web_site_020.htm GDI Communications]
|[[Media:TRF PQL TS PHOT ComponentProducts PedestalPoleBase.jpg|Base]]
|[[media:TRF PQL TS CAT GDI LoadSwitch.pdf|LS200]]
|-
|[[media:TRF PQL TS MEM GDI LoadSwitch.pdf|5/5/03]]
|
|-
|
|[https://www.pdctraffic.com PDC / Power  Distribution & Control]
|[[media:TRF PQL TS CAT PDC LoadSwitch.pdf|SSS-88]]
|[[media:TRF PQL TS MEM PDC LoadSwitch.pdf|5/5/03]]
|
|
|[http://www.gadestraffic.com/ Gades Sales]
|[[Media:TRF PQL TS CAT GadesSales PedestalPoleBase.pdf|Square Pedestal Base: PB-5335-1S-GL-PNC]]<br>
[[Media:TRF PQL TS CAT GadesSales PedestalPoleCap.pdf|Pole Cap: PB-5402-PNC]]<br>
[[Media:TRF PQL TS CAT GadesSales PedestalPoleShaft.pdf|9’ Pedestal Pole: PB5100-9-PNC<br>13’ Pedestal Pole: PB5100-13-PNC<br>14’ Pedestal Pole: PB5100-14-PNC]]<br>
[[Media:TRF PQL TS CAT GadesSales PedestalPoleCollar.pdf|Base Collar: PB-5325-PNC]]
|[[Media:TRF PQL TS MEM GadesSales PedestalPole&Base.pdf|4/24/14]]
|[[Media:TRF PQL TS PHOT GadesSales PedestrianPoleBase Side.jpg|Side View]]<br>[[Media:TRF PQL TS PHOT GadesSales PedestrianPoleBase Bottom.jpg|Bottom View]]<br>[[Media:TRF PQL TS PHOT GadesSales PedestrianPoleBase PipeThreads.jpg|Threaded Opening]]<br>[[Media:TRF PQL TS PHOT GadesSales PedestrianPoleBase Cover.jpg|Cover]]
|-
|-
|
|
|[http://www.renoae.com/ Reno  A&E]
|[http://www.pelcoinc.com/ Pelco Products, Inc.]
|[[media:TRF PQL TS CAT Reno LoadSwitch.pdf|LS-200]]
|[[Media:TRF PQL TS CAT Pelco PedestalPoleBase.pdf|Square Pedestal Base: PB-5335-1S-GL-PNC]]<br>
|[[media:TRF PQL TS MEM Reno LoadSwitch.pdf|11/3/05]]
[[Media:TRF PQL TS CAT Pelco PedestalPoleCap.pdf|Pole Cap: PB-5402-PNC]]<br>
|[[media:TRF PQL TS PHOT Reno LoadSwitch Front.JPG|Front View]]<br>
[[Media:TRF PQL TS CAT Pelco PedestalPoleShaft.pdf|9’ Pedestal Pole: PB-5100-9-PNC<br>13’ Pedestal Pole: PB-5100-13-PNC<br>14’ Pedestal Pole: PB-5100-14-PNC]]<br>
[[media:TRF PQL TS PHOT Reno LoadSwitch Side.JPG|Side View]]<br>
[[Media:TRF PQL TS CAT Pelco PedestalPoleCollar.pdf|Base Collar: PB-5325-PNC]]
[[media:TRF PQL TS PHOT Reno LoadSwitch Back.jpg|Back View]]<br>
|[[Media:TRF PQL TS MEM Pelco PedestalPole&Base.pdf|4/23/14]]
[[media:TRF PQL TS PHOT Reno LoadSwitch End.JPG|End View]]<br>
|[[Media:TRF PQL TS PHOT Pelco PedestalPole&Base.jpg|Base]]<br>[[Media:TRF PQL TS PHOT Pelco PedestalPoleBase&Collar.JPG|Base & Collar]]
[[media:TRF PQL TS PHOT Reno LoadSwitch Label.jpg|Label]]
|-
|
|[http://www.tscorp1.com/index.html TSC / Traffic  Sensor Corp]
|[[media:TRF PQL TS CAT TSC LoadSwitch.pdf|TSC200]]
|[[media:TRF PQL TS MEM TSC LoadSwitch.pdf|5/5/03]]
|
|}
|}
{{PQLNote|Model 200<br>Not used with ATC Cabinet.  See “High Density Switch Pack” above}}
{{PQLNote|See "Anchor Bolts" for part number information<br>Pole tube is schedule 40<br>Include base collar with every pole<br>Set screws required in base collar<br>Include 2 7/8” OD x 7/8” ID galvanized flat washers<br>Include anchor bolts}}


==== Surge Protector (Traffic Signal Cabinet) ====
=== Galvanized Steel Signal Poles ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,303: Line 2,398:
|-
|-
|
|
|[http://www.emerson.com/en-US/Pages/Default.aspx Edco/Emerson Network Power]
|[http://www.millerberndmfg.com/ Millerbernd Manufacturing Company]
|[[media:TRF PQL TS CAT Edco CabinetSurgeProtector.pdf|SHA-1250 w/ SHA-1250-BASE-A]]
|1994 AASHTO: [[Media:TRF PQL TS CAT Millerbernd MastArmPoles1994.pdf|780B661]]<br>2013 AASHTO: [[Media:TRF PQL TS CAT Millerbernd MastArmPole.pdf| 780B1885 Rev D]]<br>Identification Label:  [[Media:TRF PQL TS CAT Millerbernd MastArmPoleLabel.pdf|Single Arm]]  :  [[Media:TRF PQL TS CAT Millerbernd MastArmPoleLabel2.pdf|Double Arm]]
|[[media:TRF PQL TS MEM Edco CabinetSurgeProtector.pdf|8/5/10]]
|[[Media:TRF PQL TS MEM Millerbernd MastArmPoles1994.pdf|8/10/10]]<br>[[Media:TRF PQL TS MEM Millerbernd MastArmPoles.pdf|11/10/14]]
|
|
|-
|-
|
|
|[http://www.hescorls.com/ Hesco/RLS]
|[http://www.unionmetal.com/ Union Metal]
|[[media:TRF PQL TS CAT Hesco CabinetSurgeProtection.pdf|HE1750]]
|1994 AASHTO: [[Media:TRF PQL TS CAT UnionMetal GalvanizedSignalMastArmPoles.pdf|50915-B1 Rev 9]]<br>2013 AASHTO: [[Media:TRF PQL TS CAT UnionMetal GalvanizedSteelSignalPole.pdf|50915-B19 Rev 6.1]]
|[[media:TRF PQL TS MEM Hesco CabinetSurgeProtection.pdf|10/16/18]]
|[[Media:TRF PQL TS MEM UnionMetal GalvanizedSignalMastArmPoles.pdf|10/27/04]]<br>[[Media:TRF PQL TS MEM UnionMetal GalvanizedSignalPole.pdf|8/31/15]]
|
|
|-
|-
{{PQLNote|For Hybrid, 332 and ATC Cabinets}}
|
|[http://www.valmont.com/ Valmont]
|1994 AASHTO: [[Media:TRF PQL TS CAT 1994AASHTOValmont MastArmPoles.pdf|DB00175 Rev E]]<br>2013 AASHTO: [[Media:TRF PQL TS CAT Valmont GalvanizedSteelSignalPole.pdf|DB01086 Rev H]]
|[[Media:TRF PQL TS MEM 1994AASHTOValmont MastArmPoles.pdf|1/26/12]]<br>[[Media:TRF PQL TS MEM Valmont GalvanizedSignalPole.pdf|7/28/14]]
|
|}
|}
{{PQLNote|See "Anchor Bolts" for part number information<br>Shall meet 2013 AASHTO Criteria unless otherwise specified in the bid plans, documents and details<br> 2013 AASHTO criteria is for a 50-year recurrence interval, fatigue category 2 but does not include design to resist galloping or truck induced gusts }}


==== Utility Power Surge Protector (Secondary Service Enclosure) ====
=== Pedestrian Pushbutton Pole and Foundation ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,326: Line 2,426:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|Partners with Pentair Engineered<br>Electrical & Fastening Systems
|
|[http://www.erico.com/products.asp?folderID=42 Erico / Critec]
|[http://www.freymfgcorp.com Frey Manufacturing Corp.]
|[[media:TRF PQL TS CAT Erico UtilityPowerSurgeProtector.pdf|TDX-100S120240]]
|<u>Pedestrian Pushbutton Pole with Pole Cap:</u><br>[[Media:TRF PQL TS CAT FreyMfg PedestrianPushbuttonPole.pdf|CP6ACT4840TCSS / Dwg No. 8.1.0 Rev. 1]]<br><u>Pedestrian Pushbutton Pole Cap:</u><br>[[Media:TRF PQL TS CAT FreyMfg PedestrianPushbuttonPoleCap.pdf|TCSS Top Cap with Set Screws for 4" Pipe / Dwg No. 8.4.1 Rev. 1]]
|[[media:TRF PQL TS MEM Erico UtilityPowerSurgeProtector.pdf|11/26/14]]
|[[Media:TRF PQL TS MEM FreyMfg CrosswalkPedestal.pdf|11/30/17]]
|[[media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector TopView.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector PullOutInterior.JPG|Pull Out Drawer]]<br>[[media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector TopInsideView.JPG|Top Inside View]]<br>[[media:TRF PQL TS PHOT Erico UtilityPowerSurgeProtector ReplacementModule.JPG|Replacement Module]]
|[[Media:TRF PQL TS CAT FreyMfg PedestrianPoleShortDemo.JPG|Pedestrian Pole]]<br>[[Media:TRF PQL TS CAT FreyMfg BreakawayBase.JPG|Breakaway Base]]<br>[[Media:TRF PQL TS CAT FreyMfg BreakawayBase2.JPG|Breakaway Base Angle]]<br>[[Media:TRF PQL TS CAT FreyMfg PedestalDoor..JPG|Pedestal Door]]<br>[[Media:TRF PQL TS CAT FreyMfg PoleCap.JPG|Pole Cap]]<br>[[Media:TRF PQL TS CAT FreyMfg Bolts.JPG|Bolts]]
|}
|}
{{PQLNote|Note:  NEMA-4 weather tight housing<br>Output contacts<br>Replaceable cartridge overcurrent fuse protection<br>Replaceable modules<br>Event timer}}
{{PQLNote|Frey Mfg pole requires approved Two-Part Epoxy.
{{PQLReturn}}
}}


=== Hybrid Cabinet Specific Equipment ===
== Power Backup Systems ==
=== CNG Generators ===


==== Bus Interface Unit (BIU) ====
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,347: Line 2,447:
|-
|-
|
|
|[https://www.editraffic.com/ EDI / Eberle Design Inc.]
|[http://www.alpha.ca/web2/index.php Alpha Technologies]
|[[media:TRF PQL TS CAT EDI BIU.pdf|BIU-700H]]
|AlphaGen CE-3x2-50-48 NG with Cold Weather Starting Kit<br>With PCC-3x  Polymer Concrete Pre-Cast Pad<br>Includes Alpha supplied battery<br><br><font color="red">'''DO NOT PROVIDE WITH TRANSFORMER  AND FUSE'''</font>
|[[media:TRF PQL TS MEM EDI BIU.pdf|10/17/18]]
|6/17/03
|
|-
|
|
|[http://www.econolite.com/ Econolite]
|160-1003-505
|[[media:TRF PQL TS MEM Safetran BIU.pdf|10/6/11]]
|[[media:TRF PQL TS PHOT Safetran BIU Card front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Safetran BIU Side.JPG|Side View]]
|}
|}
{{PQLNote|½ width design - Only used with Hybrid Cabinet}}
{{PQLNote|48V DC output voltage<br>96 amp max DC output current<br>10.5 Hp single OHV engine<br>13.5 VDC Ignition Charger Voltage<br>6 amp max Ignition Charger Current<br>2800 to 3600 RPM variable speed<br>80 CuFt/hr Natural Gas, 1000 BTU/CuFt<br>0.5 – 2 PSI Gas Inlet Pressure}}


==== Malfunction Management Unit (MMU) ====
=== UPS Systems ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,368: Line 2,462:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|SPO-09A2 may have been superseded with the SPO-09A3 per contractor email on 11/7/2023.
|[http://www.clary.com/products/traffic-its/sp-series/sp1250lx#downloads Clary]
|[[Media:TRF PQL TS CAT Clary BatteryBackupUPS.pdf|Stand Alone Battery  Backup /UPS Unit<br>SP 1250-LX-R – Uninterruptible Traffic System with  Integrated PIM and Programmable Display<br>SPO-09A2 – SNMP Adapter with cables manual and software<br>SPD-302C – Bypass Switch with GFCI and Generator Plug<br>SP-19N1 – Battery Cable<br>72-volt system]]
|[[Media:TRF PQL TS MEM Clary BatteryBackupUPS.pdf|9/26/13]]
|[[Media:TRF PQL TS PHOT Clary UPS.JPG|UPS Front View]]<br>[[Media:TRF PQL TS PHOT Clary UPS Contacts.JPG|UPS Contacts]]<br>[[Media:TRF PQL TS PHOT Clary BatteryBackupUPSOnly Bypass Switch.JPG|Bypass Switch]]<br>[[Media:TRF PQL TS PHOT Clary BatteryBackupUPSOnly BypassSwitchLabel.JPG|Bypass Switch Label]]
|-
|-
|
|
|[http://www.editraffic.com/ EDI / Eberle Design Inc.]
|[http://www.clary.com/products/traffic-its/sp-series/sp1250lx#downloads Clary]
|[[media:TRF PQL TS CAT EDI MMU.pdf|MMU2-16-LE(ip)]]
|[[Media:TRF PQL TS CAT Clary BatteryBackupUPS.pdf|Combined Battery and CNG Backup Unit<br>SP 1250-LX-R-48 – Uninterruptible Traffic System with  Integrated PIM and Programmable Display<br>SPO-09A2 – SNMP Adapter with cables manual and software<br>SPD-302C – Bypass Switch<br>100-16136  – 48 VDC Battery Generator Interface Box<br>104-16163-60  – 48 Volt Dual String Battery Cable<br>48-volt system]]
|[[media:TRF PQL TS MEM EDI MMU.pdf|1/10/13]]
|[[Media:TRF PQL TS MEM Clary CombinedBatteryBackupUPS-CNGGenerator SPSeries-PD.pdf|4/12/10]]
|[[media:TRF PQL TS PHOT EDI MMU Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT EDI MMU Back.JPG|Back View]]
|[[Media:TRF PQL TS PHOT Clary UPS.JPG|UPS Front View]]<br>[[Media:TRF PQL TS PHOT Clary UPS Contacts.JPG|UPS Contacts]]<br>[[Media:TRF PQL TS PHOT Clary CombinedBatteryBackupUPS-CNGGenerator BypassSwitch.JPG|Bypass Switch]]<br>[[Media:TRF PQL TS PHOT Clary CombinedBatteryBackupUPS-CNGGenerator GeneratorInterfaceBox.JPG|Generator Interface Box]]
|}
|}
{{PQLNote|Only used in Hybrid traffic signal cabinet in place of the conflict monitor}}
{{PQLNote|Ethernet port capabilities<br>See Battery requirements below.<br>'''Use ONLY the specified batteries as listed for each UPS system as listed in the table below.'''}}
{{PQLReturn}}


==== K1 Control Relay ====
=== Power Transfer Switches ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,387: Line 2,488:
|-
|-
|
|
|[http://www.econolite.com/ Econolite]
|[https://www.clary.com/ Clary Corporation]
|[[media:TRF PQL TS CAT Econolite K1ControlRelay.pdf|Dwg No. 54408 Rev U]]
|Switch: [[Media:TRF PQL TS CAT Clary PowerTransferSwitch.pdf|SPH-302]]<br>Mounting Bracket: [[Media:TRF PQL TS CAT Clary PowerTransferSwitchMountingBracket.pdf|SPH302-RHK]]
|[[media:TRF PQL TS MEM Econolite K1ControlRelay.pdf|4/6/15]]
|[[Media:TRF PQL TS MEM Clary PowerTransferSwitch.pdf|4/2/21]]
|
|[[Media:TRF PQL TS PHOT Clary PowerTransferSwitch Front.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT Clary PowerTransferSwitch PowerConnection.JPG|Cable Connections]]<br>[[Media:TRF PQL TS PHOT Clary PowerTransferSwitch UPS.JPG|UPS Connection View]]<br>[[Media:TRF PQL TS PHOT Clary PowerTransferSwitch Label.JPG|Label]]
|-
|-
|
|[http://www.te.com/en/home.html Tyco Electronics /<br>Potter & Brumfield]
|[[media:TRF PQL TS CAT TycoElectronics K1ControlRelay.pdf|KRPA-14AGP-120]]
|[[media:TRF PQL TS MEM Tycoelectronics K1ControlRelay.pdf|2/10/11]]
|[[media:TRF PQL TS PHOT TycoElectronics K1ControlRelay.jpg|Side View]]
|}
|}
{{PQLNote|Only used with Hybrid Cabinet}}
{{PQLNote|This is used when there is not battery backup / UPS or CNG generator backup power specified}}
{{PQLReturn}}
 
== Batteries ==


== Mounting Brackets ==
=== Batteries for UPS===
=== Radar Detector Mounting Bracket ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,410: Line 2,506:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
| align="center" style="background:#f0f0f0;"|'''Comments'''
|A Division<br>of Olson<br>Aluminum<br>Castings
|-  
|[http://www.skybracket.com/ Sky Bracket]
|[[media:TRF PQL TS CAT SkyBracket RadarDetectorMountingBracket.pdf|Bracket: SS-SBCLL-ACM-XX]]<br>[[media:TRF PQL TS CAT SkyBracket RadarDetectorMountingAdaptor.pdf|Burle Style Adapter Plate: SB-PLT]]
|[[media:TRF PQL TS MEM SkyBracket RadarDetectorMountingBracket.pdf|2/29/16]]
|[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket BracketBack.JPG|Back View]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket End.JPG|Mounting End]]<br>[[media:TRF PQL TS PHOT SkyBracket RadarMountingBracket TubeCrossSection.JPG|Tube Section]]
|-
|
|
|[http://www.wavetronix.com/en Wavetronix]
|[http://www.clary.com/products/traffic-its/outpost-batteries Clary]
|[[media:TRF PQL TS CAT Wavetronixr RadarDetectorMountingBracket.pdf|WX-SS-611]]
|[[Media:TRF PQL TS CAT Clary BatteryforUPSBackup.pdf|OP72C-41 – Batteries (set of six)<br>72-volt system (Stand alone BBS)<br>OP96C-41 – Batteries (set of eight)<br>48-volt system (Combined BBS/CNG)]]
|[[media:TRF PQL TS MEM Wavetronixr RadarDetectorMountingBracket.pdf|4/29/16]]
|[[Media:TRF PQL TS MEM Clary BatteryforUPSBackup.pdf|10/7/11]]
|[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Side.JPG|Side View]]<br>[[media:TRF PQL TS PHOT Wavetronixr RadarDetectorMountingBracket Connection.JPG|Connection Segments]]
|[[Media:TRF PQL TS PHOT Clary BatteryforUPSBackup.JPG|Battery]]<br>[[Media:TRF PQL TS CAT Clary BatteryforUPSBackup Batteries&Cable.JPG|Battery String]]
|Absorbed Glass Mat (AGM)<br>Valve Regulated , Lead Acid (VRLA)
|}
|}
{{PQLNote|<u>For SkyBracket:</u><br>Stainless steel cable and hardware<br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>66” – for mast arm diameters ranging from 2” to 7”<br>90” – for mast arm diameters ranging from 8” to 11”<br>120” – for mast arm diameters ranging from 12” to 15”<br>165” – for mast arm diameters ranging from 16” to 22"<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}


=== Mast Arm Signal Head Bracket ===
=== Batteries for CNG Generator ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,433: Line 2,524:
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Comments'''
|-
|-
|A Division<br>of Olson<br>Aluminum<br>Castings
|
|[http://www.skybracket.com/ Sky Bracket]
|[http://www.alpha.ca/web2/solutions/by-industry/traffic-its Alpha]
|[[media:TRF PQL TS CAT SkyBracket SignalHeadMountingBracket.pdf|SS-SBCLL-18 (1-Section)<br>SS-SBCLL-46 (3-Section)<br>SS-SBCLL-60 (4-Section)]]<br>[[media:TRF PQL TS CAT SkyBracket HAWKMastArmBracket.PDF|SS-SBCLL_HPB-18 (HAWK)]]
|[[Media:TRF PQL TS CAT Alpha BatteryforUPSBackup.pdf|Model 195 GXL]]
|[[media:TRF PQL TS MEM SkyBracket MastArmMountingBracket.pdf|2/29/16]]<br><br>[[media:TRF PQL TS MEM SkyBracket HAWKMastArmBracket.pdf|10/17/18]]
|[[Media:TRF PQL TS MEM Alpha BatteryforUPSBackup.pdf|1/18/12]]
|[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeFront.JPG|Front View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketandTubeSide.JPG|Side View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket BracketBack.JPG|Back View]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket LowerArmTube.JPG|Lower Arm]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket Upper ArmTube.JPG|Upper Arm]]<br>[[media:TRF PQL TS PHOT SkyBracket SignalHeadMountingBracket TubeCrossSection.JPG|Tube Section]]
|
|-
|Gel Top AGM Terminal Battery  (4 Year Full Replacement Warranty)
|}
|}
{{PQLNote|Stainless steel cable and hardware<br>Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:<br>66” – for mast arm diameters ranging from 2” to 7”<br>90” – for mast arm diameters ranging from 8” to 11”<br>120” – for mast arm diameters ranging from 12” to 15”<br>165” – for mast arm diameters ranging from 16” to 22"<br>If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat}}


=== Side Mount Signal Head and Pedestrian Signal Head Bracket ===
== Rebar Support Products ==
 
=== Support Spacers ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,453: Line 2,546:
|-
|-
|
|
|Auto/Eagle
|[https://www.foundationtechnologies.com/products/#shaftspacer-systems Foundation Technologies, Inc]
|UKS-1452X
|<u>Drill Shaft Wheels:</u><br>[[Media:TRF PQL TS CAT FoundationTechnologies DrillShaftWheels.pdf|SS406 - 3" Clearance<br>SS303 - 1 1/2" Clearance]]<br><u>Support Boots:</u><br>[[Media:TRF PQL TS CAT FoundationTechnologies SupportBoots.pdf|BB711]]
|5/5/03
|[[Media:TRF PQL TS MEM FoundationTechnologies RebarSupportSpacers.pdf|1/12/21]]
|
|
|-
|-
|
|
|[http://componentproducts.com/ Component Products, Inc.]
|[https://pieresearch.com/ Pieresearch]
|TSP880-X
|<u>Drill Shaft Wheels:</u><br>[[Media:TRF PQL TS CAT Pieresearch DrillShaftWheels.pdf|6QLHD - 3" Clearance<br>4QLHD - 2" Clearance]]<br>[[Media:TRF PQL TS DWG Pieresearch DrillShaftWheels.pdf|Technical Drawing]]<br><u>Support Boots:</u><br>[[Media:TRF PQL TS CAT Pieresearch SupportBoots.pdf|#5 - #14 Bars: 3PB]]<br>[[Media:TRF PQL TS DWG Pieresearch SupportBoots.pdf|Technical Drawing]]
|5/5/03
|[[Media:TRF PQL TS MEM Pieresearch RebarSupportSpacers.pdf|7/12/19]]
|
|
|-
|-
|
|
|Gades
|[http://www.rebarsupportproducts.com/ Rebar Support Products]
|UKS1452X / PDM-405
|<u>Drill Shaft Wheels:</u><br>[[Media:TRF PQL TS CAT RebarSupportProducts DrillShaftWheels.pdf|DP300 - 3" Clearance<br>DP200 - 2" Clearance]]<br><u>Support Boots:</u><br>[[Media:TRF PQL TS CAT RebarSupportProducts SupportBoots.pdf|#3 - #8 Bars: BB38<br>#8 - #11 Bars: BB811]]
|5/5/03
|[[Media:TRF PQL TS MEM RebarSupportProducts RebarSupportSpacers.pdf|7/12/19]]
|
|
|-
|}
|}
{{PQLNote|Yellow polycarbonate<br>X&#x003D;Y for Yellow<br>X&#x003D; B for Black}}
{{PQLNote|<u>Number of Wheels</u><br>Min number per tier: 4<br>Min spacing from top of shaft: 6'<br>Max spacing from bottom of shaft: 2'<br>Max spacing along shaft: 8'<br><u>Number of Pier Supports</u><br>One per every 1,500 lbs of cage weight<br>Min one on every other vertical bar}}
{{PQLReturn}}


=== Mini Pre-empt Detector Bracket ===
== Secondary Service Pedestals ==
=== Aluminum Electrical Service Enclosure ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,482: Line 2,578:
|-
|-
|
|
|[http://www.pelcoinc.com/Home.aspx Pelco Products, Inc.]
|[http://www.myerspowerproducts.com/ Myers Custom Products, Inc.]
|[[media:TRF PQL TS CAT Pelco EVPDetectorMountingBracket.pdf|Astro Brac AB-0163-L-PNC]]
|[[Media:TRF PQL TS CAT Myers SecondaryServicePedestal.pdf|MEA-IIVLM-TS-R-LB]]
|[[media:TRF PQL TS MEM Pelco EVPDetectorMountingBracket.pdf|12/29/04]]
|[[Media:TRF PQL TS MEM Myers SecondaryServicePedestal.pdf|4/19/19]]
|
|
|-
|Purchased by<br>Myers Custom Products, Inc
|[http://www.pedestals.net/contact_us.php Pacific Utility Products]
|[[Media:TRF PQL TS CAT PacificUtilityProducts SecondaryServicePedestal.pdf|USP2R-100-112C-OPK-TS-AL-LBP]]
|[[Media:TRF PQL TS MEM PacificUtilityProducts SecondaryServicePedestal.pdf|2/17/12]]
|[[Media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal FrontView.JPG|Front View]]<br>[[Media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal InteriorView.JPG|Interior View]]<br>[[Media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal MeterSocket.JPG|Meter Socket]]<br>[[Media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal Lock.JPG|Lock]]<br>[[Media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal Breaker.JPG|Breaker]]<br>[[Media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal BottomView.JPG|Bottom View]]
|}
|}
{{PQLNote|Cable mount<br>L &#x003D; Cable Length (45”, 62” or 84”)<br>PNC &#x003D; Process No Color}}
{{PQLNote|0.125” Aluminum, 30 amp breaker<br>Corbin #2 lock on door<br>No photocell or lighting relays<br>Ringless Meter Socket with Lever By-Pass}}
{{PQLReturn}}
{{PQLReturn}}


== Poles ==
=== Battery Backup / Electrical Service Enclosure ===
=== Aluminum Pedestal Poles ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,500: Line 2,601:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|[http://www.myerspowerproducts.com/ Myers Custom Products, Inc.]
|Cabinet – MET2-PB-M030-AC-EMI<br>Drawing No. F518506
|8/23/05
|
|
|[http://componentproducts.com/ Component Products, Inc]
|[[media:TRF PQL TS CAT ComponentProducts PedestalPoleBase.pdf|Square Pedestal Base: CPI-BAS-1-P]]<br>
[[media:TRF PQL TS CAT ComponentProducts PedestalPoleCap.pdf|Pole Cap: CPI-APC-1]]<br>
[[media:TRF PQL TS CAT ComponentProducts PedestalPoleShaft.pdf|9’ Pedestal Pole: CPI-AP-9-40<br>13’ Pedestal Pole: CPI-AP-13-40<br>14’ Pedestal Pole: CPI-AP-14-40]]<br>
[[media:TRF PQL TS CAT ComponentProducts PedestalPoleCollar.pdf|Base Collar: CPI-RBC-1]]
|[[media:TRF PQL TS MEM ComponentProducts PedestalPole&Base.pdf|4/24/14]]
|[[media:TRF PQL TS PHOT ComponentProducts PedestalPoleBase.jpg|Base]]
|-
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|Pacific Utility Products
|Cabinet – USP29-57-BBS
|7/9/10
|
|
|[http://www.gadestraffic.com/ Gades Sales]
|[[media:TRF PQL TS CAT GadesSales PedestalPoleBase.pdf|Square Pedestal Base: PB-5335-1S-GL-PNC]]<br>
[[media:TRF PQL TS CAT GadesSales PedestalPoleCap.pdf|Pole Cap: PB-5402-PNC]]<br>
[[media:TRF PQL TS CAT GadesSales PedestalPoleShaft.pdf|9’ Pedestal Pole: PB5100-9-PNC<br>13’ Pedestal Pole: PB5100-13-PNC<br>14’ Pedestal Pole: PB5100-14-PNC]]<br>
[[media:TRF PQL TS CAT GadesSales PedestalPoleCollar.pdf|Base Collar: PB-5325-PNC]]
|[[media:TRF PQL TS MEM GadesSales PedestalPole&Base.pdf|4/24/14]]
|[[media:TRF PQL TS PHOT GadesSales PedestrianPoleBase Side.jpg|Side View]]<br>[[media:TRF PQL TS PHOT GadesSales PedestrianPoleBase Bottom.jpg|Bottom View]]<br>[[media:TRF PQL TS PHOT GadesSales PedestrianPoleBase PipeThreads.jpg|Threaded Opening]]<br>[[media:TRF PQL TS PHOT GadesSales PedestrianPoleBase Cover.jpg|Cover]]
|-
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|Traffic Signal Controls
|Cabinet – 2116UPME1401
|9/3/09
|
|
|[http://www.pelcoinc.com/ Pelco Products, Inc.]
|[[media:TRF PQL TS CAT Pelco PedestalPoleBase.pdf|Square Pedestal Base: PB-5335-1S-GL-PNC]]<br>
[[media:TRF PQL TS CAT Pelco PedestalPoleCap.pdf|Pole Cap: PB-5402-PNC]]<br>
[[media:TRF PQL TS CAT Pelco PedestalPoleShaft.pdf|9’ Pedestal Pole: PB-5100-9-PNC<br>13’ Pedestal Pole: PB-5100-13-PNC<br>14’ Pedestal Pole: PB-5100-14-PNC]]<br>
[[media:TRF PQL TS CAT Pelco PedestalPoleCollar.pdf|Base Collar: PB-5325-PNC]]
|[[media:TRF PQL TS MEM Pelco PedestalPole&Base.pdf|4/23/14]]
|[[media:TRF PQL TS PHOT Pelco PedestalPole&Base.jpg|Base]]<br>[[media:TRF PQL TS PHOT Pelco PedestalPoleBase&Collar.JPG|Base & Collar]]
|}
|}
{{PQLNote|See "Anchor Bolts" for part number information<br>Pole tube is schedule 40<br>Include base collar with every pole<br>Set screws required in base collar<br>Include 2 7/8” OD x 7/8” ID galvanized flat washers<br>Include anchor bolts}}
{{PQLNote|0.125” aluminum<br>Manual transfer switch behind police door<br>For use with external portable generator<br>See below for External Generator Receptacle data<br>20Amp breaker for CCTV Camera Disconnect}}


=== Galvanized Steel Signal Poles ===
=== Battery Backup to CNG Electrical Service Enclosure ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,538: Line 2,630:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|[http://www.millerberndmfg.com/ Millerbernd Manufacturing Company]
|[http://www.myerspowerproducts.com/ Myers Custom Products, Inc.]
|1994 AASHTO: [[media:TRF PQL TS CAT Millerbernd MastArmPoles1994.pdf|780B661]]<br>2013 AASHTO: [[media:TRF PQL TS CAT Millerbernd MastArmPoles.pdf| 780B1885 Rev C]]<br>Identification Label:  [[media:TRF PQL TS CAT Millerbernd MastArmPoleLabel.pdf|Single Arm]]  :  [[media:TRF PQL TS CAT Millerbernd MastArmPoleLabel2.pdf|Double Arm]]
|Cabinet – MET2-PB-M030-DC-EMI<br>Drawing No. F518507
|[[media:TRF PQL TS MEM Millerbernd MastArmPoles1994.pdf|8/10/10]]<br>[[media:TRF PQL TS MEM Millerbernd MastArmPoles.pdf|11/10/14]]
|8/23/05
|
|
|-
|-
|
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|[http://www.unionmetal.com/ Union Metal]
|Pacific Utility Products
|1994 AASHTO: [[media:TRF PQL TS CAT UnionMetal GalvanizedSignalMastArmPoles.pdf|50915-B1 Rev 9]]<br>2013 AASHTO: [[media:TRF PQL TS CAT UnionMetal GalvanizedSteelSignalPole.pdf|50915-B19 Rev 5]]
|Cabinet – USP29-57-BBS
|[[media:TRF PQL TS MEM UnionMetal GalvanizedSignalMastArmPoles.pdf|10/27/04]]<br>[[media:TRF PQL TS MEM UnionMetal GalvanizedSignalPole.pdf|8/31/15]]
|7/9/10
|
|
|-
|-
|
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|[http://www.valmont.com/ Valmont]
|Traffic Signal Controls
|1994 AASHTO: [[media:TRF PQL TS CAT 1994AASHTOValmont MastArmPoles.pdf|DB00175 Rev E]]<br>2013 AASHTO: [[media:TRF PQL TS CAT Valmont GalvanizedSteelSignalPole.pdf|DB01086 Rev F]]
|Cabinet-2116UPME1401
|[[media:TRF PQL TS MEM 1994AASHTOValmont MastArmPoles.pdf|1/26/12]]<br>[[media:TRF PQL TS MEM Valmont GalvanizedSignalPole.pdf|7/28/14]]
|9/3/09
|
|
|}
|}
{{PQLNote|See "Anchor Bolts" for part number information<br>Shall meet 2013 AASHTO Criteria unless otherwise specified in the bid plans, documents and details}}
{{PQLNote|0.125” aluminum<br>For use with permanent CNG generator and gas service line<br>20Amp breaker for CCTV Camera Disconnect}}


=== Pedestrian Pushbutton Pole and Foundation ===
=== CNG External Generator Receptacle ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,568: Line 2,660:
|-
|-
|
|
|[http://www.freymfgcorp.com Frey Manufacturing Corp.]
|Hubbell
|<u>Pedestrian Pushbutton Pole with Pole Cap:</u><br>[[media:TRF_PQL_TS_CAT_FreyMfg_PedestrianPushbuttonPole.pdf|CP6ACT4840TCSS / Dwg No. 8.1.0 Rev. 1]]<br><u>Pedestrian Pushbutton Pole Cap:</u><br>[[media:TRF_PQL_TS_CAT_FreyMfg_PedestrianPushbuttonPoleCap.pdf|TCSS Top Cap with Set Screws for 4" Pipe / Dwg No. 8.4.1 Rev. 1]]
|HBL2710SW including HBL2715 flanged receptacle
|[[media:TRF_PQL_TS_MEM_FreyMfg_CrosswalkPedestal.pdf|11/30/17]]
|4/2/12
|[[Media:TRF_PQL_TS_CAT_FreyMfg_PedestrianPoleShortDemo.JPG|Pedestrian Pole]]<br>[[Media:TRF_PQL_TS_CAT_FreyMfg_BreakawayBase.JPG|Breakaway Base]]<br>[[Media:TRF_PQL_TS_CAT_FreyMfg_BreakawayBase2.JPG|Breakaway Base Angle]]<br>[[Media:TRF_PQL_TS_CAT_FreyMfg_PedestalDoor..JPG|Pedestal Door]]<br>[[Media:TRF_PQL_TS_CAT_FreyMfg_PoleCap.JPG|Pole Cap]]<br>[[Media:TRF_PQL_TS_CAT_FreyMfg_Bolts.JPG|Bolts]]
|
|}
|-
{{PQLNote|Frey Mfg pole requires approved Two-Part Epoxy.
|
}}
|Reliance Controls
 
|PK30 Power Inlet Kit, including L1430F flanged receptacle
== Power Backup Systems ==
|4/2/12
=== CNG Generators ===
|
|}
{{PQLNote|Twist Lock Recessed Male, 30 Amp 120/240 Volt, 4 prong including ground with outdoor hinged cover}}
{{PQLReturn}}


== Signal Heads ==
=== Signal Head Louvers ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,588: Line 2,685:
|-
|-
|
|
|[http://www.alpha.ca/web2/index.php Alpha Technologies]
|[http://www.pelcoinc.com/Traffic.aspx Pelco]
|AlphaGen CE-3x2-50-48 NG with Cold Weather Starting Kit<br>With PCC-3x  Polymer Concrete Pre-Cast Pad<br>Includes Alpha supplied battery<br><br><font color="red">'''DO NOT PROVIDE WITH TRANSFORMER  AND FUSE'''</font>
|[[Media:TRF PQL TS CAT Pelco SignalHeadLouvers.pdf|GL-1010-X-UC-P02]]
|6/17/03
|[[Media:TRF PQL TS MEM Pelco SignalHeadLouvers.pdf|11/14/14]]
|
|
|-
|}
|}
{{PQLNote|48V DC output voltage<br>96 amp max DC output current<br>10.5 Hp single OHV engine<br>13.5 VDC Ignition Charger Voltage<br>6 amp max Ignition Charger Current<br>2800 to 3600 RPM variable speed<br>80 CuFt/hr Natural Gas, 1000 BTU/CuFt<br>0.5 – 2 PSI Gas Inlet Pressure}}
{{PQLNote|Geometrically programmed louver with black visor<br>X &#x003D; 7, 8, 9, 11, 12, 15, 23.5 or 42 degrees depending on the cut-off angle desired.<br>The maximum number of louvers comes with the 7 degree cut-off<br>UC  &#x003D; Universal Clips<br>P02  &#x003D; Black}}
{{PQLReturn}}


=== UPS Systems ===
=== Vehicular Signal Heads ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,604: Line 2,704:
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|<font color="red">'''For Maintenance<br>Use Only'''</font>
|Alpha
|Novus FXM-1100 – Part No. 017-230-23 (48-volt system)<br>with Automatic Transfer Switch and AC receptacle  P/N 02016827
|11/10/11
|
|
|-
|[http://www.econolite.com/index.php/products/signals/ Econolite Control Products, Inc.]
|<font color="red">'''For Maintenance<br>Use Only'''</font>
|[[Media:TRF PQL TS CAT Econolite VehiclularSignalHead.pdf|<u>Yellow Body:</u><br>TP11VJC2P0H0 for 1 Section<br>TP31VJC2P0H0 for 3 Section<br>TP41VJC2P0H0 for 4 Section<br><br><u>Black Body:</u><br>TP11VJF2P0H0 for 1 Section<br>TP31VJF2P0H0 for 3 Section<br>TP41VJF2P0H0 for 4 Section]]
|[http://www.blueeartheps.com/ Blue Earth Energy Power Solutions]
|[[Media:TRF PQL TS MEM Econolite VehiclularSignalHead.pdf|5/9/03]]
|[[media:TRF PQL TS CAT BlueEarth PowerBackupUPS.pdf|170 UPStealth<br>1000 Watt Capacity: Inverter-170-01<br>1500 Watt Capacity: Inverter-170-01-HD]]<br>[[media:TRF PQL TS CAT BlueEarth PowerInterfaceModule.pdf|Power Interface Module: NKKS732]]
|[[Media:TRF PQL TS PHOT Econolite VehiclularSignalHead FrontView.jpg|Front View]]<br>[[Media:TRF PQL TS PHOT Econolite VehiclularSignalHead Back.JPG|Back View]]<br>[[Media:TRF PQL TS PHOT Econolite VehiclularSignalHead Body.JPG|Open Front View]]<br>[[Media:TRF PQL TS PHOT Econolite VehiclularSignalHead WiringTerminals.JPG|Wiring Terminals]]<br>[[Media:TRF PQL TS PHOT Econolite VehiclularSignalHead Latch.jpg|Latch]]
|[[media:TRF PQL TS MEM BlueEarth PowerBackupUPS.pdf|2/10/15]]
|[[media:TRF PQL TS PHOT BlueEarth PowerBackupUPSInverter Front.JPG|Inverter Front View]]<br>[[media:TRF PQL TS PHOT BlueEarth PowerBackupUPSInverter Back.JPG|Inverter Back View]]<br>[[media:TRF PQL TS PHOT BlueEarth PowerInterfaceModule Front.JPG|Power Interface Module]]<br>[[media:TRF PQL TS PHOT BlueEarth Cables.JPG|Cables]]
|-  
|-  
|
|
|[http://www.clary.com/products/traffic-its/sp-series/sp1250lx#downloads Clary]
|[http://www.mccain-inc.com/traffic.html McCain Traffic Supply]
|[[media:TRF PQL TS CAT Clary BatteryBackupUPS.pdf|Stand Alone Battery  Backup /UPS Unit<br>SP 1250-LX-R – Uninterruptible Traffic System with  Integrated PIM and Programmable Display<br>SPO-09A2 – SNMP Adapter with cables manual and software<br>SPD-302C – Bypass Switch with GFCI and Generator Plug<br>SP-19N1 – Battery Cable<br>72-volt system]]
|[[Media:TRF PQL TS CAT McCain VehiclularSignalHead.pdf|<u>Yellow Body:</u><br>M22167-P for 1 Section<br>M22436-P for 3 Section<br>M31084-P for 4 Section<br><br><u>Black Body:</u><br>M22168-P for 1 Section<br>M22435-P for 3 Section<br>M30883-P for 4 Section]]<br><br>[[Media:TRF PQL TS CAT McCain VehicularSignalVisor.pdf|M19271 Black Poly Visors]]
|[[media:TRF PQL TS MEM Clary BatteryBackupUPS.pdf|9/26/13]]
|[[Media:TRF PQL TS CAT McCain VehicularSignalVisor.pdf|5/14/13]]
|[[media:TRF PQL TS PHOT Clary UPS.JPG|UPS Front View]]<br>[[media:TRF PQL TS PHOT Clary UPS Contacts.JPG|UPS Contacts]]<br>[[media:TRF PQL TS PHOT Clary BatteryBackupUPSOnly Bypass Switch.JPG|Bypass Switch]]<br>[[media:TRF PQL TS PHOT Clary BatteryBackupUPSOnly BypassSwitchLabel.JPG|Bypass Switch Label]]
|[[Media:TRF PQL TS PHOT McCain VehiclularSignalHead Body.JPG|Open Front View]]<br>[[Media:TRF PQL TS PHOT McCain VehiclularSignalHead WiringTerminal.JPG|Wiring Terminal]]<br>[[Media:TRF PQL TS PHOT McCain VehiclularSignalHead SideView.JPG|Side View]]<br>[[Media:TRF PQL TS PHOT McCain VehiclularSignalHead Latch.JPG|Latch]]<br>[[Media:TRF PQL TS PHOT McCain VehiclularSignalHead Label.JPG|Label]]
|-
|-
|
|
|[http://www.clary.com/products/traffic-its/sp-series/sp1250lx#downloads Clary]
|[http://www.mobotrexmanufacturing.com/products/ Mobotrex / Eagle Signal]
|[[media:TRF PQL TS CAT Clary BatteryBackupUPS.pdf|Combined Battery and CNG Backup Unit<br>SP 1250-LX-R-48 – Uninterruptible Traffic System with  Integrated PIM and Programmable Display<br>SPO-09A2 – SNMP Adapter with cables manual and software<br>SPD-302C – Bypass Switch<br>100-16136  – 48 VDC Battery Generator Interface Box<br>104-16163-60  – 48 Volt Dual String Battery Cable<br>48-volt system]]
|[[media:TRF PQL TS BRO Mobotrex-Eagle VehicularSignalHead.pdf|Brochure]]<br><u>Yellow Body</u><br>[[media:TRF PQL TS CAT Mobotrex-Eagle 1SectVehicularSignalHead.pdf|SA101A1C11YBB10-37 for 1 Section]]<br>[[Media:TRF PQL TS CAT Mobotrex-Eagle 3SectVehicularSignalHead.pdf|SA103A1C11YBB30-37 for 3 Section]]<br>[[media:TRF PQL TS CAT Mobotrex-Eagle 4SectVehicularSignalHead.pdf|SA104A1C11YBB40-37 for 4 Section]]<br>SA1031T3T1111YBB - HAWK<br><br><u>Black Body</u>:<br>[[media:TRF PQL TS CAT Mobotrex-Eagle 1SectVehicularSignalHead.pdf|SA101A1C11BBB10-22 for 1 Section]]<br>[[Media:TRF PQL TS CAT Mobotrex-Eagle 3SectVehicularSignalHead.pdf|SA103A1C11BBB30-37 for 3 Section]]<br>[[media:TRF PQL TS CAT Mobotrex-Eagle 4SectVehicularSignalHead.pdf|SA104A1C11BBB30-37 for 4 Section]]<br>SA1031T3T1111BBB - HAWK
|[[media:TRF PQL TS MEM Clary CombinedBatteryBackupUPS-CNGGenerator SPSeries-PD.pdf|4/12/10]]
|[[Media:TRF PQL TS MEM Mobotrex-Eagle VehicularSignalHead.pdf|5/5/03]]
|[[media:TRF PQL TS PHOT Clary UPS.JPG|UPS Front View]]<br>[[media:TRF PQL TS PHOT Clary UPS Contacts.JPG|UPS Contacts]]<br>[[media:TRF PQL TS PHOT Clary CombinedBatteryBackupUPS-CNGGenerator BypassSwitch.JPG|Bypass Switch]]<br>[[media:TRF PQL TS PHOT Clary CombinedBatteryBackupUPS-CNGGenerator GeneratorInterfaceBox.JPG|Generator Interface Box]]
|}
{{PQLNote|Ethernet port capabilities<br>See Battery requirements below.<br>'''Use ONLY the specified batteries as listed for each UPS system as listed in the table below.'''}}
{{PQLReturn}}
 
=== Power Transfer Switches ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|Formerly Gen-Tran Corporation
|[http://www.generac.com/ Generac]
|[[media:TRF PQL TS CAT Generac TransferSwitch.pdf|6377]]
|[[media:TRF PQL TS MEM Generac TransferSwitch.pdf|10/5/05]]
|[[media:TRF PQL TS PHOT Generac TransferSwitch Front.JPG|Front View]]<br>[[media:TRF PQL TS PHOT Generac TransferSwitch Bottom.JPG|Bottom View]]
|-
|
|
|[http://www.reliancecontrols.com/ Reliance Controls]
|[[media:TRF PQL TS CAT RelianceControls ManualTransferSwitch.pdf|C30A2L]]
|[[media:TRF PQL TS MEM RelianceControls ManualTransferSwitch.pdf|7/19/16]]
|
|}
{{PQLNote|Double Pole 30 Amp manual transfer switch<br>NEMA 3R Aluminum housing with No. 2 keyed lock<br>Pilot light indicator<br>4-prong L14-30R Generator Outlet}}
== Batteries ==
=== Batteries for UPS===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Comments'''
|-
|<font color="red">'''For Maintenance<br>Use Only'''</font>
|[http://www.alpha.ca/web2/solutions/by-industry/traffic-its Alpha]
|[[media:TRF PQL TS CAT Alpha BatteryforUPSBackup.pdf|Model 165 GXL – Part No. 1810015 (set of four batteries)<br>48-volt system (Stand alone or combined BBS/CNG)]]
|[[media:TRF PQL TS MEM Alpha BatteryforUPSBackup.pdf|1/18/12]]
|
|Gel Top Terminal Battery  (4 Year Full Replacement Warranty)
|-
|<font color="red">'''For Maintenance<br>Use Only'''</font>
|[http://www.blueeartheps.com/ Blue Earth Energy Power Solutions]
|[[media:TRF PQL TS CAT BlueEarth UPSBattery.pdf|Living-Hinge Battery Panel<br>300 Watt: Battery-300-01<br>500 Watt: Battery-500-01<br>500 Watt Shelf Mount: Battery-500-N-01]]<br>[[media:TRF PQL TS CAT BlueEarth WallChargingAdapter.pdf|Wall Charging Adapter]]
|[[media:TRF PQL TS MEM BlueEarth PowerBackupUPSBatteries.pdf|2/10/15]]
|[[media:TRF PQL TS PHOT BlueEarth UPSBattery.JPG|Battery Front]]<br>[[media:TRF PQL TS PHOT BlueEarth UPSBattery IndicatorLight.JPG|Indicator Light]]
|Fits between rack and outside cabinet wall, except for shelf mount unit
|-
|
|[http://www.clary.com/products/traffic-its/outpost-batteries Clary]
|[[media:TRF PQL TS CAT Clary BatteryforUPSBackup.pdf|OP72C-41 – Batteries (set of six)<br>72-volt system (Stand alone BBS)<br>OP96C-41 – Batteries (set of eight)<br>48-volt system (Combined BBS/CNG)]]
|[[media:TRF PQL TS MEM Clary BatteryforUPSBackup.pdf|10/7/11]]
|[[media:TRF PQL TS PHOT Clary BatteryforUPSBackup.JPG|Battery]]<br>[[media:TRF PQL TS CAT Clary BatteryforUPSBackup Batteries&Cable.JPG|Battery String]]
|Absorbed Glass Mat (AGM)<br>Valve Regulated , Lead Acid (VRLA)
|}
=== Batteries for CNG Generator ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
| align="center" style="background:#f0f0f0;"|'''Comments'''
|-
|
|[http://www.alpha.ca/web2/solutions/by-industry/traffic-its Alpha]
|[[media:TRF PQL TS CAT Alpha BatteryforUPSBackup.pdf|Model 195 GXL]]
|[[media:TRF PQL TS MEM Alpha BatteryforUPSBackup.pdf|1/18/12]]
|
|Gel Top AGM Terminal Battery  (4 Year Full Replacement Warranty)
|}
== Secondary Service Pedestals ==
=== Aluminum Electrical Service Enclosure ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|
|[http://www.myerspowerproducts.com/ Myers Custom Products, Inc.]
|<font color="red">'''MEA-IIVLM-TSR – new part number –<br>drawings have been approved but<br>physical review of product is pending'''</font>
|
|
|-
|Purchased by<br>Myers Custom Products, Inc
|[http://www.pedestals.net/contact_us.php Pacific Utility Products]
|[[media:TRF PQL TS CAT PacificUtilityProducts SecondaryServicePedestal.pdf|USP2R-100-112C-OPK-TS]]
|[[media:TRF PQL TS MEM PacificUtilityProducts SecondaryServicePedestal.pdf|2/17/12]]
|[[media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal FrontView.JPG|Front View]]<br>[[media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal InteriorView.JPG|Interior View]]<br>[[media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal MeterSocket.JPG|Meter Socket]]<br>[[media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal Lock.JPG|Lock]]<br>[[media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal Breaker.JPG|Breaker]]<br>[[media:TRF PQL TS PHOT PacificUtilityProducts SecondaryServicePedestal BottomView.JPG|Bottom View]]
|}
{{PQLNote|0.125” Aluminum, 30 amp breaker<br>Corbin #2 lock on door<br>No photocell or lighting relays<br>Ringless Meter Socket with Horn By-Pass}}
{{PQLReturn}}
=== Battery Backup / Electrical Service Enclosure ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|[http://www.myerspowerproducts.com/ Myers Custom Products, Inc.]
|Cabinet – MET2-PB-M030-AC-EMI<br>Drawing No. F518506
|8/23/05
|
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|Pacific Utility Products
|Cabinet – USP29-57-BBS
|7/9/10
|
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|Traffic Signal Controls
|Cabinet – 2116UPME1401
|9/3/09
|
|}
{{PQLNote|0.125” aluminum<br>Manual transfer switch behind police door<br>For use with external portable generator<br>See below for External Generator Receptacle data<br>20Amp breaker for CCTV Camera Disconnect}}
=== Battery Backup to CNG Electrical Service Enclosure ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|[http://www.myerspowerproducts.com/ Myers Custom Products, Inc.]
|Cabinet – MET2-PB-M030-DC-EMI<br>Drawing No. F518507
|8/23/05
|
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|Pacific Utility Products
|Cabinet – USP29-57-BBS
|7/9/10
|
|-
|<font color="red">'''USED ONLY FOR MAINTENANCE REPLACEMENTS'''</font>
|Traffic Signal Controls
|Cabinet-2116UPME1401
|9/3/09
|
|}
{{PQLNote|0.125” aluminum<br>For use with permanent CNG generator and gas service line<br>20Amp breaker for CCTV Camera Disconnect}}
=== CNG External Generator Receptacle ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|
|Hubbell
|[http://www.northamericansignal.com/ North American Signal]
|HBL2710SW including HBL2715 flanged receptacle
|[[Media:TRF PQL TS CAT NorthAmerican VehicleSignal.pdf|<u>Yellow Body:</u><br>PT100YB-OTB-MAS for 1-Section<br>PT300YB-OTB-MAS for 3-Section<br>PT400YB-0TB-MAS for 4-Section<br><br><u>Black Body</u><br>PT100BB-0TB-MAS for 1-Section<br>PT300BB-0TB-MAS for 3-Section<br>PT400BB-0TB-MAS for 4-Section]]
|4/2/12
|[[Media:TRF PQL TS MEM NorthAmerican VehicleSignal.pdf|11/15/19]]
|
|[[Media:TRF PQL TS PHOT NorthAmerican VehicleSignal Front.JPG|Front]]<br>[[Media:TRF PQL TS PHOT NorthAmerican VehicleSignal Back.JPG|Back]]<br>[[Media:TRF PQL TS PHOT NorthAmerican VehicleSignal Hinge.JPG|Hinge]]<br>[[Media:TRF PQL TS PHOT NorthAmerican VehicleSignal Side.JPG|Side]]<br>[[Media:TRF PQL TS PHOT NorthAmerican VehicleSignal Terminals.JPG|Terminal]]<br>[[Media:TRF PQL TS PHOT NorthAmerican VehicleSignal ThumbScrew.JPG|Thumb Screw]]<br>[[Media:TRF PQL TS PHOT NorthAmerican VehicleSignal Label.JPG|Label]]
|-
|-
|
|
|Reliance Controls
|[https://www.peektraffic.com/index.php Peek Traffic]
|PK30 Power Inlet Kit, including L1430F flanged receptacle
|<u>Yellow Body</u><br>[[Media:TRF PQL TS CAT Peek VehicularSignalHead.pdf|PSS81S001FO for 1 Section<br>PSS83S003FO for 3 Section<br>PSS84S004FO for 4 Section]]<br><br><u>Black Body</u><br>[[Media:TRF PQL TS CAT Peek VehicularSignalHead.pdf|PSS81E001FO for 1 Section<br>PSS83E003FO for 3 Section<br>PSS84E004FO for 4 Section]]
|4/2/12
|[[Media:TRF PQL TS MEM Peek VehicularSignalHead.pdf|5/5/03]]
|
|
|}
|}
{{PQLNote|Twist Lock Recessed Male, 30 Amp 120/240 Volt, 4 prong including ground with outdoor hinged cover}}
{{PQLNote|Yellow Polycarbonate Body (Standard)<br>Black Polycarbonate Body (Special)<br>Black Polycarbonate Doors and Visors<br>Visors to be Tunnel Type<br>LED retrofit<br>12” Sections}}
{{PQLReturn}}


== Signal Heads ==
=== Countdown Pedestrian Signal Heads ===
=== Signal Head Louvers ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
|+
Line 2,824: Line 2,746:
|-
|-
|
|
|[http://www.pelcoinc.com/Traffic.aspx Pelco]
|[http://www.mccain-inc.com/ McCain Traffic Supply]
|[[media:TRF PQL TS CAT Pelco SignalHeadLouvers.pdf|GL-1010-X-UC-P02]]
|[[Media:TRF PQL TS CAT McCain PedestrianSignal.pdf|M31466 – Yellow housing<br>M31655 – Black housing]]
|[[media:TRF PQL TS MEM Pelco SignalHeadLouvers.pdf|11/14/14]]
|[[Media:TRF PQL TS MEM McCain PedestrianSignal.pdf|12/30/04]]
|
|-
 
|}
{{PQLNote|Geometrically programmed louver with black visor<br>X &#x003D; 7, 8, 9, 11, 12, 15, 23.5 or 42 degrees depending on the cut-off angle desired.<br>The maximum number of louvers comes with the 7 degree cut-off<br>UC  &#x003D; Universal Clips<br>P02  &#x003D; Black}}
{{PQLReturn}}
 
=== Vehicular Signal Heads ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|
|[http://www.mobotrexmanufacturing.com/products/ Mobotrex / Eagle Signal]
|<u>Yellow Body</u><br>[[media:TRF PQL TS CAT Mobotrex-Eagle VehicularSignalHead.pdf|SA103A1111YBB for 3 Section<br>SA104A1111YBB for 4 Section<br>SA101A1111YBB for 1 Section<br>SA1031T3T1111YBB - HAWK<br><br><u>Black Body</u>:<br>SA103A1111BBB for 3 Section<br>SA104A1111BBB for 4 Section<br>SA101A1111BBB for 1 Section<br>SA1031T3T1111BBB - HAWK]]
|[[media:TRF PQL TS MEM Mobotrex-Eagle VehicularSignalHead.pdf|5/5/03]]
|
|-
|
|[http://www.econolite.com/index.php/products/signals/ Econolite Control Products, Inc.]
|[[media:TRF PQL TS CAT Econolite VehiclularSignalHead.pdf|<u>Yellow Body:</u><br>TP31VJC2P0H0 for 3 Section<br>TP41VJC2P0H0 for 4 Section <br>TP11VJC2P0H0 for 1 Section<br><br><u>Black Body:</u><br>TP31VJF2P0H0 for 3 Section<br>TP41VJF2P0H0 for 4 Section<br>TP11VJF2P0H0 for 1 Section]]
|[[media:TRF PQL TS MEM Econolite VehiclularSignalHead.pdf|5/9/03]]
|[[media:TRF PQL TS PHOT Econolite VehiclularSignalHead FrontView.jpg|Front View]]<br>[[media:TRF PQL TS PHOT Econolite VehiclularSignalHead Back.JPG|Back View]]<br>[[media:TRF PQL TS PHOT Econolite VehiclularSignalHead Body.JPG|Open Front View]]<br>[[media:TRF PQL TS PHOT Econolite VehiclularSignalHead WiringTerminals.JPG|Wiring Terminals]]<br>[[media:TRF PQL TS PHOT Econolite VehiclularSignalHead Latch.jpg|Latch]]
|-
|
|
|[http://www.mccain-inc.com/traffic.html McCain Traffic Supply]
|[[media:TRF PQL TS CAT McCain VehiclularSignalHead.pdf|<u>Yellow Body:</u><br>M22167-Pfor 1 Section<br>M22436-P for 3 Section<br>M31084-P for 4 Section<br><br><u>Black Body:</u><br>M22168-P for 1 Section<br>M22435-P for 3 Section<br>M30883-P for 4 Section]]<br><br>[[media:TRF PQL TS CAT McCain VehicularSignalVisor.pdf|M19271 Black Poly Visors]]
|[[media:TRF PQL TS CAT McCain VehicularSignalVisor.pdf|5/14/13]]
|[[media:TRF PQL TS PHOT McCain VehiclularSignalHead Body.JPG|Open Front View]]<br>[[media:TRF PQL TS PHOT McCain VehiclularSignalHead WiringTerminal.JPG|Wiring Terminal]]<br>[[media:TRF PQL TS PHOT McCain VehiclularSignalHead SideView.JPG|Side View]]<br>[[media:TRF PQL TS PHOT McCain VehiclularSignalHead Latch.JPG|Latch]]<br>[[media:TRF PQL TS PHOT McCain VehiclularSignalHead Label.JPG|Label]]
|-
|-
|
|
|[https://www.peektraffic.com/index.php Peek Traffic]
|[http://www.northamericansignal.com/ North American Signal]
|<u>Yellow Body</u><br>[[media:TRF PQL TS CAT Peek VehicularSignalHead.pdf|PSS81S001FO for 1 Section<br>PSS83S003FO for 3 Section<br>PSS84S004FO for 4 Section]]<br><br><u>Black Body</u><br>[[media:TRF PQL TS CAT Peek VehicularSignalHead.pdf|PSS81E001FO for 1 Section<br>PSS83E003FO for 3 Section<br>PSS84E004FO for 4 Section]]
|[[Media:TRF PQL TS CAT NorthAmerican VehicleSignal.pdf|PPYBP0_B1-MAS - Yellow housing<br>PPBBP0_B1-MAS - Black housing]]
|[[media:TRF PQL TS MEM Peek VehicularSignalHead.pdf|5/5/03]]
|[[Media:TRF PQL TS MEM NorthAmerican VehicleSignal.pdf|11/15/19]]
|
|[[Media:TRF PQL TS PHOT NorthAmerican PedSignal Front.JPG|Front]]<br>[[Media:TRF PQL TS PHOT NorthAmerican PedSignal Bottom.JPG|Bottom]]<br>[[Media:TRF PQL TS PHOT NorthAmerican PedSignal Gasket.JPG|Gasket]]<br>[[Media:TRF PQL TS PHOT NorthAmerican PedSignal Hinge.JPG|Hinge]]<br>[[Media:TRF PQL TS PHOT NorthAmerican PedSignal Terminal.JPG|Terminal]]<br>[[Media:TRF PQL TS PHOT NorthAmerican PedSignal Label.JPG|Label]]
|}
{{PQLNote|Yellow Polycarbonate Body (Standard)<br>Black Polycarbonate Body (Special)<br>Black Polycarbonate Doors and Visors<br>Visors to be Tunnel Type<br>LED retrofit<br>12” Sections}}
 
=== Countdown Pedestrian Signal Heads ===
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+
| align="center" style="background:#f0f0f0;"|'''Notes'''
| align="center" style="background:#f0f0f0;"|'''Manufacturer'''
| align="center" style="background:#f0f0f0;"|'''Catalog Number'''
| align="center" style="background:#f0f0f0;"|'''Approval Date'''
| align="center" style="background:#f0f0f0;"|'''Photos'''
|-
|-
|
|
|[http://www.mccain-inc.com/ McCain Traffic Supply]
|[https://www.mobotrex.com/?utm_source=mobotrexmanufacturing Mobotrex / EagleSignal]
|[[media:TRF PQL TS CAT McCain PedestrianSignal.pdf|M31466 – Yellow housing<br>M31655 – Black housing]]
|[[Media:TRF PQL TS DWG Mobotrex PedestrianHead.pdf|Drawing]]<br>[[Media:TRF PQL TS CAT Mobotrex PedestrianHead.pdf|SG7-S-Z10C0YB010-00 – Yellow housing<br>SG7-S-Z10C0BB010-00 – Black housing]]
|[[media:TRF PQL TS MEM McCain PedestrianSignal.pdf|12/30/04]]
|[[Media:TRF PQL TS MEM Mobotrex PedestrianHead.pdf|9/20/11]]
|
|[[Media:TRF PQL TS MEM Siemens PedestrianHead.pdf|Top View]]<br>[[Media:TRF PQL TS PHOT Siemens PedestrianHead Inside.JPG|Inside View]]<br>[[Media:TRF PQL TS PHOT Siemens PedestrianHead Latch.JPG|Latch]]
|-
|
|[https://www.siemens.com/us/en/home.html Siemens]
|[[media:TRF PQL TS CAT Siemens PedestrianHead.pdf|SG7-S-Z10COYBB010 – Yellow housing<br>SG7-S-Z10COBBB010 – Black housing]]
|[[media:TRF PQL TS MEM Siemens PedestrianHead.pdf|9/20/11]]
|[[media:TRF PQL TS MEM Siemens PedestrianHead.pdf|Top View]]<br>[[media:TRF PQL TS PHOT Siemens PedestrianHead Inside.JPG|Inside View]]<br>[[media:TRF PQL TS PHOT Siemens PedestrianHead Latch.JPG|Latch]]
|}
|}
{{PQLNote|Yellow polycarbonate body (Standard)<br>Black polycarbonate body (Special)<br>Black Aluminum Door / No Z-Crate Visor<br>Port hole mount}}
{{PQLNote|Yellow polycarbonate body (Standard)<br>Black polycarbonate body (Special)<br>Black Door / No Z-Crate Visor<br>Port hole mount}}
{{PQLReturn}}
{{PQLReturn}}


Line 2,905: Line 2,778:
|
|
|[http://www.kinginnovation.com/index.php King Innovation/Dryconn]
|[http://www.kinginnovation.com/index.php King Innovation/Dryconn]
|<u>For 2 #14 AWG</u><br>[[media:TRF PQL TS CAT KingInnovation LoopLeadConnector Aqua-Orange.pdf|Aqua/Orange Waterproof Connector<br>62110 - Card of 6<br>62125 - Bag of 25<br>62135 - Bag of 100<br>62150 - Bag of 500]]<br><u>For 2, 3, 4 or 5 #14 AWG</u><br>[[media:TRF PQL TS CAT KingInnovation LoopLeadConnector Aqua-Red.pdf|Auqua/Red Waterproof Connector<br>62210 - Card of 5<br>62225 - Bag of 20<br>62235 - Bag of 100<br>62250 - Box of 500]]<br><u>For 4, 5 or 6 #14 AWG</u><br>[[media:TRF PQL TS CAT KingInnovation LoopLeadConnector Aqua-Blue.pdf|Aqua/Blue Waterproof Connector<br>62310 – Card of 3<br>62325 – Bag of 15<br>62335 – Bag of 50<br>62340 – Bag of 250]]
|<u>For 2 #14 AWG</u><br>[[Media:TRF PQL TS CAT KingInnovation LoopLeadConnector Aqua-Orange.pdf|Aqua/Orange Waterproof Connector<br>62110 - Card of 6<br>62125 - Bag of 25<br>62135 - Bag of 100<br>62150 - Bag of 500]]<br><u>For 2, 3, 4 or 5 #14 AWG</u><br>[[Media:TRF PQL TS CAT KingInnovation LoopLeadConnector Aqua-Red.pdf|Auqua/Red Waterproof Connector<br>62210 - Card of 5<br>62225 - Bag of 20<br>62235 - Bag of 100<br>62250 - Box of 500]]<br><u>For 4, 5 or 6 #14 AWG</u><br>[[Media:TRF PQL TS CAT KingInnovation LoopLeadConnector Aqua-Blue.pdf|Aqua/Blue Waterproof Connector<br>62310 – Card of 3<br>62325 – Bag of 15<br>62335 – Bag of 50<br>62340 – Bag of 250]]
|[[media:TRF PQL TS MEM KingInnovation LoopLeadConnector.pdf|10/14/03]]
|[[Media:TRF PQL TS MEM KingInnovation LoopLeadConnector.pdf|10/14/03]]
|[[media:TRF PQL TS PHOT KingInnovation LoopLeadConnector Aqua-Blue.jpg|Aqua/Blue]]
|[[Media:TRF PQL TS PHOT KingInnovation LoopLeadConnector Aqua-Blue.jpg|Aqua/Blue]]
|}
|}
{{PQLNote|Wire Range: Min. #14 AWG / Max. #6 AWG Copper<br>Silicone Sealant Filled<br>Watertight/raintight}}
{{PQLNote|Wire Range: Min. #14 AWG / Max. #6 AWG Copper<br>Silicone Sealant Filled<br>Watertight/raintight}}
Line 2,922: Line 2,795:
|
|
|[http://www.kinginnovation.com/index.php King Innovation/Dryconn]
|[http://www.kinginnovation.com/index.php King Innovation/Dryconn]
|<u>For 2, 3, 4 or 5 #14 AWG</u><br>[[media:TRF PQL TS CAT KingInnovation SignalCableConnector Yellow.pdf|King 4 Yellow: 10444 - Bag of 10]]<br><u>For 2, 3, 4 or 5 #4 AWG</u><br>[[media:TRF PQL TS CAT KingInnovation SignalCableConnector Red.pdf|King 5 Red: 10555 - Bag of 10]]<br><u>For 2, 3, 4 or 5 #14 AWG</u><br>[[media:TRF PQL TS CAT KingInnovation SignalCableConnector Blue.pdf|King 6 Blue: 10670 - Box of 100]]<br><u>For 4, 5 or 6 #14</u><br>[[media:TRF PQL TS CAT KingInnovation SignalCableConnector DarkBlue.pdf|King 9 Dark Blue: 10975 - Box of 75]]
|<u>For 2, 3, 4 or 5 #14 AWG</u><br>[[Media:TRF PQL TS CAT KingInnovation SignalCableConnector Yellow.pdf|King 4 Yellow: 10444 - Bag of 10]]<br><u>For 2, 3, 4 or 5 #14 AWG</u><br>[[Media:TRF PQL TS CAT KingInnovation SignalCableConnector Red.pdf|King 5 Red: 10555 - Bag of 10]]<br><u>For 2, 3, 4 or 5 #14 AWG</u><br>[[Media:TRF PQL TS CAT KingInnovation SignalCableConnector Blue.pdf|King 6 Blue: 10670 - Box of 100]]<br><u>For 4, 5 or 6 #14</u><br>[[Media:TRF PQL TS CAT KingInnovation SignalCableConnector DarkBlue.pdf|King 9 Dark Blue: 10975 - Box of 75]]
|[[media:TRF PQL TS MEM KingInnovation SignalCableConnector.pdf|10/14/03]]
|[[Media:TRF PQL TS MEM KingInnovation SignalCableConnector.pdf|10/14/03]]
|[[media:TRF PQL TS PHOT KingInnovation SignalCableConnector Blue.jpg|King 6 Blue]]
|[[Media:TRF PQL TS PHOT KingInnovation SignalCableConnector Blue.jpg|King 6 Blue]]
|}
|}
{{PQLNote|Wire Range: Min. #22 AWG / Max. #8 AWG  Copper<br>Silicone Sealant Filled<br>Direct Burial}}
{{PQLNote|Wire Range: Min. #22 AWG / Max. #8 AWG  Copper<br>Silicone Sealant Filled<br>Direct Burial}}
Line 2,939: Line 2,812:
|
|
|[http://solutions.3m.com/wps/portal/3M/en_US/NA_Communication_Technologies/Home/Products/~?N=7569738&rt=r3&Nao=15 3M]
|[http://solutions.3m.com/wps/portal/3M/en_US/NA_Communication_Technologies/Home/Products/~?N=7569738&rt=r3&Nao=15 3M]
|Scotchlok Butt Connector:<br>[[media:TRF PQL TS CAT 3M RadarCableConnector.pdf|UAL(BX) 100/box, 10 boxes/case]]
|Scotchlok Butt Connector:<br>[[Media:TRF PQL TS CAT 3M RadarCableConnector.pdf|UAL(BX) 100/box, 10 boxes/case]]
|[[media:TRF PQL TS MEM 3M RadarCableConnector.pdf|6/14/17]]
|[[Media:TRF PQL TS MEM 3M RadarCableConnector.pdf|6/14/17]]
|[[media:TRF PQL TS PHOT 3M RadarCableConnector Top.JPG|Top View]]<br>[[media:TRF PQL TS PHOT 3M RadarCableConnector Side.JPG|Side View]]
|[[Media:TRF PQL TS PHOT 3M RadarCableConnector Top.JPG|Top View]]<br>[[Media:TRF PQL TS PHOT 3M RadarCableConnector Side.JPG|Side View]]
|}
|}
{{PQLNote|Wire Range: Min. #24 AWG / #19 AWG Max. Copper}}
{{PQLNote|Wire Range: Min. #24 AWG / #19 AWG Max. Copper}}
Line 2,957: Line 2,830:
|
|
|[http://www.hilti.com/ HILTI]
|[http://www.hilti.com/ HILTI]
|[[media:TRF_PQL_TS_CAT_Hilti_HIT-RE 500-V3.pdf|HIT-RE 500-V3]]
|[[Media:TRF PQL TS CAT Hilti HIT-RE 500-V3.pdf|HIT-RE 500-V3]]
|[[media:TRF_PQL_TS_MEM_Hilti_HIT-RE 500-V3.pdf|12/4/2017]]
|[[Media:TRF PQL TS MEM Hilti HIT-RE 500-V3.pdf|12/4/2017]]
|
|
|-
|-
|
|
|[http://www.itwredhead.com/ ITW Commercial Construction]
|[http://www.itwredhead.com/ ITW Commercial Construction]
|[[media:TRF_PQL_TS_CAT_Red Head_Epcon A7+.pdf|Red Head Concrete Anchoring Solutions - A7+]]
|[[Media:TRF PQL TS CAT Red Head Epcon A7+.pdf|Red Head Concrete Anchoring Solutions - A7+]]
|[[media:TRF_PQL_TS_MEM_Red Head_A7+ PDF.pdf|12/4/2017]]
|[[Media:TRF PQL TS MEM Red Head A7+ PDF.pdf|12/4/2017]]
|
|
|-
|-
|
|
|[http://www.powers.com/index.php Powers]
|[http://www.powers.com/index.php Powers]
|[[media:TRF_PQL_TS_CAT_Powers _PE1000+.pdf|PE1000+]]
|[[Media:TRF PQL TS CAT Powers PE1000+.pdf|PE1000+]]
|[[media:TRF_PQL_TS_MEM_Powers _PE1000+.pdf|12/4/2017]]
|[[Media:TRF PQL TS MEM Powers PE1000+.pdf|12/4/2017]]
|
|
|-
|-
|
|
|[http://www.strongtie.com/ Simpson Strong-Tie]
|[http://www.strongtie.com/ Simpson Strong-Tie]
|[[media:TRF_PQL_TS_CAT_Simpson Strong-Tie_Set-XP.pdf|SET-XP]]
|[[Media:TRF PQL TS CAT Simpson Strong-Tie Set-XP.pdf|SET-XP]]
|[[media:TRF_PQL_TS_MEM_Simpson Strong-Tie_Set-XP.pdf|12/4/2017]]
|[[Media:TRF PQL TS MEM Simpson Strong-Tie Set-XP.pdf|12/4/2017]]
|
|
|}
|}
Line 2,994: Line 2,867:
|[http://www.freymfgcorp.com Frey Manufacturing Corp.]
|[http://www.freymfgcorp.com Frey Manufacturing Corp.]
|Rivet Nut/Insert Nut: Part Number IN1/4<br>Installation Tool: Part Number WT1/4
|Rivet Nut/Insert Nut: Part Number IN1/4<br>Installation Tool: Part Number WT1/4
|TBD
|[[Media:TRF PQL TS MEM Frey RivetNutAndTool.pdf|12/4/2017]]
|[[Media:TRF_PQL_TS_CAT_FreyMfg_RevitNutAndTool.JPG|Revit Nut with Tool and Bolt]]
|[[Media:TRF PQL TS CAT FreyMfg RevitNutAndTool.JPG|Revit Nut with Tool and Bolt]]
|-
|-
|
|
|[https://www.fastenal.com/ Fastenal]
|[https://www.fastenal.com/ Fastenal]
|[[Media:TRF_PQL_TS_CAT_Fastenal_RivetNutsRibbedFlangeHead.pdf|Rivet Nut 1/4-20 .165-.260]]
|[[Media:TRF PQL TS CAT Fastenal RivetNutsRibbedFlangeHead.pdf|Rivet Nut 1/4-20 .165-.260]]
|[[Media:TRF_PQL_TS_MEM_Fastenal_RivetNutsRibbedFlangeHead.pdf|12/4/2017]]
|[[Media:TRF PQL TS MEM Fastenal RivetNutsRibbedFlangeHead.pdf|12/4/2017]]
|
|
|-
|-
|
|Expendable tool listed as well for installation.
|[http://avkfasteners.com/products.AR.php AVK Industrial Products]
|[http://avkfasteners.com/products.AR.php AVK Industrial Products]
|[[Media:TRF_PQL_TS_CAT_AVK_ARThreadedInsert.pdf|Threaded Insert ARS4T-420-500]]
|[[Media:TRF PQL TS CAT AVK ARThreadedInsert.pdf|Threaded Insert ARS4T-420-500]]<br>
|[[Media:TRF_PQL_TS_MEM_AVK_ARThreadedInsert.pdf|12/4/2017]]
[[Media:TRF PQL TS CAT AVK AVKHandTool.pdf|Expendable Tool AAT916-420]]
|
|[[Media:TRF PQL TS MEM AVK ARThreadedInsert.pdf|12/4/2017]]
|-
|Expendable Tool
|[http://www.hweckhardt.com/products/by-manufacturer/avk-threaded-inserts/avk-tools/manual-avk-tools/aat916-420.html H.W. Eckhardt Corporation]
|[[Media:TRF_PQL_TS_CAT_AVK_AVKHandTool.pdf|AAT916-420]]
|TBD
|
|
|}
|}

Revision as of 16:31, 7 November 2023

Return to Approved Materials
Side arrow 80x66.png

Contractor Submittal Forms

GeekNotesIcon.png Note: This document is provided as a benefit to contractors and suppliers who are bidding projects for the City of Overland Park. Only products identified on this list will be approved for installation on City construction projects. This list shall not be used as a substitute for catalog cuts or material approval. All material approvals shall be submitted on the approved City of Overland Park Contract Project Submittal form. The form is available at City Hall by contacting Bruce Wacker at (913) 895-6027. Failure to comply will be cause for rejection of materials until proper submittals are received. This list is updated periodically. The contractor or supplier shall contact the City of Overland Park to make sure that they have the most current list prior to bidding a project. Failure to do so shall not constitute a legitimate claim for change orders. Before accessing any links, the City recommends that the user delete browsing history to insure the latest catalog cut information is displayed correctly.


Anchor Bolts

Anchor Bolts For Signal Mast Arm Poles

Notes Manufacturer Catalog Number Approval Date Photos
JH Botts Anchor Bolt Detail
1 1/2" x 54" x 6":
6 UNC 2A x 10" (54" + 6") GALV 20"
1 3/4" x 84" x 6":
5 UNC 2A x 10" (84" + 6") GALV 20"
2" x 84" x 6":
4 1/2 UNC 2A x 10" (84" + 6") GALV 20"
1/21/15
Millerbernd Use Column for "Part No. Bolt w/2 Nuts & 2 Flat Washers"
1 1/2" x 54" x 6": 460A579-12DNFW
1 3/4" x 84" x 6": 460A579-4DNFW
2" x 84" x 6": 460A579-5DNFW
7/30/15
Madden Bolt Corp fabricates for Union Metal Union Metal 1 1/2" x 54" x 6": 311657
1 3/4" x 84" x 6": 311658
2" x 84" x 6": 311659
7/5/16
Comment:
ASTM F1554 GR55
Threads shall be rolled

Anchor Bolts For Pedestal Signal Poles

Notes Manufacturer Catalog Number Approval Date Photos
Component Products, Inc CPI-AB-18 4/24/14
Gades Sales PB-5518-GLV 4/24/14
JH Botts .750"-10 UNC 2A x 6" (17" + 3") GALV 20" 1/21/15
Pelco Products, Inc. PB-5518-GLV 4/23/14
Comment:
ASTM A36, Gr 50 or Gr 55
Threads shall be rolled
17" - 18" Length

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Backplates (Vehicular)

Standard Vehicular Backplates

Notes Manufacturer Catalog Number Approval Date Photos
Gades Sales / Neodesha Plastics BP481PO – 1 section
BP483PO – 3 section
BP484PO – 4 section
BP485PO – 5 section
5/5/03
Mid American Signal For Econolite or North American Signal Heads
MI-1003-L2 – 3 section
For McCain Signal Heads
MI-1003-N – 3 section
5/5/03
Mobotrex / Eagle For Mobotrex / Eagle Signal Heads
BVD501ANFXX0N0-00 – 1 section
BVD503ANFXX0N0-00 – 3 section
BVD504ANFXX0N0-00 – 4 section
Where XX = 02 for AstroBracket and 05 for SkyBracket
BVD503TNF050N0-00 – HAWK
3/25/19
Pelco Products, Inc. For Econolite or North American Signal Heads
BK-1001-L3 – 1 section
BK-1003-L3 – 3 section
BK-1004-L3 – 4 section
BK-1005-L3 – 5 section

BK-2032-L3 - HAWK

For McCain Signal Heads
BK-1001-N – 1 section
BK-1003-N – 3 section
BK-1004-N – 4 section
BK-1005-N – 5 section

BK-2032-N - HAWK
5/5/03
Comment:
0.125” thick
12” Signal Head Sections

Flexible Vehicular Backplates

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use Only Pelco Products Inc. Universal AeroFlex Options
Standard
BK-8000-3-PNC - 3 Section
BK-8000-4-PNC - 4 Section
With Fluorescent Border
BK-8000-3-RT2-PNC - 3 Section
BK-8000-4-RT2-PNC - 4 Section


Eagle DuraSig-Specific Poly AeroFlex Options
Standard
BK-8100-3-EagleSG-PNC - 3 Section
BK-8100-4-EagleSG-PNC - 4 Section
With Fluorescent Border
BK-8100-3-EagleSG-RT2-PNC - 3 Section
BK-8100-4-EagleSG-RT2-PNC - 4 Section


McCain Specific Poly AeroFlex Options
Standard
BK-8100-3-McCain-PNC - 3 Section
BK-8100-4-McCain-PNC - 4 Section
With Fluorescent Border
BK-8100-3-McCain-RT2-PNC - 3 Section
BK-8100-4-McCain-RT2-PNC - 4 Section

8/2/19 Front View
Back View
Connection
Comment:
Universal backplates will fit McCain 12" Poly, Econolite 12" Poly, TCT/Peek 12" Poly

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Cable

CNG Monitoring Cable/Illuminated Street Name Sign Cable

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 8103 5/5/03
Falcon Fine Wire 980314X19-1 4/24/08 Label
Cable
Comment:
1-3c#14 IMSA 19-1

CNG Power Cable 1-3c #2AWG

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 302
UL File # E197262
5/20/16 Cable
Label
E File No.
Acquired by Southwire Coleman Cable Inc. 41112 MTW Cable 11/5/12 Cable
Service Wire Co USE2BK 5/7/02
Southwire #2 AWG stranded copper
Comment:
600 Volt Copper soft drawn stranded copper #2 AWG

Electrical Service Cable

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Diital Cable 304
UL file # E197262
5/20/16 Mfg Label
AWG Label
Cable
Alan Wire 04USE11 – 500’
UL file #E319493
1/30/12 Cable
E-File
Label
Member of The Marmon Group of Companies Cerro Wire & Cable Co, Inc. 1201-4401-Black
1201-4402 - White
1201-1105 - Green

UL file # E11098
5/5/03
Part of the Prysmian Group Draka 388932 7/8/09
Encore Wire LTD UL file # E174428 8/1/03 Cable
E-File
Kris Tech Wire Co, Inc. 0407-RHW/USE-BK
UL file # E207249
11/24/03 Cable
Label
Service Wire Co USEVW4BK
UL file # E105667
5/7/02 Cable
Label
Southwire Co 113472 – Black
476565 – White
952663 - Green

UL file # E32071
5/5/03
Comment:
No. 4 AWG USE Copper
Single cable, not three cables twisted on the reel

Emergency Vehicle Pre-emption (EVP) Detector Cable

Notes Manufacturer Catalog Number Approval Date Photos
Belden 580461 11/7/05 Cable
Global Traffic Technologies Model 138 3/24/08 Cable

Induction Loop Cable 1c#14

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 8450 6/29/09
Belden 580206 6/17/03
Falcon Fine Wire 14-1 IMSA 51-5 4/20/01
James Monroe Wire and Cable Corporation IMSA 51-5 9/1/99
Comment:
IMSA Type 51-5 Tube Loop Detector Cable
PVC/nylon Insulated cable
PVC Tube
600 Volt

Multi-conductor 7c#14 and 2c#14

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable / Clifford of Vermont 7c – 8107 / 7C14B7I19-1
2c – 8102 / 2C14B7I19-1
5/5/03 2 Condctor Cable
7 Conductor Cable
Mylar Wrap
Label
Not a standard product
but they will produce
Belden 7c – 601205
2c – 601457
2/1/01 Label
Cable
Falcon Fine Wire 7c – 980714X19-1-00
2c – 980214X19-1-00
5/23/05 7c Label
7c Mylar Wrap
7c Cable
2c Label
2c Mylar Wrap
2c Cable
James Monroe Wire and Cable Corporation 7c – IMSA 19-1
2c – IMSA 19-1
9/1/99
Comment:
IMSA 19-1
600 Volt
Stranded Copper
#14 AWG

Micro loop Home Run

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies bought out 3M Global Traffic Technologies Model Canoga 30003 5/20/03

Radar Detector Home Run Cable

Notes Manufacturer Catalog Number Approval Date Photos
Allied Wire & Cable 091102WGP12 1/10/11
Falcon Fine Wire 532P2218HD-08
2 pair 22 AWG communication wires
1 pair 18 AWG power wires
11/13/14 Separated Cable
Bundled Cable
"Matrix Advance" Label
Label showing wire guage
Orion Wire / Wavetronix WX-SS-H705 1/10/11
Comment:
2 pair 22 AWG communication wires (blue, blue/white, orange, orange/white)
1 pair 20 AWG power wires (red and black)
1 drain cable, unless otherwise shown


Radar Detector Harness Cable

Notes Manufacturer Catalog Number Approval Date Photos
Orion Wire / Wavetronix WX-SS-H704-100 1/10/11
Comment:
100’ harness to be spliced to home run cable at pole base
Cable harness to be supplied with the detector.


Shielded Detector Lead-in 2c#14

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable 8780 6/29/09 Cable
Belden 601765 2/1/01 Cable
Falcon Fine Wire 98021450-2 5/5/06 Cable
Label
Shield and Drain Wire
James Monroe Wire and Cable Corporation JM43465 9/1/99
Comment:
IMSA Type 50-2 Loop Lead-in Cable
Polyethylene Insulated
600 Volt
Stranded Copper
#14 AWG

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

#10 AWG System Ground Wire and Tracer Wire

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable Green - 410GN
Red - 410RD

UL File # E208489
5/20/16 Ground Cable
Mfg Label
AWG Label
Tracer Cable
Cerowire Wire & Cable Co., Inc. Red – 112-3803
Green – 112-3805
UL file # E15119
5/5/03
Encore Wire LTD UL file # E123774 8/1/03
Republic Wire UL File E167613 5/8/23 Label Name
Label Cable Type
Label UL File
Southwire Green - 22-97-73
Red - 22-97-57
UL file # E23919
5/5/03
Comment:
Stranded copper #10 AWG THHN/THWN-2
600 volt
Tracer wire shall have Red insulation
Ground wire shall have Green insulation

#6 AWG Equipment Ground Wire

Notes Manufacturer Catalog Number Approval Date Photos
Advanced Digital Cable BC06S 5/20/16 Bare Copper Cable
Cerro Wire & Cable Co, Inc. Product Number
050-2200 or 050-2215
5/5/03
Encore Wire LTD Bare No. 6 AWG 8/1/03
Service Wire Co BSOS6 5/5/03
Southwire Bare No. 6 AWG 5/5/03
Comment:
Bare copper soft drawn solid copper #6 AWG

Video Detection Cable

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Exclusive Falcon Fine Wire 970316TS-00-1MP 1/30/12 Cable
Jacket
Econolite Exclusive Isotec X339313-00 (for Econolite Solo Terra Systems) 4/25/08 Cable
Comment:
16 AWG/3c

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Conduit and Fittings

HDPE Signal Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Blue Diamond Industires 1" - BDI114BK-WHS
1 ½” - BDI164BK-WHS
2" - BDI214BK-WHS
3" - BDI314BK-WHS
4" -BDI414BK-WHS
3/9/23 1 ½” Cond Line Code
2" Cond Line Code
3" Cond Line Code
4" Cond Line Code
End View
Dura-Line 1” – HDP100RSDR013SWBLKWHTNEMPT
1 ½” – HDP150RSDR013SWBLKWHTNEMPT
2” – HDP200RSDR013SWBLKWHTNEMPT
3” – HDP300RSDR013SWBLKWHTNEMPT
4” – HDP400RSDR013SWBLKWHTNEMPT
1/09/17
Comment:
Include "City Traffic" in the product line code
SDR 13.5 Black with 3 longitudinal white stripes
Smooth wall
UV Stabilized

HDPE Service Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Blue Diamond Industries 2" - BDI214BK-RDS
3" - BDI314BK-RDS
3/9/23
Dura-Line 2” – 2SDR135BLK/RED
3” – 3SDR135BLK/RED
3/8/13
Comment:
SDR 13.5 Black with three longitudinal red stripes
Smooth wall
UV Stabilized

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

HDPE Couplings

Notes Manufacturer Catalog Number Approval Date Photos
American Polywater Bonduit Conduit Adhesive
Use with standard Sch 40 PVC Couplings
10/11/10 Cartridge
Equipment
Nozzle
Cabletec HDPE to HDPE Coupling:
1" - AS 1.315
1-1/2" - AS 1.900
2" - AS 2.375
3" - AS 3.500
4" - AS 4.500

HDPE to PVC Coupling:
1" - ASP 1.315
1-1/2" - ASP 1.900
2" - ASP 2.375
3" - ASP 3.500
4" - ASP 4.500
8/2/01




12/22/17
Dura-Line HDPE to HDPE Coupling or HDPE to PVC Coupling:
ShurLock Couplings
1" - 20000118
1 ½” – 20000122
2" - 20000123 (1-400761)
3" - 20000173
4" - 20000245
7/11/14 Side View
Label View
End View
Georg Fischer/Central Plastics Company HDPE to HDPE Electrofusion Couplings
1 ½” - 5760028
2” - 5760030
3” - 10000358
4” - 10000360
5/5/06

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Schedule 40 PVC Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Part of Atkore International Allied Tube & Conduit 1" - 4010010 (10' length)
1" - 4010020 (20' length)
1 ½” - 4015010 (10' length)
1 ½” - 4015020 (20' length)
2" - 4020010 (10' length)
2" - 4020020 (20' length)
3" - 4030010 (10' length)
3" - 4030020 (20' lengths)
4" - 4040010 (10' length)
4" - 4040020 (20' length)
8/30/23
Cantex 1” – A52BA12
1 ½” – A52BE12
2” – A52CA12
3” – A52DA12
4” – A52EA12
5/5/03
Part of Atkore International Heritage Plastics 1” – 511010 (10’ length)
1" - 511020 (20’ length)
1 ½” – 511510 (10’ length)
1 ½” - 511520 (20’ length)
2” – 512010 (10’ length)
2" - 512020 (20’ length)
3” – 513010 (10’ length)
3" - 513020 (20’ length)
4” – 514010 (10’ length)
4" - 515020 (20’ length)
7/24/12
IPEX / Scepter 1” – 032410 – 10’or 032411 – 20’
1 ½” – 032415 – 10’or 032416 – 20’
2” – 032420 – 10’ or 032421 – 20’
3” – 032430 – 10’ or 032431 – 20’
4” – 032440 – 10’ or 032441 – 20’
12/22/05
Prime Conduit 1” – 49008-010 (10’ length)
1” – 49008-020 (20’ length)
1 ½” – 49010-010 (10’ length)
1 ½” – 49010-020 (20’ length)
2” – 49011-010(10’ length)
2” – 40911-020 (20’ length)
3” – 49013-010 (10’ length)
3” – 49013-020 (20’ length)
4” – 49015-010 (10’ length)
4” – 49015-020 (20’ length)
5/26/09
Rocky Mountain Colby Pipe 1" – 504010010U (10' length)
1" – 504010020U (20' length)
1 1/2" – 504015010 (10' length)
1 1/2" – 504015020U (20' length)
2” – 504020010U (10’ length)
2" – 504020020U (20’ length)
3” – 504030010U (10’ length)
3" – 504030020U (20' length)
4” – 504040010U (10’ length)
4" – 504040020U (20’ length)
4/7/09
Comment:
Schedule 40

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Schedule 80 PVC Conduit

Notes Manufacturer Catalog Number Approval Date Photos
Part of Atkore International Allied Tube & Conduit 1" - 8010010 (10' length)
1" - 8010020 (20' length)
1 ½” - 8015010 (10' length)
1 ½” - 8015020 (20' length)
2" - 8020010 (10' length)
2" - 8020020 (20' length)
3" - 8030010 (10' length)
3" - 8030020 (20' lengths)
4" - 8040010 (10' length)
4" - 8040020 (20' length)
8/30/23
Cantex 1” – A53BA12
1 ½” – A53BE12
2” – A53CA12
3" – A53DA12
4" – A53EA12
1/29/19
Part of Atkore International Heritage Plastics 1” – 9304 (10’ length)
1" – 9504 (20’ length)
1 ½” – 9306 (10’ length)
1 ½” – 9506 (20’ length)
2” – 9308 (10’ length)
2" – 9508 (20’ length)
3” – 9312 (10’ length)
3" – 9512 (20’ length)
4” – 9316 (10’ length)
4" – 9516(20’ length)
1/29/19
IPEX / Scepter 1” – 032510 (10’length)
1” – 032511 (20’ length)
1 ½” – 032515 (10' length)
1 ½” – 032516 (20' length)
2” – 032520 (10’length)
2" – 032521 (20’ length)
3” – 032530 (10’ length)
3" - 032531 (20’ length)
4” – 032540 (10’ length)
4" – 032541 (20’ length)
1/29/19
Prime Conduit 1” – 49408-010 (10’ length)
1” – 49408-020 (20’ length)
1 1/2" – 49410-010 (10' length)
1 1/2" – 49410-020 (20' length)
2” – 49411-010 (10’ length)
2” – 40911-020 (20’ length)
3” – 49413-010 (10’ length)
3” – 49413-020 (20’ length)
4" – 49415-010 (10' length)
4" – 49415-020 (20' length)
1/29/19
Rocky Mountain Colby Pipe 1" – 508010010U (10' length)
1" – 508010020U (20' length)
1 1/2" – 508015010 (10' length)
1 1/2" – 508015020U (20' length)
2” – 508020010U (10’ length)
2" – 508020020U (20’ length)
3” – 508030010U (10’ length)
3" – 508030020U (20' length)
4” – 508040010U (10’ length)
4" – 508040020U (20’ length)
1/29/19
Comment:
Schedule 80 PVC shall only be used in above ground applications or exposed on the underside of bridge decks.

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Schedule 40 PVC Fittings

Notes Manufacturer Catalog Number Approval Date Photos
Part of Atkore International Allied Tube & Conduit Standard Couplings:
 1” – 59603
 1 ½” – 59605
 2” – 59606
 3" – 59608
 4" – 59610

90º Elbows 36” Radius for Power:
(Plain End) / (Bell End)

 2” – 59730 / NA
90º Elbows: (Plain End / Belled End)
 1” – 59590 / 802754
 1 ½” – 59592 / 802756
 2” – 59593 / 807757
 3” – 59595 / 802759
 4" – 59597 / 802762
45º Elbows:(Plain End / Belled End)
 1” – 59577 / 802768
 1 ½” – 59579 / 802770
 2” – 59580 / 802771
 3” – 59582 / 802773
 4” – 59584 / 802775
30º Elbows: (Plain End / Belled End)
 1” – 59563 / 802780
 1 ½” – 59565 / 802782
 2” – 59566 / 802783
 3" – 59568 / 802785
 4” – 59570 / 802787

9/3/14
Cantex Standard Couplings:
1” – 6141625
1 ½” – 6141627
2” – 6141628
3” – 6141630
4” - 6141632

90º Elbows 36” Radius for Power:
(Plain End) / (Belled End)

2” – 5133848 / 5233848
90º Elbows: (Plain End / Belled End)
1” – 5133825 / 5233825
1 ½” – 5133827 / 5233827
2” – 5133828 / 5233828
3” – 5133830 / 5233830
4” – 5133832 / 5233832
45º Elbows: (Plain End / Belled End)
1” – 5133765 / 5233765
1 ½” – 5133767 / 5233767
2” – 5133768 / 5233768
3” – 5133770 / 5233770
4” – 5133772 / 5233772
30º Elbows: (Plain End / Belled End)
1” – 5133745 / 5233745
1 ½” – 5133747 / 5233747
2” – 5133748 / 5233748
3” – 5133750 / 5233750
4” – 5133775 / 5233776

5/5/03
Part of Atkore International Heritage Plastics Standard Couplings:
1” – 610002
1 ½” – 610004
2” – 610005
3” – 610007
4” – 610009

90º Elbows 36” Radius for Power:
(Plain End) / Belled End)

2” – 611353 / 611140
90º Elbows: (Plain End / Belled End)
1” – 611002 / 611058
1 ½” – 611004 /611060
2” – 611005 / 611061
3” – 611007 / 611063
4” – 611009 / 611065
45º Elbows: (Plain End / Belled End)
1” – 611016 / 611071
1 ½” – 611018 / 611073
2” – 611019 / 611074
3” – 611021 / 611076
4” – 611023 / 611078
30º Elbows: (Plain End / Belled End)
1” – 611030 / 611085
1 ½” – 611032 / 611087
2” – 611033 / 611088
3” – 611035 / 611090
4” – 611037 / 611092

7/24/12
IPEX / Scepter Standard Couplings:
1” – EC20 / 077003
1 ½” – EC30 / 077005
2” – EC35 / 077006
3” – EC45 / 077008
4” – EC55 / 077010

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

2” – 068765 / 068054
90º Elbows: (Plain End / Belled End)
1” – EE2090 / EE2090B
1 ½” – EE3090 / EE3090B
2” – EE3590 / EE3590B
3” – EE4590 / EE4590B
4” – EE5590 / EE5590B
45º Elbows: (Plain End / Belled End)
1” – EE2045 / EE2045B
1 ½” – EE3045 / EE3045B
2” – EE3545 / EE3545B
3” – EE4545 / EE4545B
4” – EE5545 / EE5545B
30º Elbows: (Plain End / Belled End)
1” – EE2030 / NA
1 ½” – EE3030 / NA
2” – EE3530 / NA
3” – EE4530 / NA
4” – EE5530 / NA
22.5º Elbows: (Plain End / Belled End)
1” – NA / NA
1 ½” – EE1522 / NA
2” – EE2022 / NA
3” – EE3022 / NA
4” – EE4022 / NA

12/22/05
Formerly Carlon Prime Conduit Standard Couplings:
1” – CP100
1 ½” – CP150
2” – CP200
3” – CP300
4” – CP400

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

2” – UA9FJ / UA9FJB
90º Elbows: (Plain End / Belled End)
1” – UA9AF / UA9AFB
1 ½” – UA9AH / UA9AHB
2” – UA9AJ / UA9AJB
3” – UA9AL / UA9ALB
4” – UA9AN / UA9ANB
45º Elbows: (Plain End / Belled End)
1” – UA7AF / UA7AFB
1 ½” – UA7AH / UA7AHB
2” – UA7AJ / UA7AJB
3” – UA7AL / UA7ALB
4” – UA7AN / UA7ANB
30º Elbows: (Plain End / Belled End)
1” – UA6AF / UA6AFB
1 ½” – UA6AH / UA6AHB
2” – UA6AJ / UA6AJB
3” – UA6AL / UA6ALB
4” – UA6AN / UA6ANB

5/26/09

Schedule 80 PVC Fittings

Notes Manufacturer Catalog Number Approval Date Photos
Part of Atkore International Allied Tube & Conduit Standard Couplings:
 1” – 59603
 1 ½” – 59605
 2” – 59606
 3" – 59608
 4" – 59610

90º Elbows 36” Radius for Power:
(Plain End / Bell End)

 2” – 597394 / 926011
90º Elbows: (Plain End / Belled End)
 1” – 59014 / 924949
 1 ½” – 59016 / NA
 2” – 59017 / 924970
 3” – 59019 / 924993
 4” – 59021 / 925006
45º Elbows:(Plain End / Belled End)
 1” – 59002 / NA
 1 ½” – 59004 / 903486
 2” – 59005 / 924967
 3” – 59007 / 924990
 4" – 59009 / 925006
30º Elbows: (Plain End / Belled End)
 1” – 59066 / NA
 1 ½” – 59068 / NA
 2” – 59069 / NA
 3" – 59071 / NA
 4” – 59072 / NA

1/29/19
Cantex Standard Couplings:
 1” – 6141625
 1 ½" – 6141627
 2” – 6141628
 3" – 6141630
 4" – 6141632

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

 2” – 5121021 / 5121047
90º Elbows: (Plain End / Belled End)
 1” – 5121055 / NA
 1 ½” – 5121057 / 5221057
 2” – 5121058 / 5221058
 3” – 5121060 / 5221060
 4” – 5121061 / 5221061
45º Elbows:(Plain End / Belled End)
 1” – 5121005 / NA
 1 ½” – 5121007 / 5221007
 2” – 5121008 / 5221008
 3” – 5121010 / 5221010
 4” – 5121011 / 5221011
30º Elbows: (Plain End / Belled End)
 1” – 5121002 / NA
 1 ½” – 5121850 / NA
 2” – 5121108 / NA
 3" – 5121110 / NA
 4” – 5121111 / NA
22.5º Elbows: (Plain End / Belled End)
 1” – NA / NA
 1 ½” – 5136649 / NA
 2” – 5136659 / 5221052
 3" – 5136679 / 5236679
 4” – 5121868 / 5221868

1/29/19
Part of Atkore International Heritage Plastics Standard Couplings:
 1” – 59603
 1 ½" – 59605
 2” – 59606
 3” – 59608
 4" – 59610

90º Elbows 36” Radius for Power:
(Plain End) / (Belled End)

 2” – 597394 / 926011
90º Elbows: (Plain End) / (Belled End)
 1” – 59014 / 924949
 1 ½" – 59016 / NA
 2” – 59017 / 924970
 3" - 59019 / 924993
 4" – 59021 / 925006
45º Elbows: (Plain End) / (Belled End)
 1” – 59002 / NA
 1 ½" – 59004 / 903486
 2” – 59005 / 924967
 3” – 59007 / 924990
 4" – 59021 / 925003
30º Elbows: (Plain End) / (Belled End)
 1” – 59066 / NA
 1 ½" – 59068 / NA
 2” – 59069 / NA
 3” – 59071 / NA
 4" – 59072 / NA

1/29/19
IPEX / Scepter Standard Couplings:
 1” – EC20
 1 ½” – ED30
 2” – EC35
 3” – EC45
 4" – ED55

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

 2” – 068775 / NA
90º Elbows: (Plain End / Belled End)
 1” – 80EE2090 / NA
 1 ½” – 80EE3090 / NA
 2” – 80EE3590 / NA
 3” – 80EE4590 / NA
4" - 80EE5590 / NA
45º Elbows: (Plain End / Belled End)
 1” – 80EE2045 / NA
1 ½” – 80EE3045 / NA
 2” – 80EE3545 / NA
 3” – 80EE4545 / NA
4" – 80EE5545 / NA
30º Elbows: (Plain End / Belled End)
 1” – 80EE2030 / NA
1 ½” – 80EE3030 / NA
 2” – 80EE3530 / NA
 3” – 80EE4530 / NA
4" – 80EE5530 / NA

1/29/19
Prime Conduit Standard Couplings:
 1” – CP100
 1 ½” – CP150
 2” – CP200
 3" – CP300
 4” – CP400

90º Elbows 36” Radius for Power:
(Plain End / Belled End)

 2” – UB9FJ / UB9FJB
90º Elbows: (Plain End / Belled End)
 1” – UB9AF / UB9AFB
 1 ½” – UB9AH / UB9AHB
 2” – UB9AJ / UB9AJB
 3” – UB9AL / UB9ALB
 4” – UB9AN / UB9ANB
45º Elbows: (Plain End / Belled End)
 1” – UB7AF / UB7AFB
 1 ½” – UB7AH / UB7AHB
 2” – UB7AJ / UB7AJB
 3” – UB7AL / UB7ALB
 4” – UB7AN / UB7ANB
30º Elbows: (Plain End / Belled End)
 1” – UB6AF / UB6AFB
 1 ½” – UB6AH / UB6AHB
 2” – UB6AJ / UB6AJB
 3” – UB6AL / UB6ALB
 4” – UB6AN / UB6ANB
22.5º Elbows: (Plain End / Belled End)
 1” – UB5AF / UB5AFB
 1 ½” – UB5AH / UB5AHB
 2” – UB5AJ / UB5AJB
 3” – UB5AL / UB5ALB
 4” – UB5AN / UB5ANB

1/29/19
Comment:
To be used with Schedule 80 PVC conduit

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Bridge Expansion Couplings

Notes Manufacturer Catalog Number Approval Date Photos
Allied Tube & Conduit 1" - 789648
1 ½” - 789650
2" - 789651
3" - 789653
4" - 789655
5/2/14
Cantex 1” – 5144033
1 ½” – 5144035
2” – 5144036
3” – 5144038
4” – 5144040
5/5/03
IPEX / Scepter 1” – EJ20
1 ½” – EJ30
2” – EJ35
3” – EJ45
4” – EJ55
9/26/13
Prime Conduit 1” – EC2PC100
1 ½” – EC2PC150
2” – EC2PC200
3” – EC2PC300
4” – EC2PC400
9/26/13

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Controller Cabinet

ATC Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Single Wide: ATCC1201
Double Wide: ATCC1202
6/16/22
McCain Single Wide: 352i
Double Wide: 353i
11/15/18 Single Cabinet Front View
Clean Power Bus
Field Input Terminal
Input/Output Assembly
Power Assembly
Rear View
Surge Protector
Mobotrex 352 ATC Single Wide
353 ATC Double Wide: Drawing - JBS2353TOP01-Rev 2
11/3/21 Double Cabinet Front View
Field Input Terminal
Input/Output Assembly
Power Assembly
Rear View
Surge Protector
Comment:
Includes the following:
24 channel input assembly
16 channel output assembly
8" cabinet riser
Corbin Locks
MOV's for field outputs
Rear mounted field output terminals and field input terminal panels
Rear facing panel terminals for pedestrian and EVP
4 fans and 2 thermostats in the double cabinets and 2 fans and 1 thermostat in single cabinets

332 Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use Only McCain Model 332 / M35378 10/12/11

333 Double Pad Mount Traffic Signal Cabinet

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use Only McCain Model 333JP-OPKS 6/16/10
Comment:
These should be fabricated to “Overland Park Special” configurations

Detection Systems

Pedestrian Pushbuttons ADA Audible

Notes Manufacturer Catalog Number Approval Date Photos
The iNS mounting brackets are compatible with iNS or iN buttons. Polara Engineering, Inc. iNS iNavigator 3-Wire APS
iNS33TN1-X Push Button Station w/ 9”x15” frame
iPHCU3W Ped Head Control Unit

Accessories
iNS-EXT-LL-PC-X Straight Mounting Extender
iNS-EXTANG-LL-PC-X Angled Mounting Extender
iNS-EXTHTRED-PC-X Curved Mounting Extender
iNSPA4x2-B Dual Mounting Bracket Flexible
iNS-90DEGADPTR-PC-X 90-Degree Adaptor
1/6/2021
The iNS 3-Wire
is backwards compatible
with the iN 3-Wire.
New iNS mounting brackets
will be required to mount an iNS button.
For Maintenance Use
Only
Polara Engineering, Inc. iN iNavigator 3-Wire APS
iN33TN1-X Push Button Station w/ 9”x15” frame

Accessories
iN-EXT-LL-PC-X Straight Mounting Extender
iN-EXTANG-LL-PC-X Angled Mounting Extender
iN-EXTHTRED-PC-X Curved Mounting Extender
iNPBF2S-4.5-PC-X Dual Mounting Bracket
iNPA4x2-B Dual Mounting Bracket Flexible
iN-90DEGADPTR-PC-X 90-Degree Adaptor
12/21/2018 Station Front View
Station Cover Removed
For Maintenance Use
Only/or as Specified
Polara Engineering, Inc. EZ Communicator Navigator 4-Wire APS
9”x15” frame – EN43TN1-PY (std pole)
PHCU4W - Included Power Unit
NPA4X2-y (adapter for pedestal pole)
800H-84 - Sign Option
Optional Sound Baffle: ENAV-SB
Optional Frame Extender: 6" - PBFE-06 or 12" PBFE-12
1/23/13 Front View
Button
Back View
Comment:
Red LED indicator
Auto volume adjustment for ambient noise levels
LL = Length of Extension: 06 for 6" or 12 for 12"
X = Color: B for Black or Y for Yellow.
Audible locator tones shall be set to be audible 6 to 12 feet from the push button, or to the building line, whichever is less.
A percussive tone is required where an APS is provided at a signle crossing or where two APS are 10' or more from each other at a corner.
Custom Message (Recorded at Factory w/ electronic copy sent to City) where the APS are less than 10' apart.

For standard signal poles, the color of the frame, bracket, and adapter, if used, shall be powder coated yellow. The extender shall remain galvanized with no color.
For decorative signal poles, the color of the extender, frame, bracket, and adapter, if used, shall be powder coated black.

Pedestrian Pushbuttons

Notes Manufacturer Catalog Number Approval Date Photos
For Maintenance Use Only/or
as Specified
Polara Engineering, Inc. Bulldog Series
Push Button Assembly: BDSP-010-X

Pole Mount Adaptor: BDPM3-X

Accessories For Maintenance Use Only/or as Specified

Push Button Frame 2C with 9"x15" Plate Adapter: PBF2C-9x15-X
Straight Mounting Extender: iNS-EXT-LL-PC-X
Angled Mounting Extender: iNS-EXTANG-LL-PC-X
Curved Mounting Extender: iNS-EXTHTRED-PC-X
90-Degree Adaptor: iNS-90DEGADPTR-PC-X

Approved for use, but no longer being manufactured as of January 2021:
Straight Mounting Extender: iN-EXT-LL-PC-X
Angled Mounting Extender: iN-EXTANG-LL-PC-X
Curved Mounting Extender: iN-EXTHTRED-PC-X
Dual Mounting Bracket: iNPBF2S-4.5-PC-X
Dual Mounting Bracket Flexible: iNPA4x2-B
90-Degree Adaptor: iN-90DEGADPTR-PC-X

1/26/15
Comment:
Yellow body with sound on actuation
NO LED Flash
LL = Length of Extension: 06 for 6" or 12 for 12"
X = Color: B for Black or Y for Yellow.

For standard signal poles, the color of the frame, bracket, and adapter, if used, shall be powder coated yellow. The extender shall remain galvanized with no color.
For decorative signal poles, the color of the extender, frame, bracket, and adapter, if used, shall be powder coated black.

Emergency Vehicle Pre-empt (EVP) Detectors

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies Model 721 2/218/08 Side View
Cable Terminal
Comment:
Two Direction Single Channel

Pre-formed Detector Loop

Notes Manufacturer Catalog Number Approval Date Photos
Never-Fail Loop Systems Model A – in or under asphalt
Model C – in concrete or bridge decks
6/6/00
Patriot Detection Model CG16MM 9/1/15
Purchased by EDI Reno Rectangular Loop: Model PLH-XX-YY
Quadrupole Loop: Model PLH-XX-YY-ZZ
7/7/16

Advance Radar Detectors

Notes Manufacturer Catalog Number Approval Date Photos
Wavetronix Model WX-SS-200V SmartSensor Advance Unit
SDLC Cabinet Interface Device
6 Terminal Ports: Arc6 102-0594 (WX-500-0417)
Includes Surge Card: 102-0562 (WX-500-0381)
1/10/11
Comment:
Include the SDLC Cabinet Interface Module

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Presence Radar Detectors

Notes Manufacturer Catalog Number Approval Date Photos
Iteris 4 Approaches with Presence Detection Only
Detection System: RAD-SYS-4-BH-SM-TS2
Includes CCU, 4 Sensors, Power Supply and Surge Protection

Individual Parts:
Presence Detector Sensor: RAD-SENSOR-BH-PAK
CCU: RAD-CCU-SM4-TS2-PAK
Surge Protection Device: ASCO - HVCP-48-4RJ45
Presence Plus Advance Detector Sensor: RADPL-SENSOR-BH-PAK
Mounting Brackets:
CAMBRKT4

3/11/21 CCU
CCU Side
Power Supply
Power Supply Side
Surge Protector
Bracket
Wavetronix Model WX-SS-225 SmartSensor Matrix Presence Unit
SDLC Cabinet Interface Device
6 Terminal Ports: Arc6 102-0594 (WX-500-0417)
Includes Surge Card: 102-0562 (WX-500-0381)
5/30/13 SDLC Interface Front View
SDLC Interface Back View
SDLC Interface Iso View
SDLC Interface Surge Protector Card
Sensor Cable Ports
SDLC Module Wire Plug
Comment:
For Wavetronix:
Include the SDLC Interface Module

Vehicle Detectors (Loops)

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies
bought out 3M
Global Traffic Technologies
/ 3M / Canoga
Model C922 – Two Channel
Model C924 – Four Channel
2/18/08
Purchased by EDI Reno Model C-1200-SS Series – Two Channel
Model E-1200-SS Series – Four Channel
2/10/12
Comment:
It shall have TS2 status output available

Video Detection Systems

Notes Manufacturer Catalog Number Approval Date Photos Comments
Used for Maintenance Replacements Only Econolite/Autoscope Encore MVP Image Sensor: AENCORENP
Interface Panel: ATIP1
Access Point: ATAPE
Interface Cable Kit: ASTCBL10
SDLC Cable Harness: 33550G5
9/11/13 Easy-Lock Harting Connector
On-Board Ethernet Port
SDLC Cable Harness for TS-2 Comm to ASC/3 – Rack Mount Controller
Used for Maintenance Replacements Only Econolite/Autoscope Terra Rack Vision AIS Image Sensor: AIS4HCRZOOMU0S
Camera Interface Panel: AIPx
Coaxial Jumper Cable: RG59
Processor Card: ARVTERRA1E
SDLC Cable Harness: 33550G5
5/17/07 Easy-Lock Harting Connector
x = number of cameras to be connected to the interface panel (1 to 6)
On-Board Ethernet Port
Used for Maintenance Replacements Only Gridsmart Fisheye Camera Assembly: GS3-SMK
Processor: GS-3-GS2
Fisheye Camera Replacement Only: GS-3-CAM
Mounting Bracket: GS-3-CBL
5/20/20 Fisheye Camera Side View
Pole Assembly
Camera Mount
Junction Box
Processor
RJ-45 Connector
Cable Harness
One CPU handles 1 fisheye camera and up to 3 traditional cameras or 2 fisheye cameras
Used for Maintenance Replacements Only ITS PLUS3, Inc. Advanced VIVDS Camera: ITSP-PM120C

Dual Channel VIVDS Card w/ Ethernet: ITSP-V200E
4 Way Coax Surge Suppression Panel: ITSP-SSP-4
SDLC Module: ITSP-SDLC
Siamese Coax/Power Cable: ITS-Cable

1/27/17 Camera Front
Detection Card

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Grounding Equipment

Ground Rod

Notes Manufacturer Catalog Number Approval Date Photos
Erico Inc. 5/8” x 8’-0” Cat. No. 615880
5/8” x 10’-0” Cat. No. 615800
2/27/02
Galvan Industries 5/8" x 8'-0" Cat. No. 6258
5/8" x 10'-0: Cat. No. 6260
12/20/13
Hubbell 5/8" x 8’-0” Cat. No. C615880
5/8” x 10’-0” Cat No. C635800
4/24/12
Thomas & Betts 5/8” x 8’-0” Cat. No. 6258
5/8” x 10’-0” Cat No. 6260
5/5/03
Comment:
5/8” x 10’-0” long at poles and controller cabinet
5/8” x 8’-0” long at service boxes
Copper clad steel core
UL listed

Ground Rod Clamp

Notes Manufacturer Catalog Number Approval Date Photos
Burndy GRC58 – 5/8” 2/27/02 Clamp
Erico Inc. HDC58 – 5/8” 12/1/05
Galvan Industries SRC – 5/8” 12/20/13
Thomas & Betts JAB58H - 5/8" 5/5/03
Comment:
Hex head set screw
Copper alloy
Long bearing surface
UL listed

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Junction and Service Boxes

Type 1 Junction Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001423TA – Assembly
A6001422T – Cover only
A6001423 – Box only
1/11/01
New Basis Cover Label
PCB121212-00000 – Box only
PCC1212PC1-90005 – Cover only
PCA121212-00030 - Assembly
8/8/03 Side View
Top View
Cover
Bolt Hole
Oldcastle Infrastructure 12122001 - Body Only
12124405 - Lid Only
6/5/14
Quazite was purchased
by Hubbell Power Systems
Quazite PC1212BA12 – Box only
PC1212HA0046 – Cover only
PC1212Z50346 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
1 Piece cover to be ¾” min thick
Straight wall
No mouseholes
3/8” – 16 NC stainless steel hex head bolts and washers

Type 2 Junction Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001429TA - Assembly
A6001428T – Cover only
A6001429 – Box only
7/30/01 Side View
Top View
Bottom View
New Basis Cover Label
PCB111812-00000 – Box only
PCC11181P1-90019 – Cover only
PCA111812-00030 - Assembly
8/8/03 Side View
Top View
Cover
Oldcastle Infrastructure 11182001 - Body Only
11184611 - Lid Only
11181613 - Unit
6/5/14
Quazite was purchased
by Hubbell Power Systems
Quazite PG1118BA12 – Box only
PG1118HA0046 – Cover only
PG1118Z50946 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
1 Piece cover to be 2” thick
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Type 1 Service Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001974TAPCX24 - Assembly
A6001975T – Cover only
A6001974PCX24 – Box only
7/30/01 End View
Top View
Bottom View
Channell Commercial Corp BULKU243624F061010 - Assembly
BULKUA2436E061010 - Cover only
BULKUA2436240 - Box only
8/5/16 Cover Ground Wire
New Basis Cover Label
PCB24362400000 – Box only
PCC2436P1-00030 – Cover only
PCA243624-00030 – Assembly
2/26/02
Oldcastle Infrastructure 24362214 - Body Only
24364613 - Lid Only
24361616 - Unit
6/5/14
Quazite was purchased
by Hubbell Power Systems
Quazite PG2436BA24 – Box only
PG2436HA0046 – Cover only
PG2436Z50246 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
1 Piece cover to be 3” thick
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Type 2 Service Box

Notes Manufacturer Catalog Number Approval Date Photos
Armorcast A6001430TAPCX24 – Assembly
A6001470T (2 pc. Req.) – Cover only
A6001430PCX24 – Box only
7/30/01 Side View
End View
Channell Commercial Corp BULKU304824F081010 - Assembly
BULKUA3048E081010 - Cover Only
BULKUA3048240 - Box only
8/5/16 Cover Ground Wire
New Basis Cover Label
PCB30482400000 – Box only
PCC3048P2-90039 – Cover only
PCA304824-00062 – Assembly
2/26/02 Side View
Oldcastle Infrastructure 30482021 - Body Only
30484611 - Lid Only
6/5/14
Quazite was purchased
by Hubbell Power Systems
Quazite PG3048BA24 – Box only
PG3048HS0046 – Cover only
PG3048Z52546 - Assembly
Cover Codes
5/5/03
Comment:
Minimum Box Assembly Rating - Tier 15 (22,500 lbs test load)
Logo to read “Traffic Signal”
2 Piece cover to be 3” thick underlapping
Straight wall
No mouseholes
3/8” – 16 NC hex head bolts and washers

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

LED Units

Red LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 432-1314-001XOD15 11/13/19 Front View
Back View
Label
Leotek TSL-12RA-DT-A1 11/13/19 Front View
Back View
Comment:
Tinted lens
Incandescent look
15 Year Warranty

Yellow LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 431-3334-901XOD15 11/13/19 Front View
Back View
Label
Leotek TSL-12YA-DT-A1 11/13/19 Front View
Back View
Comment:
Tinted lens
Incandescent look
15 Year Warranty

Green LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 432-2324-001XOD15 11/13/19 Front View
Wiring
Leotek TSL-12GA-DT-A1 11/13/19 Front View
Back View
Comment:
Tinted lens
Incandescent look
15 Year Warranty

Bi-Modal Green/Yellow LED Arrow

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 430-6370-001 4/30/10
GE DR6-ECA6-21A 12/8/16
Leotek TSL-12BM-LD-A1 4/3/18 Front View
Back View
Label
Comment:
Clear Lens, pixilated arrow

Red Ball LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight DuraLED 433-1210-003XL15 11/13/19 Front View
Back View
Label
Leotek TSL-12R-DT-A1 11/13/19 Front View
Back View
Comment:
Tinted lens
Incandescent look
15 Year Warranty

Yellow Ball LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight DuraLED 433-3230-901XL15 11/13/19 Front View
Back View
Label
Leotek TSL-12Y-DT-A1 11/13/19 Front View
Back View
Yellow Ball Label
Comment:
Tinted lens
Incandescent look
15 Year Warranty

Green Ball LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight DuraLED 433-2220-001XL15 11/13/19 Front View
Back View
Label
Leotek TSL-12G-DT-A1 11/13/19 Front View
Back View
Comment:
Tinted lens
Incandescent look
15 Year Warranty

Countdown Pedestrian LED

Notes Manufacturer Catalog Number Approval Date Photos
DiaLight 430-6479-001X 4/30/10
GE GTX City Series: PS7-CFF1-VLA 12/8/16 Front View
Back View
Gasket
Countdown View
Leotek TSL-PED-16-SPC-V1 4/3/18 Front View
Label
Back View
Comment:
16” X 18”
Hand/Person display symbol
Orange/White display color
Incandescent look
Filled/Overlay Style
9” Numerals

Loop Sealants

Notes Manufacturer Catalog Number Approval Date Photos
3M 5000 5/5/03
Purchased by Royal Adhesives & Sealants
Under acquisition by HB Fuller
Chemque Q-Seal 290S - Grey or Black 10/23/03
Crafco Inc RoadSaver 221, Part No. 34221 5/5/03
Ruscoe Highway Products Permanent Sealer 974 – Gray or Black 7/3/13

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Miscellaneous Controller Equipment

ATC Cabinet Specific Equipment

ATC Controller

Notes Manufacturer Catalog Number Approval Date Photos
Econolite 2070EOS1D6500 w/EOS 11/8/21
McCain ATC eX 2070 PN: M46541 10/16/18
Q-Free / Intelight YCT-2070LX-MT

Individual Component Parts:
Controller: 2070LX
FIO Module: 2070-2E+
1C CPU Module: 2070-1C
Software:MAXTIME 1C
11/4/21
Comment:
With Data Key
Firmware shall be provided with the controller

ATC Cabinet Power Supply

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc PS-2216-24-HV 10/16/18
Comment:
Used only in ATC Cabinet.

Auxiliary Display Unit (ADU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. ADU 10/16/18
Comment:
Used only in ATC Cabinet

Cabinet Alarm Panel

Notes Manufacturer Catalog Number Approval Date Photos
Econolite 177-1018-501 6/16/22
McCain Traffic 2521 - Cabinet Alarm Panel and Harness 11/3/21 Front View
Back View
Mobotrex AAD18150-001 11/8/21
Comment:
Used only in ATC Cabinet

Cabinet Monitor Unit (CMU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. CMUip-2212-HV 10/16/18 Front View
Side View
Comment:
Used only in ATC traffic signal cabinet in place of the conflict monitor

ATC Flasher

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. 2202-HV 10/16/18 Front View
Side View
Comment:
Used only in ATC Cabinet.
Part is also used for the High Density Switch Pack / Load Switch in ATC Cabinet

High Density Flash Transfer Relay

Notes Manufacturer Catalog Number Approval Date Photos
Struthers-Dunn 21XBXHL-48VDC 10/16/18 Front View
Side View
Comment:
Used only in ATC Cabinet.

High Density Switch Pack / Load Switch

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. 2202-HV 10/16/18
Comment:
Used only in ATC Cabinet.
Part is also used for the Flasher in ATC Cabinet

Serial Interface Unit (SIU)

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design Inc. SIU-2218 10/16/18 Front View
Comment:
Only used in ATC Cabinet

General Cabinet Equipment

1C CPU Module

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Model 2070-1C 2/15/17 Front View
Side View
Comment:
For use in upgrading existing 2070 controllers only

AC Isolator

Notes Manufacturer Catalog Number Approval Date Photos
GDI Communications ACIM252 5/5/03
PDC / Power Distribution & Control ACI-88 Model 252 5/5/03
Comment:
Model 252

Auxiliary Output File

Notes Manufacturer Catalog Number Approval Date Photos
McCain Traffic CABSP-1521020033X KS 2/26/20 Front View
Back View
Top View
Comment:
With AC Jumper for 15 Pin Connection

Conflict Monitor

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design, Inc. 2018 KCLip – (Std 332 Cabinet) with
Datakey programming and Ethernet port
2/19/09 Front View
Side View
Comment:
Not used with Hybrid Cabinet. See “Malfunction Management Unit” below
Not used with ATC Cabinet. See “Conflict Management Unit” below

Controller

Notes Manufacturer Catalog Number Approval Date Photos
For Hybrid Cabinets Only Safetran/Econolite Control Products, Inc. Model Cobalt-C 2/26/16 Front View
Back View
Comment:
With Data Key
Firmware shall be provided with the controller

DC Isolator

Notes Manufacturer Catalog Number Approval Date Photos
EDI 242L 10/12/21 Front View
GDI Communications DIM242 5/5/03
PDC / Power Distribution & Control DCI-82 Model 242 5/5/03 Front View
Side View
Comment:
Model 242
Not used with Hybrid Cabinet. See “Detector Test Switch Module” below.

Flash Transfer Relay

Notes Manufacturer Catalog Number Approval Date Photos
Purchased by EDI Reno A&E TR-200 11/3/05 Side
Back
Struthers-Dunn W21ACPX-2 8/6/20 Front
Comment:
Model 430
Not used with ATC Cabinet. See “High Density Flash Transfer Relay” below

Flasher Unit

Notes Manufacturer Catalog Number Approval Date Photos
EDI / Eberle Design, Inc. EDI 204 5/5/03
GDI Communications FL204 5/5/03
PDC / Power Distribution & Control SSF-88 5/5/03
Purchased by EDI Reno A&E FL-200 11/3/05
TSC / Traffic Sensor Corp TSC 204 5/5/03
Comment:
Model 204
Not used with ATC Cabinet. See “High Density Switch Pack” below

Power Distribution Assembly (PDA)

Notes Manufacturer Catalog Number Approval Date Photos
McCain PDA#2 M63186 7/14/10

Power Distribution Surge Protection Unit

Notes Manufacturer Catalog Number Approval Date Photos
MTL Instruments Group
is the umbrella company
Cooper/Crouse-Hinds/
Atlantic Scientific
RP35326 10/28/2008 Front View
Back View
Top View
Indicator Lights
Geist Manufacturing, Inc. SPX084-10 11/4/05
Comment:
Room for 4 to 6 transformer spaced outlets on one side and 4 to 6 standard outlets on the other side
15 amp breaker
Rack mounted
NEMA 5-15

Power Supply

Notes Manufacturer Catalog Number Approval Date Photos
EDI Model 206L 7/9/10
Comment:
High efficiency power saving w/ solid state transfer relay

Pre-empt Phase Selectors / Discriminator Module

Notes Manufacturer Catalog Number Approval Date Photos
Global Traffic Technologies Model 762 – Two Channel
Model 764 – Four Channel
Model 768 Auxiliary Interface Panel (If specified)
4/19/11 764 Phase Selector
Comment:
With Ethernet Ports

Switchpack / Load Switch

Notes Manufacturer Catalog Number Approval Date Photos
GDI Communications LS200-6 5/5/03
PDC / Power Distribution & Control SSS-87IO 5/5/03 Front View
Side View
Purchased by EDI Reno A&E LS-200 11/3/05 Front View

Side View
Back View
End View
Label

TSC / Traffic Sensor Corp TSC200 5/5/03
Comment:
Model 200 with Input and Output monitoring
Not used with ATC Cabinet. See “High Density Switch Pack” above

Surge Protector (Traffic Signal Cabinet)

Notes Manufacturer Catalog Number Approval Date Photos
Edco/Emerson Network Power SHA-1250 w/ SHA-1250-BASE-A 8/5/10
Hesco/RLS HE1750 10/16/18
Comment:
For Hybrid, 332 and ATC Cabinets

Utility Power Surge Protector (Secondary Service Enclosure)

Notes Manufacturer Catalog Number Approval Date Photos
Partners with Pentair Engineered
Electrical & Fastening Systems
Nvent/Erico / Critec TDX-100S120240 11/26/14 Top View
Pull Out Drawer
Top Inside View
Replacement Module
Comment:
Note: NEMA-4 weather tight housing
Output contacts
Replaceable cartridge overcurrent fuse protection
Replaceable modules
Event timer

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Hybrid Cabinet Specific Equipment

Bus Interface Unit (BIU)

Notes Manufacturer Catalog Number Approval Date Photos
Maintenance Use Only EDI / Eberle Design Inc. BIU-700H 10/17/18
Maintenance Use Only Econolite 160-1003-505 10/6/11 Front View
Side View
Comment:
½ width design - Only used with Hybrid Cabinet

Malfunction Management Unit (MMU)

Notes Manufacturer Catalog Number Approval Date Photos
Maintenance Use Only EDI / Eberle Design Inc. MMU2-16-LE(ip) 1/10/13 Front View
Back View
Comment:
Only used in Hybrid traffic signal cabinet in place of the conflict monitor

K1 Control Relay

Notes Manufacturer Catalog Number Approval Date Photos
Maintenance Use Only Econolite Dwg No. 54408 Rev U 4/6/15
Maintenance Use Only Tyco Electronics /
Potter & Brumfield
KRPA-14AGP-120 2/10/11 Side View
Comment:
Only used with Hybrid Cabinet

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Mounting Brackets

Mast Arm Signal Head Bracket

Notes Manufacturer Catalog Number Approval Date Photos
Pelco AG-0125-1-LL-PXX (1-Section)
AG-0125-3-LL-PXX (3-Section)
AG-0125-4-LL-PXX (4-Section)


AG-0168-LL-PXX (HAWK)
4/19/19






4/19/19
Open Hinge View
Top View
Side View
A Division
of Olson
Aluminum
Castings
Sky Bracket SS-SBLL-18 (1-Section)
SS-SBLL-46 (3-Section)
SS-SBLL-60 (4-Section)


SS-SBLL_HPB-18 (HAWK)
1/11/19



1/11/19
Shown with previously approved cable mounting system.
Front View
Side View
Back View
Lower Arm
Upper Arm
Tube Section
Comment:
Stainless steel banding/cable and hardware
For Pelco:
Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
62" – for mast arm diameters ranging from 2” to 7”
84" – for mast arm diameters ranging from 7.1” to 10.5”
96" – for mast arm diameters ranging from 10.6” to 12.4”
110" – for mast arm diameters ranging from 12.5” to 14.6”
120" – for mast arm diameters ranging from 14.7” to 16.2”
132" – for mast arm diameters ranging from 16.3” to 18.2”
Color (XX) shall be as follows:
NC - No Color
33 - Glossy Black
71 - RAL6012 Green
39 - RAL8019 Dark Bronze
For Sky Bracket:
Required band length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
29” – for mast arm diameters ranging from 2” to 7”
42” – for mast arm diameters ranging from 8” to 11”
59” – for mast arm diameters ranging from 12” to 17”
If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat

Mini Pre-empt Detector Bracket

Notes Manufacturer Catalog Number Approval Date Photos
Pelco Products, Inc. Band Mount
Astro Brac AB-0155-LL-PXX
Cable Mount
Astro Brac AB-0163-LL-PXX
1/11/19

12/29/04
Sky Bracket SBLL-MM-075 11/25/19 Back

Back Angle
Front

Comment:
Stainless Steel banding or cable mount
LL = Banding Length Based on Mast Arm Diameter:
29” – for mast arm diameters ranging from 2” to 7”
42" – for mast arm diameters ranging from 8” to 11”
59" – for mast arm diameters ranging from 12” to 17)
LL = Cable Length Based on Mast Arm Diameter:
45" - for mast arm diameters ranging from 2" to 11"
62" - for mast arm diameters ranging from 11.1" to 16.6"
84" - for mast arm diameters ranging from 16.7" to 22"
Color (XX) shall be as follows:
NC - No Color
33 - Glossy Black
71 - RAL6012 Green
39 - RAL8019 Dark Bronze

Radar Detector Mounting Bracket

Notes Manufacturer Catalog Number Approval Date Photos
For a Presence sensor
mounted on a mast arm.
For an Advance sensor
mounted on a mast arm.
Pelco Inc. SP-5987-23-LL-PXX 8/6/19 Open Hinge View
Top View
Side View
For a Presence sensor
mounted on a mast arm.
For an Advance sensor
mounted on a mast arm.
Sky Bracket Bracket:
SS-SBLL-ACM-24

Burle Style Adapter Plate: SB-PLT
1/11/19 Showing previously
approved cable
mounting system.
Front View
Side View
Back View
Mounting End
Tube Section
For a Presence sensor
mounted on a vertical pole.
For an Advance sensor
mounted on a mast arm or a vertical pole.
Wavetronix WX-SS-611 4/29/16 Top View
Side View
Connection Segments
Comment:
Stainless steel banding/cable and hardware
For Pelco:
Required cable length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
62" – for mast arm diameters ranging from 2” to 7”
84" – for mast arm diameters ranging from 7.1” to 10.5”
96" – for mast arm diameters ranging from 10.6” to 12.4”
110" – for mast arm diameters ranging from 12.5” to 14.6”
120" – for mast arm diameters ranging from 14.7” to 16.2”
132" – for mast arm diameters ranging from 16.3” to 18.2”
Color (XX) shall be as follows:
NC - No Color
33 - Glossy Black
71 - RAL6012 Green
39 - RAL8019 Dark Bronze
For SkyBracket:
Required banding length (LL) to be determined by contractor based on manufacturer's recommendations as follows:
29” – for mast arm diameters ranging from 2” to 7”
42” – for mast arm diameters ranging from 8” to 11”
59” – for mast arm diameters ranging from 12” to 17”
If other than standard color, specify SB-BLK for Black Powder Coat or SP-SPL for Special Color Powder Coat

Side Mount Signal Head and Pedestrian Signal Head Bracket

Notes Manufacturer Catalog Number Approval Date Photos
Auto/Eagle UKS-1452X 5/5/03
Component Products, Inc. TSP880-X 5/5/03
Gades UKS1452X / PDM-405 5/5/03
Comment:
Yellow polycarbonate
X=Y for Yellow
X= B for Black

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Poles

Aluminum Pedestal Poles

Notes Manufacturer Catalog Number Approval Date Photos
Component Products, Inc Square Pedestal Base: CPI-BAS-1-P

Pole Cap: CPI-APC-1
9’ Pedestal Pole: CPI-AP-9-40
13’ Pedestal Pole: CPI-AP-13-40
14’ Pedestal Pole: CPI-AP-14-40

Base Collar: CPI-RBC-1

4/24/14 Base
Gades Sales Square Pedestal Base: PB-5335-1S-GL-PNC

Pole Cap: PB-5402-PNC
9’ Pedestal Pole: PB5100-9-PNC
13’ Pedestal Pole: PB5100-13-PNC
14’ Pedestal Pole: PB5100-14-PNC

Base Collar: PB-5325-PNC

4/24/14 Side View
Bottom View
Threaded Opening
Cover
Pelco Products, Inc. Square Pedestal Base: PB-5335-1S-GL-PNC

Pole Cap: PB-5402-PNC
9’ Pedestal Pole: PB-5100-9-PNC
13’ Pedestal Pole: PB-5100-13-PNC
14’ Pedestal Pole: PB-5100-14-PNC

Base Collar: PB-5325-PNC

4/23/14 Base
Base & Collar
Comment:
See "Anchor Bolts" for part number information
Pole tube is schedule 40
Include base collar with every pole
Set screws required in base collar
Include 2 7/8” OD x 7/8” ID galvanized flat washers
Include anchor bolts

Galvanized Steel Signal Poles

Notes Manufacturer Catalog Number Approval Date Photos
Millerbernd Manufacturing Company 1994 AASHTO: 780B661
2013 AASHTO: 780B1885 Rev D
Identification Label: Single Arm  : Double Arm
8/10/10
11/10/14
Union Metal 1994 AASHTO: 50915-B1 Rev 9
2013 AASHTO: 50915-B19 Rev 6.1
10/27/04
8/31/15
Valmont 1994 AASHTO: DB00175 Rev E
2013 AASHTO: DB01086 Rev H
1/26/12
7/28/14
Comment:
See "Anchor Bolts" for part number information
Shall meet 2013 AASHTO Criteria unless otherwise specified in the bid plans, documents and details
2013 AASHTO criteria is for a 50-year recurrence interval, fatigue category 2 but does not include design to resist galloping or truck induced gusts

Pedestrian Pushbutton Pole and Foundation

Notes Manufacturer Catalog Number Approval Date Photos
Frey Manufacturing Corp. Pedestrian Pushbutton Pole with Pole Cap:
CP6ACT4840TCSS / Dwg No. 8.1.0 Rev. 1
Pedestrian Pushbutton Pole Cap:
TCSS Top Cap with Set Screws for 4" Pipe / Dwg No. 8.4.1 Rev. 1
11/30/17 Pedestrian Pole
Breakaway Base
Breakaway Base Angle
Pedestal Door
Pole Cap
Bolts
Comment:
Frey Mfg pole requires approved Two-Part Epoxy.

Power Backup Systems

CNG Generators

Notes Manufacturer Catalog Number Approval Date Photos
Alpha Technologies AlphaGen CE-3x2-50-48 NG with Cold Weather Starting Kit
With PCC-3x Polymer Concrete Pre-Cast Pad
Includes Alpha supplied battery

DO NOT PROVIDE WITH TRANSFORMER AND FUSE
6/17/03
Comment:
48V DC output voltage
96 amp max DC output current
10.5 Hp single OHV engine
13.5 VDC Ignition Charger Voltage
6 amp max Ignition Charger Current
2800 to 3600 RPM variable speed
80 CuFt/hr Natural Gas, 1000 BTU/CuFt
0.5 – 2 PSI Gas Inlet Pressure

UPS Systems

Notes Manufacturer Catalog Number Approval Date Photos
SPO-09A2 may have been superseded with the SPO-09A3 per contractor email on 11/7/2023. Clary Stand Alone Battery Backup /UPS Unit
SP 1250-LX-R – Uninterruptible Traffic System with Integrated PIM and Programmable Display
SPO-09A2 – SNMP Adapter with cables manual and software
SPD-302C – Bypass Switch with GFCI and Generator Plug
SP-19N1 – Battery Cable
72-volt system
9/26/13 UPS Front View
UPS Contacts
Bypass Switch
Bypass Switch Label
Clary Combined Battery and CNG Backup Unit
SP 1250-LX-R-48 – Uninterruptible Traffic System with Integrated PIM and Programmable Display
SPO-09A2 – SNMP Adapter with cables manual and software
SPD-302C – Bypass Switch
100-16136 – 48 VDC Battery Generator Interface Box
104-16163-60 – 48 Volt Dual String Battery Cable
48-volt system
4/12/10 UPS Front View
UPS Contacts
Bypass Switch
Generator Interface Box
Comment:
Ethernet port capabilities
See Battery requirements below.
Use ONLY the specified batteries as listed for each UPS system as listed in the table below.

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Power Transfer Switches

Notes Manufacturer Catalog Number Approval Date Photos
Clary Corporation Switch: SPH-302
Mounting Bracket: SPH302-RHK
4/2/21 Front View
Cable Connections
UPS Connection View
Label
Comment:
This is used when there is not battery backup / UPS or CNG generator backup power specified

Batteries

Batteries for UPS

Notes Manufacturer Catalog Number Approval Date Photos Comments
Clary OP72C-41 – Batteries (set of six)
72-volt system (Stand alone BBS)
OP96C-41 – Batteries (set of eight)
48-volt system (Combined BBS/CNG)
10/7/11 Battery
Battery String
Absorbed Glass Mat (AGM)
Valve Regulated , Lead Acid (VRLA)

Batteries for CNG Generator

Notes Manufacturer Catalog Number Approval Date Photos Comments
Alpha Model 195 GXL 1/18/12 Gel Top AGM Terminal Battery (4 Year Full Replacement Warranty)

Rebar Support Products

Support Spacers

Notes Manufacturer Catalog Number Approval Date Photos
Foundation Technologies, Inc Drill Shaft Wheels:
SS406 - 3" Clearance
SS303 - 1 1/2" Clearance

Support Boots:
BB711
1/12/21
Pieresearch Drill Shaft Wheels:
6QLHD - 3" Clearance
4QLHD - 2" Clearance

Technical Drawing
Support Boots:
#5 - #14 Bars: 3PB
Technical Drawing
7/12/19
Rebar Support Products Drill Shaft Wheels:
DP300 - 3" Clearance
DP200 - 2" Clearance

Support Boots:
#3 - #8 Bars: BB38
#8 - #11 Bars: BB811
7/12/19
Comment:
Number of Wheels
Min number per tier: 4
Min spacing from top of shaft: 6'
Max spacing from bottom of shaft: 2'
Max spacing along shaft: 8'
Number of Pier Supports
One per every 1,500 lbs of cage weight
Min one on every other vertical bar

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Secondary Service Pedestals

Aluminum Electrical Service Enclosure

Notes Manufacturer Catalog Number Approval Date Photos
Myers Custom Products, Inc. MEA-IIVLM-TS-R-LB 4/19/19
Purchased by
Myers Custom Products, Inc
Pacific Utility Products USP2R-100-112C-OPK-TS-AL-LBP 2/17/12 Front View
Interior View
Meter Socket
Lock
Breaker
Bottom View
Comment:
0.125” Aluminum, 30 amp breaker
Corbin #2 lock on door
No photocell or lighting relays
Ringless Meter Socket with Lever By-Pass

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Battery Backup / Electrical Service Enclosure

Notes Manufacturer Catalog Number Approval Date Photos
USED ONLY FOR MAINTENANCE REPLACEMENTS Myers Custom Products, Inc. Cabinet – MET2-PB-M030-AC-EMI
Drawing No. F518506
8/23/05
USED ONLY FOR MAINTENANCE REPLACEMENTS Pacific Utility Products Cabinet – USP29-57-BBS 7/9/10
USED ONLY FOR MAINTENANCE REPLACEMENTS Traffic Signal Controls Cabinet – 2116UPME1401 9/3/09
Comment:
0.125” aluminum
Manual transfer switch behind police door
For use with external portable generator
See below for External Generator Receptacle data
20Amp breaker for CCTV Camera Disconnect

Battery Backup to CNG Electrical Service Enclosure

Notes Manufacturer Catalog Number Approval Date Photos
USED ONLY FOR MAINTENANCE REPLACEMENTS Myers Custom Products, Inc. Cabinet – MET2-PB-M030-DC-EMI
Drawing No. F518507
8/23/05
USED ONLY FOR MAINTENANCE REPLACEMENTS Pacific Utility Products Cabinet – USP29-57-BBS 7/9/10
USED ONLY FOR MAINTENANCE REPLACEMENTS Traffic Signal Controls Cabinet-2116UPME1401 9/3/09
Comment:
0.125” aluminum
For use with permanent CNG generator and gas service line
20Amp breaker for CCTV Camera Disconnect

CNG External Generator Receptacle

Notes Manufacturer Catalog Number Approval Date Photos
Hubbell HBL2710SW including HBL2715 flanged receptacle 4/2/12
Reliance Controls PK30 Power Inlet Kit, including L1430F flanged receptacle 4/2/12
Comment:
Twist Lock Recessed Male, 30 Amp 120/240 Volt, 4 prong including ground with outdoor hinged cover

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Signal Heads

Signal Head Louvers

Notes Manufacturer Catalog Number Approval Date Photos
Pelco GL-1010-X-UC-P02 11/14/14
Comment:
Geometrically programmed louver with black visor
X = 7, 8, 9, 11, 12, 15, 23.5 or 42 degrees depending on the cut-off angle desired.
The maximum number of louvers comes with the 7 degree cut-off
UC = Universal Clips
P02 = Black

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Vehicular Signal Heads

Notes Manufacturer Catalog Number Approval Date Photos
Econolite Control Products, Inc. Yellow Body:
TP11VJC2P0H0 for 1 Section
TP31VJC2P0H0 for 3 Section
TP41VJC2P0H0 for 4 Section

Black Body:
TP11VJF2P0H0 for 1 Section
TP31VJF2P0H0 for 3 Section
TP41VJF2P0H0 for 4 Section
5/9/03 Front View
Back View
Open Front View
Wiring Terminals
Latch
McCain Traffic Supply Yellow Body:
M22167-P for 1 Section
M22436-P for 3 Section
M31084-P for 4 Section

Black Body:
M22168-P for 1 Section
M22435-P for 3 Section
M30883-P for 4 Section


M19271 Black Poly Visors
5/14/13 Open Front View
Wiring Terminal
Side View
Latch
Label
Mobotrex / Eagle Signal Brochure
Yellow Body
SA101A1C11YBB10-37 for 1 Section
SA103A1C11YBB30-37 for 3 Section
SA104A1C11YBB40-37 for 4 Section
SA1031T3T1111YBB - HAWK

Black Body:
SA101A1C11BBB10-22 for 1 Section
SA103A1C11BBB30-37 for 3 Section
SA104A1C11BBB30-37 for 4 Section
SA1031T3T1111BBB - HAWK
5/5/03
North American Signal Yellow Body:
PT100YB-OTB-MAS for 1-Section
PT300YB-OTB-MAS for 3-Section
PT400YB-0TB-MAS for 4-Section

Black Body
PT100BB-0TB-MAS for 1-Section
PT300BB-0TB-MAS for 3-Section
PT400BB-0TB-MAS for 4-Section
11/15/19 Front
Back
Hinge
Side
Terminal
Thumb Screw
Label
Peek Traffic Yellow Body
PSS81S001FO for 1 Section
PSS83S003FO for 3 Section
PSS84S004FO for 4 Section


Black Body
PSS81E001FO for 1 Section
PSS83E003FO for 3 Section
PSS84E004FO for 4 Section
5/5/03
Comment:
Yellow Polycarbonate Body (Standard)
Black Polycarbonate Body (Special)
Black Polycarbonate Doors and Visors
Visors to be Tunnel Type
LED retrofit
12” Sections

Countdown Pedestrian Signal Heads

Notes Manufacturer Catalog Number Approval Date Photos
McCain Traffic Supply M31466 – Yellow housing
M31655 – Black housing
12/30/04
North American Signal PPYBP0_B1-MAS - Yellow housing
PPBBP0_B1-MAS - Black housing
11/15/19 Front
Bottom
Gasket
Hinge
Terminal
Label
Mobotrex / EagleSignal Drawing
SG7-S-Z10C0YB010-00 – Yellow housing
SG7-S-Z10C0BB010-00 – Black housing
9/20/11 Top View
Inside View
Latch
Comment:
Yellow polycarbonate body (Standard)
Black polycarbonate body (Special)
Black Door / No Z-Crate Visor
Port hole mount

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png

Wire Connectors

Wire Connectors for Loop Lead-In

Notes Manufacturer Catalog Number Approval Date Photos
King Innovation/Dryconn For 2 #14 AWG
Aqua/Orange Waterproof Connector
62110 - Card of 6
62125 - Bag of 25
62135 - Bag of 100
62150 - Bag of 500

For 2, 3, 4 or 5 #14 AWG
Auqua/Red Waterproof Connector
62210 - Card of 5
62225 - Bag of 20
62235 - Bag of 100
62250 - Box of 500

For 4, 5 or 6 #14 AWG
Aqua/Blue Waterproof Connector
62310 – Card of 3
62325 – Bag of 15
62335 – Bag of 50
62340 – Bag of 250
10/14/03 Aqua/Blue
Comment:
Wire Range: Min. #14 AWG / Max. #6 AWG Copper
Silicone Sealant Filled
Watertight/raintight

Wire Connectors for Multi-Conductor Signal Cable

Notes Manufacturer Catalog Number Approval Date Photos
King Innovation/Dryconn For 2, 3, 4 or 5 #14 AWG
King 4 Yellow: 10444 - Bag of 10
For 2, 3, 4 or 5 #14 AWG
King 5 Red: 10555 - Bag of 10
For 2, 3, 4 or 5 #14 AWG
King 6 Blue: 10670 - Box of 100
For 4, 5 or 6 #14
King 9 Dark Blue: 10975 - Box of 75
10/14/03 King 6 Blue
Comment:
Wire Range: Min. #22 AWG / Max. #8 AWG Copper
Silicone Sealant Filled
Direct Burial

Wire Connectors for Radar Detector Cable

Notes Manufacturer Catalog Number Approval Date Photos
3M Scotchlok Butt Connector:
UAL(BX) 100/box, 10 boxes/case
6/14/17 Top View
Side View
Comment:
Wire Range: Min. #24 AWG / #19 AWG Max. Copper

Epoxy

Two-Part Epoxy for Concrete

Notes Manufacturer Catalog Number Approval Date Photos
HILTI HIT-RE 500-V3 12/4/2017
ITW Commercial Construction Red Head Concrete Anchoring Solutions - A7+ 12/4/2017
Powers PE1000+ 12/4/2017
Simpson Strong-Tie SET-XP 12/4/2017
Comment:
Shall be classified as a concrete anchor for use in cracked or uncracked concrete.
Shall be dispensed with a dual-chamber cartridge with a static mixing nozzel which attaches to the cartridge.

Rivet Nuts

Rivet Nuts and Installation Tools for Pushbutton Poles

Notes Manufacturer Catalog Number Approval Date Photos
During pedestrian pushbutton pole ordering request appropriate number of rivet nuts and installation tool. Frey Manufacturing Corp. Rivet Nut/Insert Nut: Part Number IN1/4
Installation Tool: Part Number WT1/4
12/4/2017 Revit Nut with Tool and Bolt
Fastenal Rivet Nut 1/4-20 .165-.260 12/4/2017
Expendable tool listed as well for installation. AVK Industrial Products Threaded Insert ARS4T-420-500

Expendable Tool AAT916-420

12/4/2017
Comment:
Size 1/4-20 and Yellow Zinc Plated.
Drill 25/64" holes.
Other tools for rivet nut insertion available.
1/4"-20 x 1-1/2" phillips drive flat head stainless steel machine screw recommended for pushbutton attachment.

Up arrow 66x80.png Top Return to Approved Materials
Side arrow 80x66.png