Difference between revisions of "Approved Materials - Storm Drainage"

From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation Jump to search
 
(15 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[Preapproved_Materials|'''Return to Preapproved Materials''']]
[[Approved_Materials|'''Return to Approved Materials''']]
== Inlet Frames ==
== Inlet Frames ==
{{Specification|SPEC=[http://www.opkansas.org/Documents-and-Forms/List/Detail-Drawings Overland Park Standard Details]}}
{{Specification|SPEC=[http://www.opkansas.org/doing-business/civil-engineering/construction-details/ '''Overland Park Standard Details''' (Area Inlet and Curb Inlet Details)]}}
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
|+ '''Inlet Frames'''
|+ '''Inlet Frames'''
Line 27: Line 27:


== Manhole Steps ==
== Manhole Steps ==
{{Specification|SPEC=[http://www.opkansas.org/doing-business/civil-engineering/construction-details Overland Park Standard Details (Precast Manhole Detail)]<br>[http://www.opkansas.org/wp-content/uploads/2017_Design_and_Construction_Standards_Vol._2.pdf '''Overland Park Construction Specifications''' - Chapter 33]}}
{{Specification|SPEC=[http://www.opkansas.org/doing-business/civil-engineering/construction-details '''Overland Park Standard Details''' (Precast Manhole Detail)]<br>[https://www2.opkansas.org/files/dw/api/Docs/11358?_ga=2.79047133.812859282.1646336000-1282489368.1646228585 '''Overland Park Construction Specifications''' - Section 815]}}


{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
Line 51: Line 51:


== Manhole Rings & Lids ==
== Manhole Rings & Lids ==
{{Specification|SPEC=[http://www.opkansas.org/doing-business/civil-engineering/construction-details Overland Park Standard Details (Manhole Casting Detail)]<br>[http://www.opkansas.org/wp-content/uploads/2017_Design_and_Construction_Standards_Vol._2.pdf '''Overland Park Construction Specifications''' - Chapter 33]}}
{{Specification|SPEC=[http://www.opkansas.org/doing-business/civil-engineering/construction-details '''Overland Park Standard Details''' (Manhole Casting Detail)]<br>[https://www2.opkansas.org/files/dw/api/Docs/11358?_ga=2.79047133.812859282.1646336000-1282489368.1646228585 '''Overland Park Construction Specifications''' - Section 815]}}


{|width=800px border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"  
{|width=800px border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"  
Line 86: Line 86:


== Sealants - Manhole ==
== Sealants - Manhole ==
{{Specification|SPEC=Johnson County Wastewater Standard Details}}
{{Specification|SPEC=[https://www.jocogov.org/sites/default/files/documents/JCW/JCW-00%20Sanitary%20Sewer%20Standard%20Details.pdf '''Johnson County Wastewater Standard Details''']}}


{|width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"  
{|width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"  
Line 125: Line 125:


== Class III Concrete Pipe ==
== Class III Concrete Pipe ==
{{Specification|SPEC=[http://www.opkansas.org/wp-content/uploads/2017_Design_and_Construction_Standards_Vol._2.pdf '''Overland Park Construction Specifications''' - Chapter 31]}}
{{Specification|SPEC=[https://www2.opkansas.org/files/dw/api/Docs/11358?_ga=2.79047133.812859282.1646336000-1282489368.1646228585 '''Overland Park Construction Specifications''' - Section 817]}}


{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
Line 287: Line 287:


== Underdrains ==
== Underdrains ==
{{Specification|SPEC=[http://www.opkansas.org/wp-content/uploads/2017_Design_and_Construction_Standards_Vol._2.pdf '''Overland Park Construction Specifications''' - Chapter 34]<br>[http://www.ksdot.org/burconsmain/specprov/2015specprov.asp '''KDOT 822 and 1907''' with modifications]}}
{{Specification|SPEC=[https://www2.opkansas.org/files/dw/api/Docs/11358?_ga=2.79047133.812859282.1646336000-1282489368.1646228585 '''Overland Park Construction Specifications''' - Section 822]<br>[http://www.ksdot.org/burconsmain/specprov/2015specprov.asp '''KDOT 822 and 1907''' with modifications]}}


{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
{| width="800px" border="1" cellpadding="4" cellspacing="0" style="border:\#c9c9c9 1px solid; margin: 1em 1em 1em 0; border-collapse: collapse;"
Line 311: Line 311:
|}
|}


[[Preapproved_Materials|'''Return to Preapproved Materials''']]
[[Approved_Materials|'''Return to Approved Materials''']]
[[Category:Preapproved Materials]]
 
[[Category:Approved Materials]]

Latest revision as of 14:52, 3 March 2022

Return to Approved Materials

Inlet Frames

Applicable Specification:

Overland Park Standard Details (Area Inlet and Curb Inlet Details)
Inlet Frames
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
EJ Group, Inc. Curb Inlet 10” Throat 4/27/2017 Curb Inlet 10” Frame
Shawnee Steel & Welding Inc. Curb Inlet 10” Throat 4/27/2017 Curb Inlet 10” Frame
Shawnee Steel & Welding Inc. Area Inlet 10” Throat 4/27/2017 Area Inlet 10” Frame
Brown's Fabrication & Steel, LLC. Curb Inlet 10” Throat 6/26/2017 Curb Inlet 10” Frame
Brown's Fabrication & Steel, LLC. Area Inlet 10” Throat 6/26/2017 Area Inlet 10” Frame

Manhole Steps

Applicable Specification:

Overland Park Standard Details (Precast Manhole Detail)
Overland Park Construction Specifications - Section 815
Manhole Steps
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
American Step ML-13 3/27/2017 ML-13
American Step ML-10 3/27/2017 ML-10
MA Industries PS1-PF 3/27/2017 PS1-PF
MA Industries PS2-PF 3/27/2017 PS2-PF

Manhole Rings & Lids

Applicable Specification:

Overland Park Standard Details (Manhole Casting Detail)
Overland Park Construction Specifications - Section 815
Manhole Rings & Lids
Manufacturer Product Name or Number Type Approval Date Comment Catalog Cut Links
Castings from overseas shall have the coupon as required in AASHTO M-306 for testing.
EJ Group, Inc. 1501 A and Z Medium Duty 4/7/2017 1501
1502 A and Z Heavy Duty 4/7/2017 1502
Clay and Bailey N2161-CSTSWR Medium Duty 4/13/2017 N2161-CSTSWR
N2160-CSTSWR Heavy Duty 4/13/2017 N2160-CSTSWR

Sealants - Manhole

Applicable Specification:

Johnson County Wastewater Standard Details
Sealants - Manhole
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
Hamilton Kent No. 2 4/13/2017 Kent Seal No. 2
Trelleborg Bidco – C56 Butyl 4/13/2017 C56 Sealant
Press-Seal Corp. Pro-Stik 4/13/2017 Pro-Stik

Sealants - RCBs & Non-circular Pipe

Sealants - Pipe/RCBs
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
Blackhawk Mastic 4/14/2017 BH5401
Mar-Mac Manufacturing Mac-Wrap 4/14/2017 Mac-Wrap

Class III Concrete Pipe

Applicable Specification:

Overland Park Construction Specifications - Section 817
Class III Concrete Pipe
Manufacturer Pipe Size Wall Size Joint Design Gaskets Approval Date Catalog Cut Links
Pretech 15”-36” B Profile Hamilton Kent - Tylox Super Seal (HK TSS) 5/5/2017 RCP 15"-36"
Trelleborg Forsheda
Universal Polymer & Rubber 4/10/2018
Pretech 42”-78” B/C Profile HK TSS 5/5/2017 RCP 42"-78"
Forsheda
Universal Polymer & Rubber 4/10/2018
Forterra 12" C P4 (Profile) HK TSS135 5/5/2017
Forterra 15"-18" B/C P4 HK TSS135 5/5/2017
Forterra 21" B/C CX4 (Confined O-ring) Press Seal 21/32 5/5/2017
Forterra 24"-36" B/C P4 HK TSS135 5/5/2017
Forterra 42” B P3 HK TSS 185 5/5/2017
C CX4 Press Seal 25/32
Forterra 48” C P3 HK TSS 185 5/5/2017
CX4 Press Seal 25/32
Forterra 54” C P3 HK TSS 185 5/5/2017
CX4 Press Seal 25/32
Forterra 60", 66" C CX4 Press Seal 25/32 5/5/2017
Forterra 72", 78" C CX4 Press Seal 27/32 5/5/2017
Forterra 84", 90" B CX4 Press Seal 1 5/5/2017
Forterra 96", 144" B CX4 Press Seal 1-3/32 5/5/2017
Forterra 108", 120" B CX4 Press Seal 1-1/16 5/5/2017

Underdrains

Applicable Specification:

Overland Park Construction Specifications - Section 822
KDOT 822 and 1907 with modifications
Underdrains
Manufacturer Product Name or Number Type Approval Date Comment Catalog Cut Links
Contech A-2000 H 3/29/2017 A-2000
ADS N-12 T 3/29/2017 N-12
ADS AdvanEDGE T (Alt.) 4/14/2017 AdvanEDGE

Return to Approved Materials