Difference between revisions of "Approved Materials - Storm Drainage"

From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation Jump to search
Line 27: Line 27:


== Manhole Steps ==
== Manhole Steps ==
{{Specification|SPEC=[http://www.opkansas.org/doing-business/civil-engineering/construction-details '''Overland Park Standard Details''' (Precast Manhole Detail)]<br>[https://dw.opkansas.org/public/FileCabinets/2fa13812-70a3-4126-848b-3a20df7175c3/Documents/831/FileDownload?targetFileType=Auto&keepAnnotations=false '''Overland Park Construction Specifications''' - Chapter 33]}}
{{Specification|SPEC=[http://www.opkansas.org/doing-business/civil-engineering/construction-details '''Overland Park Standard Details''' (Precast Manhole Detail)]<br>[https://www2.opkansas.org/files/dw/api/Docs/11358?_ga=2.79047133.812859282.1646336000-1282489368.1646228585 '''Overland Park Construction Specifications''' - Section 815]}}


{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"

Revision as of 14:46, 3 March 2022

Return to Approved Materials

Inlet Frames

Applicable Specification:

Overland Park Standard Details (Area Inlet and Curb Inlet Details)
Inlet Frames
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
EJ Group, Inc. Curb Inlet 10” Throat 4/27/2017 Curb Inlet 10” Frame
Shawnee Steel & Welding Inc. Curb Inlet 10” Throat 4/27/2017 Curb Inlet 10” Frame
Shawnee Steel & Welding Inc. Area Inlet 10” Throat 4/27/2017 Area Inlet 10” Frame
Brown's Fabrication & Steel, LLC. Curb Inlet 10” Throat 6/26/2017 Curb Inlet 10” Frame
Brown's Fabrication & Steel, LLC. Area Inlet 10” Throat 6/26/2017 Area Inlet 10” Frame

Manhole Steps

Applicable Specification:

Overland Park Standard Details (Precast Manhole Detail)
Overland Park Construction Specifications - Section 815
Manhole Steps
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
American Step ML-13 3/27/2017 ML-13
American Step ML-10 3/27/2017 ML-10
MA Industries PS1-PF 3/27/2017 PS1-PF
MA Industries PS2-PF 3/27/2017 PS2-PF

Manhole Rings & Lids

Applicable Specification:

Overland Park Standard Details (Manhole Casting Detail)
Overland Park Construction Specifications - Chapter 33
Manhole Rings & Lids
Manufacturer Product Name or Number Type Approval Date Comment Catalog Cut Links
Castings from overseas shall have the coupon as required in AASHTO M-306 for testing.
EJ Group, Inc. 1501 A and Z Medium Duty 4/7/2017 1501
1502 A and Z Heavy Duty 4/7/2017 1502
Clay and Bailey N2161-CSTSWR Medium Duty 4/13/2017 N2161-CSTSWR
N2160-CSTSWR Heavy Duty 4/13/2017 N2160-CSTSWR

Sealants - Manhole

Applicable Specification:

Johnson County Wastewater Standard Details
Sealants - Manhole
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
Hamilton Kent No. 2 4/13/2017 Kent Seal No. 2
Trelleborg Bidco – C56 Butyl 4/13/2017 C56 Sealant
Press-Seal Corp. Pro-Stik 4/13/2017 Pro-Stik

Sealants - RCBs & Non-circular Pipe

Sealants - Pipe/RCBs
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
Blackhawk Mastic 4/14/2017 BH5401
Mar-Mac Manufacturing Mac-Wrap 4/14/2017 Mac-Wrap

Class III Concrete Pipe

Applicable Specification:

Overland Park Construction Specifications - Chapter 31
Class III Concrete Pipe
Manufacturer Pipe Size Wall Size Joint Design Gaskets Approval Date Catalog Cut Links
Pretech 15”-36” B Profile Hamilton Kent - Tylox Super Seal (HK TSS) 5/5/2017 RCP 15"-36"
Trelleborg Forsheda
Universal Polymer & Rubber 4/10/2018
Pretech 42”-78” B/C Profile HK TSS 5/5/2017 RCP 42"-78"
Forsheda
Universal Polymer & Rubber 4/10/2018
Forterra 12" C P4 (Profile) HK TSS135 5/5/2017
Forterra 15"-18" B/C P4 HK TSS135 5/5/2017
Forterra 21" B/C CX4 (Confined O-ring) Press Seal 21/32 5/5/2017
Forterra 24"-36" B/C P4 HK TSS135 5/5/2017
Forterra 42” B P3 HK TSS 185 5/5/2017
C CX4 Press Seal 25/32
Forterra 48” C P3 HK TSS 185 5/5/2017
CX4 Press Seal 25/32
Forterra 54” C P3 HK TSS 185 5/5/2017
CX4 Press Seal 25/32
Forterra 60", 66" C CX4 Press Seal 25/32 5/5/2017
Forterra 72", 78" C CX4 Press Seal 27/32 5/5/2017
Forterra 84", 90" B CX4 Press Seal 1 5/5/2017
Forterra 96", 144" B CX4 Press Seal 1-3/32 5/5/2017
Forterra 108", 120" B CX4 Press Seal 1-1/16 5/5/2017

Underdrains

Applicable Specification:

Overland Park Construction Specifications - Chapter 34
KDOT 822 and 1907 with modifications
Underdrains
Manufacturer Product Name or Number Type Approval Date Comment Catalog Cut Links
Contech A-2000 H 3/29/2017 A-2000
ADS N-12 T 3/29/2017 N-12
ADS AdvanEDGE T (Alt.) 4/14/2017 AdvanEDGE

Return to Approved Materials