Difference between revisions of "Approved Materials - Storm Drainage"

From PPM Wiki - City of Overland Park Projects and Procedures Manual Pages
Jump to navigation Jump to search
Line 153: Line 153:
|TecSeal 135
|TecSeal 135
|rowspan="2"|
|rowspan="2"|
|rowspan="2"|15”-36”
|rowspan="2" align="center"|15”-36”
|rowspan="2" align="center"|22-Jun-05
|rowspan="2" align="center"|22-Jun-05
|rowspan="2"|
|rowspan="2"|
Line 162: Line 162:
|TecSeal 185  
|TecSeal 185  
|rowspan="2"|
|rowspan="2"|
|rowspan="2"|42”–48”
|rowspan="2" align="center"|42”–48”
|rowspan="2" align="center"|22-Jun-05
|rowspan="2" align="center"|22-Jun-05
|rowspan="2"|
|rowspan="2"|
Line 171: Line 171:
||TecSeal 185
||TecSeal 185
|rowspan="2"|
|rowspan="2"|
|rowspan="2"|54”–60”
|rowspan="2" align="center"|54”–60”
|rowspan="2" align="center"|28-Jul-06
|rowspan="2" align="center"|28-Jul-06
|rowspan="2"|
|rowspan="2"|
Line 177: Line 177:
||Hamilton Kent
||Hamilton Kent
|-
|-
| Pre-Tech||Hamilton Kent||||72”
| Pre-Tech||Hamilton Kent||
|align="center"|72”
|align="center"|26-Mar-09||
|align="center"|26-Mar-09||
|-
|-
|rowspan="2"|Hydro-Conduit
|rowspan="2"|Hydro-Conduit
||CSR Delta Pipe Products  
||CSR Delta Pipe Products  
|rowspan="2"|R-4
|rowspan="2" align="center"|R-4
|rowspan="2"|12”-96”
|rowspan="2" align="center"|12”-96”
|rowspan="2" align="center"|2-May-05
|rowspan="2" align="center"|2-May-05
|rowspan="2"|560-101
|rowspan="2"|560-101
Line 192: Line 193:
||CSR Delta 15” PF ¾ DS 49.75
||CSR Delta 15” PF ¾ DS 49.75
|rowspan="2"|Offset
|rowspan="2"|Offset
|rowspan="2"|*15”–60”   
|rowspan="2" align="center"|*15”–60”   
|rowspan="2" align="center"|2-May-05
|rowspan="2" align="center"|2-May-05
|rowspan="2"|B100-CE-84
|rowspan="2"|B100-CE-84
Line 201: Line 202:
||Hamilton Kent
||Hamilton Kent
|rowspan="2"|P3
|rowspan="2"|P3
|rowspan="2"|30”
|rowspan="2" align="center"|30”
|rowspan="2" align="center"|22-May-01
|rowspan="2" align="center"|22-May-01
|rowspan="2"|
|rowspan="2"|
Line 209: Line 210:
|rowspan="2"|Cretex2
|rowspan="2"|Cretex2
||Hamilton Kent
||Hamilton Kent
|rowspan="2"|P3
|rowspan="2" align="center"|P3
|rowspan="2"|42”
|rowspan="2" align="center"|42”
|rowspan="2" align="center"|22-May-01
|rowspan="2" align="center"|22-May-01
|rowspan="2"|
|rowspan="2"|
Line 218: Line 219:
|rowspan="2"|Cretex3
|rowspan="2"|Cretex3
||Hamilton Kent
||Hamilton Kent
|rowspan="2"|P4
|rowspan="2" align="center"|P4
|rowspan="2"|12”-36”
|rowspan="2" align="center"|12”-36”
|rowspan="2" align="center"|22-May-01
|rowspan="2" align="center"|22-May-01
|rowspan="2"|
|rowspan="2"|
Line 227: Line 228:
|rowspan="4"|Cretex
|rowspan="4"|Cretex
||Pipe Gasket & Supply
||Pipe Gasket & Supply
|rowspan="4"|CX4
|rowspan="4" align="center"|CX4
|rowspan="4"|12”-78”
|rowspan="4" align="center"|12”-78”
|rowspan="4" align="center"|22-May-01
|rowspan="4" align="center"|22-May-01
|rowspan="4"|
|rowspan="4"|
Line 240: Line 241:
|rowspan="4"|Cretex
|rowspan="4"|Cretex
||Pipe Gasket & Supply
||Pipe Gasket & Supply
|rowspan="4"|CX4
|rowspan="4" align="center"|CX4
|rowspan="4"|12”-120”
|rowspan="4" align="center"|12”-120”
|rowspan="4" align="center"|22-May-01
|rowspan="4" align="center"|22-May-01
|rowspan="4"|
|rowspan="4"|
Line 253: Line 254:
|rowspan="4"|Cretex
|rowspan="4"|Cretex
||Pipe Gasket & Supply
||Pipe Gasket & Supply
|rowspan="4"|CX3
|rowspan="4" align="center"|CX3
|rowspan="4"|42”
|rowspan="4" align="center"|42”
|rowspan="4" align="center"|22-May-01
|rowspan="4" align="center"|22-May-01
|rowspan="4"|
|rowspan="4"|
Line 266: Line 267:
|rowspan="4"|Cretex
|rowspan="4"|Cretex
||Pipe Gasket & Supply
||Pipe Gasket & Supply
|rowspan="4"|CX3
|rowspan="4" align="center"|CX3
|rowspan="4"|48”-60”
|rowspan="4" align="center"|48”-60”
|rowspan="4" align="center"|22-May-01
|rowspan="4" align="center"|22-May-01
|rowspan="4"|
|rowspan="4"|

Revision as of 10:33, 12 June 2012

Inlet Frames

Applicable Specification:

Overland Park Standard Details
Inlet Frames
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
Shawnee Steel & Welding Inc. Curb Inlet 10” Throat 12/15/2005 Curb Inlet 10” Frame
Shawnee Steel & Welding Inc. Area Inlet 10” Throat 1/4/2006 Area Inlet 10” Frame

Manhole Steps

Applicable Specification:

Overland Park Standard Details
Manhole Steps
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
American Step ML-13 12/15/2005 ML-13
American Step ML-10 12/15/2005 ML-10
MA Industries PS1-PF 12/15/2005 PS1-PF
MA Industries PS2-PF 12/15/2005 PS2-PF
Clay & Bailey 2102 12/15/2005 2102

Manhole Rings & Lids

Applicable Specification:

Overland Park Standard Details
Manhole Rings & Lids
Manufacturer Product Name or Number Type Approval Date Comment Catalog Cut Links
Castings from overseas shall have the coupon as required in AASHTO M-306 for testing.
East Jordan Iron Works 1502 A and Z Heavy Duty 4/11/2006 1502
NACIP N-207P Heavy Duty 4/11/2006 N-207P
GCI Castings SM 2206 OP Heavy Duty 4/28/2006 SM 2206 OP
Deeter 1320 Heavy Duty 4/28/2006 1320
Clay and Bailey 2007-01-6032/2007-01-6050 Heavy Duty 5/30/2007 2007
Sigma MH-207OP-35 Heavy Duty 2/17/2010 207OP-35
East Jordan Iron Works 1501 A and Z Medium Duty 4/11/2006 1501
NACIP N-220P Medium Duty 4/11/2006 N-220P
GCI Castings SM 2100 OP Medium Duty 4/28/2006 SM 2100 OP
Deeter 2016 Medium Duty 4/28/2006 2016
Clay and Bailey 2020-01-6032/2020-01-6050 Medium Duty 4/12/2007 2020
Sigma MH-202OP-35 Medium Duty 2/17/2010 202OP-35

Sealants - Manhole

Applicable Specification:

Johnson County Wastewater Park Standard Details
Sealants - Manhole
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
Hamilton Kent No. 2 (two ¾” beads) 12/15/2005 Kent Seal
Hamilton Kent No. 2 (one 1” bead) 12/15/2005 Kent Seal
NPC Bidco – C56 Butyl 12/15/2005 C56 Butyl
Press-Seal Gasket Corp. Pro-Stik 12/15/2005 Pro-Stik

Sealants - Pipe/RCBs

Sealants - Pipe/RCBs
Manufacturer Product Name or Number Approval Date Comment Catalog Cut Links
Blackhawk Mastic 12/15/2005
Mar-Mac Manufacturing Mac-Wrap 12/15/2005 Mac-Wrap

Class III Concrete Pipe

Applicable Specification:

Overland Park Municipal Code 15.10
Class III Concrete Pipe
Manufacturer Gaskets Joint Design Pipe Size Approval Date Catalog Cut Links
Pre-Tech TecSeal 135 15”-36” 22-Jun-05
Hamilton Kent
Pre-Tech TecSeal 185 42”–48” 22-Jun-05
Hamilton Kent
Pre-Tech TecSeal 185 54”–60” 28-Jul-06
Hamilton Kent
Pre-Tech Hamilton Kent 72” 26-Mar-09
Hydro-Conduit CSR Delta Pipe Products R-4 12”-96” 2-May-05 560-101
(O-ring for R-4 joint design)
Hydro-Conduit CSR Delta 15” PF ¾ DS 49.75 Offset *15”–60” 2-May-05 B100-CE-84
(offset joint gasket)
Cretex1 Hamilton Kent P3 30” 22-May-01
(Tylox SuperSeal single offset for P3 & P4)
Cretex2 Hamilton Kent P3 42” 22-May-01
(Tylox SuperSeal single offset for P3 & P4)
Cretex3 Hamilton Kent P4 12”-36” 22-May-01
(Tylox SuperSeal single offset for P3 & P4)
Cretex Pipe Gasket & Supply CX4 12”-78” 22-May-01
(O-ring for CX3 & CX4)
Press-Seal Gasket Corp
(O-ring for CX3 & CX4)
Cretex Pipe Gasket & Supply CX4 12”-120” 22-May-01
(O-ring for CX3 & CX4)
Press-Seal Gasket Corp
(O-ring for CX3 & CX4)
Cretex Pipe Gasket & Supply CX3 42” 22-May-01
(O-ring for CX3 & CX4)
Press-Seal Gasket Corp
(O-ring for CX3 & CX4)
Cretex Pipe Gasket & Supply CX3 48”-60” 22-May-01
(O-ring for CX3 & CX4)
Press-Seal Gasket Corp
(O-ring for CX3 & CX4)
GeekNotesIcon.png Note: 15" is Class IV

Underdrains

Applicable Specification:

Overland Park Specifications for Underdrain
KDOT 822 and 1900 with modifications
Underdrains
Manufacturer Product Name or Number Type Approval Date Comment Catalog Cut Links
Contech A-2000 H & K 12/15/2005 A-2000
ADS N-12 L & E 12/15/2005 N-12
ADS AdvanEdge L (Alt.) 12/15/2005 AdvanEdge

Return to Preapproved Materials