{{PQLNote|Minimum Box Rating - Tier 15 (22,500 lbs test load)<br>Minimum Cover Rating - Tier 8 (12,000 lbs test load)<br>Cover Logo to read “Fiber Optics”<br>Cover to be 3” thick<br> | {{PQLNote|Minimum Box Rating - Tier 15 (22,500 lbs test load)<br>Minimum Cover Rating - Tier 8 (12,000 lbs test load)<br>Cover Logo to read “Fiber Optics”<br>Cover to be 3” thick<br>Straight wall<br>No mouseholes<br>3/8” – 16 NC hex head bolts and washers}} | ||
{{PQLReturn}} | {{PQLReturn}} | ||
Revision as of 15:41, 7 January 2014
Return to Complete Preapproved Materials Page
Cables
Loose Tube Fiber Optic Cable
Comment: | ||
Single Mode Fiber Non-Armored Loose Tube Cable |
Top | Return to Approved Materials |
Fiber Optic Plenum Cable
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Prysmian Group | F-800-12-ES-144-EB – 144 Count F-800-12-ES-72-EB – 72 Count F-800-12-ES-36-EB – 36 Count F-800-06-ES-06-EB – 6 Count |
10/24/13 |
Comment: | ||
Single Mode Fiber |
Fiber Optic Riser Cable
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Prysmian Group | F-400-12-ES-144-EB – 144 Count F-400-12-ES-72-EB – 72 Count F-400-12-ES-36-EB – 36 Count F-400-06-ES-06-EB – 6 Count |
10/24/13 |
Comment: | ||
Single Mode Fiber |
Fiber Optic Patch Cable
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
ICC | ICFOJ3M302 | 7/15/08 | Patch Cable | |
Major Custom Cables | FXDSLCST-XM | 8/7/09 | ||
Quiktron | 810-L27-006 V-Series 2F LC-ST (Drawing D100855) |
8/5/10 | Patch Cable LC Connector ST Connector |
Comment: | ||
ST-LC connectors, 6' duplex, single mode |
Top | Return to Approved Materials |
#10 AWG System Tracer Wire
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Cerowire Wire & Cable Co., Inc. | 112-3801-03-X | 5/5/03 | ||
Encore Wire LTD | UL file # E123774 | 8/1/03 | ||
Southwire | Red | 5/5/03 | ||
United Copper Industries | UL File E194031 | 5/26/09 | Jacket Label Cable |
Comment: | ||
Red Insulation Stranded copper #10 AWG THHN 600 volt |
Conduit and Couplings
HDPE Conduit
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Dura-Line now owns Arnco, Boreflex, Carlon and Lamson Pipe |
Dura-Line | 3” – 3SDR135ORG 2” – 2SDR135ORG |
3/28/13 |
Comment: | ||
SDR13.5 all sizes Orange color Smooth solid wall UV Stabilized |
Top | Return to Approved Materials |
HDPE Couplings
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
American Polywater | Bonduit Conduit Adhesive Use with standard Sch 40 PVC Couplings |
10/11/10 | Cartridge Equipment Nozzle | |
Cabletec | 2” – AS 2.375 3” – AS 3.500 |
8/2/01 | Coupling | |
Dura-Line | PushLock Couplings 2” – 1-908353 |
10/5/10 | ||
Georg Fischer Central Plastics | Electrofusion Couplings 2” IPS 5760012 3” IPS 5757007 |
5/5/06 | Side View Top View | |
Tyco Electronics / Jack Moon | Moon-Link Transparent Duct Coupling 2” – 794488-000 / JM-CML-20TC238SP 3” – 281826-000 / JM-CML-30TC350SP |
12/23/02 | Side View Label Top View |
Expansion Couplings
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Cantex | 1” – 5144033 1 ½” – 5144035 2” – 5144036 3” – 5144038 4” – 5144040 |
5/5/03 | ||
Heritage Plastics | 1” – 610276 1 ½” – 610278 2” – 610279 3” – 610281 4” – 610283 |
9/26/13 | ||
IPEX Electrical Inc. | Size / Part Number / Product Code 1” / EJ20 / 077383 1 ½” / EJ30 / 077385 2” / EJ35 / 077386 3” / EJ45 / 077388 4” / EJ55 / 077390 |
9/26/13 | ||
Prime Conduit Purchased Carlon |
Prime Conduit | 1” – EC2PC100 1 ½” – EC2PC150 2” – EC2PC200 3” – EC2PC300 4” – EC2PC400 |
9/26/13 | |
Formerly Plastic Trends Royal Pipe Systems |
Royal Building Products | 1” – E016100 1 ½” – E016150 2” – E016200 3” – E016300 4” – E016400 |
9/26/13 | |
Thomas & Betts Purchased Carlon |
Thomas & Betts | 1” – E945F 1 ½” – E945H 2” – E945J 3” – E945L 4” – E945N |
5/26/09 |
Top | Return to Approved Materials |
Repair Couplings
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Prime Conduit Purchased Carlon |
Prime Conduit | Split Duct Coupling 2” – 49011SD-010 3” – 49013SD-010 4” – 49015SD-010 |
5/26/09 | Assembly Parts Close Up |
Comment: | ||
Used to repair damaged fiber optic conduit when not feasible to remove fiber cable and re-splice |
Ethernet Switches
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Cisco Systems, Inc | Switch: IE-3000-8TC Power Supply: PWR-IE50W-AC SFP Fiber Modules: GLC-FE-100LX 100BASE-LX 19” Rack Mount Kit: STK-RACKMNT-2955 |
9/20/13 | Switch Switch and Rack SFP Module |
Comment: | ||
Hardened Ethernet Switch w/ DIN Rail Adapter 8 Ethernet 10/100 Ports & 2 SFP Fiber Ports |
Top | Return to Approved Materials |
Locating Materials
Tracer Cable
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Cerro Wire & Cable Co, Inc. | Red – 112-380103 UL file # E15119 |
5/5/03 | ||
Encore Wire LTD | UL file # E123774 | 8/1/03 | ||
Southwire | UL file # E14656 | 8/21/03 | ||
United Copper Industries | UL file # E194031-A | 5/26/09 | Cable Jacket Label |
Comment: | ||
Stranded copper THHN/THWN #10 AWG Red Jacket Insulation |
Ground Rods
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Erico Inc. / Eritech | Cat. No. 611380 | 2/27/02 | ||
Galvan Industries | Cat No. 5008L | 12/20/13 | ||
Hubbell/Chance | Cat. No. C611380 | 4/24/12 | ||
Purchased by Thomas & Betts |
Thomas & Betts / Blackburn | Cat. No. 5008 | 5/5/03 |
Comment: | ||
½” x 8’-0” long Copper clad steel core UL listed |
Top | Return to Approved Materials |
Ground Rod Clamp
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Burndy | GRC 12 | 2/27/02 | Clamp | |
Erico Inc. / Eritech | HDC12 – ½” rod | 12/1/05 | ||
Galvan Industries | SRC - 1/2" | 12/20/13 | ||
Purchased by Thomas & Betts |
Thomas & Betts / Blackburn | Type JAB-12H | 5/5/03 |
Comment: | ||
Hex head set screw Copper alloy Long bearing surface UL listed |
Service Boxes
Type 1 Fiber Optic Service Box
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Armorcast | A6001974PCX24 - Box only A6001975 - Cover only A6001974TAPCX24 - Assembly |
7/30/01 | ||
Highline | Product Number Nomenclature PHB243624 – Box only CHC2436HF – Cover only PHA2436HF2 – Assembly |
3/3/11 | Side View End View Bolt Hole Bolt Hole | |
Martin Enterprises | 243624PCB – Box only 2436PCC – Cover only 243624PC - Assembly |
10/17/11 | ||
New Basis | PCB243624A04 – Box only PCC243605A04 – Cover only |
2/26/02 | ||
Carson H Series boxes were purchased by Oldcastle |
Oldcastle | Part Number List 24366214 – Box only 24364016 – Cover only 24361206 – Assembly 80002029 hex head bolts if separate |
8/29/13 | Side View End View Top View Cover Bolt Hole |
Quazite was purchased by Hubbell Power Systems |
Quazite | PG2436BA24 – Box only PG2436CA0021 – Cover only Cover Codes |
5/05/03 | Side View End View Top View Bolt Hole |
Comment: | ||
Minimum Box Rating - Tier 15 (22,500 lbs test load) Minimum Cover Rating - Tier 8 (12,000 lbs test load) Cover Logo to read “Fiber Optics” Cover to be 3” thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers |
Top | Return to Approved Materials |
Type 2 Fiber Optic Service Box
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Armorcast | A6001430PCX24 - Box only A6001470 (2 pc. Req.) - Cover only A6001430TAPCX24 - Assembly |
7/30/01 | Side View End View | |
Highline | Product Number Nomenclature PHB304824 – Box only CHC3048HF-2PC – Cover only PHA304824HF4 – Assembly |
3/3/11 | ||
Martin Enterprises | 304824PCB – Box only 3048PCC – Cover only 304824PC - Assembly |
10/17/11 | ||
New Basis | PCB304824A04 – Box only PCC304815A04 – Cover only |
2/26/02 | ||
Carson H Series boxes were purchased by Oldcastle |
Oldcastle | Part Number List 30482021 – Box only 30484012 – Cover only 30481620 – Assembly 80002029 hex head bolts if separate |
8/29/13 | |
Quazite was purchased Hubbell Power Systems |
Quazite | PG3048BA24 – Box only PG3048CC0021 – Cover only Cover Codes |
5/5/03 |
Comment: | ||
Minimum Box Rating - Tier 15 (22,500 lbs test load) Minimum Cover Rating - Tier 8 (12,000 lbs test load) Cover Logo to read “Fiber Optics” Cover to be 3” thick Straight wall No mouseholes 3/8” – 16 NC hex head bolts and washers |
Top | Return to Approved Materials |
Splice Enclosures
Comment: | ||
Bell Type Enclosures |
Termination Drop Cables
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Fiber Connections, Inc. | Gator Patch 6 Fiber – G320G006FRB-Length 12 Fiber – G620G012FRB-Length |
1/10/06 | Top View Side View Bottom View | |
Major Custom Cable | Z-Stack 6 Fiber – FCZS6ASTUB 12 Fiber – FCZS12ASTUB |
3/23/09 | Top View Inside View |
Comment: | ||
6 or 12-Fiber – Single mode 6 or 12 port rack mount for ST connectors |
Top | Return to Approved Materials |
Terminal Servers
Notes | Manufacturer | Catalog Number | Approval Date | Photos |
Comtrol Network Enabling Devices | DeviceMaster RTS 1-Port Part Number 99435-0 |
9/1/05 | Top View Back View Ethernet Port Serial Port Power Cable Port |
Comment: | ||
Single Port Supply with 6’ CAT 5e Network Patch Cable |